In order to improve the computation efficiency and simulation accuracy,a novel simplified simulation method for friction pendulum bearing( FPB) is proposed. The behavior of FPB was analyzed based on the stress charact...In order to improve the computation efficiency and simulation accuracy,a novel simplified simulation method for friction pendulum bearing( FPB) is proposed. The behavior of FPB was analyzed based on the stress characteristics of the slider of FPB. Then,a novel simplified FPB model with a single pendulum and a nonlinear spring was established. The mechanical behavior of the simplified model was analyzed and it conformed well to the basic requirements of FPB. Furthermore,shaking table tests of a concrete slab block structure isolated by four FPBs were carried out, followed by finite element simulations of the test using the proposed simplified model.Three waves and eleven loading scenarios were selected in the test. The results show that the overall trend of the relative displacement time-history curves,the horizontal acceleration time-history curves and the vertical acceleration time-history curves from the numerical simulation match in a good manner with those obtained from the tests. Specifically,it is found that the difference of the peak value within these curves between the simulation and test results is less than 15%,which means that the proposed simplified model can be used to simulate the FPB behaviors under dynamic loadings with acceptable accuracy for engineering purposes.展开更多
A finite element model is constructed for a sliding friction bearing in a seismically isolated bridge under vertical excitation with contact/friction elements. The effects of vertical excitation on the seismic perform...A finite element model is constructed for a sliding friction bearing in a seismically isolated bridge under vertical excitation with contact/friction elements. The effects of vertical excitation on the seismic performance of a seismically isolated bridge with sliding friction bearings and different bearing friction coefficients and different stiffness levels (pier diameter) are discussed using example calculations, and the effects of excitation direction for vertical excitation on the analysis results are explored. The analysis results shows that vertical excitation has a relatively large impact on seismic performance for a seismically isolated bridge with sliding friction bearings, which should be considered when designing a seismically isolated bridge with sliding friction bearings where vertical excitation dominates.展开更多
Reinforced concrete (r.c.) framed buildings designed in compliance with inadequate seismic classifi- cations and code provisions present in many cases a high vulnerability and need to be retrofitted. To this end, th...Reinforced concrete (r.c.) framed buildings designed in compliance with inadequate seismic classifi- cations and code provisions present in many cases a high vulnerability and need to be retrofitted. To this end, the insertion of a base isolation system allows a considerable reduction of the seismic loads transmitted to the super- structure. However, strong near-fault ground motions, which are characterised by long-duration horizontal pulses, may amplify the inelastic response of the superstructure and induce a failure of the isolation system. The above considerations point out the importance of checking the effectiveness of different isolation systems for retrofitting a r.c. framed structure. For this purpose, a numerical inves- tigation is carried out with reference to a six-storey r.c. framed building, which, primarily designed (as to be a fixed-base one) in compliance with the previous Italian code (DM96) for a medium-risk seismic zone, has to be retrofitted by insertion of an isolation system at the base for attaining performance levels imposed by the current Italian code (NTC08) in a high-risk seismic zone. Besides the (fixed-base) original structure, three cases of base isolation are studied: elastomeric bearings acting alone (e.g. HDLRBs); in-parallel combination of elastomeric and friction bearings (e.g. high-damping-laminated-rubber beatings, HDLRBs and steel-PTFE sliding bearings, SBs); friction bearings acting alone (e.g. friction pendulum bearings, FPBs). The nonlinear analysis of the fixed-base and base-isolated structures subjected to horizontal com- ponents of near-fault ground motions is performed for checking plastic conditions at the potential critical (end) sections of the girders and columns as well as critical conditions of the isolation systems. Unexpected high val- ues of ductility demand are highlighted at the lower floors of all base-isolated structures, while re-centring problems of the base isolation systems under near-fault earthquakes are expected in case of friction beatings acting alone (i.e. FPBs) or that in combination (i.e. SBs) with HDLRBs.展开更多
