To study the seismic performance of double-skin steelconcrete composite box( DSCB) piers, a total of 11 DSCB pier specimens were tested under bidirectional cyclic loading. The effects of the loading pattern, the ste...To study the seismic performance of double-skin steelconcrete composite box( DSCB) piers, a total of 11 DSCB pier specimens were tested under bidirectional cyclic loading. The effects of the loading pattern, the steel plate thickness, the axial load ratio, the slenderness ratio and the aspect ratio were taken into consideration. The damage evolution process and failure modes of the tested specimens are presented in detail. Test results are also discussed in terms of the hysteretic curve, skeleton curve, ductility and energy dissipation capacity of DSCB pier specimens. It can be concluded that the hysteretic performance of DSCB piers in one direction is affected and weakened by the cyclic loading in the other direction. DSCB piers under bidirectional cyclic loading exhibit good performance in terms of load carrying capacity, ductility, and energy dissipation capacity. Overall, DSCB piers can meet the basic aseismic requirements. The research results can be taken as a reference for using DSCB piers as high piers in bridges in strong earthquakeprone areas.展开更多
To study the anti-explosion protection effect of polyurea coating on reinforced concrete box girder,two segmental girder specimens were made at a scale of 1:3,numbered as G(without polyurea coating)and PCG(with polyur...To study the anti-explosion protection effect of polyurea coating on reinforced concrete box girder,two segmental girder specimens were made at a scale of 1:3,numbered as G(without polyurea coating)and PCG(with polyurea coating).The failure characteristics and dynamic responses of the specimens were compared through conducting explosion tests.The reliability of the numerical simulation using LS-DYNA software was verified by the test results.The effects of different scaled distances,reinforcement ratios,concrete strengths,coating thicknesses and ranges of polyurea were studied.The results show that the polyurea coating can effectively enhance the anti-explosion performance of the girder.The top plate of middle chamber in specimen G forms an elliptical penetrating hole,while that in specimen PCG only shows a very slight local dent.The peak vertical displacement and residual displacement of PCG decrease by 74.8% and 73.7%,respectively,compared with those of specimen G.For the TNT explosion with small equivalent,the polyurea coating has a more significant protective effect on reducing the size of fracture.With the increase of TNT equivalent,the protective effect of polyurea on reducing girder displacement becomes more significant.The optimal reinforcement ratio,concrete strength,thickness and range of polyurea coating were also drawn.展开更多
To obtain the vertical earth pressure on a soft foundation box culvert and investigate the interaction of the soil-culvert-foundation system, both a centrifugal model test and a numerical simulation were conducted and...To obtain the vertical earth pressure on a soft foundation box culvert and investigate the interaction of the soil-culvert-foundation system, both a centrifugal model test and a numerical simulation were conducted and the comparisons with the current methods to determine the load on a culvert were completed. The results of the model test and numerical analysis are in satisfactory agreement, which shows that the direction of the shear stress between the culvert and the adjacent embankment depends on the differential settlement between them. A vertical earth pressure concentration appears on the culvert with a rigid piles foundation because of a downward shear stress. The ratio of the load on a soft foundation culvert and the overburden pressure above the culvert raises first and then decreases as the backfill height increases. In order to reduce the load on a culvert, it is suggested to limit the stiffness difference of the foundations under the culvert and embankment and to use a light backfill over the culvert.展开更多
Background: The Box and Block clinical test is a validated and standardized scale for use in the clinical environment that allows the assessment of rough manipulative dexterity. Proposing virtual methods to carry out ...Background: The Box and Block clinical test is a validated and standardized scale for use in the clinical environment that allows the assessment of rough manipulative dexterity. Proposing virtual methods to carry out these assessments is an attempt to eliminate some of the subjectivity that the test may entail depending on the observer and the way in which the patient gives instructions. Applied to the assessment of skills after neurological pathologies, previous experiences in stroke patients have been found. So, this work was centered on the Spinal Cord Injury. Objective: To present the virtual application of the Box and Block scale, as well as details about its design and development for its manipulation based on Leap Motion Controller. Methodology: The relationship between the results obtained in the actual test and in the virtual application in healthy subjects and, mostly, patients with cervical spinal cord injury is analyzed, obtaining a high correlation index between both tests’ performance. Results: A high correlation index was obtained between both tests performance, the real and virtual version of the Box and Block Test. Conclusion: This virtual test can serve as an element to evaluate in the future the effectiveness of the RehabHand prototype based on virtual reality applications with a therapeutic and a rehabilitative sense that, manipulated from Leap Motion Controller, allow the improvement of the manipulative dexterity in patients with neurological diseases such as spinal cord injury.展开更多
