期刊文献+
共找到11篇文章
< 1 >
每页显示 20 50 100
Improving the performance of conventional base isolation systems by an external variable negative stiffness device under near-fault and long-period ground motions 被引量:6
1
作者 Sandhya Nepal Masato Saitoh 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2020年第4期985-1003,共19页
Recent studies have shown that base-isolated objects with long fundamental natural periods are highly influenced by long-period earthquakes. These long-period waves result in large displacements for isolators, possibl... Recent studies have shown that base-isolated objects with long fundamental natural periods are highly influenced by long-period earthquakes. These long-period waves result in large displacements for isolators, possibly leading to exceedance of the allowable displacement limits. Conventional isolation systems, in general, fail to resist such large displacements. This has prompted the need to modify conventional base isolation systems. The current work focuses on the development of an external device, comprising a unit of negative and positive springs, for improving the performance of conventional base isolation systems. This unit accelerates the change in the stiffness of the isolation system where the stiffness of the positive spring varies linearly in terms of the displacement response of the isolated objects. The target objects of the present study are small structures such as computer servers, sensitive instruments and machinery. Numerical studies show that the increase in the damping of the system and the slope of the linear function is effective in reducing the displacement response. An optimal range of damping values and slope, satisfying the stability condition and the allowable limits of both displacement and acceleration responses when the system is subjected to near-fault and long-period ground motions simultaneously, is proposed. 展开更多
关键词 base isolation near-fault earthquakes long-period earthquakes negative stiffness variable stiffness
下载PDF
Mechanical property of U-Shaped 65Mn steel bumpers for seismic base isolation 被引量:2
2
作者 Han Miao Wang Yuandong +1 位作者 Du Hongkai Cui Xiangdong 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2021年第3期791-802,共12页
This study proposes a novel U-shaped 65Mn steel bumper as the displacement restraining device for base-isolated structures with laminated elastomeric rubber bearings.A series of bumpers with different geometric parame... This study proposes a novel U-shaped 65Mn steel bumper as the displacement restraining device for base-isolated structures with laminated elastomeric rubber bearings.A series of bumpers with different geometric parameters were designed and tested under monotonic and cyclic quasi-static loading protocols.The experimental results from a total of 232 specimens were analyzed to develop an analytical model to calculate the backbone curve and the maximum elastic restoring force for U-shaped 65Mn bumpers.Thus,the analytical equations to calculate the elastic,hardening,and unloading stiffness of U-shaped 65Mn bumpers,as well as their maximum elastic restoring force,are validated by using an additional ten groups of bumpers with varying radiuses.These analytical equations can accurately predict the mechanical parameters of U-shaped 65Mn steel bumpers for a design purpose. 展开更多
关键词 U-shaped bumper base isolation EXPERIMENTAL mechanical properties analytical model
下载PDF
Prediction of Damping Capacity Demand in Seismic Base Isolators via Machine Learning
3
作者 Ayla Ocak Umit Isıkdag +3 位作者 Gebrail Bekdas Sinan Melih Nigdeli Sanghun Kim ZongWoo Geem 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第3期2899-2924,共26页
Base isolators used in buildings provide both a good acceleration reduction and structural vibration control structures.The base isolators may lose their damping capacity over time due to environmental or dynamic effe... Base isolators used in buildings provide both a good acceleration reduction and structural vibration control structures.The base isolators may lose their damping capacity over time due to environmental or dynamic effects.This deterioration of them requires the determination of the maintenance and repair needs and is important for the long-termisolator life.In this study,an artificial intelligence prediction model has been developed to determine the damage and maintenance-repair requirements of isolators as a result of environmental effects and dynamic factors over time.With the developed model,the required damping capacity of the isolator structure was estimated and compared with the previously placed isolator capacity,and the decrease in the damping property was tried to be determined.For this purpose,a data set was created by collecting the behavior of structures with single degrees of freedom(SDOF),different