In this study, dynamic characteristics of the small base isolation system using new friction bearings are investigated by excitation experiment, and compared to other one using previous bearings. Peak amplitude of the...In this study, dynamic characteristics of the small base isolation system using new friction bearings are investigated by excitation experiment, and compared to other one using previous bearings. Peak amplitude of the acceleration response waves on the small base isolation system is decreased to about 10%-25% compared to the input waves. Also root mean square amplitude is decreased to about 10%-40%. In case of the ball embedded a cylindrical sponge, the new bearing, the damping ratio increases with increasing width of the cylindrical sponge. The natural frequency does not change. On the other hand, in case of the marble plate that is previous bearing, the damping ratio increases with increasing curvature radius of the marble plate, the natural frequency also increases. Therefore, the small base isolation system using new friction bearing provides better performance. The responses of the base isolation system indicate nonlinier effects by friction force.展开更多
During past strong earthquakes, highway bridges have sustained severe damage or even collapse due to excessive displacements and/or very large lateral forces. For commonly used isolation bearings with a pure friction ...During past strong earthquakes, highway bridges have sustained severe damage or even collapse due to excessive displacements and/or very large lateral forces. For commonly used isolation bearings with a pure friction sliding surface, seismic forces may be reduced but displacements are often unconstrained. In this paper, an alternative seismic bearing system, called the cable-sliding friction bearing system, is developed by integrating seismic isolation devices with displacement restrainers consisting of cables attached to the upper and lower plates of the bearing. Restoring forces are provided to limit the displacements of the sliding component. Design parameters including the length and stiffness of the cables, friction coefficient, strength of the shear bolt in a fixed-type bearing, and movements under earthquake excitations are discussed. Laboratory testing of a prototype bearing subjected to vertical loads and quasi-static cyclic lateral loads, and corresponding numerical finite element simulation analysis, were carried out. It is shown that the numerical simulation shows good agreement with the experimental force-displacement hysteretic response, indicating the viability of the new bearing system. In addition, practical application of this bearing system to a multi-span bridge in China and its design advantages are discussed.展开更多
With constant enlargement of the application areas of the spherical plain bearings,higher quality lubrication of the bearings is required.To solve the lubricating problems of spherical plain bearings under high temper...With constant enlargement of the application areas of the spherical plain bearings,higher quality lubrication of the bearings is required.To solve the lubricating problems of spherical plain bearings under high temperature,high vacuum,high speed,heavy loads and strong oxidation conditions,it is urgent for us to develop more excellent self-lubricating technologies.In this paper,the bonded solid lubricant coatings,which use inorganic phosphate as the binder,the mixture of MoS2 and graphite with two different weight proportions as the solid lubricant,are prepared by spraying under three different spray gun pressures.The bonding strength tests on the coatings show that the best spraying pressure is 0.2 MPa and the better mixing proportion of MoS2 to Graphite is 3:1.Then for the radial spherical plain bearings with steel/steel friction pair,after the coatings are made on the inner ring outer surfaces,the friction coefficient,the wear loss and the friction temperature of the bearings under four oscillating frequencies are investigated by a self-made tribo-tester.The test results,SEM of the worn morphologies and EDS of worn areas show that tribological properties of the bearing are obviously improved by the bonded solid lubricant coatings.When sprayed under the spray gun pressure of 0.2 MPa,the bearings have better anti-friction and anti-wear properties than those sprayed under 0.1 MPa and 0.3 MPa.Further as proved from the XPS analysis,between the coating with 3:1 mixing ratio of MoS2 to Graphite and the coating with 1:1 ratio,the former has less oxidation occurred on the surface and therefore has better tribological characteristics than the latter.This paper provides a reference to developing a new product of the radial spherical plain bearings with high bonding strength,oxidation resistance and abrasion resistance.展开更多
