期刊文献+
共找到270,946篇文章
< 1 2 250 >
每页显示 20 50 100
Isolated deep convections over the Tibetan Plateau in the rainy season during 2001–2020 被引量:1
1
作者 Ying Na Chaofan Li Riyu Lu 《Atmospheric and Oceanic Science Letters》 CSCD 2024年第5期16-21,共6页
The Tibetan Plateau(TP)is a prevalent region for convection systems due to its unique thermodynamic forcing.This study investigated isolated deep convections(IDCs),which have a smaller spatial and temporal size than m... The Tibetan Plateau(TP)is a prevalent region for convection systems due to its unique thermodynamic forcing.This study investigated isolated deep convections(IDCs),which have a smaller spatial and temporal size than mesoscale convective systems(MCSs),over the TP in the rainy season(June-September)during 2001–2020.The authors used satellite precipitation and brightness temperature observations from the Global Precipitation Measurement mission.Results show that IDCs mainly concentrate over the southern TP.The IDC number per rainy season decreases from around 140 over the southern TP to around 10 over the northern TP,with an average 54.2.The initiation time of IDCs exhibits an obvious diurnal cycle,with the peak at 1400–1500 LST and the valley at 0900–1000 LST.Most IDCs last less than five hours and more than half appear for only one hour.IDCs generally have a cold cloud area of 7422.9 km^(2),containing a precipitation area of approximately 65%.The larger the IDC,the larger the fraction of intense precipitation it contains.IDCs contribute approximately 20%–30%to total precipitation and approximately 30%–40%to extreme precipitation over the TP,with a larger percentage in July and August than in June and September.In terms of spatial distribution,IDCs contribute more to both total precipitation and extreme precipitation over the TP compared to the surrounding plain regions.IDCs over the TP account for a larger fraction than MCSs,indicating the important role of IDCs over the region. 展开更多
关键词 isolated deep convection Tibetan plateau Climatological characteristics Precipitation contribution Extreme precipitation
下载PDF
Seismic response of a mid-story isolated structure considering SSI in mountainous areas under long-period earthquakes 被引量:1
2
作者 Wan Feng Qin Shengwu +7 位作者 Liu Dewen Zhao Tiange Zheng Yanping Shan Hang Li Zhiang Peng Fusong Xu Jingran Lei Min 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2024年第1期151-161,共11页
At present,there is not much research on mid-story isolated structures in mountainous areas.In this study,a model of a mid-story isolated structure considering soil-structure interaction(SSI)in mountainous areas is es... At present,there is not much research on mid-story isolated structures in mountainous areas.In this study,a model of a mid-story isolated structure considering soil-structure interaction(SSI)in mountainous areas is established along with a model that does not consider SSI.Eight long-period earthquake waves and two ordinary earthquake waves are selected as inputs for the dynamic time history analysis of the structure.The results show that the seismic response of a mid-story isolated structure considering SSI in mountainous areas can be amplified when compared with a structure that does not consider SSI.The structure response under long-period earthquakes is larger than that of ordinary earthquakes.The structure response under far-field harmonic-like earthquakes is larger than that of near-fault pulse-type earthquakes.The structure response under near-fault pulse-type earthquakes is larger than that of far-field non-harmonic earthquakes.When subjected to long-period earthquakes,the displacement of the isolated bearings exceeded the limit value,which led to instability and overturning of the structure.The structure with dampers in the isolated story could adequately control the nonlinear response of the structure,effectively reduce the displacement of the isolated bearings,and provide a convenient,efficient and economic method not only for new construction but also to retrofit existing structures. 展开更多
关键词 SSI in mountainous areas long-period earthquakes mid-story isolated structure structural dynamic analysis
下载PDF
Prediction of Damping Capacity Demand in Seismic Base Isolators via Machine Learning
3
作者 Ayla Ocak Umit Isıkdag +3 位作者 Gebrail Bekdas Sinan Melih Nigdeli Sanghun Kim ZongWoo Geem 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第3期2899-2924,共26页
