AIM:To present the 1-year results of a prospective cohort study investigating the efficacy,potential mechanism,and safety of orthokeratology(ortho-k)with different back optic zone diameters(BOZD)for myopia control in ...AIM:To present the 1-year results of a prospective cohort study investigating the efficacy,potential mechanism,and safety of orthokeratology(ortho-k)with different back optic zone diameters(BOZD)for myopia control in children.METHODS:This randomized clinical study was performed between Dec.2020 and Dec.2021.Participants were randomly assigned to three groups wearing ortho-k:5 mm BOZD(5-MM group),5.5 mm BOZD(5.5-MM group),and 6 mm BOZD(6-MM group).The 1-year data were recorded,including axial length,relative peripheral refraction(RPR,measured by multispectral refractive topography,MRT),and visual quality.The contrast sensitivity(CS)was evaluated by CSV-1000 instrument with spatial frequencies of 3,6,12,and 18 cycles/degree(c/d);the corneal higher-order aberrations(HOAs)were measured by iTrace aberration analyzer.The one-way ANOVA was performed to assess the differences between the three groups.The correlation between the change in AL and RPR was calculated by Pearson’s correlation coefficient.RESULTS:The 1-year results of 20,21,and 21 subjects in the 5-MM,5.5-MM,and 6-MM groups,respectively,were presented.There were no statistical differences in baseline age,sex,or ocular parameters between the three groups(all P>0.05).At the 1-year visit,the 5-MM group had lower axial elongation than the 6-MM group(0.07±0.09 vs 0.18±0.11 mm,P=0.001).The 5-MM group had more myopic total RPR(TRPR,P=0.014),with RPR in the 15°–30°(RPR 15–30,P=0.015),30°–45°(RPR 30–45,P=0.011),temporal(RPR-T,P=0.008),and nasal area(RPR-N,P<0.001)than the 6-MM group.RPR 15–30 in the 5.5-MM group was more myopic than that in the 6-MM group(P=0.002),and RPR-N in the 5-MM group was more myopic than that in the 5.5-MM group(P<0.001).There were positive correlations between the axial elongation and the change in TRPR(r=0.756,P<0.001),RPR 15–30(r=0.364,P=0.004),RPR 30–45(r=0.306,P=0.016),and RPR-N(r=0.253,P=0.047).The CS decreased at 3 c/d(P<0.001),and the corneal HOAs increased in the 5-MM group(P=0.030).CONCLUSION:Ortho-k with 5 mm BOZD can control myopia progression more effectively.The mechanism may be associated with greater myopic shifts in RPR.展开更多
Displacement control algorithms commonly used to evaluate axial force-bending moment(PM)diagrams may lead to incorrect interpretations of the strength envelopes for asymmetric sections.This paper aims to offer valuabl...Displacement control algorithms commonly used to evaluate axial force-bending moment(PM)diagrams may lead to incorrect interpretations of the strength envelopes for asymmetric sections.This paper aims to offer valuable insights by comparing existing displacement control algorithms with a newly proposed force control algorithm.The main focus is on the PM diagrams of three example sections that exhibit varying degrees of asymmetry.The comparative study indicates that conventional displacement control algorithms inevitably introduce non-zero out-of-plane bending moments.The reported PM diagram in such cases erroneously neglects the out-of-plane moment and fails to represent the strength envelope accurately.This oversight results in significant and unconservative errors when verifying the strength of asymmetric sections.展开更多
Frequent rockburst disasters in deep-buried engineering projects severely impact construction. To explore the influence of axial stress on rockburst in deep-buried tunnels, large-scale true triaxial rockburst experime...Frequent rockburst disasters in deep-buried engineering projects severely impact construction. To explore the influence of axial stress on rockburst in deep-buried tunnels, large-scale true triaxial rockburst experiments were conducted under four different axial stress ratio conditions (ηt, axial loading stress/vertical loading stress) using a self-developed true triaxial loading device under the condition of "pre-loading before excavation". The influence of axial stress on the rockburst process and failure characteristics in deep tunnels was studied using a combination of real-time video monitoring, rockburst debris sieving, and acoustic emission monitoring. The results indicate: (1) all four specimens subjected to different axial stress ratio loading conditions exhibited three stages of macroscopic failure: small particle ejection, flake spalling, and large fragment ejection. Ultimately, "V"-shaped notches appeared on both sides of the tunnel. (2) The failure stress, fragment volume, and fragment size distribution of the rockburst specimens exhibited a clear two-stage failure characteristic with increasing axial stress ratio. In the lower axial stress ratio stage (ηt ≤ 0.7), the increase in the axial stress ratio enhances lateral confinement, thereby increasing the crack initiation strength of the surrounding rock, inhibiting crack formation and propagation, and thus suppressing damage to the surrounding rock of the tunnel. In the higher axial stress ratio stage (ηt > 0.7), the increase in axial stress ratio makes the Poisson effect of the surrounding rock more pronounced, promoting the generation and propagation of cracks along the tunnel axis direction, thereby promoting damage to the surrounding rock. (3) Based on the analysis of acoustic emission parameters (fracture properties), it can be concluded that in the lower axial stress ratio stage (ηt ≤ 0.7), an increase in the axial stress ratio leads to a higher proportion of shear fracture in rockburst damage. Conversely, in the higher axial stress ratio stage (ηt > 0.7), the increase in axial stress ratio gradually reduces the proportion of shear fracture in rockburst damage.展开更多
Given their numerous functional and architectural benefits,such as improved bearing capacity and increased resistance to elastic instability modes,cold-formed steel(CFS)built-up sections have become increasingly devel...Given their numerous functional and architectural benefits,such as improved bearing capacity and increased resistance to elastic instability modes,cold-formed steel(CFS)built-up sections have become increasingly developed and used in recent years,particularly in the construction industry.This paper presents an analytical and numerical study of assembled CFS two single channel-shaped columns with different slenderness and configurations(backto-back,face-to-face,and box).These columns were joined by double-row rivets for the back-to-back and box configurations,whereas they were welded together for the face-to-face design.The built-up columns were filled with ordinary concrete of good strength.Finite element models were applied,using ABAQUS software,to assess mechanical performance and study the influence of assembly techniques on the behavior of cold-formed columns under axial compression.Analytical approaches based on Eurocode 3 and Eurocode 4 recommendations for un-filled and concrete-filled columns respectively were followed for the numerical analysis,and concrete confinement effects were also considered per American Concrete Institute(ACI)standards for face-to-face and box configurations.The obtained results indicated a good correlation between the numerical results and the proposed analytical methodology which did not exceed 8%.The failure modes showed that the columns failed due to instabilities such as local and global buckling.展开更多
AIM:To elucidate whether differences exist in the impact on retarding the elongation of axial length(AL)among children with myopia when utilizing orthokeratology(ortho-k)lenses employing the corneal refractive therapy...AIM:To elucidate whether differences exist in the impact on retarding the elongation of axial length(AL)among children with myopia when utilizing orthokeratology(ortho-k)lenses employing the corneal refractive therapy(CRT)design versus those employing the vision shaping treatment(VST)design.METHODS:This retrospective clinical trial aimed to collect and analyze AL data from individuals who wore ortho-k lenses for three years.A total of 654 subjects were enrolled and prescribed one of the three specific brands of ortho-k lenses:CRT,Euclid,and Mouldway.The study’s primary focus was to compare the rates of AL elongation and myopic progression across these three brands of ortho-k lenses.RESULTS:In the 3-year follow-up,the AL elongation exhibited variations of 0.73±0.36 mm in the CRT lens group,0.59±0.37 mm in the Euclid lens group,and 0.63±0.38 mm in the Mouldway lens group.A noteworthy disparity emerged between the CRT and Mouldway groups(P<0.01),as well as between the CRT and Euclid groups(P<0.001).Additionally,it was observed that 32.1%of participants who wore CRT lenses experienced a decelerated progression of myopia,in contrast to 47.2%in the Euclid group and 44.4%in the Mouldway group.Statistical analyses revealed a statistically significant distinction between the CRT and Euclid groups(P<0.01),and similarly,the CRT group demonstrated a statistically significant difference when compared to the Mouldway group(P<0.05).CONCLUSION:Ortho-k lenses represent a pragmatic strategy for mitigating the advancement of myopia.In contradistinction to ortho-k lenses utilizing the CRT design,those employing the VST design exhibited a more favorable impact regarding retarding AL elongation.展开更多