The concept of base isolation for storage racks is still a developing subject and has not been addressed in the recently updated seismic codes for storage racks.The friction pendulum bearing system(FPS)generates a nat...The concept of base isolation for storage racks is still a developing subject and has not been addressed in the recently updated seismic codes for storage racks.The friction pendulum bearing system(FPS)generates a natural period independent of the structure's seismic mass.This property makes FPS an ideal choice for isolating rack structures since merchandise may be placed on the racks in several possible arrangements.The results of a comprehensive parametric study aimed at evaluating the seismic performance of a four-shelf,two-bay selective pallet rack isolated with FPS is presented in this paper.The influence of radius of curvature of the FPS,seismic mass,and mass irregularity on the rack's seismic response is examined.The effect of variation of the coefficient of friction due to axial loading is studied by choosing friction values from two distinct friction characterization studies.The coefficient of friction calculated from these studies shows mild and significant variations,respectively,for the whole range of static axial loads expected on the isolator,and from different pallet mass arrangements considered.The optimum radius of curvature and the appropriate range of friction coefficient,for the defined range of static axial loads,to attain a desirable seismic performance are determined.展开更多
The seismic performance of medical systems is crucial for the seismic resilience of communities.The report summarizes the observed damage to twelve hospital buildings in the area affected by the MW 7.8 and MW 7.5 eart...The seismic performance of medical systems is crucial for the seismic resilience of communities.The report summarizes the observed damage to twelve hospital buildings in the area affected by the MW 7.8 and MW 7.5 earthquakes on February 6,2023 in Turkey.They include five base-isolated buildings and seven fixed-base buildings in southcentral Turkey's seven most heavily affected provinces.By relating the post-quake occupancy statuses of the hospitals with the estimated seismic demands during the earthquake doublet,the report offers the following observations:(1)the base-isolated hospital buildings on friction pendulum bearings generally exhibited superior performance of achieving the goal of immediate occupancy and provided better protection for nonstructural elements than fixed-base counterparts did;(2)the fixed-base hospital buildings of reinforced concrete structures constructed after 2001 successfully achieved the goal of collapse prevention even under very high seismic demands;(3)some fixed-base hospitals also remained operational even if they were very close to the fault rupture and were subjected to higher-than-design-level earthquake ground motions.展开更多
Variable curvature friction pendulum bearings(VCFPB)effectively reduce the dynamic response of storage tanks induced by earthquakes.Shaking table testing is used to assess the seismic performance of VCFPB isolated sto...Variable curvature friction pendulum bearings(VCFPB)effectively reduce the dynamic response of storage tanks induced by earthquakes.Shaking table testing is used to assess the seismic performance of VCFPB isolated storage tanks.However,the vertical pressure and friction coefficient of the scaled VCFPB in the shaking table tests cannot match the equivalent values of these parameters in the prototype.To avoid this drawback,a real-time hybrid simulation(RTHS)test was developed.Using RTHS testing,a 1/8 scaled tank isolated by VCFPB was tested.The experimental results showed that the displacement dynamic magnification factor of VCFPB,peak reduction factors of the acceleration,shear force,and overturning moment at bottom of the tank,were negative exponential functions of the ratio of peak ground acceleration(PGA)and friction coefficient.The peak reduction factors of displacement,acceleration,force and overturning moment,which were obtained from the experimental results,are compared with those calculated by the Housner model.It can be concluded that the Housner model is applicable in estimation of the acceleration,shear force,and overturning moment of liquid storage tank,but not for the sliding displacement of VCFPBs.展开更多
Complexity and implementation of design norms in Cameroon required a proven foreign expertise, but nowadays local engineers are mastering modern construction techniques. They are turning to pile foundations to solve t...Complexity and implementation of design norms in Cameroon required a proven foreign expertise, but nowadays local engineers are mastering modern construction techniques. They are turning to pile foundations to solve the problem of construction sites on weak soils. The objective of this work is to present the trend of the country pile-driving capacity of some foundations design and construction companies. The proposed analytical method is based on Finite Element Method and on the theory of wave's propagation and transmission along the pile taking into account experimental data on the construction site. The proposed method is validated through recorded data during the construction of the Mungo Bridge in Cameroon, and obtained analytical results are in agreement with experimental results.展开更多
