By dynamic method under UV irradiation, commercial melt-blown polypropylene (PPMB) filter element was modified with acrylamide (AAm) using benzophenone (BP) as initiator. Attenuated total reflection-Fourier tran...By dynamic method under UV irradiation, commercial melt-blown polypropylene (PPMB) filter element was modified with acrylamide (AAm) using benzophenone (BP) as initiator. Attenuated total reflection-Fourier transform infrared spectroscopy and scanning electron microscope verified that polyacrylamide chain was grafted on the fiber surface of PPMB filter element. Elemental content analysis with energy dispersive X-ray of fibers revealed that the polymerization content in the inner part of filter element was relatively higher than that in the outer. Degree of grafting changed with initiator concentration, monomer concentration, reaction temperature and reached 2.6% at the reaction condition: CBp=0.06 mol/L, CAAm=2.0 mol/L, irradiation time: 80 min, temperature: 60℃. Relative water flux altered with the hydrophilicity and pore size of filter element. In the antifouling test, the modified filter gave greater flux recovery (approximately 70%) after filtration of the water extract of Liuweidihuang, suggesting that the fouling layer was more easily reversible due to the hydrophilic nature of the modified filter.展开更多
In this paper, the radial temperature distributions of the blown CO2 arcs in a model gas circuit breaker were investigated by optical emission spectroscopy methods. The CO2 flows with different flow rates(50, 100 and ...In this paper, the radial temperature distributions of the blown CO2 arcs in a model gas circuit breaker were investigated by optical emission spectroscopy methods. The CO2 flows with different flow rates(50, 100 and 150 1 min^-1) were created to axially blow the arcs burning in a polymethyl methacrylate(PMMA) nozzle. Discharges with different arc currents(200 and 400A) were conducted in the experiment. The absolute intensity method was applied for a carbon ionic line of 657.8 nm to obtain the radial temperature profiles of the arc columns at a cross-section 1 mm above the nozzle. The calibration for the intensity of the CⅡ 657.8 nm line was achieved by the Fowler–Milne method with the help of an oxygen atomic line of 777.2 nm.The highest temperature obtained in the arc center was up to 19 900 K when the arc current was 400 A and the CO2 flow rate was 50 1 min^-1, while the lowest temperature in the arc center was about 15 900 K when the arc current was 200 A and the CO2 flow rate was 150 1min^-1. The results indicate that as the arc current increases, the temperature in the arc center would also increase apparently, and a larger gas flow rate would lead to a lower central temperature in general. It can also be found that the influence of the CO2 flow rate on the arc temperature was much less than that of the arc current under the present experimental conditions. In addition,higher temperature in the arc center would cause a sharper temperature decrease from the central region towards the edge.展开更多
基金Project supported by the Natural Science Foundation of Beijing(No.2051002)Science and Technology Programme of Beijing(No.D0205004040421)
文摘By dynamic method under UV irradiation, commercial melt-blown polypropylene (PPMB) filter element was modified with acrylamide (AAm) using benzophenone (BP) as initiator. Attenuated total reflection-Fourier transform infrared spectroscopy and scanning electron microscope verified that polyacrylamide chain was grafted on the fiber surface of PPMB filter element. Elemental content analysis with energy dispersive X-ray of fibers revealed that the polymerization content in the inner part of filter element was relatively higher than that in the outer. Degree of grafting changed with initiator concentration, monomer concentration, reaction temperature and reached 2.6% at the reaction condition: CBp=0.06 mol/L, CAAm=2.0 mol/L, irradiation time: 80 min, temperature: 60℃. Relative water flux altered with the hydrophilicity and pore size of filter element. In the antifouling test, the modified filter gave greater flux recovery (approximately 70%) after filtration of the water extract of Liuweidihuang, suggesting that the fouling layer was more easily reversible due to the hydrophilic nature of the modified filter.
基金supported by National Natural Science Foundation of China (Nos. 51577145, 51707144 and 51877165)the Key Research and Development Program of Shaanxi Province (No. 2018ZDXM-GY-112)the State Key Laboratory of Electrical Insulation and Power Equipment (No. EIPE19302)
文摘In this paper, the radial temperature distributions of the blown CO2 arcs in a model gas circuit breaker were investigated by optical emission spectroscopy methods. The CO2 flows with different flow rates(50, 100 and 150 1 min^-1) were created to axially blow the arcs burning in a polymethyl methacrylate(PMMA) nozzle. Discharges with different arc currents(200 and 400A) were conducted in the experiment. The absolute intensity method was applied for a carbon ionic line of 657.8 nm to obtain the radial temperature profiles of the arc columns at a cross-section 1 mm above the nozzle. The calibration for the intensity of the CⅡ 657.8 nm line was achieved by the Fowler–Milne method with the help of an oxygen atomic line of 777.2 nm.The highest temperature obtained in the arc center was up to 19 900 K when the arc current was 400 A and the CO2 flow rate was 50 1 min^-1, while the lowest temperature in the arc center was about 15 900 K when the arc current was 200 A and the CO2 flow rate was 150 1min^-1. The results indicate that as the arc current increases, the temperature in the arc center would also increase apparently, and a larger gas flow rate would lead to a lower central temperature in general. It can also be found that the influence of the CO2 flow rate on the arc temperature was much less than that of the arc current under the present experimental conditions. In addition,higher temperature in the arc center would cause a sharper temperature decrease from the central region towards the edge.