期刊文献+
共找到247篇文章
< 1 2 13 >
每页显示 20 50 100
Numerical study of the cross-shore range and the intensity of the Nearshore Kuroshio Branch Current(NKBC)
1
作者 Jie YAN Yijun HOU +1 位作者 Peng QI Fang HU 《Journal of Oceanology and Limnology》 SCIE CAS CSCD 2022年第1期37-54,共18页
Temperature and salinity data,obtained by two snapshot surveys during 19-20 May 2019 and 12-25 September 2019 across the East China Sea(ECS)shelf,revealed that the Kuroshio intrusion to the north of 28°N comprise... Temperature and salinity data,obtained by two snapshot surveys during 19-20 May 2019 and 12-25 September 2019 across the East China Sea(ECS)shelf,revealed that the Kuroshio intrusion to the north of 28°N comprised the Nearshore Kuroshio Branch Current(NKBC)and the Off shore Kuroshio Branch Current(OKBC)at the bottom of the ECS during spring 2019,and that the NKBC was weak during autumn 2019.The Regional Ocean Model System was used to reproduce the distribution of water masses and the current structure over the continental shelf of the ECS during 2019.Analyses of the momentum balances indicated that the cross-shore range and the intensity of the NKBC were determined by the combination of the geostrophic fl ow and bottom Ekman current.In comparison with that in May 2019,a weakened shoreward bottom Ekman current and an increased off shoreward geostrophic fl ow caused the disappearance of cross-shore range of the NKBC in September 2019.Meanwhile,a diminished northeastward alongshore geostrophic fl ow in September 2019 also weakened the intensity of the NKBC.Sensitivity experiments indicated that a strong southwestward wind can push the western(eastern)boundary of the NKBC further off shoreward(shoreward)by increasing(decreasing)the off shore geostrophic fl ow(bottom Ekman current).A weak Taiwan Warm Current(TWC)can move the eastern boundary of the NKBC shoreward by decreasing the onshore bottom Ekman current.A weak Kuroshio Current(KC)can move the eastern boundary of the NKBC shoreward by increasing the off shoreward geostrophic fl ow.Furthermore,a strong(weak)southwestward wind,weak(strong)TWC,and strong(weak)KC can diminish(enhance)the intensity of the NKBC.Of the three factors,the wind plays the major role in infl uencing the NKBC. 展开更多
关键词 East China Sea Nearshore Kuroshio branch current(NKBC) Regional Ocean Model System(ROMS) ocean modeling
下载PDF
A branch current estimation and correction method for a parallel connected battery system based on dual BP neural networks
2
作者 Quanqing Yu Yukun Liu +3 位作者 Shengwen Long Xin Jin Junfu Li Weixiang Shen 《Green Energy and Intelligent Transportation》 2022年第2期112-123,共12页