The conventional dynamic control devices,such as fluid viscous damper(VFD)and isolating bearings,are unsuitable for the double-deck cable-stayed bridge due to a lack of sustainability,so it is necessary to introduce s...The conventional dynamic control devices,such as fluid viscous damper(VFD)and isolating bearings,are unsuitable for the double-deck cable-stayed bridge due to a lack of sustainability,so it is necessary to introduce some high-tech dynamic control devices to reduce dynamic response for double-deck cable-stayed bridges under earthquakes.A(90+128)m-span double-deck cable-stayed bridge with a steel truss beam is taken as the prototype bridge.A 3D finite element model is built to conduct the nonlinear time-history analysis of different site categories in fortification intensityⅨ(0.40 g)degree area.Two new types of dynamic control devices-cable sliding friction aseismic bearings(CSFABs)and elasticity fluid viscous dampers composite devices(EVFDs)are introduced to reduce the dynamic responses of double-deck cable-stayed bridges with steel truss beam.The parametric optimization design for the damping coefficient C and the elastic stiffness of spring K of EVFDs is conducted.The following conclusions are drawn:(1)The hybrid support system by EVFDs and CSFABs play a good function under both seismic and regular work,especially in eliminating the expansion joints damage;(2)The hybrid support system can reduce the beam-end displacement by 75%and the tower-bottom bending moment by 60%under the longitudinal seismic excitation.In addition,it can reduce the pier-bottom bending moment by at least 45%under transverse seismic and control the relative displacement between the pier and beam within 0.3 m.(3)Assuming the velocity indexα=0.3,the parametric optimization suggests the damping coefficient C as 2000 kN·s·m-1in siteⅠ0,4000kN·s·m-1in siteⅡ,6000 kN·s·m-1in siteⅣ,and the elastic stiffness of spring K as 10000 kN/m in siteⅠ0,50000 kN/m in siteⅡ,and 100000 kN/m in siteⅣ.展开更多
This paper presents the model of calculating the total friction moment of space gyroscope ball bearings which usually work under ultra-low oscillatory motion and are very sensitive to the friction moment. The aim is t...This paper presents the model of calculating the total friction moment of space gyroscope ball bearings which usually work under ultra-low oscillatory motion and are very sensitive to the friction moment. The aim is to know the proportion of the friction moment caused by each frictional source in the bearing's total friction moment, which is helpful to optimize the bearing design to deduce the friction moment. In the model, the cage dynamic equations considering six degree-of-freedom and the balls dynamic equations considering two degree-of-freedom were solved.The good trends with different loads between the measured friction moments and computational results prove that the model under constant rate was validated. The computational results show that when the speed was set at 5 r/min, the bearing's maximum total friction moment when oscillation occurred was obviously larger than that occurred at a constant rate. At the onset of each oscillatory motion, the proportion of the friction moment caused by cage in the bearing's total friction moment was very high, and it increased with the increasing speed. The analyses of different cage thicknesses and different clearances between cage pocket and ball show that smaller thickness and clearance were preferred.展开更多
The horizontal stiffness of the isolated layer is reduced substantially by a friction pendulum bearing(FPB)toprotectthe structure from potential damages caused by earthquakes.However,horizontal stiffness is essential ...The horizontal stiffness of the isolated layer is reduced substantially by a friction pendulum bearing(FPB)toprotectthe structure from potential damages caused by earthquakes.However,horizontal stiffness is essential to progressive collapse resistance of structures.This paper presents a simplified model to assess the progressive collapse response of beam-pier substructure isolated by FPB.Progressive collapse resistance by flexural action of the beam and additional resistance owing to the horizontal restraining force was achieved.The influences of the equivalent radius and friction coefficient of the FPB,the applied axial force on the FPB,and span-depth ratio of the beam on the additional resistance were investigated.Simulations were conducted to verify the proposed model.The results show that progressive collapse resistance provided by horizontal restraining can be reduced as large as 46%and 88%during compressive arching action(CAA)and catenary action(CA),respectively.The equivalent radius of the FPB shows limited effect on the progressive collapse response of FPB isolated structures,but friction coefficient and applied axial force,as well as depth ratio of the beam,show significant influences on the additional progressive collapse resistance capacity.Finite element method(FEM)results are in good agreement with the result obtained by the proposed method.展开更多
