Mechanical Experimental Study on Tensile Bolted Connections of Cross-laminated Timber
1
作者 Chenxiao Su Haibei Xiong 《Structural Durability & Health Monitoring》 EI 2020年第1期81-94,共14页
In order to explore a kind of high-strength,earthquake-resistant,eco-nomical and suitable connection,4 groups of cross-laminated timber wall-to-floor and wall-to-wall bolted connections were tested under monotonic and... In order to explore a kind of high-strength,earthquake-resistant,eco-nomical and suitable connection,4 groups of cross-laminated timber wall-to-floor and wall-to-wall bolted connections were tested under monotonic and cyclic load-ing.The defommation characteristics and failure modes of the cross-laminated tim-ber wall-to-floor and wall-to-wall bolted connections were exploited.Load-slip curves,bearing capacity,yielding point,stiffness and ductility of each group of specimens were analyzed.The test results indicate that the loading process of cross-laminated timber bolted connections under tension can be categorized as five stages,namely the elastic stage,the slip stage,the embedding stage,the yield-ing stage and the ultimate stage.The ultimate tensile capacity of cross-laminated timber bolted wall-to-floor connections is 2.67 times that of the wall-to-wall bolted connections.Compared with cross-laminated timber self-tapping screwed connections,the ultimate tensile capacity of the cross-laminated timber wall-to-floor bolted connections is 2.70 times that of the self-tapping screwed connec-tions,and the ultimate tensile capacity of the cross-laminated timber wall-to-wall bolted connections is 3.83 times that of the self-tapping screwed connections.The crosslaminated timber bolted connections have larger yielding displacement and wider plastic range,and they are more energy dissipative and more ductile.Furthermore,the cost of the cross-laminated timber wall-to-floor bolted connec-tions is 46%that of the self-tapping screwed connections,while the cost of cross-laminated wall-to-wall bolted connections is 53%that of the self-screwed connections. 展开更多
关键词 Cross-laminated timber bolted connections mechanical properties economical and suitable
下载PDF
STRESS-STRAIN FINITE ELEMENT ANALYSIS AND FATIGUE LIFE PREDICTION FOR BOLTED CONNECTIONS 被引量:1
2
作者 Wang Ziqin Xie Qingsheng Mechanical Engineering Department,Guizhou University of Technology,Guiyang 550003,China 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2002年第1期75-78,共4页
A cyclic plasticity model is used into finite element (FE) method to obtainthe details of elastic-plastic stress-strain in the bolts under cyclic axial loading. Two criteriain multiaxial fatigue are employed to predic... A cyclic plasticity model is used into finite element (FE) method to obtainthe details of elastic-plastic stress-strain in the bolts under cyclic axial loading. Two criteriain multiaxial fatigue are employed to predict fatigue lives of bolts. The predicted fatigue livesare in favorable agreement with the experimental results for machined bolts. 展开更多
关键词 Finite element FATIGUE bolted connection
下载PDF
Multi-scale strength analysis of bolted connections used in integral thermal protection system 被引量:8
3
作者 Heng LIANG Yuqing WANG +1 位作者 Mingbo TONG Junhua ZHANG 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2018年第8期1728-1740,共13页
Efficient and accurate strength analysis of bolted connections is essential in analyzing the integral thermal protection system(ITPS) of hypersonic vehicles, since the system bears severe loads and structural failur... Efficient and accurate strength analysis of bolted connections is essential in analyzing the integral thermal protection system(ITPS) of hypersonic vehicles, since the system bears severe loads and structural failures usually occur at the connections. Investigations of composite mechanical properties used in ITPS are still in progress as the architecture of the composites is complex. A new method is proposed in this paper for strength analysis of bolted connections by investigating the elastic behavior and failure strength of three-dimensional C/C orthogonal composites used in ITPS. In this method a multi-scale finite element method incorporating the global–local method is established to ensure high efficiency in macro-scale and precision in meso-scale in analysis.Simulation results reveal that predictions of material properties show reasonable accuracy compared with test results. And the multi-scale method can analyze the strength of connections efficiently and accurately. 展开更多