In the actual use of a parallel battery pack in electric vehicles(EVs),current distribution in each branch will be different due to inconsistence characteristics of each battery cell.If the branch current is approxima... In the actual use of a parallel battery pack in electric vehicles(EVs),current distribution in each branch will be different due to inconsistence characteristics of each battery cell.If the branch current is approximately calculated by the total current of the battery pack divided by the number of the parallel branches,there will be a large error between the calculated branch current and the real branch current.Adding current sensors to measure each branch current is not practical because of the high cost.Accurate estimation of branch currents can give a safety warning in time when the parallel batteries of EVs are seriously inconsistent.This paper puts forward a method to estimate and correct branch currents based on dual back propagation(BP)neural networks.In the proposed method,one BP neural network is used to estimate branch currents,the other BP neural network is used to reduce the estimation error cause by current pulse excitations.Furthermore,this paper makes discussions on the selection of the best inputs for the dual BP neural networks and the adaptability of the method for different battery capacity and resistence differences.The effectiveness of the proposed method is verified by multiple dynamic conditions of two cells connected in parallel. 展开更多
关键词 BP neural Network branch current estimation and correction Electric vehicles Lithium-ion battery pack
原文传递
GENERATOR VIBRATION FAULT DIAGNOSIS METHOD BASED ON ROTOR VIBRATION AND STATOR WINDING PARALLEL BRANCHES CIRCULATING CURRENT CHARACTERISTICS 被引量:2
3
作者 Wan Shuting Li Heming +1 位作者 Li Yonggang Tang Guiji 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2005年第4期592-596,共5页
Rotor vibration characteristics are first analyzed, which are that the rotor vibration of fundamental frequency will increase due to rotor winding inter-turn short circuit fault, air-gap dynamic eccentricity fault, or... Rotor vibration characteristics are first analyzed, which are that the rotor vibration of fundamental frequency will increase due to rotor winding inter-turn short circuit fault, air-gap dynamic eccentricity fault, or imbalance fault, and the vibration of the second frequency will increase when the air-gap static eccentricity fault occurs. Next, the characteristics of the stator winding parallel branches circulating current are analyzed, which are that the second harmonics circulating current will increase when the rotor winding inter-turn short circuit fault occurs, and the fundamental circulating current will increase when the air-gap eccentricity fault occurs, neither being strongly affected by the imbalance fault. Considering the differences of the rotor vibration and circulating current characteristics caused by different rotor faults, a method of generator vibration fault diagnosis, based on rotor vibration and circulating current characteristics, is developed. Finally, the rotor vibration and circulating current of a type SDF-9 generator is measured in the laboratory to verify the theoretical analysis presented above. 展开更多