基金The National Natural Science Foundation of China(No.6505000184)the National Key Research and Development Program of China(No.2016YFC0701400)
文摘In order to improve the computation efficiency and simulation accuracy,a novel simplified simulation method for friction pendulum bearing( FPB) is proposed. The behavior of FPB was analyzed based on the stress characteristics of the slider of FPB. Then,a novel simplified FPB model with a single pendulum and a nonlinear spring was established. The mechanical behavior of the simplified model was analyzed and it conformed well to the basic requirements of FPB. Furthermore,shaking table tests of a concrete slab block structure isolated by four FPBs were carried out, followed by finite element simulations of the test using the proposed simplified model.Three waves and eleven loading scenarios were selected in the test. The results show that the overall trend of the relative displacement time-history curves,the horizontal acceleration time-history curves and the vertical acceleration time-history curves from the numerical simulation match in a good manner with those obtained from the tests. Specifically,it is found that the difference of the peak value within these curves between the simulation and test results is less than 15%,which means that the proposed simplified model can be used to simulate the FPB behaviors under dynamic loadings with acceptable accuracy for engineering purposes.
基金National Natural Science Foundation of China under Grant Nos.51368036 and 51108220
文摘A finite element model is constructed for a sliding friction bearing in a seismically isolated bridge under vertical excitation with contact/friction elements. The effects of vertical excitation on the seismic performance of a seismically isolated bridge with sliding friction bearings and different bearing friction coefficients and different stiffness levels (pier diameter) are discussed using example calculations, and the effects of excitation direction for vertical excitation on the analysis results are explored. The analysis results shows that vertical excitation has a relatively large impact on seismic performance for a seismically isolated bridge with sliding friction bearings, which should be considered when designing a seismically isolated bridge with sliding friction bearings where vertical excitation dominates.
基金financed by Re.L.U.I.S.(Italian network of university laboratories of earthquake engineering),under the project "Convenzione D.P.C.-Re.L.U.I.S. 2014-2016,WPI,Isolation and Dissipation"
文摘Reinforced concrete (r.c.) framed buildings designed in compliance with inadequate seismic classifi- cations and code provisions present in many cases a high vulnerability and need to be retrofitted. To this end, the insertion of a base isolation system allows a considerable reduction of the seismic loads transmitted to the super- structure. However, strong near-fault ground motions, which are characterised by long-duration horizontal pulses, may amplify the inelastic response of the superstructure and induce a failure of the isolation system. The above considerations point out the importance of checking the effectiveness of different isolation systems for retrofitting a r.c. framed structure. For this purpose, a numerical inves- tigation is carried out with reference to a six-storey r.c. framed building, which, primarily designed (as to be a fixed-base one) in compliance with the previous Italian code (DM96) for a medium-risk seismic zone, has to be retrofitted by insertion of an isolation system at the base for attaining performance levels imposed by the current Italian code (NTC08) in a high-risk seismic zone. Besides the (fixed-base) original structure, three cases of base isolation are studied: elastomeric bearings acting alone (e.g. HDLRBs); in-parallel combination of elastomeric and friction bearings (e.g. high-damping-laminated-rubber beatings, HDLRBs and steel-PTFE sliding bearings, SBs); friction bearings acting alone (e.g. friction pendulum bearings, FPBs). The nonlinear analysis of the fixed-base and base-isolated structures subjected to horizontal com- ponents of near-fault ground motions is performed for checking plastic conditions at the potential critical (end) sections of the girders and columns as well as critical conditions of the isolation systems. Unexpected high val- ues of ductility demand are highlighted at the lower floors of all base-isolated structures, while re-centring problems of the base isolation systems under near-fault earthquakes are expected in case of friction beatings acting alone (i.e. FPBs) or that in combination (i.e. SBs) with HDLRBs.