Base isolators used in buildings provide both a good acceleration reduction and structural vibration control structures.The base isolators may lose their damping capacity over time due to environmental or dynamic effe... Base isolators used in buildings provide both a good acceleration reduction and structural vibration control structures.The base isolators may lose their damping capacity over time due to environmental or dynamic effects.This deterioration of them requires the determination of the maintenance and repair needs and is important for the long-termisolator life.In this study,an artificial intelligence prediction model has been developed to determine the damage and maintenance-repair requirements of isolators as a result of environmental effects and dynamic factors over time.With the developed model,the required damping capacity of the isolator structure was estimated and compared with the previously placed isolator capacity,and the decrease in the damping property was tried to be determined.For this purpose,a data set was created by collecting the behavior of structures with single degrees of freedom(SDOF),different stiffness,damping ratio and natural period isolated from the foundation under far fault earthquakes.The data is divided into 5 different damping classes varying between 10%and 50%.Machine learning model was trained in damping classes with the data on the structure’s response to random seismic vibrations.As a result of the isolator behavior under randomly selected earthquakes,the recorded motion and structural acceleration of the structure against any seismic vibration were examined,and the decrease in the damping capacity was estimated on a class basis.The performance loss of the isolators,which are separated according to their damping properties,has been tried to be determined,and the reductions in the amounts to be taken into account have been determined by class.In the developed prediction model,using various supervised machine learning classification algorithms,the classification algorithm providing the highest precision for the model has been decided.When the results are examined,it has been determined that the damping of the isolator structure with the machine learning method is predicted successfully at a level exceeding 96%,and it is an effective method in deciding whether there is a decrease in the damping capacity. 展开更多
关键词 Vibration control base isolation machine learning damping capacity
下载PDF
Sedimentary build-ups of pre-salt isolated carbonate platforms and formation of deep-water giant oil fields in Santos Basin,Brazil
4
作者 DOU Lirong WEN Zhixin +7 位作者 WANG Zhaoming HE Zhengjun SONG Chengpeng CHEN Ruiyin YANG Xiaofa LIU Xiaobing LIU Zuodong CHEN Yanyan 《Petroleum Exploration and Development》 SCIE 2024年第4期949-962,共14页
In response to the problems of unclear distribution of deep-water pre-salt carbonate reservoirs and formation conditions of large oil fields in the Santos passive continental margin basin,based on comprehensive utiliz... In response to the problems of unclear distribution of deep-water pre-salt carbonate reservoirs and formation conditions of large oil fields in the Santos passive continental margin basin,based on comprehensive utilization of geological,seismic,and core data,and reconstruction of Early Cretaceous prototype basin and lithofacies paleogeography,it is proposed for the first time that the construction of pre-salt carbonate build-ups was controlled by two types of isolated platforms:inter-depression fault-uplift and intra-depression fault-high.The inter-depression fault-uplift isolated platforms are distributed on the present-day pre-salt uplifted zones between depressions,and are built on half-and fault-horst blocks that were inherited and developed in the early intra-continental and inter-continental rift stages.The late intra-continental rift coquinas of the ITP Formation and the early inter-continental rift microbial limestones of the BVE Formation are continuously constructed;intra-depression fault-high isolated platforms are distributed in the current pre-salt depression zones,built on the uplifted zones formed by volcanic rock build-ups in the early prototype stage of intra-continental rifts,and only the BVE microbial limestones are developed.Both types of limestones formed into mound-shoal bodies,that have the characteristics of large reservoir thickness and good physical properties.Based on the dissection of large pre-salt oil fields discovered in the Santos Basin,it has been found that both types of platforms could form large-scale combined structural-stratigraphic traps,surrounded by high-quality lacustrine and lagoon source rocks at the periphery,and efficiently sealed by thick high-quality evaporite rocks above,forming the optimal combination of source,reservoir and cap in the form of“lower generation,middle storage,and upper cap”,with a high degree of oil and gas enrichment.It has been found that the large oil fields are all bottom water massive oil fields with a unified pressure system,and they are all filled to the spill-point.The future exploration is recommended to focus on the inter-depression fault-uplift isolated platforms in the western uplift zone and the southern section of eastern uplift zones,as well as intra-depression fault-high isolated platforms in the central depression zone.The result not only provides an important basis for the advanced selection of potential play fairways,bidding of new blocks,and deployment of awarded exploration blocks in the Santos Basin,but also provides a reference for the global selection of deep-water exploration blocks in passive continental margin basins. 展开更多