关键词 bolted connection COMPOSITE Multi-scale method Strength analysis Thermal Protection System
原文传递
State-of-the-art on resistance of bearing-type bolted connections in high strength steel
4
作者 Guoqiang LI Yifan LYU Yanbo WANG 《Frontiers of Structural and Civil Engineering》 SCIE EI CSCD 2020年第3期569-585,共17页
With the recent development of material science,high strength steel(HSS)has become a practical solution for landmark buildings and major projects.The current codes for design of bearing-type bolted connections of stee... With the recent development of material science,high strength steel(HSS)has become a practical solution for landmark buildings and major projects.The current codes for design of bearing-type bolted connections of steel constructions were established based on the research of conventional steels.Since the mechanical properties of HSS are different from those of conventional steels,more works should be done to develop the appropriate approach for the design of bearing-type bolted connections in HSS.A review of the research carried out on bearing-type bolted connections fabricated from conventional steel and HSS is presented.The up-to-date tests conducted at Tongji University on four connection types fabricated from three grades of HSS with nominal yield strengths of 550,690,and 890 MPa are presented.The previous research on failure modes,bearing resistance and the design with consideration of bolt hole elongation are summarized.It is found that the behavior of bolted connections in HSS have no drastic difference compared to that of conventional steel connections.Although the ductility is reduced,plastic deformation capacity of HSS is sufficient to ensure the load redistribution between different bolts with normal construction tolerances.It is also found that behavior of each bolt of multi-bolt connections arranged in perpendicular to load direction is almost identical to that of a single-bolt connection with the same end distance.For connections with bolts arranged in parallel to load direction,the deformation capacity of the whole connection depends on the minimum value between the end distance and the spacing distances in load direction.The comparison with existing design codes shows that Eurocode3 and Chinese GB50017-2017 are conservative for the design of bolted connections in HSS while AISC 360-16 may overestimate the bearing resistance of bolted connections. 展开更多
关键词 High strength steel bolted connection bearing behavior design codes
原文传递
Simulation of Steel Reinforcement on the Nonlinear Behaviour of Slender Glulam Beam Columns by Using the Newton-Raphson Method
5
作者 Martial Ourmama Marcelline Blanche Manjia Edmond Dawak Fezeu 《Open Journal of Applied Sciences》 2024年第2期243-266,共24页
The current theory in NF EN 1995-1-1/NA of Eurocode 5, which is based on maximum deflection, has been investigated on softwoods. Therefore, this theory is not adapted for slender glulam beam columns made of tropical h... The current theory in NF EN 1995-1-1/NA of Eurocode 5, which is based on maximum deflection, has been investigated on softwoods. Therefore, this theory is not adapted for slender glulam beam columns made of tropical hardwood species from the Congo Basin. This maximum deflection is caused by a set of loads applied to the structure. However, Eurocode 5 doesn’t provide how to predict this deflection in case of long-term load for such structures. This can be done by studying load-displacement (P-Δ) behaviour of these structures while taking into account second order effects. To reach this goal, a nonlinear analysis has been performed on a three-dimensional beam column embedded on both ends. Since conducting experimental investigations on large span structural products is time-consuming and expensive especially in developing countries, a numerical model has been implemented using the Newton-Raphson method to predict load-displacement (P-Δ) curve on a slender glulam beam column made of tropical hardwood species. On one hand, the beam has been analyzed without wood connection. On the other hand, the beam has been analyzed with a bolted wood connection and a slotted-in steel plate. The load cases considered include self-weight and a uniformly applied long-term load. Combinations of serviceability limit states (SLS) and ultimate limit states (ULS) have also been considered, among other factors. A finite-element software RFEM 5 has been used to implement the model. The results showed that the use of steel can reduce displacement by 20.96%. Additionally, compared to the maximum deflection provided by Eurocode 5 for softwoods, hardwoods can exhibit an increasing rate of 85.63%. By harnessing the plastic resistance of steel, the bending resistance of wood can be increased by 32.94%. 展开更多