This narrative review aimed to have an algorithmic approach to microphthalmos by a systematic search.The definition can be related to a number of special phenotypes.In the more challenging cases of complex microphthal...This narrative review aimed to have an algorithmic approach to microphthalmos by a systematic search.The definition can be related to a number of special phenotypes.In the more challenging cases of complex microphthalmos,relative anterior microphthalmos,and nanophthalmos,the surgeon can approach these cases more safely if they have a deep understanding of the anatomical variations and ideal formulae for intraocular lens computation and knows how to avoid intra-and post-operative complications.In this article,we review the criteria by which we recognize and describe pre-,intra-,and post-operative considerations,as well as discuss the ideal intraocular lenses for microphthalmos,given the intricate varieties of small eye phenotypes.展开更多
Recently,deep learning-based image inpainting methods have made great strides in reconstructing damaged regions.However,these methods often struggle to produce satisfactory results when dealing with missing images wit...Recently,deep learning-based image inpainting methods have made great strides in reconstructing damaged regions.However,these methods often struggle to produce satisfactory results when dealing with missing images with large holes,leading to distortions in the structure and blurring of textures.To address these problems,we combine the advantages of transformers and convolutions to propose an image inpainting method that incorporates edge priors and attention mechanisms.The proposed method aims to improve the results of inpainting large holes in images by enhancing the accuracy of structure restoration and the ability to recover texture details.This method divides the inpainting task into two phases:edge prediction and image inpainting.Specifically,in the edge prediction phase,a transformer architecture is designed to combine axial attention with standard self-attention.This design enhances the extraction capability of global structural features and location awareness.It also balances the complexity of self-attention operations,resulting in accurate prediction of the edge structure in the defective region.In the image inpainting phase,a multi-scale fusion attention module is introduced.This module makes full use of multi-level distant features and enhances local pixel continuity,thereby significantly improving the quality of image inpainting.To evaluate the performance of our method.comparative experiments are conducted on several datasets,including CelebA,Places2,and Facade.Quantitative experiments show that our method outperforms the other mainstream methods.Specifically,it improves Peak Signal-to-Noise Ratio(PSNR)and Structure Similarity Index Measure(SSIM)by 1.141~3.234 db and 0.083~0.235,respectively.Moreover,it reduces Learning Perceptual Image Patch Similarity(LPIPS)and Mean Absolute Error(MAE)by 0.0347~0.1753 and 0.0104~0.0402,respectively.Qualitative experiments reveal that our method excels at reconstructing images with complete structural information and clear texture details.Furthermore,our model exhibits impressive performance in terms of the number of parameters,memory cost,and testing time.展开更多
Single-atom materials have demonstrated attractive physicochemical characteristics.However,understanding the relationships between the coordination environment of single atoms and their properties at the atomic level ...Single-atom materials have demonstrated attractive physicochemical characteristics.However,understanding the relationships between the coordination environment of single atoms and their properties at the atomic level remains a considerable challenge.Herein,a facile waterassisted carbonization approach is developed to fabricate well-defined asymmetrically coordinated Co–N_(4)–O sites on biomass-derived carbon nanofiber(Co–N_(4)–O/NCF)for electromagnetic wave(EMW)absorption.In such nanofiber,one atomically dispersed Co site is coordinated with four N atoms in the graphene basal plane and one oxygen atom in the axial direction.In-depth experimental and theoretical studies reveal that the axial Co–O coordination breaks the charge distribution symmetry in the planar porphyrin-like Co–N_(4) structure,leading to significantly enhanced dielectric polarization loss relevant to the planar Co–N_(4) sites.Importantly,the film based on Co–N_(4)–O/NCF exhibits light weight,flexibility,excellent mechanical properties,great thermal insulating feature,and excellent EMW absorption with a reflection loss of−45.82 dB along with an effective absorption bandwidth of 4.8 GHz.The findings of this work offer insight into the relationships between the single-atom coordination environment and the dielectric performance,and the proposed strategy can be extended toward the engineering of asymmetrically coordinated single atoms for various applications.展开更多
The existence of a significant electron drift instability(EDI) in the Hall thruster is considered as one of the possible causes of the abnormal increase in axial electron mobility near the outlet of the channel. In re...The existence of a significant electron drift instability(EDI) in the Hall thruster is considered as one of the possible causes of the abnormal increase in axial electron mobility near the outlet of the channel. In recent years, extensive simulation research on the characteristics of EDI has been conducted, but the excitation mechanism and growth mechanism of EDI in linear stage and nonlinear stage remain unclear. In this work, a one-dimensional PIC model in the azimuthal direction of the thruster near-exit region is established to gain further insights into the mechanism of the EDI in detail, and the effects of different types of propellants on EDI characteristics are discussed. The changes in axial electron transport caused by EDI under different types of propellants and electromagnetic field strengths are also examined. The results indicate that EDI undergoes a short linear growth phase before transitioning to the nonlinear phase and finally reaching saturation through the ion Landau damping. The EDI drives a significant ion heating in the azimuthal direction through electron–ion friction before entering the quasi-steady state, which increases the axial mobility of the electrons. Using lighter atomic weight propellant can effectively suppress the oscillation amplitude of EDI, but it will increase the linear growth rate, frequency, and phase velocity of EDI. Compared with the classical mobility, the axial electron mobility under the EDI increases by three orders of magnitude, which is consistent with experimental phenomena. The change of propellant type is insufficient to significantly change the axial electron mobility. It is also found that the collisions between electrons and neutral gasescan significantly affect the axial electron mobility under the influence of EDI, and lead the strength of the electric field to increase and the strength of the magnetic field to decrease, thereby both effectively suppressing the axial transport of electrons.展开更多
Based on the generalized Hamilton's principle,the nonlinear governing equation of an axially functionally graded(AFG)pipe is established.The non-trivial equilibrium configuration is superposed by the modal functio...Based on the generalized Hamilton's principle,the nonlinear governing equation of an axially functionally graded(AFG)pipe is established.The non-trivial equilibrium configuration is superposed by the modal functions of a simply supported beam.Via the direct multi-scale method,the response and stability boundary to the pulsating fluid velocity are solved analytically and verified by the differential quadrature element method(DQEM).The influence of Young's modulus gradient on the parametric resonance is investigated in the subcritical and supercritical regions.In general,the pipe in the supercritical region is more sensitive to the pulsating excitation.The nonlinearity changes from hard to soft,and the non-trivial equilibrium configuration introduces more frequency components to the vibration.Besides,the increasing Young's modulus gradient improves the critical pulsating flow velocity of the parametric resonance,and further enhances the stability of the system.In addition,when the temperature increases along the axial direction,reducing the gradient parameter can enhance the response asymmetry.This work further complements the theoretical analysis of pipes conveying pulsating fluid.展开更多
