Frequent rockburst disasters in deep-buried engineering projects severely impact construction. To explore the influence of axial stress on rockburst in deep-buried tunnels, large-scale true triaxial rockburst experime...Frequent rockburst disasters in deep-buried engineering projects severely impact construction. To explore the influence of axial stress on rockburst in deep-buried tunnels, large-scale true triaxial rockburst experiments were conducted under four different axial stress ratio conditions (ηt, axial loading stress/vertical loading stress) using a self-developed true triaxial loading device under the condition of "pre-loading before excavation". The influence of axial stress on the rockburst process and failure characteristics in deep tunnels was studied using a combination of real-time video monitoring, rockburst debris sieving, and acoustic emission monitoring. The results indicate: (1) all four specimens subjected to different axial stress ratio loading conditions exhibited three stages of macroscopic failure: small particle ejection, flake spalling, and large fragment ejection. Ultimately, "V"-shaped notches appeared on both sides of the tunnel. (2) The failure stress, fragment volume, and fragment size distribution of the rockburst specimens exhibited a clear two-stage failure characteristic with increasing axial stress ratio. In the lower axial stress ratio stage (ηt ≤ 0.7), the increase in the axial stress ratio enhances lateral confinement, thereby increasing the crack initiation strength of the surrounding rock, inhibiting crack formation and propagation, and thus suppressing damage to the surrounding rock of the tunnel. In the higher axial stress ratio stage (ηt > 0.7), the increase in axial stress ratio makes the Poisson effect of the surrounding rock more pronounced, promoting the generation and propagation of cracks along the tunnel axis direction, thereby promoting damage to the surrounding rock. (3) Based on the analysis of acoustic emission parameters (fracture properties), it can be concluded that in the lower axial stress ratio stage (ηt ≤ 0.7), an increase in the axial stress ratio leads to a higher proportion of shear fracture in rockburst damage. Conversely, in the higher axial stress ratio stage (ηt > 0.7), the increase in axial stress ratio gradually reduces the proportion of shear fracture in rockburst damage.展开更多
Nonlinear finite element analysis and parametric studies were carried out to study the influence of axial load ratio on the shear behavior of the through-diaphragm connections of concrete-filled square steel tubular c...Nonlinear finite element analysis and parametric studies were carried out to study the influence of axial load ratio on the shear behavior of the through-diaphragm connections of concrete-filled square steel tubular columns. The analysis reveals that smaller axial load ratio can improve the shear bearing capacity and ductility while larger axial load ratio will decrease the shear behavior of the through-diaphragm connections. The parametric studies indicate that the axial load ratio should be limited to less than 0.4 and its influence should be considered in the analysis and design of such connections.展开更多
AIM: To measure and analysis axial length(AL)/corneal radius of curvature(CRC) ratio and other refractive parameters, provide a medical reference range for refractive development evaluation and earlier visual impairme...AIM: To measure and analysis axial length(AL)/corneal radius of curvature(CRC) ratio and other refractive parameters, provide a medical reference range for refractive development evaluation and earlier visual impairment screening of 3 to 4 y kindergarten students.METHODS: Between April and June 2017, a total of 4350 participants aged 3-to 4-year-old(8700 eyes) from 10 cluster random sampling kindergartens in Shanghai, Pudong District were involved. According to the measurement and analysis of the unaided visual acuity(VA), AL, CRC, AL/CRC ratio, astigmatism and other refractive parameters, the data distribution and reference range were obtained.RESULTS: Uncorrected VA of examined children was 0.23±0.08(logMAR, mean±SD) [95% confidence interval(CI) range ≤0.36];AL was 22.10±0.79 mm(95%CI 20.55-23.65);CRC was 7.86±0.26 mm(95%CI, 7.35-8.37);AL/CRC ratio was 2.81±0.12(95%CI, 2.57-3.05). The median of astigmatism was-0.5 D, a total of 56.3% had astigmatism <-0.50 D, 85.3%<-1.00 D, 6.7%>-1.50 D;71% were astigmatism with the rule. Eye-specific analyses were conducted. Statistical difference of VA was in right and left eyes. There were no significant differences between two eyes of AL, CRC, AL/CRC ratio and astigmatism(P>0.05).CONCLUSION: VA and AL/CRC ratio reference could be used to assess refractive development in children and screening uncorrected refractive errors or amblyopia. Astigmatism needs to be considered in the diagnosis.展开更多