stiffness,damping ratio and natural period isolated from the foundation under far fault earthquakes.The data is divided into 5 different damping classes varying between 10%and 50%.Machine learning model was trained in damping classes with the data on the structure’s response to random seismic vibrations.As a result of the isolator behavior under randomly selected earthquakes,the recorded motion and structural acceleration of the structure against any seismic vibration were examined,and the decrease in the damping capacity was estimated on a class basis.The performance loss of the isolators,which are separated according to their damping properties,has been tried to be determined,and the reductions in the amounts to be taken into account have been determined by class.In the developed prediction model,using various supervised machine learning classification algorithms,the classification algorithm providing the highest precision for the model has been decided.When the results are examined,it has been determined that the damping of the isolator structure with the machine learning method is predicted successfully at a level exceeding 96%,and it is an effective method in deciding whether there is a decrease in the damping capacity. 展开更多
关键词 Vibration control base isolation machine learning damping capacity
下载PDF
Seismic Response of Base-Isolated Structures underMulti-component Ground Motion Excitation
4
作者 Jiang Yicheng Tang Jiaxiang School of Civil Engineering , Huazhong University of Science and Technology, Wuhan 430074 《Journal of China University of Geosciences》 SCIE CSCD 2001年第1期90-94,共5页
An analysis of a base-isolated structure for multi-component random ground motion is presented. The mean square respond of the system is Obtained under different parametric variations. The effectiveness of main parame... An analysis of a base-isolated structure for multi-component random ground motion is presented. The mean square respond of the system is Obtained under different parametric variations. The effectiveness of main parameters and the torsional component during an earthquake is quantified with the help of the response ratio and the root mean square response with and without base isolation. It is observed that the base isolation has considerable influence on the response and the effect of the torsional component is not ignored. 展开更多
关键词 multi-component ground motion base isolation random response root mean square response.
下载PDF
Seismic response reduction analysis of large chassis base-isolated structure under long-period ground motions
5
作者 Feiyan Li Linjian Wang Yingxiong Wu 《Earthquake Research Advances》 CSCD 2021年第2期49-56,共8页
Long-period structures(e.g.Isolated structures)tend to produce pseudo-resonance with low frequency compo-nents of long-period ground motions,resulting in the increase in damage.Stiffness mutation occurs due to the set... Long-period structures(e.g.Isolated structures)tend to produce pseudo-resonance with low frequency compo-nents of long-period ground motions,resulting in the increase in damage.Stiffness mutation occurs due to the set-back in the upper body of the large chassis structure.In the parts with stiffness mutation,the torsion effect caused by the tower is far greater than that of the chassis itself.In this study,a total of 273 ground motions are collected and then filtered into four types,including the near-field ordinary,near-field pulse,far-field ordinary,and far-field harmonic.An 8-degree(0.2 g)fortified large chassis base-isolated structure is established.Furthermore,ETABS program software is used to conduct nonlinear time history analysis on the isolation and seismic model under bi-directional earthquake ground motions.The comparison results show that the seismic isolation effect of the base-isolated structure under long-period ground motions is worse than that associated with ordinary ground motions when the seismic response reduction rate of the large base floor significantly decreases compared with that of the tower.When the inter-story displacement angle and the displacement of isolation layer of the chassis exceeds the limit of Code for Seismic Design of Buildings(GB 50011-2010),it is recommended to adopt composite seismic isolation technology or add limit devices.Under the condition of long-period ground motions,the base-isolated structure reduces the lateral-torsional coupling effect of the large chassis structure,while the torsion response of large chassis’top layer increases.Under long-period ground motions with the same acceleration peak,the response of the base-isolated structure increases much more than that of the seismic structure and the consideration of this impact is suggested to be added to the Code. 展开更多
关键词 Long-period ground motions Large chassis structure base isolation Seismic response reduction analysis
