期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Extended Bonner sphere spectrometer for dynamic neutron spectrum on HL-2A
1
作者 蒋春雨 曹靖 +4 位作者 刘子豪 蒋小菲 宋先瑛 张轶泼 阴泽杰 《Plasma Science and Technology》 SCIE EI CAS CSCD 2017年第7期118-123,共6页
The extended Bonner sphere spectrometer (EBSS) at the HL-2A tokamak for the neutron spectrum is described. This device was developed on the basis of previous Bonner sphere spectrometry (BSS), aiming to obtain a mo... The extended Bonner sphere spectrometer (EBSS) at the HL-2A tokamak for the neutron spectrum is described. This device was developed on the basis of previous Bonner sphere spectrometry (BSS), aiming to obtain a more accurate neutron spectrum in the HL-2A tokamak hall. The previous BSS contained eight Bonner spheres (BS). This EBSS contains 13 3He-filled detectors embedded in polyethylene spheres (PS), pre-amplifiers, and a parallel processing data acquisition system (DAQ). A response matrix is simulated in Geant4 taking the effect of the environment into account. 展开更多
关键词 extended bonner sphere spectrometer neutron spectrum TOKAMAK
下载PDF
Calculation of Response Function for Bonner Sphere Spectrometer Based on Geant4
2
作者 曹靖 蒋小菲 +2 位作者 蒋春雨 曹宏睿 阴泽杰 《Plasma Science and Technology》 SCIE EI CAS CSCD 2015年第1期80-83,共4页
In order to make further studies on fusion neutron diagnosis on HL-2A /HL-2M,we have developed and succeeded in the calculation of the Response Function for a Bonner sphere spectrometer,which consists of eight polyeth... In order to make further studies on fusion neutron diagnosis on HL-2A /HL-2M,we have developed and succeeded in the calculation of the Response Function for a Bonner sphere spectrometer,which consists of eight polyethylene spheres with ^3He proportional counters inside.The response function of the Bonner spectrometer to neutrons is of fundamental importance for its neutron spectrum unfolding procedure and is directly related to the quality of the unfolded spectrum.In this paper,we calculated the response function to neutrons from 10^-9 MeV to100 MeV by Geant4.In order to test the accuracy of the Geant4 simulation,we apply it to measure an ^241Am-Be neutron source,and the measured neutron counts of the spectrometer and simulated counts are found to be highly consistent,with a relative error up to 9.3%.This has proven the calculation of the neutron response of the Bonner sphere spectrometer by Geant4 to be quite accurate. 展开更多
关键词 bonner sphere spectrometer response function Geant4 HL-2A HL-2M multi-sphere spectrometer Monte Carlo ^241Am-Be neutron source
下载PDF
The study of a neutron spectrum unfolding method based on particle swarm optimization combined with maximum likelihood expectation maximization 被引量:1
3
作者 Hong-Fei Xiao Qing-Xian Zhang +5 位作者 He-Yi Tan Bin Shi Jun Chen Zhi-Qiang Cheng Jian Zhang Rui Yang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第4期149-160,共12页
The neutron spectrum unfolding by Bonner sphere spectrometer(BSS) is considered a complex multidimensional model,which requires complex mathematical methods to solve the first kind of Fredholm integral equation. In or... The neutron spectrum unfolding by Bonner sphere spectrometer(BSS) is considered a complex multidimensional model,which requires complex mathematical methods to solve the first kind of Fredholm integral equation. In order to solve the problem of the maximum likelihood expectation maximization(MLEM) algorithm which is easy to suffer the pitfalls of local optima and the particle swarm optimization(PSO) algorithm which is easy to get unreasonable flight direction and step length of particles, which leads to the invalid iteration and affect efficiency and accuracy, an improved PSO-MLEM algorithm, combined of PSO and MLEM algorithm, is proposed for neutron spectrum unfolding. The dynamic acceleration factor is used to balance the ability of global and local search, and improves the convergence speed and accuracy of the algorithm. Firstly, the Monte Carlo method was used to simulated the BSS to obtain the response function and count rates of BSS. In the simulation of count rate, four reference spectra from the IAEA Technical Report Series No. 403 were used as input parameters of the Monte Carlo method. The PSO-MLEM algorithm was used to unfold the neutron spectrum of the simulated data and was verified by the difference of the unfolded spectrum to the reference spectrum. Finally, the 252Cf neutron source was measured by BSS, and the PSO-MLEM algorithm was used to unfold the experimental neutron spectrum.Compared with maximum entropy deconvolution(MAXED), PSO and MLEM algorithm, the PSO-MLEM algorithm has fewer parameters and automatically adjusts the dynamic acceleration factor to solve the problem of local optima. The convergence speed of the PSO-MLEM algorithm is 1.4 times and 3.1 times that of the MLEM and PSO algorithms. Compared with PSO, MLEM and MAXED, the correlation coefficients of PSO-MLEM algorithm are increased by 33.1%, 33.5% and 1.9%, and the relative mean errors are decreased by 98.2%, 97.8% and 67.4%. 展开更多
关键词 Particle swarm optimization Maximum likelihood expectation maximization Neutron spectrum unfolding bonner spheres spectrometer Monte Carlo method