Granite is usually composed of quartz,biotite,feldspar,and cracks,and the variation characteristics of these components could reflect the deformation and failure process of rock well.Taking granite as an example,the v...Granite is usually composed of quartz,biotite,feldspar,and cracks,and the variation characteristics of these components could reflect the deformation and failure process of rock well.Taking granite as an example,the video camera was used to record the deformation and failure process of rock.The distribution of meso-components in video images was then identified.The meso-components of rock failure precursors were also discussed.Moreover,a modified LSTM(long short-term memory method)based on SSA(sparrow search algorithm)was proposed to estimate the change of meso-components of rock failure precursor.It shows that the initiation and expansion of cracks are mainly caused by feldspar and quartz fracture,and when the quartz and feldspar exit the stress framework,rock failure occurs;the second large increase of crack area and the second large decrease of quartz or feldspar area may be used as a precursor of rock failure;the precursor time of rock failure based on meso-scopic components is about 4 s earlier than that observed by the naked eye;the modified LSTM network has the strongest estimation ability for quartz area change,followed by feldspar and biotite,and has the worst estimation ability for cracks;when using the modified LSTM network to predict the precursors of rock instability and failure,quartz and feldspar could be given priority.The results presented herein may provide reference in the investigation of rock failure mechanism.展开更多
AIM:To analyze the distribution of refractive status in school-age children with different corneal curvatures(CC)and the correlation between CC and refractive status.METHODS:A total of 2214 school-aged children of gra...AIM:To analyze the distribution of refractive status in school-age children with different corneal curvatures(CC)and the correlation between CC and refractive status.METHODS:A total of 2214 school-aged children of grade 4 in Hangzhou who were screened for school myopia were included.Uncorrected distance visual acuity(UCDVA),non-cycloplegic refraction,axial length(AL),horizontal and vertical corneal curvature(K1,K2)were measured and spherical equivalent(SE),corneal curvature radius(CCR)and axial length/corneal radius of curvature ratio(AL/CR)were calculated.UCDVA<5.0 and SE≤-0.50 D were classified as school-screening myopia.According to the different CCRs,the patients were divided into the lower corneal curvature(LCC)group(CCR≥7.92)and the higher corneal curvature(HCC)group(CCR<7.92).Each group was further divided into the normal AL subgroup and the long AL subgroup.The refractive parameters were compared to identify any differences between the two groups.RESULTS:Both SE and AL were greater in the LCC group(P=0.013,P<0.001).The prevalence of myopia was 38% in the LCC group and 44% in the HCC group(P<0.001).The proportion of children without screening myopia was higher in the LCC group(62%)than in the HCC group(56%).Among these children without screening myopia,the proportion of long AL in the LCC group(24%)was significantly higher than that in the HCC group(0.012%;P<0.001).The change of SE in the LCC group was less affected by the increase of AL than that in the HCC group.CONCLUSION:School-aged children in the LCC group have a lower incidence of screening myopia and longer AL.Low CC can mask SE reduction and AL growth to some extent,and the change of AL growth change more in children with low CC than high CC.Before the onset of myopia,its growth rate is even faster than that after the onset of myopia.展开更多
Owing to the particularity of a polyester fiber material,the polyester mooring undergoes large axial tensile deformation over long-term use.Large axial tensile deformation significantly impacts the dynamic response of...Owing to the particularity of a polyester fiber material,the polyester mooring undergoes large axial tensile deformation over long-term use.Large axial tensile deformation significantly impacts the dynamic response of the mooring system.In addition,the degrees of large axial tension caused by different elastic moduli are also different,and the force on the mooring line is also different.Therefore,it is of great significance to study the influence of elastic modulus on the dynamic results of the mooring systems under large axial tension.Conventional numerical software fails to consider the axial tension deformation of the mooring.Based on the theory of slender rods,this paper derives the formula for large axial tension using the method of overall coordinates and overall slope coordinates and provides the calculation programs.Considering a polyester mooring system as an example,the calculation program and numerical software are used to calculate and compare the static and dynamic analyses to verify the reliability of the calculation program.To make the force change of the mooring obvious,the elastic moduli of three different orders of magnitude are compared and analyzed,and the dynamic response results after large axial tension are compared.This study concludes that the change in the elastic modulus of the polyester mooring changes the result of the vertex tension by generating an axial tension.The smaller the elastic modulus,the larger the forced oscillation motion amplitude of the top point of the mooring line,the more obvious the axial tension phenomenon,and the smaller the force on the top of the polyester mooring.展开更多
AIM:To investigate the impact of multifocal gas permeable contact lens(MFGPCL)in various add power and distance/near area allocation on short-term changes of choroidal thickness(ChT),axial length(AL),and retinal defoc...AIM:To investigate the impact of multifocal gas permeable contact lens(MFGPCL)in various add power and distance/near area allocation on short-term changes of choroidal thickness(ChT),axial length(AL),and retinal defocus profile in young adults.METHODS:Seventeen young adults(2 males and 15 females;age 23.17±4.48y)were randomly assigned to wear two designs binocularly with a one-week washout period in between.Total of four MFGPCL designs were assessed.All designs were distance-center that varied in two add power(+1.50 and 3.00 D)and/or two distance zone(DZ)diameters(1.50 and 3.00 mm;design A:DZ 1.5/add 3.0,B:DZ 1.5/add 1.5,C:DZ 3.0/add 3.0,D:DZ 3.0/add 1.5).ChT,AL,and peripheral refraction data were collected on each subject at baseline,on days 1 and 7 of MFGPCL daily wear.ChT was assessed in four quadrants using a spectraldomain optical coherence tomography.RESULTS:AL was shortened by-26±44μm with lens C,-18±27μm with lens D,-13±29μm with lens A,and-8±30μm with lens B(all P<0.05).A significant overall increase in ChT was observed with all 4 designs(lens A:+6±6μm,B:+3±7μm,C:+8±7μm,and D:+8±7μm).Temporal and superior choroid exhibited more choroidal thickening associated with MFGPCL.All designs induced significant relative peripheral myopia(RPM)beyond the central 20o across the horizontal meridian in both nasal and temporal fields(P<0.05).CONCLUSION:MFGPCLs show a significant influence on ChT and AL,which are associated with significant increase in RPM after short-term wear.The reliability and feasibility of quantifying short-term changes in ChT support its use as a promising marker for the long-term efficacy of myopia-controlling treatments.展开更多
AIM:To investigate the clinical features of the ocular surface in patients with different degrees of myopia.METHODS:A cross-sectional study was conducted involving 122 participants with myopia in Beijing Tongren Hospi...AIM:To investigate the clinical features of the ocular surface in patients with different degrees of myopia.METHODS:A cross-sectional study was conducted involving 122 participants with myopia in Beijing Tongren Hospital from February to June,2023.After completing the Ocular Surface Disease Index(OSDI)score scale,measurements were taken for refraction,biometric parameters and ocular surface parameters.The prevalence,severity and related parameters of the dry eye among different groups based on axial length(AL)were compared.Correlation analysis was performed between ocular surface parameters and refraction/biometric measurement parameters.RESULTS:Statistically significant differences were observed in refractive error,corneal thickness,anterior chamber depth,and subfoveal choroidal thickness among the groups(all P<0.05).With the increase in AL,the incidence and severity of dry eye increased significantly(P<0.05).Moreover,the tear film break-up time(BUT)shortened(P<0.05),and the corneal fluorescein staining(CFS)points increased significantly(P<0.05).OSDI scores were positively correlated with AL and spherical equivalent(SE;both P<0.05);BUT was negatively correlated with AL,SE,and corneal astigmatism(AST;all P<0.05);Schirmer I test(SIT)results were negatively correlated with AL and SE(both P<0.05).CONCLUSION:AL elongation is a risk factor for dry eye onset in myopic participants.The longer the AL,the more severe the dry eye is,with the increased CFS spots and tear film instability.Additionally,SE and AST exhibit negative correlations with dry eye symptom scores and ocular surface parameters.展开更多