下载PDF
Optimal design and effectiveness evaluation for inerter-based devices on mitigating seismic responses of base isolated structures 被引量:2
6
作者 Li Yafeng Li Shouying Chen Zhengqing 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2021年第4期1021-1032,共12页
The optimal design and effectiveness of three control systems,tuned viscous mass damper(TVMD),tuned inerter damper(TID)and tuned mass damper(TMD),on mitigating the seismic responses of base isolated structures,were sy... The optimal design and effectiveness of three control systems,tuned viscous mass damper(TVMD),tuned inerter damper(TID)and tuned mass damper(TMD),on mitigating the seismic responses of base isolated structures,were systematically studied.First,the seismic responses of the base isolated structure with each control system under white noise excitation were obtained.Then,the structural parameter optimizations of the TVMD,TID and TMD were conducted by using three different objectives.The results show that the three control systems were all effective in minimizing the root mean square value of seismic responses,including the base shear of the BIS,the absolute acceleration of structural SDOF,and the relative displacement between the base isolation floor and the foundation.Finally,considering the superstructure as a structural MDOF,a series of time history analyses were performed to investigate the effectiveness and activation sensitivity of the three control systems under far field and near fault seismic excitations.The results show that the effectiveness of TID and TMD with optimized parameters on mitigating the seismic responses of base isolated structures increased as the mass ratio increases,and the effectiveness of TID was always better than TMD with the same mass ratio.The TVMD with a lower mass ratio was more efficient in reducing the seismic response than the TID and TMD.Furthermore,the TVMD,when compared with TMD and TID,had better activation sensitivity and a smaller stroke. 展开更多
关键词 base isolated structure inerter optimal design seismic response vibration control
下载PDF
Rapid report of seismic damage to buildings in the 2022 M 6.8 Luding earthquake,China 被引量:4
7
作者 Zhe Qu Baijie Zhu +1 位作者 Yuteng Cao Haoran Fu 《Earthquake Research Advances》 CSCD 2023年第1期11-30,共20页
The report summarizes the observed damage to a variety of buildings near the epicenter of the M6.8 Luding earthquake in Sichuan Province,China.They include base-isolated buildings,multi-story reinforced concrete(RC)fr... The report summarizes the observed damage to a variety of buildings near the epicenter of the M6.8 Luding earthquake in Sichuan Province,China.They include base-isolated buildings,multi-story reinforced concrete(RC)frame buildings,and masonry buildings.The near-field region is known to be tectonically highly active,and the local intensity level is the highest,that is,0.4g peak ground acceleration(PGA)for the design basis earthquake,in the Chinese zonation of seismic ground motion parameters.The extent of damage ranged from the weak-story collapse that claimed lives to the extensive nonstructural damage that suspended occupancy.The report highlights the first observation of the destruction of rubber bearings and viscous dampers in the isolation layer of Chinese seismically isolated buildings.It also features the rare observation of the brittle shear failure of RC columns in moment-resisting frames in a region of such a high seismic design requirement.Possible reasons that may have attributed to the reported damage are suggested by providing facts observed in the field.However,careful forensic analyses are needed before any conclusive judgment can be made. 展开更多
关键词 base isolation Rubber bearing Viscous damper Reinforced concrete frame Masonry structure Weak-story collapse Near-fault area Terrace riser Nonstructural element
下载PDF
Rapid report of seismic damage to hospitals in the 2023 Turkey earthquake sequences
8
作者 Zhe Qu Feijian Wang +2 位作者 Xiangzhao Chen Xiaoting Wang Zhiguang Zhou 《Earthquake Research Advances》 CSCD 2023年第4期3-26,共24页
The seismic performance of medical systems is crucial for the seismic resilience of communities.The report summarizes the observed damage to twelve hospital buildings in the area affected by the MW 7.8 and MW 7.5 eart... The seismic performance of medical systems is crucial for the seismic resilience of communities.The report summarizes the observed damage to twelve hospital buildings in the area affected by the MW 7.8 and MW 7.5 earthquakes on February 6,2023 in Turkey.They include five base-isolated buildings and seven fixed-base buildings in southcentral Turkey's seven most heavily affected provinces.By relating the post-quake occupancy statuses of the hospitals with the estimated seismic demands during the earthquake doublet,the report offers the following observations:(1)the base-isolated hospital buildings on friction pendulum bearings generally exhibited superior performance of achieving the goal of immediate occupancy and provided better protection for nonstructural elements than fixed-base counterparts did;(2)the fixed-base hospital buildings of reinforced concrete structures constructed after 2001 successfully achieved the goal of collapse prevention even under very high seismic demands;(3)some fixed-base hospitals also remained operational even if they were very close to the fault rupture and were subjected to higher-than-design-level earthquake ground motions. 展开更多