关键词 Generator Fault diagnosis Rotor vibration characteristic Stator winding parallel branches circulating current
下载PDF
含逆变型分布式电源和分支负荷的配电网自适应电流差动保护
4
作者 王钢 冯婧桐 李杰 《电网技术》 EI CSCD 北大核心 2024年第6期2593-2602,I0099-I0102,共14页
电流差动保护具有良好的选择性和灵敏性。但是,逆变型分布式电源(inverter-interfaced distributed generator,IIDG)和分支负荷接入改变了配电网的故障特性,现有配电网的电流差动保护面临拒动或误动的风险。为解决以上问题,该文在计及P/... 电流差动保护具有良好的选择性和灵敏性。但是,逆变型分布式电源(inverter-interfaced distributed generator,IIDG)和分支负荷接入改变了配电网的故障特性,现有配电网的电流差动保护面临拒动或误动的风险。为解决以上问题,该文在计及P/Q控制的IIDG和分支负荷的故障等值建模基础上,从故障点、IIDG和分支负荷的相对位置出发,挖掘配电网线路两端正序电流差的幅值特征以及正序电流故障分量的相位特征。在此基础上,提出一种正序电流幅值与故障分量相角阈值配合的双比例制动系数自适应差动保护方案,并且利用幅相平面分析所提保护判据的可靠性和灵敏性。最后通过PSCAD/EMTDC验证了所提保护方案的有效性,仿真结果表明该方案适应不同故障类型、位置和过渡电阻,且不受IIDG以及分支负荷接入的影响。 展开更多
关键词 配电网 逆变型分布式电源 分支负荷 自适应电流差动保护 正序故障分量
下载PDF
基于单端分支系数的四端柔直环网线路保护方案
5
作者 束洪春 任敏 +1 位作者 田鑫萃 李涛 《高电压技术》 EI CAS CSCD 北大核心 2024年第2期683-692,I0014-I0016,共13页
为提升直流线路保护在柔性直流环网中的速动性与可靠性,提出一种基于单端分支系数的保护方案。分析了不同故障位置下各换流阀提供的故障电流分量,并根据单端换流阀极线电流突变量构造分支系数,结果表明线路保护区内故障下的单端分支系... 为提升直流线路保护在柔性直流环网中的速动性与可靠性,提出一种基于单端分支系数的保护方案。分析了不同故障位置下各换流阀提供的故障电流分量,并根据单端换流阀极线电流突变量构造分支系数,结果表明线路保护区内故障下的单端分支系数小于区外故障,利用该特征构造区内、外故障识别元件。在线路高阻接地致使主保护失效时,根据桥臂最大允许电流决定线路纵联后备保护的开放时限,以优化现有主、后备保护方案之间的时序配合方案,保障各种直流线路故障工况下,换流阀不间断运行。保护方案不依赖线路边界元件,算法简单,大量仿真结果表明,该方案有良好的耐受过渡电阻能力,能在换流阀闭锁前实现故障区域可靠识别。 展开更多
关键词 柔性直流电网 分支系数 接地故障 故障电流解析 故障识别 保护时序配合
下载PDF
判断左束支起搏成功夺获标准的研究进展
6
作者 岳岸娜 钱步云 +2 位作者 陈璐 孙康云 邹建刚 《心血管病学进展》 CAS 2024年第4期289-294,共6页
左束支起搏(LBBP)定义为起搏夺获左束支,包括左束支主干及其分支,伴或不伴周围心肌夺获,且夺获阈值一般不超过1.5 V/0.4 ms。记录到逆行希氏束电位或顺行左束支电位是左束支夺获的直接证据,但该操作较为复杂,临床使用较少。在起搏导线... 左束支起搏(LBBP)定义为起搏夺获左束支,包括左束支主干及其分支,伴或不伴周围心肌夺获,且夺获阈值一般不超过1.5 V/0.4 ms。记录到逆行希氏束电位或顺行左束支电位是左束支夺获的直接证据,但该操作较为复杂,临床使用较少。在起搏导线植入过程中,通常根据心电图变化来判断导线是否成功夺获左束支,具体包括体表心电图QRS波群形态、左心室达峰时间变化、腔内心电图检测到左束支电位或损伤电流,以及改变起搏输出时观察到非选择性LBBP转换到选择性LBBP或左心室间隔部起搏等。由于患者存在个体差异,一些学者提出了个体化的左心室达峰时间、V_(6)-V_(1)峰值间期以及LBBP评分等方法进一步补充了夺获标准。现对目前常用的标准进行分析总结,为临床操作提供更多依据,以提高LBBP手术成功率。 展开更多
关键词 左束支起搏 左束支夺获标准 左束支电位 损伤电流 左心室激动时间
下载PDF
一种具有电能质量监测的总线式支路控制器
7
作者 徐越飞 陈世喆 +2 位作者 徐寅飞 周杰 喻擎苍 《科技创新与应用》 2024年第11期127-130,共4页
随着大功率开关管越来越广泛的使用,电流谐波对电力系统的影响日益加重,导致整个系统电能质量逐渐下降。该文设计并实现一种基于CAN总线的支路控制器,该控制器通过对支路电流的实时采集、频谱分析实现对支路电流谐波的在线检测,如发现... 随着大功率开关管越来越广泛的使用,电流谐波对电力系统的影响日益加重,导致整个系统电能质量逐渐下降。该文设计并实现一种基于CAN总线的支路控制器,该控制器通过对支路电流的实时采集、频谱分析实现对支路电流谐波的在线检测,如发现支路电流谐波异常,该控制器通过CAN总线上报主控节点,由主控节点统筹决策。主控节点的决策指令通过CAN总线下达到控制器,可指示控制器切断支路,以保障主控节点下的全局电能质量。该控制器在一个芯片完成电流采集、分析、通信和控制,多个控制器通过总线串联连接,具有接线简单、体积小、成本低的特点,为保障电力供给的稳定性和电能质量提供一种解决方案。 展开更多
关键词 总线式 电流质量 监测 支路 控制器
下载PDF
配电电缆冷缩中间接头受潮特性研究
8
作者 李巍巍 张睿 +3 位作者 罗洋 雷潇 曹晓燕 傅尧 《绝缘材料》 CAS 北大核心 2024年第4期60-65,共6页
为探究现阶段配电电缆冷缩中间接头的受潮特性,本文首先制作了带接头的未受潮试样,通过加速受潮老化平台对试样进行受潮处理,然后采用极化/去极化电流(PDC)测试系统分别测试未受潮和受潮2、4、6、8周时中间接头的极化/去极化电流,最后... 为探究现阶段配电电缆冷缩中间接头的受潮特性,本文首先制作了带接头的未受潮试样,通过加速受潮老化平台对试样进行受潮处理,然后采用极化/去极化电流(PDC)测试系统分别测试未受潮和受潮2、4、6、8周时中间接头的极化/去极化电流,最后计算其直流电导率,并使用支路辨识方法得到三条R-C支路的时间常数。结果表明:直流电导率在接头受潮到一定程度后才会发生变化,而第三支路时间常数随着受潮程度加重而不断减小,这是由于水分降低界面电荷迁移阻力,使得界面极化时间减小所致,因此第三支路时间常数可灵敏反映电缆中间接头的受潮程度,可作为判断电缆中间接头受潮程度的特征参数。 展开更多
关键词 PDC测试 中间接头 受潮老化 极化/去极化电流 直流电导率 第三支路时间常数
下载PDF
Branch Processes of Regular Magnetic Monopole
9
