The ultrasonic backscatter(UB)has the advantage of non-invasively obtaining bone density and structure,expected to be an assessment tool for early diagnosis osteoporosis.All former UB measurements were based on exciti...The ultrasonic backscatter(UB)has the advantage of non-invasively obtaining bone density and structure,expected to be an assessment tool for early diagnosis osteoporosis.All former UB measurements were based on exciting a short single-pulse and analyzing the ultrasonic signals backscattered in bone.This study aims to examine amplitude modulation(AM)ultrasonic excitation with UB measurements for predicting bone characteristics.The AM multiple lengths excitation and backscatter measurement(AM-UB)functions were integrated into a portable ultrasonic instrument for bone characterization.The apparent integrated backscatter coefficient in the AM excitation(AIB_(AM))was evaluated on the AM-UB instrumentation.The correlation coefficients of the AIB_(AM) estimating volume fraction(BV/TV),structure model index(SMI),and bone mineral density(BMD)were then analyzed.Significant correlations(|R|=0.82-0.93,p<0.05)were observed between the AIB_(AM),BV/TV,SMI,and BMD.By growing the AM excitation length,the AIB_(AM) values exhibit more stability both in 1.0-MHz and 3.5-MHz measurements.The recommendations in AM-UB measurement were that the avoided length(T1)should be lower than AM excitation length,and the analysis length(T2)should be enough long but not more than AM excitation length.The authors conducted an AM-UB measurement for cancellous bone characterization.Increasing the AM excitation length could substantially enhance AIB_(AM) values stability with varying analyzed signals.The study suggests the portable AM-UB instrument with the integration of real-time analytics software that might provide a potential tool for osteoporosis early screening.展开更多
基金Project supported by the National Natural Science Foundation of China(Grant Nos.12104096,12004079,82127803,11827808,and 61871263)the Shanghai Science and Technology Innovation Plan(Grant Nos.20S31901300 and 19441903400)+1 种基金the Shanghai Rising-Star Program(Grant No.21QC1400100)the China Postdoctoral Science Foundation(Grant No.2021M690709)。
文摘The ultrasonic backscatter(UB)has the advantage of non-invasively obtaining bone density and structure,expected to be an assessment tool for early diagnosis osteoporosis.All former UB measurements were based on exciting a short single-pulse and analyzing the ultrasonic signals backscattered in bone.This study aims to examine amplitude modulation(AM)ultrasonic excitation with UB measurements for predicting bone characteristics.The AM multiple lengths excitation and backscatter measurement(AM-UB)functions were integrated into a portable ultrasonic instrument for bone characterization.The apparent integrated backscatter coefficient in the AM excitation(AIB_(AM))was evaluated on the AM-UB instrumentation.The correlation coefficients of the AIB_(AM) estimating volume fraction(BV/TV),structure model index(SMI),and bone mineral density(BMD)were then analyzed.Significant correlations(|R|=0.82-0.93,p<0.05)were observed between the AIB_(AM),BV/TV,SMI,and BMD.By growing the AM excitation length,the AIB_(AM) values exhibit more stability both in 1.0-MHz and 3.5-MHz measurements.The recommendations in AM-UB measurement were that the avoided length(T1)should be lower than AM excitation length,and the analysis length(T2)should be enough long but not more than AM excitation length.The authors conducted an AM-UB measurement for cancellous bone characterization.Increasing the AM excitation length could substantially enhance AIB_(AM) values stability with varying analyzed signals.The study suggests the portable AM-UB instrument with the integration of real-time analytics software that might provide a potential tool for osteoporosis early screening.