Measurement and Analysis of Movement of BPM Vacuum Chamber for HLS
1
作者 曹涌 孙葆根 +5 位作者 何多慧 李建伟 李川 宣科 王季刚 卢平 《Chinese Physics C》 SCIE CAS CSCD 北大核心 2008年第z1期127-129,共3页
The beam horizontal orbit at Hefei Light Source(HLS)was drifting all along while the storage ring was operating.To study this phenomenon,the displacement and the temperature variation of the BPM chamber were measured.... The beam horizontal orbit at Hefei Light Source(HLS)was drifting all along while the storage ring was operating.To study this phenomenon,the displacement and the temperature variation of the BPM chamber were measured.By analyzing the measurement results,the main reason that explained the drifting phenomenon was found. The vacuum chamber following the dipole magnets was heated by the synchrotron light,which caused the increasing of the chamber surface temperature.The variation of the chamber temperature was the main reason why the BPM chamber held the horizontal displacement.To suppress the orbit drifting,a compensation method of BPM movement was proposed and its experimental results were given. 展开更多
关键词 beam horizontal orbit thermal effect of SR raster gauge movement of BPM vacuum chamber correction on-line