Full-scale model tests were carried out on a 30 m span prestressed concrete box girder and a 20 m span prestressed concrete hollow slab. Failure models were prestressed reinforcement tensile failure and crashing of ro...Full-scale model tests were carried out on a 30 m span prestressed concrete box girder and a 20 m span prestressed concrete hollow slab. Failure models were prestressed reinforcement tensile failure and crashing of roof concrete, respectively. The ductility indexes of the box girder and hollow slab were 1.99 and 1.23, respectively, according to the energy viewpoint. Based on the horizontal section hypothesis, the nonlinear computation procedure was established using the limited banding law, and it could carry out the entire performance analysis including the unloading, mainly focusing on the ways to achieve the unloading curves computation through stress-strain, moment-curvature and load-displacement curves. Through the procedure, parameters that influence on the bearing capacity, deformation performance and ductility of the structures were analyzed. Those parameters were quantity of prestressed reinforcement and tension coefficients of prestressed reinforcement. From the analysis, some useful conclusions can be obtained.展开更多
A cable circuit of a substation in the United Kingdom showed high level of PD activities during a survey using hand hold PD testing equipment. The authors were invited to carry out on-site PD testing experiment to fur...A cable circuit of a substation in the United Kingdom showed high level of PD activities during a survey using hand hold PD testing equipment. The authors were invited to carry out on-site PD testing experiment to further diagnose and locate the potential problem of the cable system. This paper presents the experience of the present authors carrying out the cable test. Following a brief introduction to the experiment equipments and physical connections, the paper analyses the data collected from the testing, including PD pulse shape analysis, frequency spectrum analysis and phase resolved PD pattern analysis. Associated with PD propagation direction identification, PD source diagnosis and localisation was made. Four different types of sensors, which were adapted during the testing, are shown to have different frequency bandwidths and performed differently. Aider comparing the parameters of the sensor and the PD signals detected by individual sensor, optimal PD monitoring bandwidth for cable system is suggested.展开更多
Direct shear test is one of the simplest and most economical tests to measure shear strength parameters of dry or saturated sandy soil as well as soil-geogrid interaction parameters.In the current study the effects of...Direct shear test is one of the simplest and most economical tests to measure shear strength parameters of dry or saturated sandy soil as well as soil-geogrid interaction parameters.In the current study the effects of specimen size and density on soil-geogrid interaction parameters employing shear boxes of 6×6 cm,10×10 cm and 30×30 cm have been investigated.Results show that increasing specimen size of unreinforced sand with constant density results in a decrease in angle of friction which has been attributed to reduced confinement effect using larger shear boxes.The rate of reduction in angle of friction is increased by increasing soil density and using geogrid as reinforcement.展开更多
The article takes a simply supported prestressed concrete small box girder bridge project as an example for inspection and evaluation after a fire incident.This includes appearance detection,concrete color hardness de...The article takes a simply supported prestressed concrete small box girder bridge project as an example for inspection and evaluation after a fire incident.This includes appearance detection,concrete color hardness detection,concrete strength detection,concrete surface damage layer detection,reinforcement protective layer detection,and concrete carbonation detection.It is hoped that this analysis can be used as a reference for the detection and evaluation of future bridge projects with fire incidents to smoothen its subsequent repair and maintenance.展开更多
In this paper, by means of effective testing practices, main strategies of integration testing for GUI software, including differentiating strategy for distinguished system, strategy of personnel organization, increme...In this paper, by means of effective testing practices, main strategies of integration testing for GUI software, including differentiating strategy for distinguished system, strategy of personnel organization, incremental testing strategy based on baseline version, testing strategy of circulating loop through the whole life, and the strategy of test suite construction, were briefly investigated. Moreover, for the code analysis, the FTA (Fault Tree analysis) is proposed to deal with the software change in regression testing. For test suite constructing, the constructing methods for baseline version and the incremental change are deeply discussed, in which main points focus on the testing strategy based on “Sheet/Form”, the “Grey-box approach” for integration testing process, and the application of the improved STD (State Transform Diagram) in state testing. At the same time, the suite construction of integration testing for two types, including small scale program and large scale software, is analyzed and discussed in detail. For testing execution, the specific method based on “Cross-testing” is investigated. Concurrently, by a lot of examples, all results of testing activity indicate that these strategies and methods are useful and fitted to integration testing for GUI software.展开更多
In this paper, the test suite construction for GUI (Graphical User Interface) software may be executed centered on grey-box approach with the prior test design of window access controls for unit testing, including fro...In this paper, the test suite construction for GUI (Graphical User Interface) software may be executed centered on grey-box approach with the prior test design of window access controls for unit testing, including front-end method of white box and follow-up black box method for integration testing. Moreover, two key opinions are proposed for the test suite construction for GUI software, the first one is that the “Triple-step method” should be used for unit testing with the prior disposing of data boundary value testing of input controls, and another one is that the “Grey-box approach” should be applied in integration testing for GUI software with necessary testing preparation in the precondition. At the same time, the testing of baseline version and the incremental testing should be considered for the test case construction to coordinate with the whole evolution of software product today. Additionally, all our opinion and thought are verified and tested with a typical case of GUI software—PQMS (Product Quality Monitoring Software/System), and results indicate that these methods and specific disposing are practical and effective.展开更多