The particle residence time distribution(RTD)and axial dispersion coefficient are key parameters for the design and operation of a pressurized circulating fluidized bed(PCFB).In this study,the effects of pressure(0.1-...The particle residence time distribution(RTD)and axial dispersion coefficient are key parameters for the design and operation of a pressurized circulating fluidized bed(PCFB).In this study,the effects of pressure(0.1-0.6 MPa),fluidizing gas velocity(2-7 m·s^(-1)),and solid circulation rate(10-90 kg·m^(-2)·s^(-1))on particle RTD and axial dispersion coefficient in a PCFB are numerically investigated based on the multiphase particle-in-cell(MP-PIC)method.The details of the gas-solid flow behaviors of PCFB are revealed.Based on the gas-solid flow pattern,the particles tend to move more orderly under elevated pressures.With an increase in either fluidizing gas velocity or solid circulation rate,the mean residence time of particles decreases while the axial dispersion coefficient increases.With an increase in pressure,the core-annulus flow is strengthened,which leads to a wider shape of the particle RTD curve and a larger mean particle residence time.The back-mixing of particles increases with increasing pressure,resulting in an increase in the axial dispersion coefficient.展开更多
Field reversed configuration(FRC)is widely considered as an ideal target plasma for magnetoinertial fusion.However,its confinement and stability,both proportional to the radius,will deteriorate inevitably during radia...Field reversed configuration(FRC)is widely considered as an ideal target plasma for magnetoinertial fusion.However,its confinement and stability,both proportional to the radius,will deteriorate inevitably during radial compression.Hence,we propose a new fusion approach based on axial compression of a large-sized FRC.The axial compression can be made by plasma jets or plasmoids converging onto the axial ends of the FRC.The parameter space that can reach the ignition condition while preserving the FRC's overall quality is studied using a numerical model based on different FRC confinement scalings.It is found that ignition is possible for a large FRC that can be achieved with the current FRC formation techniques if compression ratio is greater than 50.A more realistic compression is to combine axial with moderate radial compression,which is also presented and calculated in this work.展开更多
●AIM:To assess effectivity and safety of trifocal intraocular lenses(IOLs)and capsular tension rings in treating cataract patients with axial high myopia.●METHODS:A prospective nonrandomized controlled clinical tria...●AIM:To assess effectivity and safety of trifocal intraocular lenses(IOLs)and capsular tension rings in treating cataract patients with axial high myopia.●METHODS:A prospective nonrandomized controlled clinical trial was conducted.Totally 98 eyes(74 patients)who underwent femtosecond laser-assisted cataract surgery(FLACS)with trifocal IOLs were enrolled in the study and followed up for 2y after surgery:46 eyes(33 patients)with capsular tension ring implantation in the long axial lengths(AL)group(26<AL<29 mm)and 52 eyes(41 patients)in the normal AL group(22<AL<24.5 mm).Postoperative outcomes about effectivity and safety,including the subjective and objective visual quality,and postoperative complications were assessed.●RESULTS:Uncorrected distance visual acuity at 5 m and uncorrected intermediate visual acuity at 60 and 80 cm in the long AL group were significantly worse than those in the normal AL group at 3mo postoperatively(P<0.05).The differences in reading speed,spectacle independence and potential visual complaints between the two groups were not statistically significant(P>0.05).The dysfunctional lens index and total modulation transfer function(MTF)average height were similar between the two groups.The postoperative internal coma aberrations in the axial high myopia eyes were significantly higher than that in the normal AL group(P<0.05).The total satisfaction score in the long AL group(91.32±2.76)was slightly higher than that in the normal AL group(90.36±3.47),but there was no difference(P=0.136).A statistically negative correlation was found between corrected distance visual acuity(CDVA)and dysfunctional lens index(r=-0.382,P=0.009),and between CDVA and the total MTF average height(r=-0.374,P=0.01).But there was no significant correlation between CDVA and total satisfaction score(r=0.059,P=0.696).Postoperative complications mainly presented as posterior capsular opacity(PCO),retinal detachment and cystoid macular edema.There was no difference in the incidence of fundus disease(6.5%vs 3.8%,P=0.663)or PCO(17.4%vs 7.7%,P=0.217)between the two groups at two years.●CONCLUSION:The utilization of trifocal IOL and capsular tension ring implantation is beneficial for cataract patients with axial high myopia undergoing FLACS.This approach not only ensures excellent subjective feelings and objective visual quality,but also does not increase the incidence of postoperative complications.展开更多
Nano-computed tomography(Nano-CT)is an emerging,high-resolution imaging technique.However,due to their low-light properties,tabletop Nano-CT has to be scanned under long exposure conditions,which the scanning process ...Nano-computed tomography(Nano-CT)is an emerging,high-resolution imaging technique.However,due to their low-light properties,tabletop Nano-CT has to be scanned under long exposure conditions,which the scanning process is time-consuming.For 3D reconstruction data,this paper proposed a lightweight 3D noise reduction method for desktop-level Nano-CT called AAD-ResNet(Axial Attention DeNoise ResNet).The network is framed by theU-net structure.The encoder and decoder are incorporated with the proposed 3D axial attention mechanism and residual dense block.Each layer of the residual dense block can directly access the features of the previous layer,which reduces the redundancy of parameters and improves the efficiency of network training.The 3D axial attention mechanism enhances the correlation between 3D information in the training process and captures the long-distance dependence.It can improve the noise reduction effect and avoid the loss of image structure details.Experimental results show that the network can effectively improve the image quality of a 0.1-s exposure scan to a level close to a 3-s exposure,significantly shortening the sample scanning time.展开更多
AIM:To compare the efficacy of pars plana vitrectomy(PPV)combined with internal limiting membrane(ILM)and silicone oil or sterile air tamponade for the treatment of myopic foveoschisis(MF)in highly myopic eyes.METHODS...AIM:To compare the efficacy of pars plana vitrectomy(PPV)combined with internal limiting membrane(ILM)and silicone oil or sterile air tamponade for the treatment of myopic foveoschisis(MF)in highly myopic eyes.METHODS:This retrospective study included 48 myopic eyes of 40 patients with MF and axial lengths(ALs)ranging from 26-32 mm treated between January 2020 and January 2022.All patients were underwent PPV combined with ILM peeling followed by sterile air or silicone oil tamponade and followed up at least 12mo.Based on the features on spectral-domain optical coherence tomography(SD-OCT),the eyes were divided into the MF-only group(Group A,n=15 eyes),MF with central foveal detachment group(Group B,n=20 eyes),and MF with lamellar macular hole group(Group C,n=13 eyes).According to AL,eyes were further divided into three groups:Group D(26.01-28.00 mm,n=12 eyes),Group E(28.01-30.00 mm,n=26 eyes),and Group F(30.01-32.00 mm,n=10 eyes).The best-corrected visual acuity(BCVA),central foveal thickness(CFT),and complications were recorded.RESULTS:The patients included 16 males and 24 females with the mean age of 56±9.82y.The BCVA and CFT improved in all groups after surgery(P<0.01),while there was no significant difference of the CFT in Group A,B,and C postoperatively(P>0.05).The intergroup differences of BCVA and CFT postoperatively were statistically significant in Group D,E,and F.Twenty eyes were injected with sterile air,and 28 eyes were injected with silicone oil for tamponade based on the AL.However,there was no statistically significant difference among Groups D,E,and F in terms of the results of sterile air or silicone oil tamponade.The mean recovery time was 5.9mo for MF patients subjected to silicone oil tamponade and 7.7mo for patients subjected to sterile air tamponade,and the difference was not statistically significant.CONCLUSION:PPV and ILM peeling combined with silicone oil or sterile air tamponade can achieve good results for MF in highly myopic eyes with ALs≤32 mm.展开更多
基金Supported by Education Department Foundation of Sichuan Province(No.15ZA0262).