关键词 Santos Basin passive continental marginal basin deep water inter-depression fault-uplift isolated carbonate platform intra-depression fault-high carbonate isolated platform giant oil fields
下载PDF
A low-frequency and broadband wave-insulating vibration isolator based on plate-shaped metastructures
5
作者 Wei WEI Feng GUAN Xin FANG 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI CSCD 2024年第7期1171-1188,共18页
A metamaterial vibration isolator,termed as wave-insulating isolator,is proposed,which preserves enough load-bearing capability and offers ultra-low and broad bandgaps for greatly enhanced wave insulation.It consists ... A metamaterial vibration isolator,termed as wave-insulating isolator,is proposed,which preserves enough load-bearing capability and offers ultra-low and broad bandgaps for greatly enhanced wave insulation.It consists of plate-shaped metacells,whose symmetric and antisymmetric local resonant modes offer several low and broad mode bandgaps although the complete bandgap remains high and narrow.The bandgap mechanisms,vibration isolation properties,effects of key parameters,and robustness to complex conditions are clarified.As experimentally demonstrated,the wave-insulating isolator can improve the vibration insulation in the ranges of[50 Hz,180 Hz]and[260 Hz,400 Hz]by 15 dB and 25 dB,respectively,in contrast to the conventional isolator with the same first resonant frequency. 展开更多
关键词 metamaterial and metastructure vibration isolation bandgap wave insulation PLATE
下载PDF
A vibration isolator with a controllable quasi-zero stiffness region based on nonlinear force design
6
作者 Xinyu LIAN Bing LIU +1 位作者 Huaxia DENG Xinglong GONG 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI CSCD 2024年第8期1279-1294,共16页
To achieve stability optimization in low-frequency vibration control for precision instruments,this paper presents a quasi-zero stiffness(QZS)vibration isolator with adjustable nonlinear stiffness.Additionally,the str... To achieve stability optimization in low-frequency vibration control for precision instruments,this paper presents a quasi-zero stiffness(QZS)vibration isolator with adjustable nonlinear stiffness.Additionally,the stress-magnetism coupling model is established through meticulous theoretical derivation.The controllable QZS interval is constructed via parameter design and magnetic control,effectively segregating the high static stiffness bearing section from the QZS vibration isolation section.Furthermore,a displacement control scheme utilizing a magnetic force is proposed to regulate entry into the QZS working range for the vibration isolation platform.Experimental results demonstrate that the operation within this QZS region reduces the peak-to-peak acceleration signal by approximately 66.7%compared with the operation outside this region,thereby significantly improving the low frequency performance of the QZS vibration isolator. 展开更多
关键词 low frequency NONLINEAR vibration isolator quasi-zero stiffness(QzS)
下载PDF
Traumatic isolated bilateral gluteus minimus injuries misdiagnosed as lumbar radiculopathy:A case report
7
作者 Hong-Man Cho Haeryong Heo Myung-Cheol Jung 《World Journal of Clinical Cases》 SCIE 2024年第34期6715-6720,共6页
BACKGROUND The tear of the gluteus medius and minimus tendons can cause chronic buttock pain,especially in middle-aged individuals;these tears occur mostly in association with degenerative changes in the muscles and t... BACKGROUND The tear of the gluteus medius and minimus tendons can cause chronic buttock pain,especially in middle-aged individuals;these tears occur mostly in association with degenerative changes in the muscles and tendons.Chronic injuries are more common than acute injuries,and concurrent injuries to the gluteus medius and minimus tendons without chronic pain are rare,especially isolated injuries to both sides of the gluteus minimus;such a case has not yet been reported.CASE SUMMARY The authors present a case of bilateral acute traumatic injuries to the gluteus minimus during buttock strengthening exercises in a 75-year-old male patient.The patient completely returned to his pre-injury lifestyle after 8 weeks of injury,with no limitations,but the diagnosis was initially delayed due to misdiagnosis as lumbar radiculopathy,resulting in unnecessary socio-economic burden on the patient.CONCLUSION When treating patients who complain of hip pain,it is important to consider various causes to make a correct diagnosis. 展开更多
关键词 Gluteus minimus Hip joints isolated tear SPRAINS STRAINS Case report
下载PDF
Large isolated fibrous tumors in the upper esophagus: A case report
8
作者 Jia-Jia Yu Huan-Shuang Pei Yu Meng 《World Journal of Gastrointestinal Oncology》 SCIE 2024年第2期543-549,共7页