In order to analyze the load carrying capacity of prestressed concrete box girders, failure behaviors of in-situ deteriorated continuous prestressed concrete box girders under loading are experimentally observed and a...In order to analyze the load carrying capacity of prestressed concrete box girders, failure behaviors of in-situ deteriorated continuous prestressed concrete box girders under loading are experimentally observed and a finite failure analysis method for predicting behaviors of box girders is developed. A degenerated solid shell element is used to simulate box girders and material nonlinearity is considered. Since pre-stressed concrete box girders usually have a large number of curve prestressed tendons, a type of combined element is presented to simulate the prestressed tendons of box girders, and then the number of elements can be significantly reduced. The analytical results are compared with full-scale failure test results. The comparison shows that the presented method can be effectively applied to the failure analysis of in-situ continuous prestressed concrete box girders, and it also shows that the studied old bridge still has enough load carrying capacity.展开更多
[Objective] Taking the characteristic of flower diameter of Tagetes L.as an example,this study aimed to select example varieties used in the DUS Test Guideline of Tagetes L.[Method] Two continuous years of measurement...[Objective] Taking the characteristic of flower diameter of Tagetes L.as an example,this study aimed to select example varieties used in the DUS Test Guideline of Tagetes L.[Method] Two continuous years of measurements of flower diameter of 25 varieties were collected and then analyzed by using the box plot to illustrate the uniformity and stability of flower diameter of each variety.[Result] According to the information of variability,distribution symmetry of measurements and outliers of flower diameter of varieties provided by box plots,variety 16,2 and 4 were selected as the example varieties for the three expression states with respective flower diameter of 3.0-4.4,6.0-7.4 and 9.0-10.4 cm.[Conclusion] The box plot is an efficient method for the general analysis of varieties,which provides information covering the actual and possible expression range,median and outliers of measurements of flower diameter of each variety.It also provides references for selecting example varieties for other quantitative characteristics and evaluating the quality of varieties.展开更多
基金The National Natural Science Foundation of China(No.5117810151378112)the Doctoral Fund of Ministry of Education(No.20110092110011)
文摘To study the seismic performance of double-skin steelconcrete composite box( DSCB) piers, a total of 11 DSCB pier specimens were tested under bidirectional cyclic loading. The effects of the loading pattern, the steel plate thickness, the axial load ratio, the slenderness ratio and the aspect ratio were taken into consideration. The damage evolution process and failure modes of the tested specimens are presented in detail. Test results are also discussed in terms of the hysteretic curve, skeleton curve, ductility and energy dissipation capacity of DSCB pier specimens. It can be concluded that the hysteretic performance of DSCB piers in one direction is affected and weakened by the cyclic loading in the other direction. DSCB piers under bidirectional cyclic loading exhibit good performance in terms of load carrying capacity, ductility, and energy dissipation capacity. Overall, DSCB piers can meet the basic aseismic requirements. The research results can be taken as a reference for using DSCB piers as high piers in bridges in strong earthquakeprone areas.
基金the Natural Science Foundation of Jiangsu Province(Grant No.BK20200494)China Postdoctoral Science Foundation(Grant No.2021M701725)+3 种基金Jiangsu Postdoctoral Research Funding Program(Grant No.2021K522C)Fundamental Research Funds for the Central Universities(Grant No.30919011246)National Natural Science Foundation of China(Grant No.52278188)Natural Science Foundation of Jiangsu Province(Grant No.BK20211196)。
文摘To study the anti-explosion protection effect of polyurea coating on reinforced concrete box girder,two segmental girder specimens were made at a scale of 1:3,numbered as G(without polyurea coating)and PCG(with polyurea coating).The failure characteristics and dynamic responses of the specimens were compared through conducting explosion tests.The reliability of the numerical simulation using LS-DYNA software was verified by the test results.The effects of different scaled distances,reinforcement ratios,concrete strengths,coating thicknesses and ranges of polyurea were studied.The results show that the polyurea coating can effectively enhance the anti-explosion performance of the girder.The top plate of middle chamber in specimen G forms an elliptical penetrating hole,while that in specimen PCG only shows a very slight local dent.The peak vertical displacement and residual displacement of PCG decrease by 74.8% and 73.7%,respectively,compared with those of specimen G.For the TNT explosion with small equivalent,the polyurea coating has a more significant protective effect on reducing the size of fracture.With the increase of TNT equivalent,the protective effect of polyurea on reducing girder displacement becomes more significant.The optimal reinforcement ratio,concrete strength,thickness and range of polyurea coating were also drawn.
