Numerical and experimental study on coherent beam combining of fibre amplifiers using simulated annealing algorithm
1
作者 周朴 马阎星 +3 位作者 王小林 马浩统 许晓军 刘泽金 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第2期280-289,共10页
We present the numerical and experimental study on the coherent beam combining of fibre amplifiers by means of simulated annealing (SA) algorithm. The feasibility is validated by the Monte Carlo simulation of correc... We present the numerical and experimental study on the coherent beam combining of fibre amplifiers by means of simulated annealing (SA) algorithm. The feasibility is validated by the Monte Carlo simulation of correcting static phase distortion using SA algorithm. The performance of SA algorithm under time-varying phase noise is numerically studied by dynamic simulation. It is revealed that the influence of phase noise on the performance of SA algorithm gets stronger with an increase in amplitude or frequency of phase noise; and the laser array that contains more lasers will be more affected from phase noise. The performance of SA algorithm for coherent beam combining is also compared with a widely used stochastic optimization algorithm, i.e., the stochastic parallel gradient descent (SPGD) algorithm. In a proof-of-concept experiment we demonstrate the coherent beam combining of two 1083~nm fibre amplifiers with a total output power of 12~W and 93% combining efficiency. The contrast of the far-field coherently combined beam profiles is calculated to be as high as 95%. 展开更多
关键词 coherent beam combining simulated annealing laser array stochastic parallel gradient descent
下载PDF
Geometric calibration for a SPECT system dedicated to breast imaging 被引量:1
2
作者 武丽伟 曹学香 +7 位作者 王璐 黄先超 柴培 贠明凯 张玉包 张龙 单保慈 魏龙 《Chinese Physics C》 SCIE CAS CSCD 2012年第10期1019-1024,共6页
Geometric calibration is critical to the accurate SPECT reconstruction. In this paper, a geometric calibration method was developed for a dedicated breast SPECT system with a tilted parallel beam (TPB) orbit. The ac... Geometric calibration is critical to the accurate SPECT reconstruction. In this paper, a geometric calibration method was developed for a dedicated breast SPECT system with a tilted parallel beam (TPB) orbit. The acquisition geometry of the breast SPECT was firstly characterized. And then its projection model was established based on the acquisition geometry. Finally, the calibration results were obtained using a nonlinear optimization method that fitted the measured projections to the model. Monte Carlo data of the breast SPECT were used to verify the calibration method. Simulation results showed that the geometric parameters with reasonable accuracy could be obtained by the proposed method. 展开更多
关键词 geometric calibration acquisition geometry tilted parallel beam (TPB) breast SPECT Monte Carlo simulation
原文传递
上一页 1 下一页 到第