关键词 Nonlinear Analysis Newton-Raphson Method Maximum Deflection bolted Wood Connection Hardwood Species
下载PDF
Experimental and numerical investigation of a composite structure with frame and skin
6
作者 李传政 XU Shuyan +3 位作者 DONG Jihong LIU Bo ZHANG Yaoyu ZHENG Fusheng 《High Technology Letters》 EI CAS 2023年第1期22-30,共9页
A composite structure with frame and skin based on cabin structure in a large space telescope is studied in this paper.The frame is composed of longitudinal and transverse beams with hybrid bonded/bolted joints,and th... A composite structure with frame and skin based on cabin structure in a large space telescope is studied in this paper.The frame is composed of longitudinal and transverse beams with hybrid bonded/bolted joints,and the skin is connected to the frame by bolts.Tensile tests are conducted on the structure by a set of test stand.It is observed that residual deformation occurs in the first test of the structure,which is attributed to the relative sliding between the skin and frame because of bolt-hole clearances.The high tightening torque and the increased number of the skin-frame bolts contribute to the high stiffness of the structure.A finite element model(FEM)of this composite structure is established,and the simulation model is verified by the experimental results.The FEM is contrastively analyzed with different frame joints,and it is found that adhesive joining in the hybrid bonded/bolted joints enhances the stiffness of the structure significantly.Given that adhesive plays a leading role in the stiffness of the hybrid joints,Tie contact in FEM is proposed to simulate bonded or hybrid joints when studying the stiffness performance of undamaged structure. 展开更多
关键词 COMPOSITE tensile test hybrid bonded/bolted joint bolted connection finite element analysis
下载PDF
Mechanical Behavior of Light Trusses Made of Poplar Laminated Veneer Lumber and Connected with Bolts and Tooth Plates 被引量:1
7
作者 Yan Liu Yanfei Guo +1 位作者 Xufeng Sun Meng Gong 《Journal of Renewable Materials》 SCIE EI 2020年第9期1111-1127,共17页
Poplar Laminated Veneer Lumber(Poplar LVL)is a new type of engineering materials with high strength,good reliability and small variability.Poplar LVL is manufactured from the fast-growing poplar,which is widely used i... Poplar Laminated Veneer Lumber(Poplar LVL)is a new type of engineering materials with high strength,good reliability and small variability.Poplar LVL is manufactured from the fast-growing poplar,which is widely used in packaging,furniture and others,however,is rarely adopted in construction.In order to explore the feasibility of poplar LVL trusses in construction of roof,four 4.5-m-span Fink-and-Howe trusses were designed and assembled,which were made of poplar LVL with bolted-and tooth-plated connections.Vertical static loading on the upper chord joints of a truss was imposed by self-balancing test device.The mechanical properties of trusses were examined.The ultimate load,deformation character and failure mode of each truss were measured,observed and analyzed.Furthermore,four types of analytical models with different joint connection assumptions were used to estimate the ultimate load and deflection.The results showed that the poplar LVL trusses were basically in elastic stage before the design load was reached,showing good working performance under the action of design load.The bearing capacity of the trusses of bolted connections was greater than that of the tooth-plated connections.As for the same joint connection type,the bearing capacity of Fink trusses exceeded that of Howe trusses.The poplar LVL light trusses of both types of connections showed good structural performance,which could be reasonably used for building roof systems. 展开更多
关键词 Poplar LVL TRUSS mechanical properties bearing capacity bolted connection truss plate connections model
下载PDF
Research of Surface Coating Influence on Loose Life of Bolt
8
作者 ZHANG Yu 《International Journal of Plant Engineering and Management》 2022年第2期65-85,共21页