基金Project(2012AA112504) supported by the National High Technology Research and Development Program of ChinaProjects(51108048,51478054) supported by the National Natural Science Foundation of China
文摘To obtain the vertical earth pressure on a soft foundation box culvert and investigate the interaction of the soil-culvert-foundation system, both a centrifugal model test and a numerical simulation were conducted and the comparisons with the current methods to determine the load on a culvert were completed. The results of the model test and numerical analysis are in satisfactory agreement, which shows that the direction of the shear stress between the culvert and the adjacent embankment depends on the differential settlement between them. A vertical earth pressure concentration appears on the culvert with a rigid piles foundation because of a downward shear stress. The ratio of the load on a soft foundation culvert and the overburden pressure above the culvert raises first and then decreases as the backfill height increases. In order to reduce the load on a culvert, it is suggested to limit the stiffness difference of the foundations under the culvert and embankment and to use a light backfill over the culvert.
文摘Background: The Box and Block clinical test is a validated and standardized scale for use in the clinical environment that allows the assessment of rough manipulative dexterity. Proposing virtual methods to carry out these assessments is an attempt to eliminate some of the subjectivity that the test may entail depending on the observer and the way in which the patient gives instructions. Applied to the assessment of skills after neurological pathologies, previous experiences in stroke patients have been found. So, this work was centered on the Spinal Cord Injury. Objective: To present the virtual application of the Box and Block scale, as well as details about its design and development for its manipulation based on Leap Motion Controller. Methodology: The relationship between the results obtained in the actual test and in the virtual application in healthy subjects and, mostly, patients with cervical spinal cord injury is analyzed, obtaining a high correlation index between both tests’ performance. Results: A high correlation index was obtained between both tests performance, the real and virtual version of the Box and Block Test. Conclusion: This virtual test can serve as an element to evaluate in the future the effectiveness of the RehabHand prototype based on virtual reality applications with a therapeutic and a rehabilitative sense that, manipulated from Leap Motion Controller, allow the improvement of the manipulative dexterity in patients with neurological diseases such as spinal cord injury.
基金National Natural Science Foundation of China(No.50678063)
文摘Full-scale model tests were carried out on a 30 m span prestressed concrete box girder and a 20 m span prestressed concrete hollow slab. Failure models were prestressed reinforcement tensile failure and crashing of roof concrete, respectively. The ductility indexes of the box girder and hollow slab were 1.99 and 1.23, respectively, according to the energy viewpoint. Based on the horizontal section hypothesis, the nonlinear computation procedure was established using the limited banding law, and it could carry out the entire performance analysis including the unloading, mainly focusing on the ways to achieve the unloading curves computation through stress-strain, moment-curvature and load-displacement curves. Through the procedure, parameters that influence on the bearing capacity, deformation performance and ductility of the structures were analyzed. Those parameters were quantity of prestressed reinforcement and tension coefficients of prestressed reinforcement. From the analysis, some useful conclusions can be obtained.
文摘A cable circuit of a substation in the United Kingdom showed high level of PD activities during a survey using hand hold PD testing equipment. The authors were invited to carry out on-site PD testing experiment to further diagnose and locate the potential problem of the cable system. This paper presents the experience of the present authors carrying out the cable test. Following a brief introduction to the experiment equipments and physical connections, the paper analyses the data collected from the testing, including PD pulse shape analysis, frequency spectrum analysis and phase resolved PD pattern analysis. Associated with PD propagation direction identification, PD source diagnosis and localisation was made. Four different types of sensors, which were adapted during the testing, are shown to have different frequency bandwidths and performed differently. Aider comparing the parameters of the sensor and the PD signals detected by individual sensor, optimal PD monitoring bandwidth for cable system is suggested.
基金The kind co-operation and financial support provided by Islamic Azad University-Pardis Branch and K.N.Toosi University of Technology(Faculty of Civil Engineering)is gratefully appreciated.
