期刊文献+
共找到4,378篇文章
< 1 2 219 >
每页显示 20 50 100
Vertically aligned montmorillonite aerogel-encapsulated polyethylene glycol with directional heat transfer paths for efficient solar thermal energy harvesting and storage
1
作者 Qijing Guo Cong Guo +2 位作者 Hao Yi Feifei Jia Shaoxian Song 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2024年第5期907-916,共10页
The conversion and storage of photothermal energy using phase change materials(PCMs)represent an optimal approach for harnessing clean and sustainable solar energy.Herein,we encapsulated polyethylene glycol(PEG)in mon... The conversion and storage of photothermal energy using phase change materials(PCMs)represent an optimal approach for harnessing clean and sustainable solar energy.Herein,we encapsulated polyethylene glycol(PEG)in montmorillonite aerogels(3D-Mt)through vacuum impregnation to prepare 3D-Mt/PEG composite PCMs.When used as a support matrix,3D-Mt can effectively prevent PEG leakage and act as a flame-retardant barrier to reduce the flammability of PEG.Simultaneously,3D-Mt/PEG demonstrates outstanding shape retention,increased thermal energy storage density,and commendable thermal and chemical stability.The phase transition enthalpy of 3D-Mt/PEG can reach 167.53 J/g and remains stable even after 50 heating-cooling cycles.Furthermore,the vertical sheet-like structure of 3D-Mt establishes directional heat transport channels,facilitating efficient phonon transfer.This configuration results in highly anisotropic thermal conductivities that ensure swift thermal responses and efficient heat conduction.This study addresses the shortcomings of PCMs,including the issues of leakage and inadequate flame retardancy.It achieves the development and design of 3D-Mt/PEG with ultrahigh strength,superior flame retardancy,and directional heat transfer.Therefore,this work offers a design strategy for the preparation of high-performance composite PCMs.The 3D-Mt/PEG with vertically aligned and well-ordered array structure developed in this research shows great potential for thermal management and photothermal conversion applications. 展开更多
关键词 montmorillonite aerogel polyethylene glycol phase change materials solar thermal energy storage flame retardant
下载PDF
Hyponatremic encephalopathy due to polyethylene glycol-based bowel preparation for colonoscopy:A case report 被引量:1
2
作者 Yuan Zhao Hai-Sheng Dong 《World Journal of Clinical Cases》 SCIE 2023年第1期187-192,共6页
BACKGROUND Adequate bowel preparation is critical for colonoscopy screening.At present,the most widely used intestinal cleaner recommended at home and abroad is Polyethylene glycol(PEG).Intestinal cleansers can cause ... BACKGROUND Adequate bowel preparation is critical for colonoscopy screening.At present,the most widely used intestinal cleaner recommended at home and abroad is Polyethylene glycol(PEG).Intestinal cleansers can cause electrolyte disturbances and hyponatremia.However,hyponatremic encephalopathy due to hyponatremia induced by PEG solution,although rare,can lead to serious irreversible sequelae and even death.CASE SUMMARY In this report,we discuss a case of neurological dysfunction due to hyponatremia,also known as hyponatremic encephalopathy,observed in a 63-year-old woman who underwent PEG-based bowel preparation for colonoscopy.She was eventually transferred to our intensive care unit for treatment due to her Glasgow Coma Scale score of 9/15(Eye opening 2;Verbal response 1;Motor response 6)and abnormal laboratory tests.CONCLUSION Physicians should be thoroughly familiarized with the patient’s history before prescribing PEG for bowel preparation,and timely identification of patients with hyponatremic encephalopathy is essential as delayed treatment is associated with poor neurological outcomes.An intravenous infusion of 3%sodium chloride is recommended at the onset of early symptoms.The goal of treatment is to adequately treat cerebral edema while avoiding serum sodium correction beyond 15 to 20 m Eq/L within 48 h of treatment to prevent osmotic demyelination syndrome. 展开更多
关键词 polyethylene glycol Intestinal preparation Hyponatremic encephalopathy HYPONATREMIA BRAIN Case report
下载PDF
Anaphylactic shock induced by polyethylene glycol after bowel preparation for the colorectal cancer surgery:A case report
3
作者 Go Woon Park Nahyeon Park +2 位作者 Jung Cheol Kuk Eung Jin Shin Dae Ro Lim 《World Journal of Clinical Cases》 SCIE 2023年第23期5589-5594,共6页
BACKGROUND Polyethylene glycol(PEG)is widely used as an additive because of its hydrophilic and chemically inert properties.However,there are been increasing reports of PEG allergies,including anaphylaxis,although the... BACKGROUND Polyethylene glycol(PEG)is widely used as an additive because of its hydrophilic and chemically inert properties.However,there are been increasing reports of PEG allergies,including anaphylaxis,although they are still rare.This case report aims to raise awareness,that the commonly used bowel cleansing agent containing PEG can cause serious allergic reactions.CASE SUMMARY Prior to surgery for sigmoid colon cancer,a 63-year-old man was prescribed a bowel cleansing agent containing PEG.Within 30 min of ingestion,he developed symptoms of anaphylactic shock and did not respond to initial intramuscular epinephrine injection.Under diagnosis of anaphylaxis to PEG,he was stabilized with fluid hydration and continuous norepinephrine infusion.CONCLUSION While allergic reactions to PEG are rare,they can be life-threatening.Therefore,it is crucial for clinicians to be aware of this possibility and to diagnose and resuscitate patients immediately. 展开更多