BACKGROUND Solitary fibrous tumors(SFT)are rare spindle cell tumors that are usually benign.A total of 10 cases of SFTs in the upper esophagus have ever been reported.Here,we report the anesthetic management of a pati... BACKGROUND Solitary fibrous tumors(SFT)are rare spindle cell tumors that are usually benign.A total of 10 cases of SFTs in the upper esophagus have ever been reported.Here,we report the anesthetic management of a patient with a large isolated fibrous tumor of the upper esophagus compressing the tracheal membrane.We also provide a literature review of the current research.CASE SUMMARY We report the case of a 49 year old male with“cough aggravation and wheezing after exercise”,who underwent esophagectomy for a large isolated fibrous tumor compressing the tracheal membrane in the upper esophagus.We advise the use of a single-lumen tube with a blocker in patients with difficult airways to reduce the incidence of airway injury and fibrinoscopy at all stages of the perioperative period to guide airway management.This case study is the first report of the anesthetic management of a large,isolated fibrous tumor compressing the tracheal membrane in the upper esophagus.CONCLUSION This rare case emphasizes the importance of perioperative management of anesthesia in patients with large isolated fibrous tumors of the upper esophagus that compress the tracheal membrane.The use of blocker reduce the incidence of airway injury and fibrinoscopy at the perioperative period to guide airway mana-gement. 展开更多
关键词 Upper esophagus isolated fibrous tumor Tracheal membrane Peak airway pressure Case report
下载PDF
Study on the Influence of Aspect Ratio on the Seismic Response and Overturning Resistance of a New Staggered Story Isolated Structure
9
作者 Tiange Zhao Dewen Liu 《World Journal of Engineering and Technology》 2024年第3期617-634,共18页
The aspect ratio of the structure has a significant impact on the overall stability of the ultra high-rise building. A large aspect ratio of the structure increases the risk of overturning and reduces the lateral stif... The aspect ratio of the structure has a significant impact on the overall stability of the ultra high-rise building. A large aspect ratio of the structure increases the risk of overturning and reduces the lateral stiffness of the structure, leading to significant tensile and compressive stresses in the isolated bearings. To study the effect of aspect ratio on the seismic response and overturning resistance of a new staggered story isolated structure, three models with different aspect ratios were established. Nonlinear time-history analysis of the three models was conducted using ETABS finite element software. The results indicate that the overturning moment and overturning resistance moment of the superstructure in the new staggered story isolated structure increase with an increasing aspect ratio. However, the increase in the overturning moment of the superstructure is much greater than the increase in the overturning resistance moment, resulting in a decrease in the overturning resistance ratio of the superstructure with an increasing aspect ratio. The overturning moment and overturning resistance moment of the substructure in the new staggered story isolated structure decrease with an increasing aspect ratio. However, the decrease in the overturning moment of the substructure is greater than the decrease in the overturning resistance moment, leading to an increase in the overturning resistance ratio of the substructure with an increasing aspect ratio. The decrease in the overturning resistance ratio of the superstructure in the new staggered story isolated structure is much greater than the increase in the overturning resistance ratio of the substructure. Therefore, as the aspect ratio of the overall structure increases, the overturning resistance ratio of the superstructure and the entire structure decreases. 展开更多
关键词 Aspect Ratio A New Staggered Story isolated Structure Seismic Response Overturning Resistance Ratio isolated Bearing
下载PDF
Endoscopic ultrasound-guided treatment of isolated gastric varices entwined with arteries:A case report
10
作者 Hong-Ying Zhang Chen-Cong He Ding-Fu Zhong 《World Journal of Gastrointestinal Endoscopy》 2024年第8期489-493,共5页
BACKGROUND Interventional endoscopic ultrasound is clinically used for the treatment of isolated gastric varices(IGVs)owing to its precise visualization.CASE SUMMARY A 39-year-old man was diagnosed with a large IGV du... BACKGROUND Interventional endoscopic ultrasound is clinically used for the treatment of isolated gastric varices(IGVs)owing to its precise visualization.CASE SUMMARY A 39-year-old man was diagnosed with a large IGV during a routine physical examination.Endoscopic ultrasonography showed gastric varices entwined with an artery,which greatly increased the difficulty of treatment.We successfully treated the patient with endoscopic ultrasonography-guided coil embolization combined with cyanoacrylate injection.CONCLUSION Endoscopic ultrasonography-guided coil embolization combined with cyanoacrylate injection was safe and effective for the treatment of an IGV entwined with an artery. 展开更多
