The cooling of a(pebble bed)spent fuel in a high-temperature gas-cooled reactor(HTGR)is adversely affected by an increase in the temperature of the used gas(air).To investigate this problem,a configuration consisting ...The cooling of a(pebble bed)spent fuel in a high-temperature gas-cooled reactor(HTGR)is adversely affected by an increase in the temperature of the used gas(air).To investigate this problem,a configuration consisting of three copper spheres arranged in tandem subjected to a forced mistflow inside a cylindrical channel is considered.The heat transfer coefficients and related variations as a function of Reynolds number are investigated accord-ingly.The experimental results show that when compared to those with only airflow,the heat transfer coefficient of the spherical elements with mistflow(j=112 kg/m2 hr,Re=55000)increases by 180%,75%,and 20%,respec-tively for thefirst,second,and third spherical element(the corresponding heat transfer enhancement ratio being 2.3,1.4,and 1.1).Additional numerical simulations reveal that the presence of stagnant zones with intense vortex formation around each spherical element contributes significantly to determine the heat transfer behavior.展开更多
This study focuses on the experimental measurements of the heat transfer coefficient over a flat plate with a 30° leading edge. Under forced convection by a hot/cold air and flow over a cooled/heated flat plate, ...This study focuses on the experimental measurements of the heat transfer coefficient over a flat plate with a 30° leading edge. Under forced convection by a hot/cold air and flow over a cooled/heated flat plate, the thermal boundary layer and its thickness are quantitatively visualized and measured using a Mach-Zehnder interferometer. In addition, the variation in the local heat transfer coefficient is evaluated experimentally with respect to the air flow velocity and temperature. Differences within the heat transfer performance between the plates are confirmed and discussed. As a result, the average heat transfer performance is about the same for the heated plate and the cooled plate under all air velocity conditions. This contrasts with the theoretical prediction in the case of low air velocity, the reason considered was that the buoyancy at the 30° leading edge blocked air from flowing across the surface of the plate.展开更多
文摘The cooling of a(pebble bed)spent fuel in a high-temperature gas-cooled reactor(HTGR)is adversely affected by an increase in the temperature of the used gas(air).To investigate this problem,a configuration consisting of three copper spheres arranged in tandem subjected to a forced mistflow inside a cylindrical channel is considered.The heat transfer coefficients and related variations as a function of Reynolds number are investigated accord-ingly.The experimental results show that when compared to those with only airflow,the heat transfer coefficient of the spherical elements with mistflow(j=112 kg/m2 hr,Re=55000)increases by 180%,75%,and 20%,respec-tively for thefirst,second,and third spherical element(the corresponding heat transfer enhancement ratio being 2.3,1.4,and 1.1).Additional numerical simulations reveal that the presence of stagnant zones with intense vortex formation around each spherical element contributes significantly to determine the heat transfer behavior.
文摘This study focuses on the experimental measurements of the heat transfer coefficient over a flat plate with a 30° leading edge. Under forced convection by a hot/cold air and flow over a cooled/heated flat plate, the thermal boundary layer and its thickness are quantitatively visualized and measured using a Mach-Zehnder interferometer. In addition, the variation in the local heat transfer coefficient is evaluated experimentally with respect to the air flow velocity and temperature. Differences within the heat transfer performance between the plates are confirmed and discussed. As a result, the average heat transfer performance is about the same for the heated plate and the cooled plate under all air velocity conditions. This contrasts with the theoretical prediction in the case of low air velocity, the reason considered was that the buoyancy at the 30° leading edge blocked air from flowing across the surface of the plate.