文摘AIM:To present the 1-year results of a prospective cohort study investigating the efficacy,potential mechanism,and safety of orthokeratology(ortho-k)with different back optic zone diameters(BOZD)for myopia control in children.METHODS:This randomized clinical study was performed between Dec.2020 and Dec.2021.Participants were randomly assigned to three groups wearing ortho-k:5 mm BOZD(5-MM group),5.5 mm BOZD(5.5-MM group),and 6 mm BOZD(6-MM group).The 1-year data were recorded,including axial length,relative peripheral refraction(RPR,measured by multispectral refractive topography,MRT),and visual quality.The contrast sensitivity(CS)was evaluated by CSV-1000 instrument with spatial frequencies of 3,6,12,and 18 cycles/degree(c/d);the corneal higher-order aberrations(HOAs)were measured by iTrace aberration analyzer.The one-way ANOVA was performed to assess the differences between the three groups.The correlation between the change in AL and RPR was calculated by Pearson’s correlation coefficient.RESULTS:The 1-year results of 20,21,and 21 subjects in the 5-MM,5.5-MM,and 6-MM groups,respectively,were presented.There were no statistical differences in baseline age,sex,or ocular parameters between the three groups(all P>0.05).At the 1-year visit,the 5-MM group had lower axial elongation than the 6-MM group(0.07±0.09 vs 0.18±0.11 mm,P=0.001).The 5-MM group had more myopic total RPR(TRPR,P=0.014),with RPR in the 15°–30°(RPR 15–30,P=0.015),30°–45°(RPR 30–45,P=0.011),temporal(RPR-T,P=0.008),and nasal area(RPR-N,P<0.001)than the 6-MM group.RPR 15–30 in the 5.5-MM group was more myopic than that in the 6-MM group(P=0.002),and RPR-N in the 5-MM group was more myopic than that in the 5.5-MM group(P<0.001).There were positive correlations between the axial elongation and the change in TRPR(r=0.756,P<0.001),RPR 15–30(r=0.364,P=0.004),RPR 30–45(r=0.306,P=0.016),and RPR-N(r=0.253,P=0.047).The CS decreased at 3 c/d(P<0.001),and the corneal HOAs increased in the 5-MM group(P=0.030).CONCLUSION:Ortho-k with 5 mm BOZD can control myopia progression more effectively.The mechanism may be associated with greater myopic shifts in RPR.
基金supported by the Natural Science Foundation of China(52122811).
文摘Displacement control algorithms commonly used to evaluate axial force-bending moment(PM)diagrams may lead to incorrect interpretations of the strength envelopes for asymmetric sections.This paper aims to offer valuable insights by comparing existing displacement control algorithms with a newly proposed force control algorithm.The main focus is on the PM diagrams of three example sections that exhibit varying degrees of asymmetry.The comparative study indicates that conventional displacement control algorithms inevitably introduce non-zero out-of-plane bending moments.The reported PM diagram in such cases erroneously neglects the out-of-plane moment and fails to represent the strength envelope accurately.This oversight results in significant and unconservative errors when verifying the strength of asymmetric sections.
基金funded by the National Natural Science Foundation of China(Nos.42077228,52174085)。
文摘Frequent rockburst disasters in deep-buried engineering projects severely impact construction. To explore the influence of axial stress on rockburst in deep-buried tunnels, large-scale true triaxial rockburst experiments were conducted under four different axial stress ratio conditions (ηt, axial loading stress/vertical loading stress) using a self-developed true triaxial loading device under the condition of "pre-loading before excavation". The influence of axial stress on the rockburst process and failure characteristics in deep tunnels was studied using a combination of real-time video monitoring, rockburst debris sieving, and acoustic emission monitoring. The results indicate: (1) all four specimens subjected to different axial stress ratio loading conditions exhibited three stages of macroscopic failure: small particle ejection, flake spalling, and large fragment ejection. Ultimately, "V"-shaped notches appeared on both sides of the tunnel. (2) The failure stress, fragment volume, and fragment size distribution of the rockburst specimens exhibited a clear two-stage failure characteristic with increasing axial stress ratio. In the lower axial stress ratio stage (ηt ≤ 0.7), the increase in the axial stress ratio enhances lateral confinement, thereby increasing the crack initiation strength of the surrounding rock, inhibiting crack formation and propagation, and thus suppressing damage to the surrounding rock of the tunnel. In the higher axial stress ratio stage (ηt > 0.7), the increase in axial stress ratio makes the Poisson effect of the surrounding rock more pronounced, promoting the generation and propagation of cracks along the tunnel axis direction, thereby promoting damage to the surrounding rock. (3) Based on the analysis of acoustic emission parameters (fracture properties), it can be concluded that in the lower axial stress ratio stage (ηt ≤ 0.7), an increase in the axial stress ratio leads to a higher proportion of shear fracture in rockburst damage. Conversely, in the higher axial stress ratio stage (ηt > 0.7), the increase in axial stress ratio gradually reduces the proportion of shear fracture in rockburst damage.
文摘Given their numerous functional and architectural benefits,such as improved bearing capacity and increased resistance to elastic instability modes,cold-formed steel(CFS)built-up sections have become increasingly developed and used in recent years,particularly in the construction industry.This paper presents an analytical and numerical study of assembled CFS two single channel-shaped columns with different slenderness and configurations(backto-back,face-to-face,and box).These columns were joined by double-row rivets for the back-to-back and box configurations,whereas they were welded together for the face-to-face design.The built-up columns were filled with ordinary concrete of good strength.Finite element models were applied,using ABAQUS software,to assess mechanical performance and study the influence of assembly techniques on the behavior of cold-formed columns under axial compression.Analytical approaches based on Eurocode 3 and Eurocode 4 recommendations for un-filled and concrete-filled columns respectively were followed for the numerical analysis,and concrete confinement effects were also considered per American Concrete Institute(ACI)standards for face-to-face and box configurations.The obtained results indicated a good correlation between the numerical results and the proposed analytical methodology which did not exceed 8%.The failure modes showed that the columns failed due to instabilities such as local and global buckling.