文摘Direct shear test is one of the simplest and most economical tests to measure shear strength parameters of dry or saturated sandy soil as well as soil-geogrid interaction parameters.In the current study the effects of specimen size and density on soil-geogrid interaction parameters employing shear boxes of 6×6 cm,10×10 cm and 30×30 cm have been investigated.Results show that increasing specimen size of unreinforced sand with constant density results in a decrease in angle of friction which has been attributed to reduced confinement effect using larger shear boxes.The rate of reduction in angle of friction is increased by increasing soil density and using geogrid as reinforcement.
文摘The article takes a simply supported prestressed concrete small box girder bridge project as an example for inspection and evaluation after a fire incident.This includes appearance detection,concrete color hardness detection,concrete strength detection,concrete surface damage layer detection,reinforcement protective layer detection,and concrete carbonation detection.It is hoped that this analysis can be used as a reference for the detection and evaluation of future bridge projects with fire incidents to smoothen its subsequent repair and maintenance.
文摘In this paper, by means of effective testing practices, main strategies of integration testing for GUI software, including differentiating strategy for distinguished system, strategy of personnel organization, incremental testing strategy based on baseline version, testing strategy of circulating loop through the whole life, and the strategy of test suite construction, were briefly investigated. Moreover, for the code analysis, the FTA (Fault Tree analysis) is proposed to deal with the software change in regression testing. For test suite constructing, the constructing methods for baseline version and the incremental change are deeply discussed, in which main points focus on the testing strategy based on “Sheet/Form”, the “Grey-box approach” for integration testing process, and the application of the improved STD (State Transform Diagram) in state testing. At the same time, the suite construction of integration testing for two types, including small scale program and large scale software, is analyzed and discussed in detail. For testing execution, the specific method based on “Cross-testing” is investigated. Concurrently, by a lot of examples, all results of testing activity indicate that these strategies and methods are useful and fitted to integration testing for GUI software.
文摘In this paper, the test suite construction for GUI (Graphical User Interface) software may be executed centered on grey-box approach with the prior test design of window access controls for unit testing, including front-end method of white box and follow-up black box method for integration testing. Moreover, two key opinions are proposed for the test suite construction for GUI software, the first one is that the “Triple-step method” should be used for unit testing with the prior disposing of data boundary value testing of input controls, and another one is that the “Grey-box approach” should be applied in integration testing for GUI software with necessary testing preparation in the precondition. At the same time, the testing of baseline version and the incremental testing should be considered for the test case construction to coordinate with the whole evolution of software product today. Additionally, all our opinion and thought are verified and tested with a typical case of GUI software—PQMS (Product Quality Monitoring Software/System), and results indicate that these methods and specific disposing are practical and effective.
基金Post-Doctoral Innovative Projects of Shandong Province(No.200703072)the National Natural Science Foundation of China(No.50574053)
文摘In order to analyze the load carrying capacity of prestressed concrete box girders, failure behaviors of in-situ deteriorated continuous prestressed concrete box girders under loading are experimentally observed and a finite failure analysis method for predicting behaviors of box girders is developed. A degenerated solid shell element is used to simulate box girders and material nonlinearity is considered. Since pre-stressed concrete box girders usually have a large number of curve prestressed tendons, a type of combined element is presented to simulate the prestressed tendons of box girders, and then the number of elements can be significantly reduced. The analytical results are compared with full-scale failure test results. The comparison shows that the presented method can be effectively applied to the failure analysis of in-situ continuous prestressed concrete box girders, and it also shows that the studied old bridge still has enough load carrying capacity.
基金Supported by the Special Fund for Agro-scientific Research in the Public Interest(200903008-14)the National "948" Project(2009-Z11)~~
文摘[Objective] Taking the characteristic of flower diameter of Tagetes L.as an example,this study aimed to select example varieties used in the DUS Test Guideline of Tagetes L.[Method] Two continuous years of measurements of flower diameter of 25 varieties were collected and then analyzed by using the box plot to illustrate the uniformity and stability of flower diameter of each variety.[Result] According to the information of variability,distribution symmetry of measurements and outliers of flower diameter of varieties provided by box plots,variety 16,2 and 4 were selected as the example varieties for the three expression states with respective flower diameter of 3.0-4.4,6.0-7.4 and 9.0-10.4 cm.[Conclusion] The box plot is an efficient method for the general analysis of varieties,which provides information covering the actual and possible expression range,median and outliers of measurements of flower diameter of each variety.It also provides references for selecting example varieties for other quantitative characteristics and evaluating the quality of varieties.