AIM: To explore the optimal low dose of MSCT in orbital trauma examination. METHODS: Sixty transverse images of the fracture layer were selected. Low-dose images acquired at 30, 70, 100, 140, 170, and 200 milliampere ...AIM: To explore the optimal low dose of MSCT in orbital trauma examination. METHODS: Sixty transverse images of the fracture layer were selected. Low-dose images acquired at 30, 70, 100, 140, 170, and 200 milliampere (mA) were simulated by adding noise to the image space using software. After assessing the images according to the conditions of image quality and fracture, we found the optimal tube current that met diagnostic requirements and then applied it to clinical use. The CT Dose Index volume (CTDIvol), dose length product (DLP) and effective dose (ED) were recorded. The image quality was classified as good, fairly good, ordinary, poor, or very poor according to image level, noise, anatomic structure and whether the diagnostic requirements were met or not. The rank-sum test was used to perform statistical analysis on the ranked data The Chi-square test was used for the numerical data. RESULTS: Under the scan conditions of a conventional dose of 300 mA, 60 cases of orbital fracture, 38 cases of orbital emphysema, 25 cases of ocular damage, and 3 cases of intraorbital foreign body were demonstrated in the images of the 60 orbital trauma patients. Among the low dose simulated images, the image quality difference of the different doses was of statistical significance (chi(2) =15.678, P =0.016). When the dose was lowered to 70 mA, the above mentioned clinical signs were still clear and diagnostic, however the image quality assessment results indicated that 2 cases were good, 16 cases were fairly good, and 42 cases were ordinary, poor or very poor. When the simulated dose tube current was 100mA, the image quality assessment results were 18 cases good, 34 cases fairly good, and 8 cases ordinary, poor and very poor; compared with the conventional dose, there was no statistical significance (P>0.05). When using a 100 mA tube current to examine 40 cases of orbital trauma patients in the clinic, the acquired image quality was 10 cases good, 26 cases fairly good and 4 cases ordinary, without any cases of poor or very poor. The CTDIvol, DLP and ED were 20.72mGy, 124.97mGy.cm and 0.26mSv, respectively, while the CTDIvol, DLP and ED were 62.53mGy, 375.18mGy.GTtl and 0.86mSv, respectively, when using a conventional dose of 300mA. Compared with the tube current of 100mA for scanning, the ED declined 70%. CONCLUSION: When conducting an MSCT scan for orbital trauma, the acquired images using the 100 mA tube current can meet the clinical diagnostic requirements, and the radiation dose to the patients can be decreased.展开更多
Aerodynamics of loitering munition is studied in this paper.The aerodynamic characteristics of loitering munition with non-circular body and body-airfoil-empennage combination are calculated numerically at Ma=0.4 base...Aerodynamics of loitering munition is studied in this paper.The aerodynamic characteristics of loitering munition with non-circular body and body-airfoil-empennage combination are calculated numerically at Ma=0.4 based on multi-griddings patching technology,in the range of angle of attack-4°-10°,and the analytical results were compared with those from wind tunnel experiments,they show a good consistency.Analysis of the results showed that the normal force generated by non-circular cross-section missile increases with the angle of attack.At α≥6°,normal force achieved by missile body can take up to 10% of the total lift.Together with the lifting surface,the loitering munitions can provide a better lift to drag ratio,an improved weapon range and a good longitudinal stability.展开更多
The Funk's section theorem in the n-complex space Cn is investigated. It turns out that this theorem does not admit an extension for the class of general origin-symmetric star bodies in Cn but for a class of star bod...The Funk's section theorem in the n-complex space Cn is investigated. It turns out that this theorem does not admit an extension for the class of general origin-symmetric star bodies in Cn but for a class of star bodies called generalized complex intersection bodies. A quasi-version of Funk's section theorem in Cn is established then.展开更多
文摘AIM: To explore the optimal low dose of MSCT in orbital trauma examination. METHODS: Sixty transverse images of the fracture layer were selected. Low-dose images acquired at 30, 70, 100, 140, 170, and 200 milliampere (mA) were simulated by adding noise to the image space using software. After assessing the images according to the conditions of image quality and fracture, we found the optimal tube current that met diagnostic requirements and then applied it to clinical use. The CT Dose Index volume (CTDIvol), dose length product (DLP) and effective dose (ED) were recorded. The image quality was classified as good, fairly good, ordinary, poor, or very poor according to image level, noise, anatomic structure and whether the diagnostic requirements were met or not. The rank-sum test was used to perform statistical analysis on the ranked data The Chi-square test was used for the numerical data. RESULTS: Under the scan conditions of a conventional dose of 300 mA, 60 cases of orbital fracture, 38 cases of orbital emphysema, 25 cases of ocular damage, and 3 cases of intraorbital foreign body were demonstrated in the images of the 60 orbital trauma patients. Among the low dose simulated images, the image quality difference of the different doses was of statistical significance (chi(2) =15.678, P =0.016). When the dose was lowered to 70 mA, the above mentioned clinical signs were still clear and diagnostic, however the image quality assessment results indicated that 2 cases were good, 16 cases were fairly good, and 42 cases were ordinary, poor or very poor. When the simulated dose tube current was 100mA, the image quality assessment results were 18 cases good, 34 cases fairly good, and 8 cases ordinary, poor and very poor; compared with the conventional dose, there was no statistical significance (P>0.05). When using a 100 mA tube current to examine 40 cases of orbital trauma patients in the clinic, the acquired image quality was 10 cases good, 26 cases fairly good and 4 cases ordinary, without any cases of poor or very poor. The CTDIvol, DLP and ED were 20.72mGy, 124.97mGy.cm and 0.26mSv, respectively, while the CTDIvol, DLP and ED were 62.53mGy, 375.18mGy.GTtl and 0.86mSv, respectively, when using a conventional dose of 300mA. Compared with the tube current of 100mA for scanning, the ED declined 70%. CONCLUSION: When conducting an MSCT scan for orbital trauma, the acquired images using the 100 mA tube current can meet the clinical diagnostic requirements, and the radiation dose to the patients can be decreased.
基金Sponsored by the Ministerial Level Advanced Research Foundation(51305010102)
文摘Aerodynamics of loitering munition is studied in this paper.The aerodynamic characteristics of loitering munition with non-circular body and body-airfoil-empennage combination are calculated numerically at Ma=0.4 based on multi-griddings patching technology,in the range of angle of attack-4°-10°,and the analytical results were compared with those from wind tunnel experiments,they show a good consistency.Analysis of the results showed that the normal force generated by non-circular cross-section missile increases with the angle of attack.At α≥6°,normal force achieved by missile body can take up to 10% of the total lift.Together with the lifting surface,the loitering munitions can provide a better lift to drag ratio,an improved weapon range and a good longitudinal stability.
文摘The Funk's section theorem in the n-complex space Cn is investigated. It turns out that this theorem does not admit an extension for the class of general origin-symmetric star bodies in Cn but for a class of star bodies called generalized complex intersection bodies. A quasi-version of Funk's section theorem in Cn is established then.