文摘AIM:To elucidate whether differences exist in the impact on retarding the elongation of axial length(AL)among children with myopia when utilizing orthokeratology(ortho-k)lenses employing the corneal refractive therapy(CRT)design versus those employing the vision shaping treatment(VST)design.METHODS:This retrospective clinical trial aimed to collect and analyze AL data from individuals who wore ortho-k lenses for three years.A total of 654 subjects were enrolled and prescribed one of the three specific brands of ortho-k lenses:CRT,Euclid,and Mouldway.The study’s primary focus was to compare the rates of AL elongation and myopic progression across these three brands of ortho-k lenses.RESULTS:In the 3-year follow-up,the AL elongation exhibited variations of 0.73±0.36 mm in the CRT lens group,0.59±0.37 mm in the Euclid lens group,and 0.63±0.38 mm in the Mouldway lens group.A noteworthy disparity emerged between the CRT and Mouldway groups(P<0.01),as well as between the CRT and Euclid groups(P<0.001).Additionally,it was observed that 32.1%of participants who wore CRT lenses experienced a decelerated progression of myopia,in contrast to 47.2%in the Euclid group and 44.4%in the Mouldway group.Statistical analyses revealed a statistically significant distinction between the CRT and Euclid groups(P<0.01),and similarly,the CRT group demonstrated a statistically significant difference when compared to the Mouldway group(P<0.05).CONCLUSION:Ortho-k lenses represent a pragmatic strategy for mitigating the advancement of myopia.In contradistinction to ortho-k lenses utilizing the CRT design,those employing the VST design exhibited a more favorable impact regarding retarding AL elongation.
文摘This narrative review aimed to have an algorithmic approach to microphthalmos by a systematic search.The definition can be related to a number of special phenotypes.In the more challenging cases of complex microphthalmos,relative anterior microphthalmos,and nanophthalmos,the surgeon can approach these cases more safely if they have a deep understanding of the anatomical variations and ideal formulae for intraocular lens computation and knows how to avoid intra-and post-operative complications.In this article,we review the criteria by which we recognize and describe pre-,intra-,and post-operative considerations,as well as discuss the ideal intraocular lenses for microphthalmos,given the intricate varieties of small eye phenotypes.
基金supported in part by the National Natural Science Foundation of China under Grant 62062061/in part by the Major Project Cultivation Fund of Xizang Minzu University under Grant 324112300447.
文摘Recently,deep learning-based image inpainting methods have made great strides in reconstructing damaged regions.However,these methods often struggle to produce satisfactory results when dealing with missing images with large holes,leading to distortions in the structure and blurring of textures.To address these problems,we combine the advantages of transformers and convolutions to propose an image inpainting method that incorporates edge priors and attention mechanisms.The proposed method aims to improve the results of inpainting large holes in images by enhancing the accuracy of structure restoration and the ability to recover texture details.This method divides the inpainting task into two phases:edge prediction and image inpainting.Specifically,in the edge prediction phase,a transformer architecture is designed to combine axial attention with standard self-attention.This design enhances the extraction capability of global structural features and location awareness.It also balances the complexity of self-attention operations,resulting in accurate prediction of the edge structure in the defective region.In the image inpainting phase,a multi-scale fusion attention module is introduced.This module makes full use of multi-level distant features and enhances local pixel continuity,thereby significantly improving the quality of image inpainting.To evaluate the performance of our method.comparative experiments are conducted on several datasets,including CelebA,Places2,and Facade.Quantitative experiments show that our method outperforms the other mainstream methods.Specifically,it improves Peak Signal-to-Noise Ratio(PSNR)and Structure Similarity Index Measure(SSIM)by 1.141~3.234 db and 0.083~0.235,respectively.Moreover,it reduces Learning Perceptual Image Patch Similarity(LPIPS)and Mean Absolute Error(MAE)by 0.0347~0.1753 and 0.0104~0.0402,respectively.Qualitative experiments reveal that our method excels at reconstructing images with complete structural information and clear texture details.Furthermore,our model exhibits impressive performance in terms of the number of parameters,memory cost,and testing time.
基金supported by the National Natural Science Foundation of China(Grant No.52372283)China Postdoctoral Science Foundation(Grant No.2023M730826)+1 种基金Heilongjiang Postdoctoral Fund(Grant No.LBH-Z23121)Postdoctoral Fellowship Program of CPSF(Grant No.GZC20233425).
文摘Single-atom materials have demonstrated attractive physicochemical characteristics.However,understanding the relationships between the coordination environment of single atoms and their properties at the atomic level remains a considerable challenge.Herein,a facile waterassisted carbonization approach is developed to fabricate well-defined asymmetrically coordinated Co–N_(4)–O sites on biomass-derived carbon nanofiber(Co–N_(4)–O/NCF)for electromagnetic wave(EMW)absorption.In such nanofiber,one atomically dispersed Co site is coordinated with four N atoms in the graphene basal plane and one oxygen atom in the axial direction.In-depth experimental and theoretical studies reveal that the axial Co–O coordination breaks the charge distribution symmetry in the planar porphyrin-like Co–N_(4) structure,leading to significantly enhanced dielectric polarization loss relevant to the planar Co–N_(4) sites.Importantly,the film based on Co–N_(4)–O/NCF exhibits light weight,flexibility,excellent mechanical properties,great thermal insulating feature,and excellent EMW absorption with a reflection loss of−45.82 dB along with an effective absorption bandwidth of 4.8 GHz.The findings of this work offer insight into the relationships between the single-atom coordination environment and the dielectric performance,and the proposed strategy can be extended toward the engineering of asymmetrically coordinated single atoms for various applications.
基金Project supported by the National Natural Science Foundation of China (Grant Nos.11975062 and 11605021)the Fundamental Research Funds for the Central Universities (Grant No.3132023192)。
文摘The existence of a significant electron drift instability(EDI) in the Hall thruster is considered as one of the possible causes of the abnormal increase in axial electron mobility near the outlet of the channel. In recent years, extensive simulation research on the characteristics of EDI has been conducted, but the excitation mechanism and growth mechanism of EDI in linear stage and nonlinear stage remain unclear. In this work, a one-dimensional PIC model in the azimuthal direction of the thruster near-exit region is established to gain further insights into the mechanism of the EDI in detail, and the effects of different types of propellants on EDI characteristics are discussed. The changes in axial electron transport caused by EDI under different types of propellants and electromagnetic field strengths are also examined. The results indicate that EDI undergoes a short linear growth phase before transitioning to the nonlinear phase and finally reaching saturation through the ion Landau damping. The EDI drives a significant ion heating in the azimuthal direction through electron–ion friction before entering the quasi-steady state, which increases the axial mobility of the electrons. Using lighter atomic weight propellant can effectively suppress the oscillation amplitude of EDI, but it will increase the linear growth rate, frequency, and phase velocity of EDI. Compared with the classical mobility, the axial electron mobility under the EDI increases by three orders of magnitude, which is consistent with experimental phenomena. The change of propellant type is insufficient to significantly change the axial electron mobility. It is also found that the collisions between electrons and neutral gasescan significantly affect the axial electron mobility under the influence of EDI, and lead the strength of the electric field to increase and the strength of the magnetic field to decrease, thereby both effectively suppressing the axial transport of electrons.
基金Project supported by the National Natural Science Foundation of China (Nos.12002195 and 12372015)the National Science Fund for Distinguished Young Scholars of China (No.12025204)the Program of Shanghai Municipal Education Commission of China (No.2019-01-07-00-09-E00018)。
文摘Based on the generalized Hamilton's principle,the nonlinear governing equation of an axially functionally graded(AFG)pipe is established.The non-trivial equilibrium configuration is superposed by the modal functions of a simply supported beam.Via the direct multi-scale method,the response and stability boundary to the pulsating fluid velocity are solved analytically and verified by the differential quadrature element method(DQEM).The influence of Young's modulus gradient on the parametric resonance is investigated in the subcritical and supercritical regions.In general,the pipe in the supercritical region is more sensitive to the pulsating excitation.The nonlinearity changes from hard to soft,and the non-trivial equilibrium configuration introduces more frequency components to the vibration.Besides,the increasing Young's modulus gradient improves the critical pulsating flow velocity of the parametric resonance,and further enhances the stability of the system.In addition,when the temperature increases along the axial direction,reducing the gradient parameter can enhance the response asymmetry.This work further complements the theoretical analysis of pipes conveying pulsating fluid.