文摘In this study, dynamic characteristics of the small base isolation system using new friction bearings are investigated by excitation experiment, and compared to other one using previous bearings. Peak amplitude of the acceleration response waves on the small base isolation system is decreased to about 10%-25% compared to the input waves. Also root mean square amplitude is decreased to about 10%-40%. In case of the ball embedded a cylindrical sponge, the new bearing, the damping ratio increases with increasing width of the cylindrical sponge. The natural frequency does not change. On the other hand, in case of the marble plate that is previous bearing, the damping ratio increases with increasing curvature radius of the marble plate, the natural frequency also increases. Therefore, the small base isolation system using new friction bearing provides better performance. The responses of the base isolation system indicate nonlinier effects by friction force.
基金Ministry of Science and Technology of China Under Grant No. SLDRCE09-B-08Kwang-Hua Fund for College of Civil Engineering, Tongji Universitythe National Natural Science Foundation of China Under Grants No.50978194 and No.90915011
文摘During past strong earthquakes, highway bridges have sustained severe damage or even collapse due to excessive displacements and/or very large lateral forces. For commonly used isolation bearings with a pure friction sliding surface, seismic forces may be reduced but displacements are often unconstrained. In this paper, an alternative seismic bearing system, called the cable-sliding friction bearing system, is developed by integrating seismic isolation devices with displacement restrainers consisting of cables attached to the upper and lower plates of the bearing. Restoring forces are provided to limit the displacements of the sliding component. Design parameters including the length and stiffness of the cables, friction coefficient, strength of the shear bolt in a fixed-type bearing, and movements under earthquake excitations are discussed. Laboratory testing of a prototype bearing subjected to vertical loads and quasi-static cyclic lateral loads, and corresponding numerical finite element simulation analysis, were carried out. It is shown that the numerical simulation shows good agreement with the experimental force-displacement hysteretic response, indicating the viability of the new bearing system. In addition, practical application of this bearing system to a multi-span bridge in China and its design advantages are discussed.
基金Supported by National Natural Science Foundation of China(Grant No.51275155)Henan Provincial Science and Technology Innovation Outstanding Talent Project of China(Grant No.154200510013)Henan Provincial Innovation and Research Team of Science and Technology in Universities of China(Grant No.13IRTSTHN025)
文摘With constant enlargement of the application areas of the spherical plain bearings,higher quality lubrication of the bearings is required.To solve the lubricating problems of spherical plain bearings under high temperature,high vacuum,high speed,heavy loads and strong oxidation conditions,it is urgent for us to develop more excellent self-lubricating technologies.In this paper,the bonded solid lubricant coatings,which use inorganic phosphate as the binder,the mixture of MoS2 and graphite with two different weight proportions as the solid lubricant,are prepared by spraying under three different spray gun pressures.The bonding strength tests on the coatings show that the best spraying pressure is 0.2 MPa and the better mixing proportion of MoS2 to Graphite is 3:1.Then for the radial spherical plain bearings with steel/steel friction pair,after the coatings are made on the inner ring outer surfaces,the friction coefficient,the wear loss and the friction temperature of the bearings under four oscillating frequencies are investigated by a self-made tribo-tester.The test results,SEM of the worn morphologies and EDS of worn areas show that tribological properties of the bearing are obviously improved by the bonded solid lubricant coatings.When sprayed under the spray gun pressure of 0.2 MPa,the bearings have better anti-friction and anti-wear properties than those sprayed under 0.1 MPa and 0.3 MPa.Further as proved from the XPS analysis,between the coating with 3:1 mixing ratio of MoS2 to Graphite and the coating with 1:1 ratio,the former has less oxidation occurred on the surface and therefore has better tribological characteristics than the latter.This paper provides a reference to developing a new product of the radial spherical plain bearings with high bonding strength,oxidation resistance and abrasion resistance.