Currently, domestic and abroad scholars put more attention on contra-rotating dual-rotor axial fan. But there is less scholars study on asymmetric dual-rotor small axial fan, which is one of the contra-rotating dual-r...Currently, domestic and abroad scholars put more attention on contra-rotating dual-rotor axial fan. But there is less scholars study on asymmetric dual-rotor small axial fan, which is one of the contra-rotating dual-rotor axial fans. Like axial fan, many factors have influence on the performance of the asymmetric dual-rotor small axial flow fan, such as the wheel hub ratio, blade shape, blade number, stagger angle and the tip clearance. Because wheel hub ratio has great impact on the performance of the fan, we choose the size of wheel hub ratio as a variable factor to study the model change. There is a different wheel hub ratio between front stage impeller and rear stage of asymmetric dual-rotor small axial fan, so it is very beneficial to select the greater wind area that the fan area of external diameter minuses the area occupied by the blades and the hub as front stage impeller. In this paper, the hub-ratio of front stage impeller is 0.72, and that of rear stage is 0.72, 0.67 and 0.62 respectively along with the front stage impeller. Three kinds of models with different hub ratio of rear stage are simulated using the CFD software and the static characteristics are obtained. Based on the experimental test results, the internal flow field of the asymmetric dual-rotor small axial fan is analyzed in detail, the impact trends of different hub-ratio on the performance of asymmetric dual-rotor small axial fan are obtained and the argument of structure optimization for dual-rotor small axial fan is provided.展开更多
基金funded by the National Natural Science Foundation of China(Nos.42077228,52174085)。
文摘Frequent rockburst disasters in deep-buried engineering projects severely impact construction. To explore the influence of axial stress on rockburst in deep-buried tunnels, large-scale true triaxial rockburst experiments were conducted under four different axial stress ratio conditions (ηt, axial loading stress/vertical loading stress) using a self-developed true triaxial loading device under the condition of "pre-loading before excavation". The influence of axial stress on the rockburst process and failure characteristics in deep tunnels was studied using a combination of real-time video monitoring, rockburst debris sieving, and acoustic emission monitoring. The results indicate: (1) all four specimens subjected to different axial stress ratio loading conditions exhibited three stages of macroscopic failure: small particle ejection, flake spalling, and large fragment ejection. Ultimately, "V"-shaped notches appeared on both sides of the tunnel. (2) The failure stress, fragment volume, and fragment size distribution of the rockburst specimens exhibited a clear two-stage failure characteristic with increasing axial stress ratio. In the lower axial stress ratio stage (ηt ≤ 0.7), the increase in the axial stress ratio enhances lateral confinement, thereby increasing the crack initiation strength of the surrounding rock, inhibiting crack formation and propagation, and thus suppressing damage to the surrounding rock of the tunnel. In the higher axial stress ratio stage (ηt > 0.7), the increase in axial stress ratio makes the Poisson effect of the surrounding rock more pronounced, promoting the generation and propagation of cracks along the tunnel axis direction, thereby promoting damage to the surrounding rock. (3) Based on the analysis of acoustic emission parameters (fracture properties), it can be concluded that in the lower axial stress ratio stage (ηt ≤ 0.7), an increase in the axial stress ratio leads to a higher proportion of shear fracture in rockburst damage. Conversely, in the higher axial stress ratio stage (ηt > 0.7), the increase in axial stress ratio gradually reduces the proportion of shear fracture in rockburst damage.
