Continuous processes which allow for large amount of wastewater to be treated to meet drainage standards while reducing treatment time and energy consumption are urgently needed. In this study, a dielectric barrier di...Continuous processes which allow for large amount of wastewater to be treated to meet drainage standards while reducing treatment time and energy consumption are urgently needed. In this study, a dielectric barrier discharge plasma water bed system was designed and then coupled with granular activated carbon (GAC) adsorption to rapidly remove acid fuchsine (AF) with high efficiency. Effects of feeding gases, treatment time and initial concentration of AF on removal efficiency were investigated. Results showed that compared to the N2 and air plasmas treatments, O2 plasma processing was most effective for AF degradation due to the strong oxidation ability of generated activated species, especially the OH radicals. The addition of GAC significantly enhanced the removal efficiency of AF in aqueous solution and shorten the required time by 50%. The effect was attributed to the ability of porous carbon to trap and concentrate the dye, increasing the time dye molecules were exposed to the plasma discharge zone, and to enhance the production of OH radicals on/in GAC to boost the degradation of dyes by plasma as well as in situ regenerate the exhausted GAC. The study offers a new opportunity for continuous effective remediation of wastewater contaminated with organic dyes using plasma technologies.展开更多
Non-thermal plasma technology is a new type of odor treatment processing.We deal with H2Sfrom waste gas emission using non-thermal plasma generated by dielectric barrier discharge.On the basis of two criteria,removal ...Non-thermal plasma technology is a new type of odor treatment processing.We deal with H2Sfrom waste gas emission using non-thermal plasma generated by dielectric barrier discharge.On the basis of two criteria,removal efficiency and absolute removal amount,we deeply investigate the changes in electrical parameters and process parameters,and the reaction process of the influence of ozone on H2S gas removal.The experimental results show that H2S removal efficiency is proportional to the voltage,frequency,power,residence time and energy efficiency,while it is inversely proportional to the initial concentration of H2S gas,and ozone concentration.This study lays the foundations of non-thermal plasma technology for further commercial application.展开更多
基金the National Natural Science Foundation of China (Grant No.51877184)the Central Analytical Research Facility operated by the Institute of Future Environment (QUT).
文摘Continuous processes which allow for large amount of wastewater to be treated to meet drainage standards while reducing treatment time and energy consumption are urgently needed. In this study, a dielectric barrier discharge plasma water bed system was designed and then coupled with granular activated carbon (GAC) adsorption to rapidly remove acid fuchsine (AF) with high efficiency. Effects of feeding gases, treatment time and initial concentration of AF on removal efficiency were investigated. Results showed that compared to the N2 and air plasmas treatments, O2 plasma processing was most effective for AF degradation due to the strong oxidation ability of generated activated species, especially the OH radicals. The addition of GAC significantly enhanced the removal efficiency of AF in aqueous solution and shorten the required time by 50%. The effect was attributed to the ability of porous carbon to trap and concentrate the dye, increasing the time dye molecules were exposed to the plasma discharge zone, and to enhance the production of OH radicals on/in GAC to boost the degradation of dyes by plasma as well as in situ regenerate the exhausted GAC. The study offers a new opportunity for continuous effective remediation of wastewater contaminated with organic dyes using plasma technologies.
基金supported by the Open Project Program of State Key Laboratory of Petroleum Pollution Control(No.PPC2017010)CNPC Research Institute of Safety and Environmental Technology,and State Key Laboratory of Solid Waste Reuse for Building Materials(SWR2017002)+2 种基金National Natural Science Foundation of China(No.51108453)Program for New Century Excellent Talents in University(No.NCET120967)the Fundamental Research Funds for the Central Universities(No.2009QH03)
文摘Non-thermal plasma technology is a new type of odor treatment processing.We deal with H2Sfrom waste gas emission using non-thermal plasma generated by dielectric barrier discharge.On the basis of two criteria,removal efficiency and absolute removal amount,we deeply investigate the changes in electrical parameters and process parameters,and the reaction process of the influence of ozone on H2S gas removal.The experimental results show that H2S removal efficiency is proportional to the voltage,frequency,power,residence time and energy efficiency,while it is inversely proportional to the initial concentration of H2S gas,and ozone concentration.This study lays the foundations of non-thermal plasma technology for further commercial application.