期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Current status of bacteriological parameters and DOC/POC in Xiamen coastal waters 被引量:2
1
作者 Khalid Maskaoui, Tianling Zheng , Huasheng Hong Zhiming Yu, Zhong Hu, Yun Tian, Lizhe Cai School of Life Sciences, Xiamen University, Xiamen 361005, ChinaKey Laboratory of Marine Environmental Science of SED, Xiamen 361005, ChinaKey Laboratory of Marine Ecology & Environmental Science, Chinese Academy of Sciences, Qingdao 266071, China + Corresponding author:86-592-2183217,Fax:86-592-2181510. E-mail: wshwzh @ jingxian. xmu. edu. cn 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2003年第3期443-451,共9页
The surface and bottom waters samples were collected from six locations in Xiamen western sea. The quantified estimation of bacterial production (H-3-thymidine method) and observation of bacterial heterotrophic activi... The surface and bottom waters samples were collected from six locations in Xiamen western sea. The quantified estimation of bacterial production (H-3-thymidine method) and observation of bacterial heterotrophic activity (C-14-glucose method) have been made in order to have a better understanding of the role of marine bacteria and their activities. The results showed that the mean value of bacterial heterotrophic activity was 9 X 10(8) cells/(L. h) in the surface waters and 2.6 X 10(8) cells/(L. h) in the bottom waters. The mean value of bacterial production was 38 X 108 cells/( L. h) in the surface waters and 7.1 X 10(8) cells/(L. h) in the bottom waters. The relationship between bacterial production, heterotrophic activity, PCC and DOC measured during this survey were discussed. The good understanding of the relationship between bacteria activity and total coliform was addressed. 展开更多
关键词 bacteriological parameters POC DOC Xiamen western sea
下载PDF
Physico-chemical,bacteriological and health hazard effect analysis of the water in Taladanda Canal,Paradip area,Odisha,India
2
作者 Rabiranjan Prusty Trinath Biswal 《Journal of Groundwater Science and Engineering》 2020年第4期338-348,共11页
The physico-chemical and bacteriological parameters of the water in Taladanda canal and associated water-borne diseases,from which the dwellers have suffered,were studied,by using statistical method.Overuse and the ad... The physico-chemical and bacteriological parameters of the water in Taladanda canal and associated water-borne diseases,from which the dwellers have suffered,were studied,by using statistical method.Overuse and the addition of the wastes with sources from urbane industrial sectors,as well as the decrease in water level have caused the canal water quality declined drastically and subsequently led to extensive eutrophication and bacterial contamination.According to the water sample analytical results,the water is lightly acidic with the pH value of 4.5~6.7.The measured indexes,such as total dissolved solid(TDS),electrical conductivity(EC),total suspended solid(TSS),Mn,Zn,Al,Fe,Cu,Cr,and Hg etc,mostly have very high concentrations which are higher than permissible limit,indicating that the canal water is completely unsuitable for human consumption.Furthermore,the biological analysis shows that the total coliform(TC)is in the range of 45.9~30.2 in per 100 mL water in April,30.5~25.3/100 mL in July and 52.9~35.4/100 mL in December,respectively.Similarly,fecal coliform(FC)ranges from 12.8 to 10.1,10.5~7.5 and 13.1~6.4 per 100 mL water in the months of April,July and December respectively.As a result,people who use the water have suffered from different water-borne diseases.On the basis of disease data derived from hospital observations in a period of three years,there had been 4284 people affected by different waterborne diseases from 2016 to 2018. 展开更多
关键词 Water quality POLLUTION Physico-chemical assessment bacteriological parameters Health hazard COLIFORM E.COLI
下载PDF
Water Quality Assessment in the Bamoun Plateau, Western-Cameroon: Hydrogeochemical Modelling and Multivariate Statistical Analysis Approach 被引量:1
3
作者 Zakari Mfonka Amidou Kpoumié +7 位作者 Abdou Nasser Ngouh Oumar Farouk Mouncherou Daouda Nsangou Felaniaina Rakotondrabe Alain Fouépé Takounjou Mounira Zammouri Jules Rémy Ndam Ngoupayou Paul-Désiré Ndjigui 《Journal of Water Resource and Protection》 2021年第2期112-138,共27页