关键词 Interventional endoscopic ultrasound isolated gastric varices CYANOACRYLATE Coil embolization Case report
下载PDF
Seismic Response of Adjacent Structure to Inter-Story Isolated Structure
11
作者 Bingxing Ma Dewen Liu +3 位作者 Zhuoxin Yang Jiayu Zhou Yong Ding Tao Ban 《World Journal of Engineering and Technology》 2024年第1期92-102,共11页
Currently, land resources are becoming more and more constrained and structures are getting closer to each other. To investigate the seismic response of inter-story isolated structure to adjacent structure, models con... Currently, land resources are becoming more and more constrained and structures are getting closer to each other. To investigate the seismic response of inter-story isolated structure to adjacent structure, models considering no soil-structure interaction (SSI), considering soil-structure interaction (SSI), and considering structure-soil-structure interaction (SSSI) were established. Nonlinear seismic response comparative analysis was conducted by varying the spacing between adjacent structure and inter-story isolated structure, as well as the weight of adjacent structure, under different earthquake inputs, in order to obtain the structural response characteristics. The results indicate that the inter-story drift and inter-story shear of the inter-story isolated structure without considering SSI are smaller than those considering SSI and SSSI. The inter-story drift and inter-story shear of the inter-story isolated structure considering SSSI are further affected compared to that of the inter-story isolated structure considering only SSI. As the spacing between adjacent structure and inter-story isolated structure increases, the influence of adjacent structure on inter-story isolated structure decreases. The variation in the spacing between the two structures has a negligible effect on the isolation layer of the inter-story isolated structure. With the increase in the weight of adjacent structure, the influence of adjacent structure on inter-story isolated structure becomes more significant. The increasing weight of adjacent structure has an increasing effect on the Isolation layer of the inter-story isolated structure. 展开更多
关键词 Soil-Structure Interaction (SSI) Structure-Soil-Structure Interaction (SSSI) In-ter-Story isolation Adjacent Structure
下载PDF
Progressive Collapse Resistance of a New Staggered Story Isolated System
12
作者 Yutong Yang Yuancheng Mi +4 位作者 Hong Li Zhongfa Guo Dewen Liu Weiwei Sun Min Lei 《Open Journal of Applied Sciences》 2024年第3期643-659,共17页
A new staggered isolated system developed from the mid-story isolated system is the new staggered story isolated system. There are not many studies on this structure currently. In this study, an 18-story new staggered... A new staggered isolated system developed from the mid-story isolated system is the new staggered story isolated system. There are not many studies on this structure currently. In this study, an 18-story new staggered story isolated system model is established using SAP2000. The dynamic nonlinear dynamic alternate method is used to analyze the structure against progressive collapse. Results show that the structure has good resistance to progressive collapse, and there is no progressive collapse under each working condition. The progressive collapse does not occur for the case of removing only one vertical structural member of the new staggered of isolated system. The side column has big influence on this isolated structures’ progressive collapse;the removal of vertical structural member of the isolation layer has less impact on the structure than the removal of the bottom vertical structural member. After the removing of the member, the internal force of the structure will be redistributed, and the axial force of the adjacent columns will change obviously, showing a trend of “near large and far small”. 展开更多
关键词 The New Staggered Story isolated System Alternative Load Path Method Collapse Resistance
下载PDF
Influence of Vertical Irregularity on the Seismic Behavior of Base Isolated RC Structures with Lead Rubber Bearings under Pulse-Like Earthquakes
13
作者 Ali Mahamied Amjad AYasin +2 位作者 Yazan Alzubi Jamal Al Adwan Issa Mahamied 《Structural Durability & Health Monitoring》 EI 2023年第6期501-519,共19页