关键词 polyethylene glycol ANAPHYLAXIS Sigmoid colon cancer Bowel preparation Case report
下载PDF
Immunohistochemical evidence of axonal regrowth across polyethylene glycol-fused cervical cords in mice 被引量:5
4
作者 C-Yoon Kim Hanseul Oh +1 位作者 Xiaoping Ren Sergio Canavero 《Neural Regeneration Research》 SCIE CAS CSCD 2017年第1期149-150,共2页
It is generally accepted that a severed spinal cord is associated with permanent paralysis.Recently,a spinal cord fusion protocol(GEMINI)has been proposed,whereby an acutely controlled,sharp,operative transection of... It is generally accepted that a severed spinal cord is associated with permanent paralysis.Recently,a spinal cord fusion protocol(GEMINI)has been proposed,whereby an acutely controlled,sharp,operative transection of the spinal cord is carried out. 展开更多
关键词 axonal polyethylene glycol permanent paralysis cords traumatic fused comparable sharp
下载PDF
Recent Advances of D-α-tocopherol Polyethylene Glycol 1000 Succinate Based Stimuli-responsive Nanomedicine for Cancer Treatment 被引量:2
5
作者 Yang GUAN Lin-yan WANG +3 位作者 Bo WANG Mei-bong DING Yu-ling BAO Song-wei TAN 《Current Medical Science》 SCIE CAS 2020年第2期218-231,共14页
D-a-tocopherol polyethylene glycol 1000 succinate(TPGS)is a pharmaceutical excipient approved by Chinese NMPA and FDA of USA.It's widely applied as a multifunctional drug carrier for nanomedicine.The advantages of... D-a-tocopherol polyethylene glycol 1000 succinate(TPGS)is a pharmaceutical excipient approved by Chinese NMPA and FDA of USA.It's widely applied as a multifunctional drug carrier for nanomedicine.The advantages of TPGS include P-glycoprotein(P-gp)inhibition,penetration promotion,apoptosis induction via mitochondrial-associated apoptotic pathways,multidrug resistant(MDR)reversion,metastasis inhibition and so on.TPGS-based drug delivery systems which are responding to extermal stimulus can combine the inhibitory functions of TPGS towards P-gp with the environmentally responsive controlled release property and thus exerts a synergistic anti-cancer effect,through increased intracellular drug concentration in tumors cells and well-controlled drug release behavior.In this review,TPGS-based nano-sized delivery systems responsive to different stimuli were summarized and discussed,including pH-responsive,redox-responsive and multi-responsive systems in various formulations.The achievements,mechanisms and diffcrent characteristics of TPGS-bascd stimuli-responsive drug-delivery systems in tumor therapy were also outlined. 展开更多
关键词 D-a-tocopherol polyethylene glycol 1000 succinate STIMULI-RESPONSIVE NANOMEDICINE P-GLYCOPROTEIN cancer
下载PDF
Polymerization of Bisphenol A Epoxy Resin with Polyethylene glycol 被引量:2
6
作者 Zhen Zhong YANG De Lu ZHAo Mao XU(Polymer Physics Laboratory, Institute of Chemistry, The Chinese Academy of Sciences, Beijing 100080) 《Chinese Chemical Letters》 SCIE CAS CSCD 1997年第8期725-728,共4页
The catalyst boron trifluoride etherate was used to catalyze the reaction of epoxy resin with polyethylene glycol (PEG), and the effect of the concentration of the catalyst on the reaction is studied. It is shown that... The catalyst boron trifluoride etherate was used to catalyze the reaction of epoxy resin with polyethylene glycol (PEG), and the effect of the concentration of the catalyst on the reaction is studied. It is shown that there exist two competitive reactions : I, self polymerization of epoxy resin via chain growth and II, copolymerization of epoxy resin with PEG via step growth. At high concentration of the catalyst reaction I dominates and reaction II is negligible. On the contrary, at low concentration of the catalyst, reaction II dominates and block copolymers are formed In the intermediate case, the two reactions are comparable with the result that a gel structure is obtained. 展开更多
关键词 PEG Polymerization of Bisphenol A Epoxy Resin with polyethylene glycol
下载PDF
Dielectric Behaviour of Mixtures of Polyethylene Glycol with Propionaldehyde and Benzaldehyde
7
作者 I.M.El-Anwar and I.Z.Selim(Physical Chemistry Dept., National Research Center, Dokki, Cairo, Egypt)( To whom correspondence should be addressed)(To whom correspondence should be addressed)A.A.Foad(Faculty of Science, Helwan University, Helwan, Cairo, Egyp 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 1995年第5期373-379,共7页
The dielectric constant e' and dielectric loss e' of several mixtures of propionaldehyde-polyethylene glycol (system 1) and benzaldehyde-polyethylene glycol (system II) have been measured within the frequency ... The dielectric constant e' and dielectric loss e' of several mixtures of propionaldehyde-polyethylene glycol (system 1) and benzaldehyde-polyethylene glycol (system II) have been measured within the frequency band 105-107 Hz and the temperature range 20-50℃. The dielectric behaviour is discussed. on the other hand, the dielectric relaxation time T. activation energy △He, and entorpy change △Se for the dielectric relaxation as well as activation energy of viscous flow △Hv are calculated for the same temperature range. It is suggested that the observed increase in T values with increas.ng glycol content is due to an increase in the hydrogen bonding in the aggregates or clusters which would be formed between the carbonyl group of the aldehyde and the hydrogen atoms from the glycot molecules. In addition, the higher values of T, △He, and △Se in case of system (II) than that in case of system (I) may be due to the greater volume of the aggregates and the stronger dipole-dipole forces in system (II) compared with those in system (I). 展开更多
