For the further analysis and suppression of the electric locomotives neutral-section passing overvoltage, on the basis of theoretical analysis of the neutral-section passing harmonic resonance conditions, this paper e...For the further analysis and suppression of the electric locomotives neutral-section passing overvoltage, on the basis of theoretical analysis of the neutral-section passing harmonic resonance conditions, this paper establishes simplified harmonic resonance simulation models of the electric locomotives neutral-section passing using MATLAB/Simulink, and makes the overvoltage simulation analysis of the existing electric locomotives neutral-section passing system in the event of a harmonic resonance. Results show that when the system harmonic resonance occurs, the operating overvoltage of the neutral-section passing is serious intensified by the overvoltage of the harmonic resonance, which will make the voltage of the pantograph collector head exceeding 100kV. This amplitude of the overvoltage will breakdown the air gap, which will be a serious threat to the safety operation of the electric railway. However, this kind of neutral-section passing overvoltage hasn’t cause the attention in the field and theoretical studies, which need more analysis and verification in the further study.展开更多
Although quality assurance and quality control procedures are routinely applied in most air quality networks, outliers can still occur due to instrument malfunctions, the influence of harsh environments and the limita...Although quality assurance and quality control procedures are routinely applied in most air quality networks, outliers can still occur due to instrument malfunctions, the influence of harsh environments and the limitation of measuring methods. Such outliers pose challenges for data-powered applications such as data assimilation, statistical analysis of pollution characteristics and ensemble forecasting. Here, a fully automatic outlier detection method was developed based on the probability of residuals, which are the discrepancies between the observed and the estimated concentration values. The estimation can be conducted using filtering—or regressions when appropriate—to discriminate four types of outliers characterized by temporal and spatial inconsistency, instrument-induced low variances, periodic calibration exceptions, and less PM_(10) than PM_(2.5) in concentration observations, respectively. This probabilistic method was applied to detect all four types of outliers in hourly surface measurements of six pollutants(PM_(2.5), PM_(10),SO_2,NO_2,CO and O_3) from 1436 stations of the China National Environmental Monitoring Network during 2014-16. Among the measurements, 0.65%-5.68% are marked as outliers. with PM_(10) and CO more prone to outliers. Our method successfully identifies a trend of decreasing outliers from 2014 to 2016,which corresponds to known improvements in the quality assurance and quality control procedures of the China National Environmental Monitoring Network. The outliers can have a significant impact on the annual mean concentrations of PM_(2.5),with differences exceeding 10 μg m^(-3) at 66 sites.展开更多
文摘For the further analysis and suppression of the electric locomotives neutral-section passing overvoltage, on the basis of theoretical analysis of the neutral-section passing harmonic resonance conditions, this paper establishes simplified harmonic resonance simulation models of the electric locomotives neutral-section passing using MATLAB/Simulink, and makes the overvoltage simulation analysis of the existing electric locomotives neutral-section passing system in the event of a harmonic resonance. Results show that when the system harmonic resonance occurs, the operating overvoltage of the neutral-section passing is serious intensified by the overvoltage of the harmonic resonance, which will make the voltage of the pantograph collector head exceeding 100kV. This amplitude of the overvoltage will breakdown the air gap, which will be a serious threat to the safety operation of the electric railway. However, this kind of neutral-section passing overvoltage hasn’t cause the attention in the field and theoretical studies, which need more analysis and verification in the further study.
基金supported by the National Natural Science Foundation (Grant Nos.91644216 and 41575128)the CAS Information Technology Program (Grant No.XXH13506-302)Guangdong Provincial Science and Technology Development Special Fund (No.2017B020216007)
文摘Although quality assurance and quality control procedures are routinely applied in most air quality networks, outliers can still occur due to instrument malfunctions, the influence of harsh environments and the limitation of measuring methods. Such outliers pose challenges for data-powered applications such as data assimilation, statistical analysis of pollution characteristics and ensemble forecasting. Here, a fully automatic outlier detection method was developed based on the probability of residuals, which are the discrepancies between the observed and the estimated concentration values. The estimation can be conducted using filtering—or regressions when appropriate—to discriminate four types of outliers characterized by temporal and spatial inconsistency, instrument-induced low variances, periodic calibration exceptions, and less PM_(10) than PM_(2.5) in concentration observations, respectively. This probabilistic method was applied to detect all four types of outliers in hourly surface measurements of six pollutants(PM_(2.5), PM_(10),SO_2,NO_2,CO and O_3) from 1436 stations of the China National Environmental Monitoring Network during 2014-16. Among the measurements, 0.65%-5.68% are marked as outliers. with PM_(10) and CO more prone to outliers. Our method successfully identifies a trend of decreasing outliers from 2014 to 2016,which corresponds to known improvements in the quality assurance and quality control procedures of the China National Environmental Monitoring Network. The outliers can have a significant impact on the annual mean concentrations of PM_(2.5),with differences exceeding 10 μg m^(-3) at 66 sites.