作者 MO Shu-Fan REN Ji-Rong ZHU Tao 《Communications in Theoretical Physics》 SCIE CAS CSCD 2009年第2期293-298,共6页
在这篇论文,由使用 Duan 的拓扑的当前的理论,常规磁性的单极的分支过程详细被讨论。常规磁性的单极被发现在限制点产生或歼灭并且遇到,切开,或向量顺序参数地(x) 系统地在分叉点和退化的点合并。而且,常规磁性的单极什么时候在地... 在这篇论文,由使用 Duan 的拓扑的当前的理论,常规磁性的单极的分支过程详细被讨论。常规磁性的单极被发现在限制点产生或歼灭并且遇到,切开,或向量顺序参数地(x) 系统地在分叉点和退化的点合并。而且,常规磁性的单极什么时候在地功能的退化的点切开了或合并,也被看那,常规磁性的单极的全部的拓扑的费用仍然是未改变的。 展开更多
关键词 磁单极子 分支过程 载体系统 极限点 退化点 分岔点 拓扑 分裂
下载PDF
Numerical simulation of the upper ocean currents in South China Sea
10
作者 Li Rongfeng Huang Qizhou and Wang Wenzhi(Institute of Atmospheric Physics, Chinese Academy of Sciences, Beijing 100080. China)(South China Sea Institute of Oceanology, Chinese Academy of Sciences, Guangzhou 510301, China) 《Acta Oceanologica Sinica》 SCIE CAS CSCD 1995年第3期305-317,共13页
The upper ocean currents in the Pacific Ocean are calculated by using an ocean model with higher horizontal resolution. The large current systems in the Pacific Ocean, such as Kuroshio, Oyashio, NEC, SEC, NECC,Califom... The upper ocean currents in the Pacific Ocean are calculated by using an ocean model with higher horizontal resolution. The large current systems in the Pacific Ocean, such as Kuroshio, Oyashio, NEC, SEC, NECC,Califomia Current and East Australia Current, are well simulated. This paper only gives the numerical simulation results of the upper ocean currents of the representative months in four seasons in the South China Sea (SCS). It showsthat the SCS branch of Kuroshio is the most important current in the northem SCS and it is not only the water resourceof the SCS warm current but also a significant part of the overall SCS circulation. There is a relatively strong northeastward flow entering the SCS through the Taiwan Strait throughout the year except for specific months. Some of thenumerical results have been confirmed by the observational evidences. 展开更多
关键词 Upper ocean current numerical simulation SCS warm current the SCS branch of Kuroshio slope of sealevel
下载PDF
基于谐波信号注入的含逆变型分布式电源配电网电流差动保护 被引量:1
11
作者 李海锋 张正刚 +2 位作者 梁远升 梁华敏 王钢 《电力系统自动化》 EI CSCD 北大核心 2023年第22期120-128,共9页
随着逆变型分布式电源(IIDG)高比例、灵活接入,传统的保护原理逐渐难以满足配电网的安全运行要求。与此同时,基于电力电子设备的主动探测思想提供了新思路。为此,充分利用电压源换流器的可控性,提出了适用于IIDG的谐波信号主动注入方法... 随着逆变型分布式电源(IIDG)高比例、灵活接入,传统的保护原理逐渐难以满足配电网的安全运行要求。与此同时,基于电力电子设备的主动探测思想提供了新思路。为此,充分利用电压源换流器的可控性,提出了适用于IIDG的谐波信号主动注入方法及其控制参数选取原则。然后,分析含T接IIDG配电网在区内外故障后所呈现的谐波电流故障特征,并揭示T接负荷分支对上述特征的影响规律,进而提出了一种基于谐波信号主动注入的含高比例IIDG配电网电流差动保护方案。最后,通过PSCAD/EMTDC仿真验证了所提方法的动作性能。测试结果表明,当存在T接分支时,所提方法仍能有效识别区内外故障,且无需额外的信号注入设备,经济性较好。 展开更多
关键词 配电网 分布式电源 谐波信号 主动注入 电流差动保护 T接分支
下载PDF
Comparison of Some Features of the Subtropical Countercurrent, the North Equatorial Current and the North Equatorial Countercurrent in the Northwest Pacific Ocean
12
作者 Sun Xiangping(First Institute of Oceanography, SOA, Qingdao) 《Marine Science Bulletin》 CAS 1999年第2期45-58,共14页