关键词 II FIGURE Dielectric Behaviour of Mixtures of polyethylene glycol with Propionaldehyde and Benzaldehyde
下载PDF
Studies on the Absorption of NO_2 by Polyethylene Glycol and the Oxidizing Properties of the Resulting Absorbent Product
8
作者 Xue Sen FAN Qing Zhi ZHANG +1 位作者 Xin Ying ZRANG Sen Song ZHANG (Department of Chemistry, Henan Normal University, Xinxiang, 453002) 《Chinese Chemical Letters》 SCIE CAS CSCD 1997年第9期747-748,共2页
PEG (Polyethylene glycol average molecular weight 300) is used as absorbent of NO2. The absorption efficiency is found to reach up to 97%. The absorbing product, PEG NO2, can be used to cleave benzyl ethers mildly a... PEG (Polyethylene glycol average molecular weight 300) is used as absorbent of NO2. The absorption efficiency is found to reach up to 97%. The absorbing product, PEG NO2, can be used to cleave benzyl ethers mildly and selectively to benzaldehyde and corresponding fatty alcohols, showing that PEG is a valuable oxidizing agent of benzyl ethers. As a carrier of NO2.PEG can be recovered and utilized repeatedly after the oxidation. 展开更多
关键词 NO Studies on the Absorption of NO2 by polyethylene glycol and the Oxidizing Properties of the Resulting Absorbent Product PEG
下载PDF
Density,refractive index and liquid–liquid equilibrium data of polyethylene glycol 3000 + potassium formate + water at different pH values
9
作者 Fatemeh Ahmadi Mohsen Pirdashti Abbas Ali Rostami 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2018年第1期168-174,共7页
New liquid-liquid equilibrium data for polyethylene glycol (PEG) 3000 + CHO2K + H20 systems were measured at 298.15 K and pH values of 7.95, 8.40 and 9.98. It was found that an increase in pH caused the binodal cu... New liquid-liquid equilibrium data for polyethylene glycol (PEG) 3000 + CHO2K + H20 systems were measured at 298.15 K and pH values of 7.95, 8.40 and 9.98. It was found that an increase in pH caused the binodal curve to be displaced downward and the two-phase region to expand. Accordingly, the binodal curve was adjusted to the Pirdashti equation and the tie-line compositions were correlated using the Othmer-Tobias, Bancroft and Hand equations. The study measured the refractive index and densities of several homogeneous binary and ternary solutions. The solutions were used for calibration within a range of 0% to 30% of the mass of the PEG and potassium formate. The density and refractive index data show a linear variation with the mass fraction of the polymer and the salt. The effect of pH on the binodal, tie-line lengths (TLL) and slope of the tie-line (STL) in the systems was exam- ined. It was found that an increase in pH increased the TLL and decreased the STL It was observed that the density of the aqueous two-phase system was influenced by the TLL The difference in density between phases (△p) increased as the TLL and pH increased. It was found that the TLL and Ap showed a linear relationship. The effective excluded volume (EEV) of the PEG was obtained and it was found that EEV also increased as the pH increased. 展开更多
关键词 Liquid-liquid equilibrium data Density polyethylene glycol Potassium formate
下载PDF
Comparison of Usage and Effectiveness between Methoxy Polyethylene Glycol Epoetin Beta and Darbepoetin Alfa with Hemodialysis Patients
10
作者 Jiyeong Yoon Beung Koo Lee +2 位作者 Hyesun Gwak Jeongmee Kim Youngmee Lee 《Journal of Pharmacy and Pharmacology》 2015年第4期182-190,共9页
Methoxy polyethylene glycol epoetin beta which has a long half-life is developed to provide stable control of hemoglobin levels at extended administration intervals compared to darbepoetin alfa. The purpose of this st... Methoxy polyethylene glycol epoetin beta which has a long half-life is developed to provide stable control of hemoglobin levels at extended administration intervals compared to darbepoetin alfa. The purpose of this study was to compare the patterns of use, efficiency of therapy and cost with undergoing hemodialysis patients. Electronic medical record system was used to examine administration frequency, hemoglobin response rate, achievement of target hemoglobin, drug costs. Administration frequency was once in 4 weeks with methoxy polyethylene glycol epoetin beta group and 3 times in 4 weeks with darbepoetin alfa group. Hemoglobin response rate was 61.5% in methoxy polyethylene glycol epoetin beta at the time of 16 weeks. It was not significantly different from 66.7% in darbepoetin alfa (P = 1.000). The drug cost for methoxy polyethylene glycol epoetin beta group was little higher than darbepoetin alfa group. However, there was no statistically significant difference (P = 0.164). Use of methoxy polyethylene glycol epoetin beta is as effective and safe as darbepoetin alfa managing renal anemia in hemodialysis patients. Methoxy polyethylene glycol epoetin beta's extended administration interval improve patient's compliance and enable effective anemia treatment. 展开更多
关键词 Methoxy polyethylene glycol epoetin beta erythropoiesis stimulating agent renal anemia hemoglobin.