文摘The concept of base isolation for storage racks is still a developing subject and has not been addressed in the recently updated seismic codes for storage racks.The friction pendulum bearing system(FPS)generates a natural period independent of the structure's seismic mass.This property makes FPS an ideal choice for isolating rack structures since merchandise may be placed on the racks in several possible arrangements.The results of a comprehensive parametric study aimed at evaluating the seismic performance of a four-shelf,two-bay selective pallet rack isolated with FPS is presented in this paper.The influence of radius of curvature of the FPS,seismic mass,and mass irregularity on the rack's seismic response is examined.The effect of variation of the coefficient of friction due to axial loading is studied by choosing friction values from two distinct friction characterization studies.The coefficient of friction calculated from these studies shows mild and significant variations,respectively,for the whole range of static axial loads expected on the isolator,and from different pallet mass arrangements considered.The optimum radius of curvature and the appropriate range of friction coefficient,for the defined range of static axial loads,to attain a desirable seismic performance are determined.
基金jointly sponsored by the Institute of Engineering Mechanicsthe Natural Science Foundation of China(No.52122811)。
文摘The seismic performance of medical systems is crucial for the seismic resilience of communities.The report summarizes the observed damage to twelve hospital buildings in the area affected by the MW 7.8 and MW 7.5 earthquakes on February 6,2023 in Turkey.They include five base-isolated buildings and seven fixed-base buildings in southcentral Turkey's seven most heavily affected provinces.By relating the post-quake occupancy statuses of the hospitals with the estimated seismic demands during the earthquake doublet,the report offers the following observations:(1)the base-isolated hospital buildings on friction pendulum bearings generally exhibited superior performance of achieving the goal of immediate occupancy and provided better protection for nonstructural elements than fixed-base counterparts did;(2)the fixed-base hospital buildings of reinforced concrete structures constructed after 2001 successfully achieved the goal of collapse prevention even under very high seismic demands;(3)some fixed-base hospitals also remained operational even if they were very close to the fault rupture and were subjected to higher-than-design-level earthquake ground motions.
基金Scientific Research Fund of Institute of Engineering Mechanics,China Earthquake Administration under Grant No.2018D03the National Natural Science Foundation of China under Grant Nos.51608016 and 51421005。
文摘Variable curvature friction pendulum bearings(VCFPB)effectively reduce the dynamic response of storage tanks induced by earthquakes.Shaking table testing is used to assess the seismic performance of VCFPB isolated storage tanks.However,the vertical pressure and friction coefficient of the scaled VCFPB in the shaking table tests cannot match the equivalent values of these parameters in the prototype.To avoid this drawback,a real-time hybrid simulation(RTHS)test was developed.Using RTHS testing,a 1/8 scaled tank isolated by VCFPB was tested.The experimental results showed that the displacement dynamic magnification factor of VCFPB,peak reduction factors of the acceleration,shear force,and overturning moment at bottom of the tank,were negative exponential functions of the ratio of peak ground acceleration(PGA)and friction coefficient.The peak reduction factors of displacement,acceleration,force and overturning moment,which were obtained from the experimental results,are compared with those calculated by the Housner model.It can be concluded that the Housner model is applicable in estimation of the acceleration,shear force,and overturning moment of liquid storage tank,but not for the sliding displacement of VCFPBs.
文摘Complexity and implementation of design norms in Cameroon required a proven foreign expertise, but nowadays local engineers are mastering modern construction techniques. They are turning to pile foundations to solve the problem of construction sites on weak soils. The objective of this work is to present the trend of the country pile-driving capacity of some foundations design and construction companies. The proposed analytical method is based on Finite Element Method and on the theory of wave's propagation and transmission along the pile taking into account experimental data on the construction site. The proposed method is validated through recorded data during the construction of the Mungo Bridge in Cameroon, and obtained analytical results are in agreement with experimental results.