基金Supported by the National Natural Science Foundation of China(No.51268054 and No.51468061)the Natural Science Foundation of Tianjin(No.13JCQNJC07300)Foundation of Xinjiang University(No.XY110137)
文摘Nonlinear finite element analysis and parametric studies were carried out to study the influence of axial load ratio on the shear behavior of the through-diaphragm connections of concrete-filled square steel tubular columns. The analysis reveals that smaller axial load ratio can improve the shear bearing capacity and ductility while larger axial load ratio will decrease the shear behavior of the through-diaphragm connections. The parametric studies indicate that the axial load ratio should be limited to less than 0.4 and its influence should be considered in the analysis and design of such connections.
基金Supported by the National Natural Science Foundation of China(No.81371040)Shanghai Smart Medical Special Research Project(No.2018ZHYL0221)+1 种基金Shanghai Municipal Education Commission-Gaofeng Clinical Medicine Grant Support(No.20181810)the Science and Technology Commission of Shanghai(No.17DZ2260100)
文摘AIM: To measure and analysis axial length(AL)/corneal radius of curvature(CRC) ratio and other refractive parameters, provide a medical reference range for refractive development evaluation and earlier visual impairment screening of 3 to 4 y kindergarten students.METHODS: Between April and June 2017, a total of 4350 participants aged 3-to 4-year-old(8700 eyes) from 10 cluster random sampling kindergartens in Shanghai, Pudong District were involved. According to the measurement and analysis of the unaided visual acuity(VA), AL, CRC, AL/CRC ratio, astigmatism and other refractive parameters, the data distribution and reference range were obtained.RESULTS: Uncorrected VA of examined children was 0.23±0.08(logMAR, mean±SD) [95% confidence interval(CI) range ≤0.36];AL was 22.10±0.79 mm(95%CI 20.55-23.65);CRC was 7.86±0.26 mm(95%CI, 7.35-8.37);AL/CRC ratio was 2.81±0.12(95%CI, 2.57-3.05). The median of astigmatism was-0.5 D, a total of 56.3% had astigmatism <-0.50 D, 85.3%<-1.00 D, 6.7%>-1.50 D;71% were astigmatism with the rule. Eye-specific analyses were conducted. Statistical difference of VA was in right and left eyes. There were no significant differences between two eyes of AL, CRC, AL/CRC ratio and astigmatism(P>0.05).CONCLUSION: VA and AL/CRC ratio reference could be used to assess refractive development in children and screening uncorrected refractive errors or amblyopia. Astigmatism needs to be considered in the diagnosis.
文摘Currently, domestic and abroad scholars put more attention on contra-rotating dual-rotor axial fan. But there is less scholars study on asymmetric dual-rotor small axial fan, which is one of the contra-rotating dual-rotor axial fans. Like axial fan, many factors have influence on the performance of the asymmetric dual-rotor small axial flow fan, such as the wheel hub ratio, blade shape, blade number, stagger angle and the tip clearance. Because wheel hub ratio has great impact on the performance of the fan, we choose the size of wheel hub ratio as a variable factor to study the model change. There is a different wheel hub ratio between front stage impeller and rear stage of asymmetric dual-rotor small axial fan, so it is very beneficial to select the greater wind area that the fan area of external diameter minuses the area occupied by the blades and the hub as front stage impeller. In this paper, the hub-ratio of front stage impeller is 0.72, and that of rear stage is 0.72, 0.67 and 0.62 respectively along with the front stage impeller. Three kinds of models with different hub ratio of rear stage are simulated using the CFD software and the static characteristics are obtained. Based on the experimental test results, the internal flow field of the asymmetric dual-rotor small axial fan is analyzed in detail, the impact trends of different hub-ratio on the performance of asymmetric dual-rotor small axial fan are obtained and the argument of structure optimization for dual-rotor small axial fan is provided.