下载PDF
Bisacodyl plus split 2-L polyethylene glycol-citrate-simethicone improves quality of bowel preparation before screening colonoscopy 被引量:10
11
作者 Flavio Valiante Angelo Bellumat +1 位作者 Manuela De Bona Michele De Boni 《World Journal of Gastroenterology》 SCIE CAS 2013年第33期5493-5499,共7页
AIM:To compare the bowel cleansing efficacy,tolerability and acceptability of split 2-L polyethylene glycol(PEG)-citrate-simethicone(PEG-CS)plus bisacodyl(BIS)vs 4-L PEG for fecal occult blood test-positive screening ... AIM:To compare the bowel cleansing efficacy,tolerability and acceptability of split 2-L polyethylene glycol(PEG)-citrate-simethicone(PEG-CS)plus bisacodyl(BIS)vs 4-L PEG for fecal occult blood test-positive screening colonoscopy.METHODS:This was a randomised,observer-blind comparative study.Two hundred and sixty-four subjects underwent screening colonoscopy(mean age 62.5±7.4years,male 61.7%).The primary objective of the study was to compare the bowel cleansing efficacy of the two preparations.Interventions:BIS plus PEG-CS:3 tablets of 5-mg BIS at 16:00,PEG-CS 1-L at 19:00 and 1-L at7:00,4-L PEG:3-L at 17:00,and 1-L at 7:00.Colonoscopy was carried out after 11:00,at least 3 h after the completion of bowel preparation.Bowel cleansing was evaluated using the Harefield Cleansing Scale.RESULTS:Bowel preparation was successful for 92.8%of subjects in the PEG-CS group and for 92.1%of subjects in the 4-L PEG(RR=1.01;95%CI:0.94-1.08).BIS+PEG-CS was better tolerated than 4-L PEG.A greater rate of patients in the BIS+PEG-CS group had no difficulty and/or were willing to repeat the same preparation compared to split-dose 4-L PEG group.Subjects in the BIS+PEG-CS group rated the prep as good or satisfactory in 90.6%as compared to 77%in the 4-L PEG(P=0.003).Subjects receiving BIS+PEGCS stated they fully adhered to instructions drinking all the 2-L solution in 97.1%compared with 87.3%in the4-L PEG(P=0.003).CONCLUSION:BIS plus split 2-L PEG-CS was as effective as but better tolerated and accepted than split4-L PEG for screening colonoscopy.This new procedure may increase the positive attitude and participation to colorectal cancer screening colonoscopy. 展开更多
关键词 COLONOSCOPY Colon CLEANSING Bowel preparations polyethylene glycol SIMETHICONE BISACODYL
下载PDF
Randomized controlled trial of sodium phosphate tablets vs polyethylene glycol solution for colonoscopy bowel cleansing 被引量:10
12
作者 Yoon Suk Jung Chang Kyun Lee +3 位作者 Hyo Jong Kim Chang Soo Eun Dong Soo Han Dong Ⅱ Park 《World Journal of Gastroenterology》 SCIE CAS 2014年第42期15845-15851,共7页
AIM: To compare efficacy, patient compliance, acceptability, satisfaction, safety, and adenoma detection rate of sodium phosphate tablets (NaP, CLICOLON<sup>TM</sup>) to a standard 4 L polyethylene glycol ... AIM: To compare efficacy, patient compliance, acceptability, satisfaction, safety, and adenoma detection rate of sodium phosphate tablets (NaP, CLICOLON<sup>TM</sup>) to a standard 4 L polyethylene glycol (PEG) solution for bowel cleansing for adults undergoing colonoscopy. 展开更多
关键词 Sodium phosphate tablets polyethylene glycol COLONOSCOPY Bowel preparation
下载PDF
Lubiprostone used with polyethylene glycol in diabetic patients enhances colonoscopy preparation quality 被引量:6
13
作者 Erika Grigg Moonkyung C Schubert +4 位作者 Joshua Hall Fadi Rahhal Dimple Raina Subbaramiah Sridhar Sherman M Chamberlain 《World Journal of Gastrointestinal Endoscopy》 CAS 2010年第7期263-267,共5页
AIM: To assess the additive effect of lubiprostone on the quality of colon preparation in diabetics given single-dosed polyethylene glycol electrolyte(PEG)for colonoscopy.METHODS:This was an investigator-initiated,sin... AIM: To assess the additive effect of lubiprostone on the quality of colon preparation in diabetics given single-dosed polyethylene glycol electrolyte(PEG)for colonoscopy.METHODS:This was an investigator-initiated,singlecenter,single-blinded prospective trial comparing the efficacy of L+PEG to PEG alone on colon preparation quality in diabetics undergoing screening colonoscopy.The study was approved by our institution’s IRB.The PEG was given as a single-dose to address patientcompliance concerns voiced by our IRB with splitdosing.All patients received only clear liquids the day prior to colonoscopy.Experimental group(Grp L)received PEG+1 dose L 2 h prior to and 2 h after PEG completion.Control group(Grp C)received only PEG the evening prior to the colonoscopy.Patients were randomly assigned to one of the 2 groups.The endoscopist was blinded to which colon prep was given and all colonoscopies were complete.Upon colonoscopy completion,the endoscopist rated the colon prep-quality by a validated 5-point Likert scale(1-excellent to 5-inadequate).RESULTS:Sixty patients were enrolled in the study;30 Grp L and 30 Grp C.Overall,patients were excluded due to study non-completion in 12(41%)Grp L and 5(17%) Grp C,P=0.04.Average colon preparation score Grp L =2.47 and Grp C=3.00,P=0.09.Although this was not statistically significant,there was a trend towards improved colon prep in Grp L.Statistical significance may have been achieved if completion rates had been similar between both study groups.CONCLUSION:Use of 2-L capsules with PEG resulted in a trend towards improved colon prep over PEG alone in diabetic patients when given as a single-dose regimen. 展开更多