The rust⁃proof ability relate to the reliability of bolt connection,and the painting is the most simple and effective rust⁃proof method in industry.Because of lacking general standard,there are different coating thick... The rust⁃proof ability relate to the reliability of bolt connection,and the painting is the most simple and effective rust⁃proof method in industry.Because of lacking general standard,there are different coating thicknesses painted on the surface of workpieces,which influences the loose life of connecting bolt.For the longer loose life,Three kinds of applied coatings(primer coating,primer+top⁃coat coating,primer+intermediate⁃coat+top⁃coat coating)in industry are tested in the experiment,and the best coating is found.All the conclusions gotten by analyzing the testing phenomenon of every coating shown in experiment,have profound meaning for practical industry application. 展开更多
关键词 COATING bolt connection EXPERIMENT loose life
下载PDF
Behavior of axially loaded tubular X-joints using bolted connection:mechanical model and validation 被引量:1
9
作者 Yong CHEN Ji-yang WANG +3 位作者 Yong GUO Guo-hui SHEN Li-xian YANG Bin-nan SUN 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2013年第12期880-889,共10页
X-joints are one of the fundamental joint configurations used in a wide range of transmission tubular structures.Experimental investigation of four tubular X-joints with bolted connection was conducted in this study,a... X-joints are one of the fundamental joint configurations used in a wide range of transmission tubular structures.Experimental investigation of four tubular X-joints with bolted connection was conducted in this study,and it was found that the annular plate was the main yielding control member of such X-joints.Moreover,the portion outside the effective width of the chord member still had a restriction effect on the annular plate,which led to reducing the yielding strength of the joint,while the gusset plate could help to improve the yield strength capacity.In the current design code of steel structures,the contribution to the strength capacity of the gusset plate has not been taken into account.Therefore,based on some mechanical assumptions,a general mechanical model was proposed.After the introduction of the gusset plate strength capacity factor,the yield capacity simplified calculation method of such X-joints was derived.Through the analyses of such X-joints with various diameters and thicknesses,it was concluded that a simple mechanical model could predict test results very well and that the contribution of the gusset plate was also taken into account. 展开更多
关键词 Steel tubular X-joint bolted connection Annular plate Gusset plate Strength capacity
原文传递
Fatigue Life Prediction for Flange Connecting Bolts of Wind Turbine Tower 被引量:2
10
作者 于泽林 孙鹏文 王栋 《Journal of Shanghai Jiaotong university(Science)》 EI 2020年第4期526-530,共5页
Flange joint part is the weak link of wind turbine tower.In view of the special structure,complex stress and easy failure of the connecting bolt of the wind turbine tower flange,the relationship between the external l... Flange joint part is the weak link of wind turbine tower.In view of the special structure,complex stress and easy failure of the connecting bolt of the wind turbine tower flange,the relationship between the external load of the tower section and the internal stress of the bolt is established by the finite element method,and the time series internal stress of the bolt is calculated by the Schmidt-Neuper algorithm.The S-N curve which is suitable for the connecting bolt material of the tower flange is selected by the GL2010 specification.On the basis of Miner’s fatigue cumulative damage theory and rain flow counting method,the fatigue strength of the whole ring bolt is roughly calculated,and the most dangerous part is determined.The axial symmetry model of screw connection is used for accurately calculating the fatigue cumulative damage of the bolt at the dangerous part.The results show that the fatigue life of the bolts in the most dangerous position can meet the requirements,the engineering algorithm has advantages in determining the dangerous part of the whole ring bolt,and the finite element method has high accuracy in predicting the fatigue life of the bolts in the dangerous part.The proposed method is feasible and effective in predicting the fatigue life of the flange joint bolts of the tower. 展开更多
关键词 fatigue cumulative damage internal stress of bolt engineering algorithm flange connecting bolt wind turbine tower
原文传递
上一页 1 下一页 到第