文摘The conventional dynamic control devices,such as fluid viscous damper(VFD)and isolating bearings,are unsuitable for the double-deck cable-stayed bridge due to a lack of sustainability,so it is necessary to introduce some high-tech dynamic control devices to reduce dynamic response for double-deck cable-stayed bridges under earthquakes.A(90+128)m-span double-deck cable-stayed bridge with a steel truss beam is taken as the prototype bridge.A 3D finite element model is built to conduct the nonlinear time-history analysis of different site categories in fortification intensityⅨ(0.40 g)degree area.Two new types of dynamic control devices-cable sliding friction aseismic bearings(CSFABs)and elasticity fluid viscous dampers composite devices(EVFDs)are introduced to reduce the dynamic responses of double-deck cable-stayed bridges with steel truss beam.The parametric optimization design for the damping coefficient C and the elastic stiffness of spring K of EVFDs is conducted.The following conclusions are drawn:(1)The hybrid support system by EVFDs and CSFABs play a good function under both seismic and regular work,especially in eliminating the expansion joints damage;(2)The hybrid support system can reduce the beam-end displacement by 75%and the tower-bottom bending moment by 60%under the longitudinal seismic excitation.In addition,it can reduce the pier-bottom bending moment by at least 45%under transverse seismic and control the relative displacement between the pier and beam within 0.3 m.(3)Assuming the velocity indexα=0.3,the parametric optimization suggests the damping coefficient C as 2000 kN·s·m-1in siteⅠ0,4000kN·s·m-1in siteⅡ,6000 kN·s·m-1in siteⅣ,and the elastic stiffness of spring K as 10000 kN/m in siteⅠ0,50000 kN/m in siteⅡ,and 100000 kN/m in siteⅣ.
基金supports from the National ‘‘the eleventh-five years’’ Projects of Science and Technology under contract (No. D09-0109-06-004) of ChinaInnovative Team Program of Universities in Shanghai of Shanghai Municipality Education Commission (No. B-48-0109-09-002) of China
文摘This paper presents the model of calculating the total friction moment of space gyroscope ball bearings which usually work under ultra-low oscillatory motion and are very sensitive to the friction moment. The aim is to know the proportion of the friction moment caused by each frictional source in the bearing's total friction moment, which is helpful to optimize the bearing design to deduce the friction moment. In the model, the cage dynamic equations considering six degree-of-freedom and the balls dynamic equations considering two degree-of-freedom were solved.The good trends with different loads between the measured friction moments and computational results prove that the model under constant rate was validated. The computational results show that when the speed was set at 5 r/min, the bearing's maximum total friction moment when oscillation occurred was obviously larger than that occurred at a constant rate. At the onset of each oscillatory motion, the proportion of the friction moment caused by cage in the bearing's total friction moment was very high, and it increased with the increasing speed. The analyses of different cage thicknesses and different clearances between cage pocket and ball show that smaller thickness and clearance were preferred.
基金This research was supported by the National Key Research and Development Program of China(No.2017YFC0703603).
文摘The horizontal stiffness of the isolated layer is reduced substantially by a friction pendulum bearing(FPB)toprotectthe structure from potential damages caused by earthquakes.However,horizontal stiffness is essential to progressive collapse resistance of structures.This paper presents a simplified model to assess the progressive collapse response of beam-pier substructure isolated by FPB.Progressive collapse resistance by flexural action of the beam and additional resistance owing to the horizontal restraining force was achieved.The influences of the equivalent radius and friction coefficient of the FPB,the applied axial force on the FPB,and span-depth ratio of the beam on the additional resistance were investigated.Simulations were conducted to verify the proposed model.The results show that progressive collapse resistance provided by horizontal restraining can be reduced as large as 46%and 88%during compressive arching action(CAA)and catenary action(CA),respectively.The equivalent radius of the FPB shows limited effect on the progressive collapse response of FPB isolated structures,but friction coefficient and applied axial force,as well as depth ratio of the beam,show significant influences on the additional progressive collapse resistance capacity.Finite element method(FEM)results are in good agreement with the result obtained by the proposed method.