In this paper, Black Box approach is presented for behavioral modeling of a non linear power amplifier with memory effects. Large signal parameters of a Motorola LDMOS power amplifier driven by a WCDMA signal were ext...In this paper, Black Box approach is presented for behavioral modeling of a non linear power amplifier with memory effects. Large signal parameters of a Motorola LDMOS power amplifier driven by a WCDMA signal were extracted while taking into considerations the power amplifier’s bandwidth. The proposed model was validated based on the simulated data. Some validation results are presented both in the time and frequency domains, using WCDMA signal.展开更多
The energizing of large power transformers has long been considered a critical event in the operation of an electric power system. When a transformer is energized by the utility, a typical inrush current could be as h...The energizing of large power transformers has long been considered a critical event in the operation of an electric power system. When a transformer is energized by the utility, a typical inrush current could be as high as ten times its rated current. This could cause many problems from mechanical stress on transformer windings to harmonics injection, and system protection malfunction. There have been numerous researches focusing on calculation and mitigation of the transformer inrush current. With the development of smart grid, distributed generation from independent power producers (IPPs) is growing rapidly. This paper investigates the inrush current due to black start of an IPP system with several parallel transformers, through a simulation model in DIgSILENT Power Factory software. The study demonstrates that a single genset is capable of energizing a group of transformers since the overall inrush current is slightly above the inrush of the transformer directly connected to the generator. In addition, a simple method is proposed to mitigate the inrush current of the transformers using an auxiliary transformer.展开更多
文摘In this paper, Black Box approach is presented for behavioral modeling of a non linear power amplifier with memory effects. Large signal parameters of a Motorola LDMOS power amplifier driven by a WCDMA signal were extracted while taking into considerations the power amplifier’s bandwidth. The proposed model was validated based on the simulated data. Some validation results are presented both in the time and frequency domains, using WCDMA signal.
文摘The energizing of large power transformers has long been considered a critical event in the operation of an electric power system. When a transformer is energized by the utility, a typical inrush current could be as high as ten times its rated current. This could cause many problems from mechanical stress on transformer windings to harmonics injection, and system protection malfunction. There have been numerous researches focusing on calculation and mitigation of the transformer inrush current. With the development of smart grid, distributed generation from independent power producers (IPPs) is growing rapidly. This paper investigates the inrush current due to black start of an IPP system with several parallel transformers, through a simulation model in DIgSILENT Power Factory software. The study demonstrates that a single genset is capable of energizing a group of transformers since the overall inrush current is slightly above the inrush of the transformer directly connected to the generator. In addition, a simple method is proposed to mitigate the inrush current of the transformers using an auxiliary transformer.