关键词 LUBIPROSTONE polyethylene glycol Diabetes COLONOSCOPY COLON PREPARATION
下载PDF
Conundrums and confusions regarding how polyethylene glycol-fusion produces excellent behavioral recovery after peripheral nerve injuries 被引量:4
14
作者 George D.Bittner Dale R.Sengelaub Cameron L.Ghergherehchi 《Neural Regeneration Research》 SCIE CAS CSCD 2018年第1期53-57,共5页
Current Neuroscience dogma holds that transections or ablations of a segment of peripheral nerves produce: (1) Immediate loss of axonal continuity, sensory signaling, and motor control; (2) Wallerian rapid (1-3 ... Current Neuroscience dogma holds that transections or ablations of a segment of peripheral nerves produce: (1) Immediate loss of axonal continuity, sensory signaling, and motor control; (2) Wallerian rapid (1-3 days) degeneration of severed distal axons, muscle atrophy, and poor behavioral recovery after many months (if ever, after ablations) by slowly-regenerating (1 mm/d), proximal-stump outgrowths that must specifically reinnervate denervated targets; (3) Poor acceptance of microsutured nerve allografts, even if tissue-matched and immune-suppressed. Repair of transections/ablations by neurorrhaphy and well-specified-sequences of PEG-fusion solutions (one containing polyethylene glycol, PEG) successfully address these problems. However, conundrums and confusions regarding unorthodox and dramatic results of PEG-fusion repair in animal model systems often lead to misunderstandings. For example, (1) Axonal continuity and signaling is re-established within minutes by non-specifically PEG-fusing (connecting) severed motor and sensory axons across each lesion site, but remarkable behavioral recovery to near-unoperated levels takes several weeks; (2) Many distal stumps of inappropriately-reconnected, PEG-fused axons do not ever (Wallerian) degenerate and continuously innervate muscle fibers that undergo much less atrophy than otherwise-denervated muscle fibers; (3) Host rats do not reject PEG-fused donor nerve allografts in a non-immuno-privileged environment with no tissue matching or immunosuppression; (4) PEG fuses apposed open axonal ends or seals each shut (thereby preventing PEG-fusion), depending on the experimental protocol; (5) PEG-fusion protocols produce similar results in animal model systems and early human case studies. Hence, iconoclastic PEG-fusion data appropriately understood might provoke a re-thinking of some Neuroscience dogma and a paradigm shift in clinical treatment of peripheral nerve injuries. 展开更多
关键词 axonal repair AXOTOMY Wallerian degeneration polyethylene glycol ALLOGRAFT AUTOGRAFT nerve regeneration
下载PDF
Effect of exogenous spastin combined with polyethylene glycol on sciatic nerve injury 被引量:5
15
作者 Yao-Fa Lin Zheng Xie +3 位作者 Jun Zhou Hui-Hao Chen Wan-Wan Shao Hao-Dong Lin 《Neural Regeneration Research》 SCIE CAS CSCD 2019年第7期1271-1279,共9页
Polyethylene glycol can connect the distal and proximal ends of an injured nerve at the cellular level through axonal fusion to avoid Wallerian degeneration of the injured distal nerve and promote peripheral nerve reg... Polyethylene glycol can connect the distal and proximal ends of an injured nerve at the cellular level through axonal fusion to avoid Wallerian degeneration of the injured distal nerve and promote peripheral nerve regeneration.However,this method can only prevent Wallerian degeneration in 10% of axons because the cytoskeleton is not repaired in a timely fashion.Reconstruction of the cytoskeletal trunk and microtubule network has been suggested to be the key for improving the efficiency of axonal fusion.As a microtubule-severing protein,spastin has been used to enhance cytoskeletal reconstruction.Therefore,we hypothesized that spastin combined with polyethylene glycol can more effectively promote peripheral nerve regeneration.A total of 120 male Sprague-Dawley rats were randomly divided into sham,suture,polyethylene glycol,and polyethylene glycol + spastin groups.In suture group rats,only traditional nerve anastomosis of the end-to-end suture was performed after transection of the sciatic nerve.In polyethylene glycol and polyethylene glycol + spastin groups,50 μL of polyethylene glycol or 25 μL of polyethylene glycol + 25 μL of spastin,respectively,were injected immediately under the epineurium of the distal suture.Sensory fiber regeneration distance,which was used to assess early nerve regeneration at 1 week after surgery,was shortest in the suture group,followed by