This study focuses on the geochemical and bacteriological investigation of surface and ground water in the Bamoun plateau (Western-Cameroon). During the period from September 2013 to August 2014, 71 samples were colle... This study focuses on the geochemical and bacteriological investigation of surface and ground water in the Bamoun plateau (Western-Cameroon). During the period from September 2013 to August 2014, 71 samples were collected from two springs, one borehole, four wells and the Nchi stream for analysis of major elements. In order to obtain the characteristics of the various species of bacteria, 7 samples were selected. The analytical method adopted for this study is the conventional hydrochemical technic and multivariate statistical analysis, coupled with the hydrogeochemical modelling. The results revealed that, water from the zone under study are acidic to basic, very weakly to weakly mineralized. Four types of water were identified: 1) CaMg-HCO<sub>3</sub>;2) CaMg-Cl-SO<sub>4</sub>;3) NaCl-SO<sub>4</sub> and 4) NaK-HCO<sub>3</sub>. The major elements were all listed in the World Health Organization guidelines for drinking water quality, except for nitrates which was found at a concentration > 50 mg /l <span style="white-space:nowrap;">NO<sup>-</sup><sub style="margin-left:-7px;">3</sub> </span>in the borehole F401. As for the hydrobiological aspect, the entire sample contained all the bacteriological species except for spring S301 and well P401. According to the hydrogeochemical modelling, the Gibbs model and multivariate statistical tests, the quality of surface and ground water of the Foumban locality is influenced by two important factors: 1) the natural factors characterized by the water-rock interaction, evapotranspiration/crystallization, 2) the anthropogenic factors such as: uncontrolled discharges of liquid and solid effluents of all kinds and without any prior treatment within the ground and the strong urbanization accompanied by lack of sanitation and insufficient care. 展开更多
关键词 Foumban Surface and Ground Water Water-Rock Interaction bacteriological parameters Hierarchical Clustering Analysis Principal Component Analysis
下载PDF
Adequacy of Water Use Resources for Drinking and Irrigation, Study Case of Sarh City, Capital of Moyen-Chari Province, CHAD
4
作者 Edith Kadjangaba Djimako Bongo Mekila Le Bandoumel 《Open Journal of Modern Hydrology》 CAS 2023年第1期1-21,共21页
Our objective is to evaluate adequacy of water for consumption and irrigation. We collected nineteen water samples from 21 to 26, May 2017. Twenty-two physico-chemical and bacteriological parameters were taken into ac... Our objective is to evaluate adequacy of water for consumption and irrigation. We collected nineteen water samples from 21 to 26, May 2017. Twenty-two physico-chemical and bacteriological parameters were taken into account, electrical conductivity, pH, total hardness, bicarbonate, nitrates, sulfates, chlorides, calcium, sodium, magnesium, potassium, dissolved oxygen and biochemical oxygen demand, chemical oxygen demand, total coliforms, Escherichia Coli, and fecal coliforms. To evaluate water intended for consumption, average values measured parameters were compared to [1] for quality water drinking and we evaluated overall quality of water by means of simplified SEQ-Water grid. Concerning irrigation water, evaluation is based on interpretation of quality parameters of irrigation water that we have calculated;among these parameters we can mention the percentage of sodium, rate of sodium absorption, ratio of magnesium adsorption, residual sodium carbonate. Kelly ratio, Corrosivity ratio and Permeability Index. Results show that surface water is weakly mineralized compared to groundwater and presents a good chemical quality;however, it is slightly altered by presence of organic pollutants. The overall assessment of groundwater quality shows that about 47% of water sampled varies between average quality and very poor quality for consumption. This poor quality is mainly due to presence of nitrates in water, whose content sometimes exceeds the limit authorized by [1]. From a bacteriological point of view, germs of faecal origin such as Total Coliforms, Escherichia Coli and Faecal Coliforms contaminate all groundwater points sampled. They are of poor quality and unfit for human consumption without prior treatment. We also evaluated the quality of water used for irrigation using 6 parameters. The results show that all of our water points are suitable for irrigation, according to the values of CSR and Kelly ratio. The same is true for the permeability index, which shows that all samples fall into class I and II type to indicate their suitability for irrigation purposes. According to [2] all waters are excellent quality for agriculture;and for Richard diagram, 89.5% of waters are generally suitable for irrigation and 10% are generally not suitable for irrigation without prior dilution with low salinity water. 展开更多
关键词 SEQ-Eau Water Quality Consumption IRRIGATION Physico-Chemical and bacteriological parameters
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部