Maintenance of Storage Batteries in Automatic Meteorological Observation Stations 被引量:1
1
作者 Yanjun Du Bin Zhang Chaochang Zhang 《Meteorological and Environmental Research》 CAS 2013年第5期52-53,共2页
Firstly, the definition, structure and working principles of storage batteries in automatic meteorological observation stations were stated simply, and then the daily maintenance of the storage batteries were introduc... Firstly, the definition, structure and working principles of storage batteries in automatic meteorological observation stations were stated simply, and then the daily maintenance of the storage batteries were introduced according to previous practical experience, finally typical faults of storage batteries were analyzed. Practical evidence shows that timely external maintenance and enough supply of electrolyte can greatly extend the lifespan of storage batteries. 展开更多
关键词 automatic meteorological observation station Storage battery Maintenance China
下载PDF
Preliminary Study on the Differences between Automatic-observed and Manual-observed Wind Speed and Its Correction
2
作者 张志富 任芝花 范邵华 《Meteorological and Environmental Research》 CAS 2010年第4期1-6,10,共7页
Comparing and analyzing the difference between automatic-observed and manual-observed wind speed based on the wind speed parallel observations in two methods, we find that many elements can influence the difference be... Comparing and analyzing the difference between automatic-observed and manual-observed wind speed based on the wind speed parallel observations in two methods, we find that many elements can influence the difference between automatic-observed and manual-observed wind speed, including the levels of speed wind, observation instruments and different regions. According to these elements, correction has been conducted, and find that the correction according to the level of wind speed has the best correction effect. 展开更多
关键词 Manual observation automatic observation Level of wind speed observation instruments China
下载PDF
Analysis on the Influence of Automatic Station Temperature Data on the Sequence Continuity of Historical Meteorological Data 被引量:1
3
作者 CHEN Ming1, GAI Xiao-bo2, FAN Xin-yu1, SONG Min1 1. Jinzhou Meteorology Bureau in Liaoning Province, Jinzhou 121001, China 2. Dalian Meteorological Bureau in Liaoning Province, Dalian 116001, China 《Meteorological and Environmental Research》 CAS 2011年第4期12-14,17,共4页
[Objective] The research aimed to study the influence of automatic station data on the sequence continuity of historical meteorological data. [Method] Based on the temperature data which were measured by the automatic... [Objective] The research aimed to study the influence of automatic station data on the sequence continuity of historical meteorological data. [Method] Based on the temperature data which were measured by the automatic meteorological station and the corresponding artificial observation data during January-December in 2001, the monthly average, maximum and minimum temperatures in the automatic station were compared with the corresponding artificial observation temperature data in the parallel observation period by using the contrast difference and the standard deviation of difference value. The difference between the automatic station and the artificial data, the variation characteristics were understood. Meanwhile, the significance test and analysis of annual average value were carried out by the data sequence during 1990-2009. The influence of automatic station replacing the artificial observation on the sequence continuity of historical temperature data was discussed. [Result] Although the two temperature data in the parallel observation period had the certain difference, the difference was in the permitted range of automatic station difference value on average. The difference of individual month surpassed the permitted range of automatic station difference value. The significance test showed that the annual average temperature and the annual average minimum temperature which were observed in the automatic station had the difference with the historical data. It had the certain influence on the annual temperature sequence, but the difference wasn’t significant as a whole. When the automatic observation combined with the artificial observation to use, the sequence needed carry out the homogeneous test and correction. [Conclusion] The research played the important role on guaranteeing the monorail running of automatic station, optimizing the meteorological surface observation system, improving the climate sequence continuity of meteorological element and the reliability of climate statistics. 展开更多
关键词 automatic observation Artificial observation Data sequence ANALYSIS China