期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
An inverse method for online stress monitoring and fatigue life analysis of boiler drums 被引量:5
1
作者 胡文森 李斌 《Journal of Chongqing University》 CAS 2009年第2期89-96,共8页
A method based on solution of the inverse heat conduction problem was presented for online stress monitoring and fatigue life analysis of boiler drums. The mathematical model of the drum temperature distribution is ba... A method based on solution of the inverse heat conduction problem was presented for online stress monitoring and fatigue life analysis of boiler drums. The mathematical model of the drum temperature distribution is based on the assumptions that the difference of temperature along the longitudinal axis of the boiler drum is negligible with changes only in the radial direction and the circumferential direction, and that the outer surface of drum is thermaUy insulated. Combining this model with the control-volume method provides temperatures at different points on a cross-section of the drum. With the temperature data, the stresses and the life expectancy of the boiler drum are derived according to the ASME code. Applying this method to the cold start-up process of a 300 MW boiler demonstrated the absence of errors caused by the boundary condition assumptions on the inner surface of the drum and testified that the method is an applicable technique for the online stress monitoring and fatigue life analysis of boiler drums. 展开更多
关键词 boiler drum fatigue life temperature distribution online stress monitoring
下载PDF
Digital Control Design for the Boiler Drum BDT921
2
作者 Tatang Mulyana Mohamad Nor Mohd Than Dirman Hanafi Afrodi Ali 《Journal of Mechanics Engineering and Automation》 2011年第5期392-397,共6页
A boiler drum BDT921 that is installed in the Control Laboratory, Department of Mechatronics and Robotics Engineering, Faculty of Electric and Electronic Engineering, Universiti Tun Hussein Onn Malaysia (UTHM) is be... A boiler drum BDT921 that is installed in the Control Laboratory, Department of Mechatronics and Robotics Engineering, Faculty of Electric and Electronic Engineering, Universiti Tun Hussein Onn Malaysia (UTHM) is being used as a model plant to achieve the digital control system since its analog. Implementing a digital system to boiler quite a though work. This paper covers analysis from the experiment done to match with digital design that will be implemented to the real system. The digital control design will come up with the mathematical model and will be analyzed with MATLAB and SIMULINK software named as "Discrete Analysis ofBDT921 Simulation". A proportional integral and derivative (PID) controller is being chosen as the control element in discrete form as the real system is using the same control element. The output responses behave as the second order system with a bit difference in rise times and peak times compared with data obtained from experiment. With regarding to the analysis done, the digital control can be implemented and for further viewing, to be controlled digitally with computer in the control room. 展开更多
关键词 boiler drum digital control PID (proportional integral and derivative) controller MATLAB and SIMULINK.
下载PDF
Water Level Deviation Analysis of Levels Between Two Sides of the Boiler Drum
3
作者 Fei Xia Ya-Lei Quan +1 位作者 Hao Zhang Dao-Gang Peng 《International Journal of Automation and computing》 EI CSCD 2016年第2期142-150,共9页
It is always quite difficult to accurately measure boiler drum water level in power plant. Though the effect of false measurement of water level can be reduced with some devices, the effect of deviation of boiler drum... It is always quite difficult to accurately measure boiler drum water level in power plant. Though the effect of false measurement of water level can be reduced with some devices, the effect of deviation of boiler drum water level to the monitoring and alarm system, even to the control of drum water level, and so on, cannot be surmounted. Because of these reasons, the accurate water level alarm signal cannot be provided and the water level control measures cannot be applied. In order to solve this problem, a water level deviation analysis method is presented for analyzing boiler drum water level. Based on the analysis of boiler drum water level related running parameters, the relational model of water level deviation under different working conditions and its parameters is constructed. By analyzing this model, the specific impacts of the main factors can be fixed. Thus the drum water level deviation can be reduced by adjusting running parameters without changing unit load. And then the measurement of drum water level can be more accurate only if power plants have accurate measuring devices. Therefore, the boiler drum water level can be more accurately monitored and controlled. So, this innovation is important in ensuring the safe running of power plant. 展开更多
关键词 boiler drum water level deviation analysis MEASUREMENT safe running
原文传递
Design and application of a novel coal-fired drum boiler using saline water in heavy oil recovery
4
作者 Junping GU Yuxin WU +3 位作者 Liping WU Man ZHANG Hairui YANG Junfu LYU 《Frontiers in Energy》 SCIE CSCD 2020年第4期715-725,共11页
In this paper,the design and operation of a novel coal-fired circulating fluidized bed(CFB)drum boiler that can generate superheated steam using saline water were introduced.The natural circulation water dynamics with... In this paper,the design and operation of a novel coal-fired circulating fluidized bed(CFB)drum boiler that can generate superheated steam using saline water were introduced.The natural circulation water dynamics with a drum was adopted instead of the traditional once-through steam generator(OTSG)design,so that superheated steam can be generated for the better performance of the steam assisted gravity drainage(SAGD)technology in heavy oil recovery.The optimized staged evaporation method was proposed to further decrease the salinity of water in the clean water section of the boiler.The evaporating pipes of the salted water section were rearranged in the back pass of the boiler,where the heat load is low,to further improve the heat transfer safety.A CFB combustion technology was used for coal firing to achieve a uniform heat transfer condition with low heat flux.Pollutant control technologies were adopted to reduce pollutant emissions.Based on the field test,the recommended water standard for the coal-fired CFB drum boilers was determined.With the present technology,the treated recovery wastewater can be reused in steam-injection boilers to generate superheated steam.The engineering applications show that the boiler efficiency is higher than 90%,the blowdown rate is limited within 5.5%,and the superheat of steam can reach up to 30 K.Besides,the heavy oil recovery efficiency is significantly improved.Moreover,the pollutant emissions of SO2,NOV and dust are controlled within the ranges of 20-90 mg/(N·m^(3)),30-90 mg/(N·m^(3))and 2-10 mg/(N·m^(3))respectively. 展开更多
关键词 drum steam injection boiler natural circulation recovery wastewater staged evaporation circulating fluidized bed(CFB)
原文传递
上一页 1 下一页 到第