基金Project(41472254)supported by the National Natural Science Foundation of China。
文摘Granite is usually composed of quartz,biotite,feldspar,and cracks,and the variation characteristics of these components could reflect the deformation and failure process of rock well.Taking granite as an example,the video camera was used to record the deformation and failure process of rock.The distribution of meso-components in video images was then identified.The meso-components of rock failure precursors were also discussed.Moreover,a modified LSTM(long short-term memory method)based on SSA(sparrow search algorithm)was proposed to estimate the change of meso-components of rock failure precursor.It shows that the initiation and expansion of cracks are mainly caused by feldspar and quartz fracture,and when the quartz and feldspar exit the stress framework,rock failure occurs;the second large increase of crack area and the second large decrease of quartz or feldspar area may be used as a precursor of rock failure;the precursor time of rock failure based on meso-scopic components is about 4 s earlier than that observed by the naked eye;the modified LSTM network has the strongest estimation ability for quartz area change,followed by feldspar and biotite,and has the worst estimation ability for cracks;when using the modified LSTM network to predict the precursors of rock instability and failure,quartz and feldspar could be given priority.The results presented herein may provide reference in the investigation of rock failure mechanism.
基金Supported by Key Research and Development Projects of Zhejiang Science and Technology Plan(No.2021C03103).
文摘AIM:To analyze the distribution of refractive status in school-age children with different corneal curvatures(CC)and the correlation between CC and refractive status.METHODS:A total of 2214 school-aged children of grade 4 in Hangzhou who were screened for school myopia were included.Uncorrected distance visual acuity(UCDVA),non-cycloplegic refraction,axial length(AL),horizontal and vertical corneal curvature(K1,K2)were measured and spherical equivalent(SE),corneal curvature radius(CCR)and axial length/corneal radius of curvature ratio(AL/CR)were calculated.UCDVA<5.0 and SE≤-0.50 D were classified as school-screening myopia.According to the different CCRs,the patients were divided into the lower corneal curvature(LCC)group(CCR≥7.92)and the higher corneal curvature(HCC)group(CCR<7.92).Each group was further divided into the normal AL subgroup and the long AL subgroup.The refractive parameters were compared to identify any differences between the two groups.RESULTS:Both SE and AL were greater in the LCC group(P=0.013,P<0.001).The prevalence of myopia was 38% in the LCC group and 44% in the HCC group(P<0.001).The proportion of children without screening myopia was higher in the LCC group(62%)than in the HCC group(56%).Among these children without screening myopia,the proportion of long AL in the LCC group(24%)was significantly higher than that in the HCC group(0.012%;P<0.001).The change of SE in the LCC group was less affected by the increase of AL than that in the HCC group.CONCLUSION:School-aged children in the LCC group have a lower incidence of screening myopia and longer AL.Low CC can mask SE reduction and AL growth to some extent,and the change of AL growth change more in children with low CC than high CC.Before the onset of myopia,its growth rate is even faster than that after the onset of myopia.
基金Supported by the Specialized Research Project for LS17-2 Semi-submersible Production Platform(LSZX-2020-HN-05-0405)the Engineering Development Program of Deepwater Semisubmersible Production Storage and Unloading Platform of China(SSBQ-2020-HN-02-04)。
文摘Owing to the particularity of a polyester fiber material,the polyester mooring undergoes large axial tensile deformation over long-term use.Large axial tensile deformation significantly impacts the dynamic response of the mooring system.In addition,the degrees of large axial tension caused by different elastic moduli are also different,and the force on the mooring line is also different.Therefore,it is of great significance to study the influence of elastic modulus on the dynamic results of the mooring systems under large axial tension.Conventional numerical software fails to consider the axial tension deformation of the mooring.Based on the theory of slender rods,this paper derives the formula for large axial tension using the method of overall coordinates and overall slope coordinates and provides the calculation programs.Considering a polyester mooring system as an example,the calculation program and numerical software are used to calculate and compare the static and dynamic analyses to verify the reliability of the calculation program.To make the force change of the mooring obvious,the elastic moduli of three different orders of magnitude are compared and analyzed,and the dynamic response results after large axial tension are compared.This study concludes that the change in the elastic modulus of the polyester mooring changes the result of the vertex tension by generating an axial tension.The smaller the elastic modulus,the larger the forced oscillation motion amplitude of the top point of the mooring line,the more obvious the axial tension phenomenon,and the smaller the force on the top of the polyester mooring.
基金the Deputyship for Research and Innovation,Ministry of Education in Saudi Arabia for funding this research work through the project(No.IFKSUOR3-433-1)。
文摘AIM:To investigate the impact of multifocal gas permeable contact lens(MFGPCL)in various add power and distance/near area allocation on short-term changes of choroidal thickness(ChT),axial length(AL),and retinal defocus profile in young adults.METHODS:Seventeen young adults(2 males and 15 females;age 23.17±4.48y)were randomly assigned to wear two designs binocularly with a one-week washout period in between.Total of four MFGPCL designs were assessed.All designs were distance-center that varied in two add power(+1.50 and 3.00 D)and/or two distance zone(DZ)diameters(1.50 and 3.00 mm;design A:DZ 1.5/add 3.0,B:DZ 1.5/add 1.5,C:DZ 3.0/add 3.0,D:DZ 3.0/add 1.5).ChT,AL,and peripheral refraction data were collected on each subject at baseline,on days 1 and 7 of MFGPCL daily wear.ChT was assessed in four quadrants using a spectraldomain optical coherence tomography.RESULTS:AL was shortened by-26±44μm with lens C,-18±27μm with lens D,-13±29μm with lens A,and-8±30μm with lens B(all P<0.05).A significant overall increase in ChT was observed with all 4 designs(lens A:+6±6μm,B:+3±7μm,C:+8±7μm,and D:+8±7μm).Temporal and superior choroid exhibited more choroidal thickening associated with MFGPCL.All designs induced significant relative peripheral myopia(RPM)beyond the central 20o across the horizontal meridian in both nasal and temporal fields(P<0.05).CONCLUSION:MFGPCLs show a significant influence on ChT and AL,which are associated with significant increase in RPM after short-term wear.The reliability and feasibility of quantifying short-term changes in ChT support its use as a promising marker for the long-term efficacy of myopia-controlling treatments.
基金Supported by the Capital Health Development Scientific Research.
文摘AIM:To investigate the clinical features of the ocular surface in patients with different degrees of myopia.METHODS:A cross-sectional study was conducted involving 122 participants with myopia in Beijing Tongren Hospital from February to June,2023.After completing the Ocular Surface Disease Index(OSDI)score scale,measurements were taken for refraction,biometric parameters and ocular surface parameters.The prevalence,severity and related parameters of the dry eye among different groups based on axial length(AL)were compared.Correlation analysis was performed between ocular surface parameters and refraction/biometric measurement parameters.RESULTS:Statistically significant differences were observed in refractive error,corneal thickness,anterior chamber depth,and subfoveal choroidal thickness among the groups(all P<0.05).With the increase in AL,the incidence and severity of dry eye increased significantly(P<0.05).Moreover,the tear film break-up time(BUT)shortened(P<0.05),and the corneal fluorescein staining(CFS)points increased significantly(P<0.05).OSDI scores were positively correlated with AL and spherical equivalent(SE;both P<0.05);BUT was negatively correlated with AL,SE,and corneal astigmatism(AST;all P<0.05);Schirmer I test(SIT)results were negatively correlated with AL and SE(both P<0.05).CONCLUSION:AL elongation is a risk factor for dry eye onset in myopic participants.The longer the AL,the more severe the dry eye is,with the increased CFS spots and tear film instability.Additionally,SE and AST exhibit negative correlations with dry eye symptom scores and ocular surface parameters.
