期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Influence factors on the ground surface rupture zone induced by buried normal fault dislocation
1
作者 Jianfeng Qi Fengjunnan Liu +1 位作者 Xiangyu Yang Yang Zhao 《Earthquake Science》 2020年第2期62-71,共10页
The seismic disaster presents a zonal distribution along the fault strike.In this paper,rupture zone of ground surface soil caused by the uniform dislocation,inclined dislocation and warped dislocation of buried norma... The seismic disaster presents a zonal distribution along the fault strike.In this paper,rupture zone of ground surface soil caused by the uniform dislocation,inclined dislocation and warped dislocation of buried normal fault are studied by constituting a three-dimensional finite element model in Automatic Dynamic Incremental Nonlinear Analysis(ADINA).According to the critical value of surface rupture,the variational features and influencing factors of width and starting position of the"avoiding zone"in engineering construction are analyzed by using 96 model calculations.The main results are as follows:(1)Since the rupture zone of the ground surface soil from the point of mechanics is different from the"avoidance zone"from the point of engineering safety,the equivalent plastic strain and the total displacement ratio should be considered to evaluate the effect of the seismic ground movement on buildings.(2)During fault dislocation,plastic failure firstly occurred on the ground surface soil of the footwall side,and then the larger deformation gradually moved to the side of the hanging wall of the fault with the increase of fault displacement.(3)When the vertical displacement of buried fault reaches 3 m,the width of"avoiding zone"in engineering construction varies within the range of 10-90 m,which is most affected by the thickness of overlying soil and the dip angle of the fault. 展开更多
关键词 buried normal fault surface rupture avoiding zone numerical simulation influence factors
下载PDF
Direct Model Predictive Control of Noninverting Buck-boost DC-DC Converter
2
作者 Basharat Ullah Hikmat Ullah Sumeet Khalid 《CES Transactions on Electrical Machines and Systems》 CSCD 2022年第3期332-339,共8页
In this paper, direct model predictive control(DMPC) of the noninverting buck-boost DC-DC converter with magnetic coupling between input and output is proposed. Unlike most of the other converters, the subject convert... In this paper, direct model predictive control(DMPC) of the noninverting buck-boost DC-DC converter with magnetic coupling between input and output is proposed. Unlike most of the other converters, the subject converter has the advantage of exhibiting minimum phase behavior in the boost mode. However, a major issue that arises in the classical control of the converter is the dead zone near the transition of the buck and boost mode. The reason for the dead zone is practically unrealizable duty cycles, which are close to zero or unity, of pulse width modulation(PWM) near the transition region. To overcome this issue, we propose to use DMPC. In DMPC, the switches are manipulated directly by the controller without the need of PWM.Thereby, avoiding the dead zone altogether. DMPC also offers several other advantages over classical techniques that include optimality and explicit current constraints. Simulations of the proposed DMPC technique on the converter show that the dead zone has been successfully avoided. Moreover, simulations show that the DMPC technique results in a significantly improved performance as compared to the classical control techniques in terms of response time, reference tracking, and overshoot. 展开更多
关键词 Noninverting buck-boost DC-DC converter Direct model predictive control Dead zone avoidance
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部