Objective:To explore the efficacy and safety of doxycycline and moxifloxacin in the treatment of tsutsugamushi disease.Methods:There was a total of 80 cases of tsutsugamushi disease that were treated in Jiangsu Sihong...Objective:To explore the efficacy and safety of doxycycline and moxifloxacin in the treatment of tsutsugamushi disease.Methods:There was a total of 80 cases of tsutsugamushi disease that were treated in Jiangsu Sihong Fenjinting Hospital from January 2017 to August 2020.The patients were divided into group A and group B,with 40 cases in each group.The patients in group A were treated with moxifloxacin whereas those in group B were treated with doxycycline.The efficacy and safety of the clinical treatment between the two groups were compared.Results:The effective rate was 72.5% in group A and 95.0% in group B.Compared with group A,group B was better(p<0.05).The time taken for the resolution of clinical symptoms,the detection indexes of liver function,and the incidence of adverse reactions were also compared between the two groups,in which group B was significantly better than group A(p<0.05).Conclusion:In the clinical treatment of tsutsugamushi disease,doxycycline has better therapeutic effect and higher safety compared to moxifloxacin.It can significantly improve the patienfs liver function,reduce the probability of adverse reactions,and accelerate the patienfs physical recovery.展开更多
In order to increase the multiplexing density of the fiber Bragg gratings (FBGs) for a low cost per-sensor, based on the analysis of the spectrum shadow distortion (SSD), a novel successive demultiplexing scheme f...In order to increase the multiplexing density of the fiber Bragg gratings (FBGs) for a low cost per-sensor, based on the analysis of the spectrum shadow distortion (SSD), a novel successive demultiplexing scheme for FBG sensors has been developed. It is based on the optical cade division multiple access (CDMA) balanced demodulation. A high-density multiplexing-demultiplexing system for FBG sensors has been designed, and corresponding simulation carried out has demonstrated that the FBG sensors' reflective signals can still be obtained accurately and respectively, even if FBG sensors' operating bandwidths heavily overlap. The SSD has been greatly mitigated.展开更多
文摘Objective:To explore the efficacy and safety of doxycycline and moxifloxacin in the treatment of tsutsugamushi disease.Methods:There was a total of 80 cases of tsutsugamushi disease that were treated in Jiangsu Sihong Fenjinting Hospital from January 2017 to August 2020.The patients were divided into group A and group B,with 40 cases in each group.The patients in group A were treated with moxifloxacin whereas those in group B were treated with doxycycline.The efficacy and safety of the clinical treatment between the two groups were compared.Results:The effective rate was 72.5% in group A and 95.0% in group B.Compared with group A,group B was better(p<0.05).The time taken for the resolution of clinical symptoms,the detection indexes of liver function,and the incidence of adverse reactions were also compared between the two groups,in which group B was significantly better than group A(p<0.05).Conclusion:In the clinical treatment of tsutsugamushi disease,doxycycline has better therapeutic effect and higher safety compared to moxifloxacin.It can significantly improve the patienfs liver function,reduce the probability of adverse reactions,and accelerate the patienfs physical recovery.
基金supported by the Harbin Science Research Foundation under Grant No.2003AFQXJ004
文摘In order to increase the multiplexing density of the fiber Bragg gratings (FBGs) for a low cost per-sensor, based on the analysis of the spectrum shadow distortion (SSD), a novel successive demultiplexing scheme for FBG sensors has been developed. It is based on the optical cade division multiple access (CDMA) balanced demodulation. A high-density multiplexing-demultiplexing system for FBG sensors has been designed, and corresponding simulation carried out has demonstrated that the FBG sensors' reflective signals can still be obtained accurately and respectively, even if FBG sensors' operating bandwidths heavily overlap. The SSD has been greatly mitigated.