Nowadays,an extensive number of studies related to the performance of base isolation systems implemented in regular reinforced concrete structures subjected to various types of earthquakes can be found in the literatu... Nowadays,an extensive number of studies related to the performance of base isolation systems implemented in regular reinforced concrete structures subjected to various types of earthquakes can be found in the literature.On the other hand,investigations regarding the irregular base-isolated reinforced concrete structures’performance when subjected to pulse-like earthquakes are very scarce.The severity of pulse-like earthquakes emerges from their ability to destabilize the base-isolated structure by remarkably increasing the displacement demands.Thus,this study is intended to investigate the effects of pulse-like earthquake characteristics on the behavior of low-rise irregular base-isolated reinforced concrete structures.Within the study scope,investigations related to the impact of the pulse-like earthquake characteristics,irregularity type,and isolator properties will be conducted.To do so,different values of damping ratios of the base isolation system were selected to investigate the efficiency of the lead rubber-bearing isolator.In general,the outcomes of the study have shown the significance of vertical irregularity on the performance of base-isolated structures and the considerable effect of pulse-like ground motions on the buildings’behavior. 展开更多
关键词 Reinforced concrete low-rise structure vertical irregularity the influence of pulse-like earthquake characteristics lead rubber bearing isolators nonlinear response history analysis
下载PDF
Baseline Isolated Printed Text Image Database for Pashto Script Recognition
14
作者 Arfa Siddiqu Abdul Basit +3 位作者 Waheed Noor Muhammad Asfandyar Khan M.Saeed H.Kakar Azam Khan 《Intelligent Automation & Soft Computing》 SCIE 2023年第7期875-885,共11页
The optical character recognition for the right to left and cursive languages such as Arabic is challenging and received little attention from researchers in the past compared to the other Latin languages.Moreover,the... The optical character recognition for the right to left and cursive languages such as Arabic is challenging and received little attention from researchers in the past compared to the other Latin languages.Moreover,the absence of a standard publicly available dataset for several low-resource lan-guages,including the Pashto language remained a hurdle in the advancement of language processing.Realizing that,a clean dataset is the fundamental and core requirement of character recognition,this research begins with dataset generation and aims at a system capable of complete language understanding.Keeping in view the complete and full autonomous recognition of the cursive Pashto script.The first achievement of this research is a clean and standard dataset for the isolated characters of the Pashto script.In this paper,a database of isolated Pashto characters for forty four alphabets using various font styles has been introduced.In order to overcome the font style shortage,the graphical software Inkscape has been used to generate sufficient image data samples for each character.The dataset has been pre-processed and reduced in dimensions to 32×32 pixels,and further converted into the binary format with a black background and white text so that it resembles the Modified National Institute of Standards and Technology(MNIST)database.The benchmark database is publicly available for further research on the standard GitHub and Kaggle database servers both in pixel and Comma Separated Values(CSV)formats. 展开更多
关键词 Text-image database optical character recognition(OCR) pashto isolated characters visual recognition autonomous language understanding deep learning convolutional neural network(CNN)
下载PDF
Seismic response evaluation of base-isolated reinforced concrete buildings under bidirectional excitation 被引量:8
15
作者 Satish Bhagat Anil C Wijeyewickrema 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2017年第2期365-382,共18页
This paper reports on an investigation of the seismic response of base-isolated reinforced concrete buildings, which considers various isolation system parameters under bidirectional near-fault and far-fault motions. ... This paper reports on an investigation of the seismic response of base-isolated reinforced concrete buildings, which considers various isolation system parameters under bidirectional near-fault and far-fault motions. Three-dimensional models of 4-, 8-, and 12-story base-isolated buildings with nonlinear effects in the isolation system and the superstructure are investigated, and nonlinear response history analysis is carried out. The bounding values of isolation system properties that incorporate the aging effect of isolators are also taken into account, as is the current state of practice in the design and analysis of base-isolated buildings. The response indicators of the buildings are studied for near-fault and far-fault motions weight-scaled to represent the design earthquake (DE) level and the risk-targeted maximum considered earthquake (MCER) level. Results of the nonlinear response history analyses indicate no structural damage under DE-level motions for near-fault and far-fault motions and for MCER-level far-fault motions, whereas minor structural damage is observed under MCER- level near-fault motions. Results of the base-isolated buildings are compared with their fixed-base counterparts. Significant reduction of the superstructure response of the 12-story base-isolated building compared to the fixed-base condition indicates that base isolation can be effectively used in taller buildings to enhance performance. Additionally, the applicability of a rigid superstructure to predict the isolator displacement demand is also investigated. It is found that the isolator displacements can be estimated accurately using a rigid body model for the superstructure for the buildings considered. 展开更多