polyethylene glycol group and greatest in the polyethylene glycol + spastin group.Behavioral assessment of motor function recovery in rats showed that limb function was restored in polyethylene glycol and polyethylene glycol + spastin groups at 8 weeks after surgery.At 1,2,4 and 8 weeks after surgery,sciatic functional index values and percentages of gastrocnemius muscle wet weight were highest in the sham group,followed by polyethylene glycol + spastin and polyethylene glycol groups,and lowest in the suture group.Masson staining was utilized to assess the morphology of muscle tissue.Morphological changes in skeletal muscle were detectable in suture,polyethylene glycol,and polyethylene glycol + spastin groups at 1,2,4,and 8 weeks after surgery.Among them,muscular atrophy of the suture group was most serious,followed by polyethylene glycol and polyethylene glycol + spastin groups.Ultrastructure of distal sciatic nerve tissue,as detected by transmission electron microscopy,showed a pattern of initial destruction,subsequent disintegration,and gradual repair in suture,polyethylene glycol,and polyethylene glycol + spastin groups at 1,2,4,and8 weeks after surgery.As time proceeded,axonal ultrastructure gradually recovered.Indeed,the polyethylene glycol + spastin group was similar to the sham group at 8 weeks after surgery.Our findings indicate that the combination of polyethylene glycol and spastin can promote peripheral nerve regeneration.Moreover,the effect of this combination was better than that of polyethylene glycol alone,and both were superior to the traditional neurorrhaphy.This study was approved by the Animal Ethics Committee of the Second Military Medical University,China(approval No.CZ20170216) on March 16,2017. 展开更多
关键词 NERVE REGENERATION PERIPHERAL NERVES Wallerian degeneration polyethylene glycol axonal fusion SPASTIN PERIPHERAL NERVE injuries MASSON staining microtubule neural REGENERATION
下载PDF
Pilot study on efficacy of reduced cathartic bowel preparation with polyethylene glycol and bisacodyl 被引量:3
16
作者 Zhi-Yuan Chen He-Song Shen +6 位作者 Ming-Yue Luo Chai-Jie Duan Wen-Li Cai Hong-Bing Lu Guo-Peng Zhang Yang Liu Jerome Z Liang 《World Journal of Gastroenterology》 SCIE CAS 2013年第4期561-568,共8页
AIM:To evaluate the efficacy of reduced cathartic bowel preparation with 2 L polyethylene glycol(PEG)-4000 electrolyte solution and 10 mg bisacodyl enteric-coated tablets for computed tomographic colonography(CTC).MET... AIM:To evaluate the efficacy of reduced cathartic bowel preparation with 2 L polyethylene glycol(PEG)-4000 electrolyte solution and 10 mg bisacodyl enteric-coated tablets for computed tomographic colonography(CTC).METHODS:Sixty subjects who gave informed consent were randomly assigned to study group A,study group B or the control group.On the day prior to CTC,subjects in study group A were given 20 mL 40% wt/vol barium sulfate suspension before 3 mealtimes,60 mL 60% diatrizoate meglumine diluted in 250 mL water after supper,and 10 mg bisacodyl enteric-coated tablets 1 h before oral administration of 2 L PEG-4000 electrolyte solution.Subjects in study group B were treated identically to those in study group A,with the exception of bisacodyl which was given 1 h after oral PEG-4000.Subjects in the control group were managed using the same strategy as the subjects in study group A,but without administration of bisacodyl.Residual stool and fluid scores,the attenuation value of residual fluid,and discomfort during bowel preparation in the three groups were analyzed statistically.RESULTS:The mean scores for residual stool and fluid in study group A were lower than those in study group B,but the differences were not statistically significant.Subjects in study group A showed greater stool and fluid cleansing ability than the subjects in study group B.The mean scores for residual stool and fluid in study groups A and B were lower than those in the control group,and were significantly different.There was no significant difference in the mean attenuation value of residual fluid between study group A,study group B and the control group.The total discomfort index during bowel preparation was 46,45 and 45 in the three groups,respectively,with no significant difference.CONCLUSION:Administration of 10 mg bisacodyl enteric-coated tablets prior to or after oral administration of 2 L PEG-4000 electrolyte solution enhances stool and fluid cleansing ability,and has no impact on the attenuation value of residual fluid or the discomfort index.The former is an excellent alternative for CTC colorectum 展开更多
关键词 COLORECTAL cancer Screening COMPUTED tomographic COLONOGRAPHY polyethylene glycol BISACODYL
下载PDF
Efficacy of 1.2L polyethylene glycol plus ascorbic acid for bowel preparations 被引量:4
17
作者 Hiroyuki Tamaki Teruyo Noda +5 位作者 Masahiro Morita Akina Omura Atsushi Kubo Chikara Ogawa Toshihiro Matsunaka Mitsushige Shibatoge 《World Journal of Clinical Cases》 SCIE 2019年第4期452-465,共14页