关键词 Medical facility base isolation Friction pendulum bearing Near-fault region Immediate occupancy Nonstructural element Seismic resilience RC frame Collapse prevention
下载PDF
Seismic performance evaluation of VCFPB isolated storage tank using real-time hybrid simulation
9
作者 Hong Yue Tang Zhenyun +1 位作者 Li Zhenbao Du Xiuli 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2022年第2期501-515,共15页
Variable curvature friction pendulum bearings(VCFPB)effectively reduce the dynamic response of storage tanks induced by earthquakes.Shaking table testing is used to assess the seismic performance of VCFPB isolated sto... Variable curvature friction pendulum bearings(VCFPB)effectively reduce the dynamic response of storage tanks induced by earthquakes.Shaking table testing is used to assess the seismic performance of VCFPB isolated storage tanks.However,the vertical pressure and friction coefficient of the scaled VCFPB in the shaking table tests cannot match the equivalent values of these parameters in the prototype.To avoid this drawback,a real-time hybrid simulation(RTHS)test was developed.Using RTHS testing,a 1/8 scaled tank isolated by VCFPB was tested.The experimental results showed that the displacement dynamic magnification factor of VCFPB,peak reduction factors of the acceleration,shear force,and overturning moment at bottom of the tank,were negative exponential functions of the ratio of peak ground acceleration(PGA)and friction coefficient.The peak reduction factors of displacement,acceleration,force and overturning moment,which were obtained from the experimental results,are compared with those calculated by the Housner model.It can be concluded that the Housner model is applicable in estimation of the acceleration,shear force,and overturning moment of liquid storage tank,but not for the sliding displacement of VCFPBs. 展开更多
关键词 liquid storage tank base isolation variable curvature friction pendulum bearing seismic performance real-time hybrid simulation test
下载PDF
Seismic response of selective pallet racks isolated with friction pendulum bearing system
10
作者 Bennet A.Ipe Sajith A.S. 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2022年第4期1069-1088,共20页
The concept of base isolation for storage racks is still a developing subject and has not been addressed in the recently updated seismic codes for storage racks.The friction pendulum bearing system(FPS)generates a nat... The concept of base isolation for storage racks is still a developing subject and has not been addressed in the recently updated seismic codes for storage racks.The friction pendulum bearing system(FPS)generates a natural period independent of the structure's seismic mass.This property makes FPS an ideal choice for isolating rack structures since merchandise may be placed on the racks in several possible arrangements.The results of a comprehensive parametric study aimed at evaluating the seismic performance of a four-shelf,two-bay selective pallet rack isolated with FPS is presented in this paper.The influence of radius of curvature of the FPS,seismic mass,and mass irregularity on the rack's seismic response is examined.The effect of variation of the coefficient of friction due to axial loading is studied by choosing friction values from two distinct friction characterization studies.The coefficient of friction calculated from these studies shows mild and significant variations,respectively,for the whole range of static axial loads expected on the isolator,and from different pallet mass arrangements considered.The optimum radius of curvature and the appropriate range of friction coefficient,for the defined range of static axial loads,to attain a desirable seismic performance are determined. 展开更多
关键词 selective pallet racks base isolation friction pendulum bearing system cross-aisle direction
下载PDF
Simplified performance indices and active control force of vibration isolation systems with elastic base
11
作者 SUN Hongling 《Chinese Journal of Acoustics》 CSCD 2018年第1期69-88,共20页
关键词 In Simplified performance indices and active control force of vibration isolation systems with elastic base
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部