关键词 Keywords: base isolation bidirectional excitation bounding analysis far-fault ground motion near-fault groundmotion nonlinear analysis
下载PDF
Nonlinear dynamic analysis of multi-base seismically isolated structures with uplift potentialⅡ:verification examples 被引量:5
16
作者 Panayiotis C.Roussis Panos C.Tsopelas Michael C.Constantinou 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2010年第1期83-91,共9页
The work presented in this paper serves as numerical verification of the analytical model developed in the companion paper for nonlinear dynamic analysis of multi-base seismically isolated structures. To this end, two... The work presented in this paper serves as numerical verification of the analytical model developed in the companion paper for nonlinear dynamic analysis of multi-base seismically isolated structures. To this end, two numerical examples have been analyzed using the computational algorithm incorporated into program 3D-BASIS-ME-MB, developed on the basis of the newly-formulated analytical model. The first example concerns a seven-story model structure that was tested on the earthquake simulator at the University at Buflhlo and was also used as a verification example for program SAP2000. The second example concerns a two-tower, multi-story structure with a split-level seismic-isolation system. For purposes of verification, key results produced by 3D-BASIS-ME-MB are compared to experimental results, or results obtained from other structural/finite element programs. In both examples, the analyzed structure is excited under conditions of bearing uplift, thus yielding a case of much interest in verifying the capabilities of the developed analysis tool. 展开更多
关键词 seismic isolation nonlinear dynamic analysis UPLIFT VERIFICATION multiple superstructures/bases
下载PDF
Performance-based semi-active control algorithm for protecting base isolated buildings from near-fault earthquakes 被引量:3
17
作者 Behnam Mehrparvar Taramarz Khoshnoudian 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2012年第1期43-55,共13页
Base isolated structures have been found to be at risk in near-fault regions as a result of long period pulses that may exist in near-source ground motions. Various control strategies, including passive, active and se... Base isolated structures have been found to be at risk in near-fault regions as a result of long period pulses that may exist in near-source ground motions. Various control strategies, including passive, active and semi-active control systems, have been investigated to overcome this problem. This study focuses on the development of a semi-active control algorithm based on several performance levels anticipated from an isolated building during different levels of ground shaking corresponding to various earthquake hazard levels. The proposed performance-based algorithm is based on a modified version of the well-known semi-active skyhook control algorithm. The proposed control algorithm changes the control gain depending on the level of shaking imposed on the structure. The proposed control system has been evaluated using a series of analyses performed on a base isolated benchmark building subjected to seven pairs of scaled ground motion records. Simulation results show that the newly proposed algorithm is effective in improving the structural and nonstructural performance of the building for selected earthquakes. 展开更多
关键词 structural control active control semi-active control base isolation
下载PDF
Nonlinear dynamic analysis of multi-base seismically isolated structures with uplift potential Ⅰ:formulation 被引量:2
18
作者 Panos C.Tsopelas Panayiotis C.Roussis Michael C.Constantinou 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2009年第3期421-431,共11页
