Borehole thermal energy storage(BTES)systems have garnered significant attention owing to their efficacy in storing thermal energy for heating and cooling applications.Accurate modeling is paramount for ensuring the p...Borehole thermal energy storage(BTES)systems have garnered significant attention owing to their efficacy in storing thermal energy for heating and cooling applications.Accurate modeling is paramount for ensuring the precise design and operation of BTES systems.This study conducts a sensitivity analysis of BTES modeling by employing a comparative investigation of five distinct parameters on a wedge-shaped model,with implications extendable to a cylindrical configuration.The parameters examined included two design factors(well spacing and grout thermal conductivity),two operational variables(charging and discharging rates),and one geological attribute(soil thermal conductivity).Finite element simulations were carried out for the sensitivity analysis to evaluate the round-trip efficiency,both on a per-cycle basis and cumulatively over three years of operation,serving as performance metrics.The results showed varying degrees of sensitivity across different models to changes in these parameters.In particular,the round-trip efficiency exhibited a greater sensitivity to changes in spacing and volumetric flow rate.Furthermore,this study underscores the importance of considering the impact of the soil and grout-material thermal conductivities on the BTES-system performance over time.An optimized scenario is modelled and compared with the base case,over a comparative assessment based on a 10-year simulation.The analysis revealed that,at the end of the 10-year period,the optimized BTES model achieved a cycle efficiency of 83.4%.This sensitivity analysis provides valuable insights into the merits and constraints of diverse BTES modeling methodologies,aiding in the selection of appropriate modeling tools for BTES system design and operation.展开更多
Underground Thermal Energy Storage(UTES)store unstable and non-continuous energy underground,releasing stable heat energy on demand.This effectively improve energy utilization and optimize energy allocation.As UTES te...Underground Thermal Energy Storage(UTES)store unstable and non-continuous energy underground,releasing stable heat energy on demand.This effectively improve energy utilization and optimize energy allocation.As UTES technology advances,accommodating greater depth,higher temperature and multi-energy complementarity,new research challenges emerge.This paper comprehensively provides a systematic summary of the current research status of UTES.It categorized different types of UTES systems,analyzes the applicability of key technologies of UTES,and evaluate their economic and environmental benefits.Moreover,this paper identifies existing issues with UTES,such as injection blockage,wellbore scaling and corrosion,seepage and heat transfer in cracks,etc.It suggests deepening the research on blockage formation mechanism and plugging prevention technology,improving the study of anticorrosive materials and water treatment technology,and enhancing the investigation of reservoir fracture network characterization technology and seepage heat transfer.These recommendations serve as valuable references for promoting the high-quality development of UTES.展开更多
文摘Borehole thermal energy storage(BTES)systems have garnered significant attention owing to their efficacy in storing thermal energy for heating and cooling applications.Accurate modeling is paramount for ensuring the precise design and operation of BTES systems.This study conducts a sensitivity analysis of BTES modeling by employing a comparative investigation of five distinct parameters on a wedge-shaped model,with implications extendable to a cylindrical configuration.The parameters examined included two design factors(well spacing and grout thermal conductivity),two operational variables(charging and discharging rates),and one geological attribute(soil thermal conductivity).Finite element simulations were carried out for the sensitivity analysis to evaluate the round-trip efficiency,both on a per-cycle basis and cumulatively over three years of operation,serving as performance metrics.The results showed varying degrees of sensitivity across different models to changes in these parameters.In particular,the round-trip efficiency exhibited a greater sensitivity to changes in spacing and volumetric flow rate.Furthermore,this study underscores the importance of considering the impact of the soil and grout-material thermal conductivities on the BTES-system performance over time.An optimized scenario is modelled and compared with the base case,over a comparative assessment based on a 10-year simulation.The analysis revealed that,at the end of the 10-year period,the optimized BTES model achieved a cycle efficiency of 83.4%.This sensitivity analysis provides valuable insights into the merits and constraints of diverse BTES modeling methodologies,aiding in the selection of appropriate modeling tools for BTES system design and operation.
基金supported by the National Nature Science Foundation of China under grant No.42272350the Foundation of Shanxi Key Laboratory for Exploration and Exploitation of Geothermal Resources under grant No.SX202202.
文摘Underground Thermal Energy Storage(UTES)store unstable and non-continuous energy underground,releasing stable heat energy on demand.This effectively improve energy utilization and optimize energy allocation.As UTES technology advances,accommodating greater depth,higher temperature and multi-energy complementarity,new research challenges emerge.This paper comprehensively provides a systematic summary of the current research status of UTES.It categorized different types of UTES systems,analyzes the applicability of key technologies of UTES,and evaluate their economic and environmental benefits.Moreover,this paper identifies existing issues with UTES,such as injection blockage,wellbore scaling and corrosion,seepage and heat transfer in cracks,etc.It suggests deepening the research on blockage formation mechanism and plugging prevention technology,improving the study of anticorrosive materials and water treatment technology,and enhancing the investigation of reservoir fracture network characterization technology and seepage heat transfer.These recommendations serve as valuable references for promoting the high-quality development of UTES.