Boiler fan is the main power consumption device in thermal power units and the induced draft fan accounted for the largest proportion. Reducing the energy consumption rate of induced draft fan is the main path to redu...Boiler fan is the main power consumption device in thermal power units and the induced draft fan accounted for the largest proportion. Reducing the energy consumption rate of induced draft fan is the main path to reduce the power consumption rate of thermal power units. The induce fan driven by small turbine is greatly effective for reducing the power consumption rate and the supply coal consumption rate in large thermal power plant. Take 1000 MW power units for example, the selection of steam source for steam turbine were discussed and economic performance of the unit under different steam source was compared in this paper. The result shows that compared with the motor driven method, there is about 1.6 g/kWh decrease in supply coal consumption rate driven by the fourth stage extraction steam;whereas there is about 2.5 g/kWh decrease in supply coal consumption rate driven by the fifth stage extraction steam.展开更多
As the critical equipment,large axial-flow fan(LAF)is used widely in highway tunnels for ventilating.Note that any malfunction of LAF can cause severe consequences for traffic.Specifically,fault deterioration is suppr...As the critical equipment,large axial-flow fan(LAF)is used widely in highway tunnels for ventilating.Note that any malfunction of LAF can cause severe consequences for traffic.Specifically,fault deterioration is suppressed tremendously when an abnormal state is detected in the stage of early fault.Thus,the monitoring of the early fault characteristics is very difficult because of the low signal amplitude and system disturbance(or noise).In order to overcome this problem,a novel early fault judgment method to predict the operation trend is proposed in this paper.The vibration-electric information fusion,the support vector machine(SVM)with particle swarm optimization(PSO),and the cross-validation(CV)for predicting LAF operation states are proposed and discussed.Finally,the results of the experimental study verify that the performance of the proposed method is superior to that of the contrast models.展开更多
Airfoil is the element of fan blade design. It is strongly anticipated to design a fan of ave- raged high performance over a wide operation range. Multi-point optimization design of airfoil for axial flow fan was prop...Airfoil is the element of fan blade design. It is strongly anticipated to design a fan of ave- raged high performance over a wide operation range. Multi-point optimization design of airfoil for axial flow fan was proposed over specific operation range. Weighted objective function of airfoil lift-drag ratio was constructed for several operation points around the designing one. Airfoil was defined by parametric B-spline curve of limited shape controlling points. Results show that normal standard airfoils have remained spaces to be optimized under specific operation conditions. Airfoil performance is sensitive to flow′s Reynolds number and cascade solidity. Predicting flow transition along airfoil profile is essential to search for optimized one. Optimized airfoil of wide operation range is possible to obtain with prescribed fitness function. Obtainments of multi-point optimization may be relatively lower at design point, but positive obtainments are achieved at off-design ones. Resulted airfoil is specially suitable for axial flow fans operating frequently at off-design point such as air condition coolers.展开更多
文摘Boiler fan is the main power consumption device in thermal power units and the induced draft fan accounted for the largest proportion. Reducing the energy consumption rate of induced draft fan is the main path to reduce the power consumption rate of thermal power units. The induce fan driven by small turbine is greatly effective for reducing the power consumption rate and the supply coal consumption rate in large thermal power plant. Take 1000 MW power units for example, the selection of steam source for steam turbine were discussed and economic performance of the unit under different steam source was compared in this paper. The result shows that compared with the motor driven method, there is about 1.6 g/kWh decrease in supply coal consumption rate driven by the fourth stage extraction steam;whereas there is about 2.5 g/kWh decrease in supply coal consumption rate driven by the fifth stage extraction steam.
基金Project(2018YFB2002100)supported by the National Key R&D Program of China。
文摘As the critical equipment,large axial-flow fan(LAF)is used widely in highway tunnels for ventilating.Note that any malfunction of LAF can cause severe consequences for traffic.Specifically,fault deterioration is suppressed tremendously when an abnormal state is detected in the stage of early fault.Thus,the monitoring of the early fault characteristics is very difficult because of the low signal amplitude and system disturbance(or noise).In order to overcome this problem,a novel early fault judgment method to predict the operation trend is proposed in this paper.The vibration-electric information fusion,the support vector machine(SVM)with particle swarm optimization(PSO),and the cross-validation(CV)for predicting LAF operation states are proposed and discussed.Finally,the results of the experimental study verify that the performance of the proposed method is superior to that of the contrast models.
基金Strategic Leading Project of Shanghai Municipal Science Committee(16DZ1121202)
文摘Airfoil is the element of fan blade design. It is strongly anticipated to design a fan of ave- raged high performance over a wide operation range. Multi-point optimization design of airfoil for axial flow fan was proposed over specific operation range. Weighted objective function of airfoil lift-drag ratio was constructed for several operation points around the designing one. Airfoil was defined by parametric B-spline curve of limited shape controlling points. Results show that normal standard airfoils have remained spaces to be optimized under specific operation conditions. Airfoil performance is sensitive to flow′s Reynolds number and cascade solidity. Predicting flow transition along airfoil profile is essential to search for optimized one. Optimized airfoil of wide operation range is possible to obtain with prescribed fitness function. Obtainments of multi-point optimization may be relatively lower at design point, but positive obtainments are achieved at off-design ones. Resulted airfoil is specially suitable for axial flow fans operating frequently at off-design point such as air condition coolers.