基金Financial support of this work by National Natural Science Foundation of China(51976037)。
文摘The particle residence time distribution(RTD)and axial dispersion coefficient are key parameters for the design and operation of a pressurized circulating fluidized bed(PCFB).In this study,the effects of pressure(0.1-0.6 MPa),fluidizing gas velocity(2-7 m·s^(-1)),and solid circulation rate(10-90 kg·m^(-2)·s^(-1))on particle RTD and axial dispersion coefficient in a PCFB are numerically investigated based on the multiphase particle-in-cell(MP-PIC)method.The details of the gas-solid flow behaviors of PCFB are revealed.Based on the gas-solid flow pattern,the particles tend to move more orderly under elevated pressures.With an increase in either fluidizing gas velocity or solid circulation rate,the mean residence time of particles decreases while the axial dispersion coefficient increases.With an increase in pressure,the core-annulus flow is strengthened,which leads to a wider shape of the particle RTD curve and a larger mean particle residence time.The back-mixing of particles increases with increasing pressure,resulting in an increase in the axial dispersion coefficient.
基金supported by National Natural Science Foundation of China(No.12175226)。
文摘Field reversed configuration(FRC)is widely considered as an ideal target plasma for magnetoinertial fusion.However,its confinement and stability,both proportional to the radius,will deteriorate inevitably during radial compression.Hence,we propose a new fusion approach based on axial compression of a large-sized FRC.The axial compression can be made by plasma jets or plasmoids converging onto the axial ends of the FRC.The parameter space that can reach the ignition condition while preserving the FRC's overall quality is studied using a numerical model based on different FRC confinement scalings.It is found that ignition is possible for a large FRC that can be achieved with the current FRC formation techniques if compression ratio is greater than 50.A more realistic compression is to combine axial with moderate radial compression,which is also presented and calculated in this work.
文摘●AIM:To assess effectivity and safety of trifocal intraocular lenses(IOLs)and capsular tension rings in treating cataract patients with axial high myopia.●METHODS:A prospective nonrandomized controlled clinical trial was conducted.Totally 98 eyes(74 patients)who underwent femtosecond laser-assisted cataract surgery(FLACS)with trifocal IOLs were enrolled in the study and followed up for 2y after surgery:46 eyes(33 patients)with capsular tension ring implantation in the long axial lengths(AL)group(26<AL<29 mm)and 52 eyes(41 patients)in the normal AL group(22<AL<24.5 mm).Postoperative outcomes about effectivity and safety,including the subjective and objective visual quality,and postoperative complications were assessed.●RESULTS:Uncorrected distance visual acuity at 5 m and uncorrected intermediate visual acuity at 60 and 80 cm in the long AL group were significantly worse than those in the normal AL group at 3mo postoperatively(P<0.05).The differences in reading speed,spectacle independence and potential visual complaints between the two groups were not statistically significant(P>0.05).The dysfunctional lens index and total modulation transfer function(MTF)average height were similar between the two groups.The postoperative internal coma aberrations in the axial high myopia eyes were significantly higher than that in the normal AL group(P<0.05).The total satisfaction score in the long AL group(91.32±2.76)was slightly higher than that in the normal AL group(90.36±3.47),but there was no difference(P=0.136).A statistically negative correlation was found between corrected distance visual acuity(CDVA)and dysfunctional lens index(r=-0.382,P=0.009),and between CDVA and the total MTF average height(r=-0.374,P=0.01).But there was no significant correlation between CDVA and total satisfaction score(r=0.059,P=0.696).Postoperative complications mainly presented as posterior capsular opacity(PCO),retinal detachment and cystoid macular edema.There was no difference in the incidence of fundus disease(6.5%vs 3.8%,P=0.663)or PCO(17.4%vs 7.7%,P=0.217)between the two groups at two years.●CONCLUSION:The utilization of trifocal IOL and capsular tension ring implantation is beneficial for cataract patients with axial high myopia undergoing FLACS.This approach not only ensures excellent subjective feelings and objective visual quality,but also does not increase the incidence of postoperative complications.
基金supported by the National Natural Science Foundation of China(62201618).
文摘Nano-computed tomography(Nano-CT)is an emerging,high-resolution imaging technique.However,due to their low-light properties,tabletop Nano-CT has to be scanned under long exposure conditions,which the scanning process is time-consuming.For 3D reconstruction data,this paper proposed a lightweight 3D noise reduction method for desktop-level Nano-CT called AAD-ResNet(Axial Attention DeNoise ResNet).The network is framed by theU-net structure.The encoder and decoder are incorporated with the proposed 3D axial attention mechanism and residual dense block.Each layer of the residual dense block can directly access the features of the previous layer,which reduces the redundancy of parameters and improves the efficiency of network training.The 3D axial attention mechanism enhances the correlation between 3D information in the training process and captures the long-distance dependence.It can improve the noise reduction effect and avoid the loss of image structure details.Experimental results show that the network can effectively improve the image quality of a 0.1-s exposure scan to a level close to a 3-s exposure,significantly shortening the sample scanning time.
基金Supported by the Natural Science Basic Research Program in Shaanxi Province(No.2020JM-683).
文摘AIM:To compare the efficacy of pars plana vitrectomy(PPV)combined with internal limiting membrane(ILM)and silicone oil or sterile air tamponade for the treatment of myopic foveoschisis(MF)in highly myopic eyes.METHODS:This retrospective study included 48 myopic eyes of 40 patients with MF and axial lengths(ALs)ranging from 26-32 mm treated between January 2020 and January 2022.All patients were underwent PPV combined with ILM peeling followed by sterile air or silicone oil tamponade and followed up at least 12mo.Based on the features on spectral-domain optical coherence tomography(SD-OCT),the eyes were divided into the MF-only group(Group A,n=15 eyes),MF with central foveal detachment group(Group B,n=20 eyes),and MF with lamellar macular hole group(Group C,n=13 eyes).According to AL,eyes were further divided into three groups:Group D(26.01-28.00 mm,n=12 eyes),Group E(28.01-30.00 mm,n=26 eyes),and Group F(30.01-32.00 mm,n=10 eyes).The best-corrected visual acuity(BCVA),central foveal thickness(CFT),and complications were recorded.RESULTS:The patients included 16 males and 24 females with the mean age of 56±9.82y.The BCVA and CFT improved in all groups after surgery(P<0.01),while there was no significant difference of the CFT in Group A,B,and C postoperatively(P>0.05).The intergroup differences of BCVA and CFT postoperatively were statistically significant in Group D,E,and F.Twenty eyes were injected with sterile air,and 28 eyes were injected with silicone oil for tamponade based on the AL.However,there was no statistically significant difference among Groups D,E,and F in terms of the results of sterile air or silicone oil tamponade.The mean recovery time was 5.9mo for MF patients subjected to silicone oil tamponade and 7.7mo for patients subjected to sterile air tamponade,and the difference was not statistically significant.CONCLUSION:PPV and ILM peeling combined with silicone oil or sterile air tamponade can achieve good results for MF in highly myopic eyes with ALs≤32 mm.