The complexity of modem seismically isolated structures requires the analysis of the structural, system and the isolation system in its entirety and the ability to capture potential discontinuous phenomena such as iso... The complexity of modem seismically isolated structures requires the analysis of the structural, system and the isolation system in its entirety and the ability to capture potential discontinuous phenomena such as isolator uplift and their effects on the superstructures and the isolation hardware. In this paper, an analytical model is developed and a computational algorithm is formulated to analyze complex seismically isolated superstructures even when undergoing highly-nonlinear phenomena such as uplift. The computational model has the capability of modeling various types of isolation devices with strong nonlinearities, analyzing multiple superstructures (up to five separate superstructures) on multiple bases (up to five bases), and capturing the effects of lateral loads on bearing axial forces, including bearing uplift. The model developed herein has been utilized to form the software platform 3D-BASIS-ME-MB, which provides the practicing engineering community with a versatile tool for analysis and design of complex structures with modem isolation systems. 展开更多
关键词 friction-pendulum isolator seismic isolation nonlinear dynamic analysis UPLIFT multiple superstructures multiple bases
下载PDF
Optimal PD/PID control of smart base isolated buildings equipped with piezoelectric friction dampers 被引量:17
19
作者 Sadegh Etedali Mohammad Reza Sohrabi Saeed Tavakoli 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2013年第1期39-54,共16页
Long-period pulses in near-field earthquakes lead to large displacements in the base of isolated structures.To dissipate energy in isolated structures using semi-active control,piezoelectric friction dampers(PFD) ca... Long-period pulses in near-field earthquakes lead to large displacements in the base of isolated structures.To dissipate energy in isolated structures using semi-active control,piezoelectric friction dampers(PFD) can be employed.The performance of a PFD is highly dependent on the strategy applied to adjust its contact force.In this paper,the seismic control of a benchmark isolated building equipped with PFD using PD/PID controllers is developed.Using genetic algorithms,these controllers are optimized to create a balance between the performance and robustness of the closed-loop structural system.One advantage of this technique is that the controller forces can easily be estimated.In addition,the structure is equipped with only a single sensor at the base floor to measure the base displacement.Considering seven pairs of earthquakes and nine performance indices,the performance of the closed-loop system is evaluated.Then,the results are compared with those given by two well-known methods:the maximum possive operation of piezoelectric friction dampers and LQG controllers.The simulation results show that the proposed controllers perform better than the others in terms of simultaneous reduction of floor acceleration and maximum displacement of the isolator.Moreover,they are able to reduce the displacement of the isolator systems for different earthquakes without losing the advantages of isolation. 展开更多
关键词 seismic isolation semi-active control piezoelectric friction dampers PD/PID controllers
下载PDF
GA-iForest: An Efficient Isolated Forest Framework Based on Genetic Algorithm for Numerical Data Outlier Detection 被引量:4
20
作者 LI Kexin LI Jing +3 位作者 LIU Shuji LI Zhao BO Jue LIU Biqi 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI CSCD 2019年第6期1026-1038,共13页
With the development of data age,data quality has become one of the problems that people pay much attention to.As a field of data mining,outlier detection is related to the quality of data.The isolated forest algorith... With the development of data age,data quality has become one of the problems that people pay much attention to.As a field of data mining,outlier detection is related to the quality of data.The isolated forest algorithm is one of the more prominent numerical data outlier detection algorithms in recent years.In the process of constructing the isolation tree by the isolated forest algorithm,as the isolation tree is continuously generated,the difference of isolation trees will gradually decrease or even no difference,which will result in the waste of memory and reduced efficiency of outlier detection.And in the constructed isolation trees,some isolation trees cannot detect outlier.In this paper,an improved iForest-based method GA-iForest is proposed.This method optimizes the isolated forest by selecting some better isolation trees according to the detection accuracy and the difference of isolation trees,thereby reducing some duplicate,similar and poor detection isolation trees and improving the accuracy and stability of outlier detection.In the experiment,Ubuntu system and Spark platform are used to build the experiment environment.The outlier datasets provided by ODDS are used as test.According to indicators such as the accuracy,recall rate,ROC curves,AUC and execution time,the performance of the proposed method is evaluated.Experimental results show that the proposed method can not only improve the accuracy and stability of outlier detection,but also reduce the number of isolation trees by 20%-40%compared with the original iForest method. 展开更多
关键词 outlier detection isolation tree isolated forest genetic algorithm feature selection
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部