BACKGROUND A low-volume polyethylene glycol(PEG) solution that combines ascorbic acid with PEG-based electrolyte solution(PEG-ASC) is gaining mainstream acceptance for bowel preparation due to reduced volume and impro... BACKGROUND A low-volume polyethylene glycol(PEG) solution that combines ascorbic acid with PEG-based electrolyte solution(PEG-ASC) is gaining mainstream acceptance for bowel preparation due to reduced volume and improved taste.Although several reports showed that bowel preparation with PEG-ASC volume lower than 2.0 L with laxative agents could be an alternative to traditional preparation regimen, the cleansing protocols have not been fully investigated.AIM To evaluate the cleansing efficacy of 1.2 L PEG-ASC solution comparing with 2.0 L PEG electrolyte(PEG-ELS) for bowel preparations.METHODS A randomized, single-blinded, open-label, single-center, non-inferiority study was conducted. In total, 312 Japanese adult patients(aged > 18 years) who underwent colonoscopy were enrolled. Patients were randomly allocated to bowel lavage with either 1.2 L of PEG-ASC solution with at least 0.6 L of an additional clear fluid(1.2 L PEG-ASC group) or 2.0 L of PEG-ELS(PEG-ELS group). Then, 48 mg of sennoside was administered at bedtime on the day before colonoscopy, and the designated drug solution was administered at the hospital on the day of colonoscopy. Bowel cleansing was evaluated using the Boston Bowel Preparation Scale(BBPS). The volume of fluid intake and required time for bowel preparation were evaluated. Furthermore, compliance, patient tolerance,and overall acceptability were evaluated using a patient questionnaire, which was assessed using a visual analog scale.RESULTS In total, 291 patients(1.2 L PEG-ASC group, 148; PEG-ELS group, 143) completed the study. There was no significant difference in successful cleansing, defined as a BBPS score ≥ 2 in each segment, between the two groups(1.2 L PEG-ASC group, 91.9%; PEG-ELS group, 90.2%; 95%CI:-0.03-0.09). The required time for bowel preparation was significantly shorter(164.95 min ± 68.95 min vs 202.16 min± 68.69 min, P < 0.001) and the total fluid intake volume was significantly lower(2.23 L ± 0.55 L vs 2.47 L ± 0.56 L, P < 0.001) in the 1.2 L PEG-ASC group than in the PEG-ELS group. Palatability, acceptability of the volume of solution, and overall acceptability evaluated using a patient questionnaire, which was assessed by the visual analog scale, were significantly better in the 1.2 L PEG-ASC group than in the PEG-ELS group(7.70 cm ± 2.57 cm vs 5.80 cm ± 3.24 cm, P < 0.001). No severe adverse event was observed in each group.CONCLUSION The 1.2 L PEG-ASC solution was non-inferior to the 2.0 L PEG-ELS solution in terms of cleansing efficacy and had better acceptability among Japanese patients. 展开更多
关键词 Ascorbic acid BOWEL preparation COLONOSCOPY EFFICACY polyethylene glycol TOLERABILITY
下载PDF
Synthesis and Characterization of Carboxyl-terminated Polyethylene Glycol Functionalized Mesoporous Silica Nanoparticles 被引量:3
18
作者 WANG Yu LIU Mingxing 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2018年第6期1540-1545,共6页
Colloidal mesoporous silica nanoparticles functionalized with carboxy-terminated polyethylene glycol(CMS-PEG-COOH) were successfully synthesized by covalently grafting dicarboxy-terminated polyethylene glycol(HOOC-PEG... Colloidal mesoporous silica nanoparticles functionalized with carboxy-terminated polyethylene glycol(CMS-PEG-COOH) were successfully synthesized by covalently grafting dicarboxy-terminated polyethylene glycol(HOOC-PEG-COOH) on the surface of the amino functionalized CMS nanoparticles with amide bond as a cross linker. Moreover, the structural and particle properties of CMS-PEG-COOH were characterized by nuclear magnetic resonance spectroscopy(1 H-NMR), transmission electron microscopy(TEM), dynamic light scattering(DLS), nitrogen adsorption-desorption measurements, X-ray diffraction(XRD), and Fourier transform infrared spectroscopy(FT-IR). The nanomaterials presented a relatively uniform spherical shape morphology with diameters of about 120 nm,and favorable dispersibility in weak acid solution. The CMSPEG-COOH exhibited no changes in the state of amorphous, while the mesopores sizes of 5.25 nm might provide the nanomaterials with large capacity for the loading and releasing of drugs. So the results indicated that CMSPEG-COOH might be a critical nanomaterial for drug delivery system in the future. 展开更多
关键词 mesoporous silica nanoparticles polyethylene glycol FUNCTIONALIZATION carboxy-terminated synthesis
下载PDF
Prospective controlled study on the effects of polyethylene glycol in capsule endoscopy 被引量:7
19
作者 Takafumi Ito Ken Ohata +4 位作者 Akiko Ono Hideyuki Chiba Yosuke Tsuji Hajime Sato Nobuyuki Matsuhashi 《World Journal of Gastroenterology》 SCIE CAS CSCD 2012年第15期1789-1792,共4页
AIM:To prospectively confirm whether a small amount of polyethylene glycol(PEG)ingested after swallowing endoscopy capsule improves image quality and completion rate.METHODS:Forty-four consecutive patients referred to... AIM:To prospectively confirm whether a small amount of polyethylene glycol(PEG)ingested after swallowing endoscopy capsule improves image quality and completion rate.METHODS:Forty-four consecutive patients referred to us for capsule endoscopy(CE)were randomized to two groups.All patients were restricted to clear fluids for 12 h before the examination.Patients in group A(22 cases)received no additional preparation,while those in group B(20 cases)ingested 500 mL of PEG within a 2 h period starting 30 min after swallowing the capsule.Clear fluids and meals were allowed 2 h and 4 h after capsule ingestion,respectively.Image quality was assessed as the percentage of visualized bowel surface area as follows:1:<25%;2:25%-49%;3:50%-74%;4:75%-89%;5:>90%.The small bowel record was divided into five segments by time,and the score for each segment was evaluated.All CE examinations were performed with the Pillcam SB capsule endoscopy sys-tem(Given Imaging Co.Ltd.,Yoqnem).RESULTS:This study ended in December 2009,because sample size was considered large enough.A total of 44 patients were enrolled.Two patients in group B were excluded from the analysis because small bowel images could not be obtained from these patients;one had a full stomach,while the other presented with a massive gastric bleed.Thus,22 patients from group A and 20 patients from group B completed the study.There was no significant difference in age(P=0.22),sex(P=0.31),and indication for CE.No significant adverse events occurred in any of the study patients.In group A,image quality deteriorated as the capsule progressed distally.However,in group B,image quality was maintained to the distal small bowel.In each of the five segments,the visibility score was significantly higher in group B than in group A(segment 1:4.3± 0.7vs 4.7±0.5,P=0.03;segment 2:4.2±0.9vs 4.8 ±0.4,P=0.01;segment 3:4.0±1.0 vs 4.6±0.7,P =0.04;segment 4:3.6±1.1 vs 4.5±0.6,P=0.003;segment 5:2.7±1.0vs 4.4±0.8,P=0.00004).Thus,the use of PEG during CE examination significantly improved image quality in all time segments,and this effect was more pronounced in the distal ileum.The completion rate to the cecum was not significantly different between groups A and B(81.8%vs 85.0%,P =0.89).There was no difference in the gastric transit time between groups(36.2±35.0 min vs 54.0±56.6 min,P=0.23),but the small bowel transit time was significantly longer in group A than in group B(246.0± 107.0 minvs 171.0±104.0 min,P=0.04).CONCLUSION:The ingestion of a small amount of PEG after the swallowing of an endoscopy capsule significantly improved CE image quality,but did not enhance the completion rate to the cecum. 展开更多
关键词 Capsule endoscopy Completion rate Image quality polyethylene glycol PREPARATION
下载PDF
Preparation and Hydrophilicity of Copolymerization of Chitosan Selectively Grafted by Polyethylene Glycol 被引量:3
20
作者 李若慧 SHAN Dantong DU Ying 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2013年第2期334-338,共5页
Copolymerization of chitosan selectively grafted by polyethylene glycol was prepared. Chitosan was selectively grafted by monomethoxy polyethylene glycol(mPEG-OH), which contained a hydroxyl group combining with hex... Copolymerization of chitosan selectively grafted by polyethylene glycol was prepared. Chitosan was selectively grafted by monomethoxy polyethylene glycol(mPEG-OH), which contained a hydroxyl group combining with hexamethylene diisocyanate(HDI) to form a novel macromonomer namely monomethoxy polyethylene glycol isocyanate(mPEG-NCO) containing a isocyanate group with higher chemical activity in ethyl glyoxalate solution absolutely without water. The selective grafted copolymerization of Chitosan with mPEG-NCO was conducted under heterogeneous conditions as suspension in dimethylformamide. The hydrophilic copolymers of chitosan were prepared by condensation reaction of isocyanate group on mPEG- NCO with hydroxy groups on chitosan chains because amino groups on chitosan chains were protected by complexion formation with copper ions. The effect of reaction condition on the grafting extents was discussed. Swelling properties of mPEG-g-CS were researched. The graft copolymer mPEG-g-CS was characterized by the infrared spectra. The experimental result showed that the copper ions were very effective to protect amino groups from condensation reaction. The swelling degree in water increases with adding of grafting ratio. The maximum swelling degree was up to above 132% when the grafting ratio was about 270%. The graft copolymer can be soluble partially in pure water. 展开更多
关键词 CHITOSAN polyethylene glycol selectively graft grafting ratio HYDROPHILICITY swelling properties
下载PDF
上一页 1 2 219 下一页 到第
使用帮助 返回顶部