Based on the data of temperature and salinity of the 137°E section in the winters and summers from 1967 to 1995, the geo-strophic current of the section is calculated and analyzed, and the drifting tracks of the ... Based on the data of temperature and salinity of the 137°E section in the winters and summers from 1967 to 1995, the geo-strophic current of the section is calculated and analyzed, and the drifting tracks of the satellite tracking drift buoy distributed on the 144°E section are also analyzed. In light of the surface dynamic height distribution in the CSK atlas, this paper compares some features of the Subtropical Countercurrent, the North Equatorial Current and the North Equatorial Countercurrent. The main results are as follows:1. The Subtropical Countercurrent, the North Equatorial Current and the North Equatorial Countercurrent are not simple single currents, but have two branches or more. One of the common features of the three currents mentioned above is "multi-branching" of the current.2. The zonal distribution of the flow velocity structure, the alternate and intermittent occurrence of the eastward and westward flows, with a shallower flow layer and belonging to the surface flow or subsurface 展开更多
关键词 the SUBTROPICAL Countercurrent the NORTH EQUATORIAL current the NORTH EQUATORIAL Countercurrent multi-branching ZONAL structure
下载PDF
并联锂离子电池组建模及不均衡电流分析 被引量:2
13
作者 王开让 刘辉 +3 位作者 邹乃鹏 张彩萍 董建明 刘迪 《全球能源互联网》 CSCD 2023年第2期179-185,共7页
近年来电池储能以其响应速度快、能量密度高等优点,在电力系统中发挥重要作用。为满足实际应用的要求,电池储能系统需要将电池或电池组并联从而达到较高的可用容量,但并联电池在实际中受内阻、容量、荷电状态(SOC)等影响将出现电流不平... 近年来电池储能以其响应速度快、能量密度高等优点,在电力系统中发挥重要作用。为满足实际应用的要求,电池储能系统需要将电池或电池组并联从而达到较高的可用容量,但并联电池在实际中受内阻、容量、荷电状态(SOC)等影响将出现电流不平衡现象,一定程度上制约了电池充放电电流和使用条件,影响了电池性能。针对并联电池组支路电流采集过程繁琐且状态估计复杂的情况,以电池的二阶等效电路为基础,结合回路电流法建立了并联电池组的仿真模型。模型能够根据锂电池的性能参数及状态方程实现并联支路电流的计算,进而估计并联电池组的状态,省去了对并联支路电流的检测环节。同时重点研究了并联电池组的支路不均衡电流现象,以磷酸铁锂电池为例,分析了并联电池组的充电特性。针对并联电池组的支路不均衡电流影响因素较为复杂、难以解耦的特性,采用控制变量法,通过模型详细分析了内阻、容量、初始SOC等因素对支路电流点的影响,为并联电池组的设计、成组优化及性能分析提供了参考。 展开更多
关键词 锂电池储能 并联电池组 回路电流 支路不均衡电流
下载PDF
面向含不可测分支配电线路不对称故障可靠辨识的负序电流比相保护判据 被引量:3
14
作者 肖澍昱 林湘宁 +2 位作者 魏繁荣 吴宇奇 李正天 《电工技术学报》 EI CSCD 北大核心 2023年第9期2435-2447,共13页
城市配电网的主动配电网特征日趋显著,含不可测分支结构的馈电线路大量增加。受上述特点影响,单端量保护性能显著降低。因此,对于特别重要的线路,亟待双端量保护来保证故障切除的可靠性和灵敏性。但是,分支电流的差动特性导致相量差动... 城市配电网的主动配电网特征日趋显著,含不可测分支结构的馈电线路大量增加。受上述特点影响,单端量保护性能显著降低。因此,对于特别重要的线路,亟待双端量保护来保证故障切除的可靠性和灵敏性。但是,分支电流的差动特性导致相量差动保护从原理上即不适用,而纵联距离保护和方向比较式纵联保护由于需要电压信息,在仅配置电流互感器的线路不具备实施条件。此外,电压和分支两因素的叠加使得上述保护的动作行为分析尤为困难。因此,有必要寻找新型纵联保护判据。该文充分考虑不可测分支的影响,提出了仅利用负序电流相位差这一不对称故障期间始终存在的故障分量来反映故障的思路,并构建了一种适用于这类配电网线路的负序电流比相判据。与现有含分支的幅值差动类保护相比,所提判据在安全性方面具有优势。在PSCAD/EMTDC中搭建10 kV配电网模型,设计多组仿真算例,对比验证了所提判据的有效性。 展开更多
关键词 负序电流比相判据 不可测分支 不对称故障 负序电流校核判据 有源配电网
下载PDF
北京市属公立医院党支部“双带头人”建设现状与策略探讨 被引量:1
15
作者 马蒙蒙 贾梦帆 +2 位作者 聂婉颖 童永胜 杨甫德 《中国卫生标准管理》 2023年第11期84-88,共5页
目的北京市属公立医院党支部“双带头人”建设对进一步加强党支部战斗堡垒作用和公立医院高质量发展具有重要意义。本文拟对北京市属公立医院党支部“双带头人”的建设现状进行调查,以期为新时代加强北京市属公立医院党支部“双带头人... 目的北京市属公立医院党支部“双带头人”建设对进一步加强党支部战斗堡垒作用和公立医院高质量发展具有重要意义。本文拟对北京市属公立医院党支部“双带头人”的建设现状进行调查,以期为新时代加强北京市属公立医院党支部“双带头人”建设提供参考。方法于2022年11—12月从北京市属19家公立医院中每家随机抽取10名党支部书记针对党支部“双带头人”的现状进行问卷调查,并对推进中存在的问题进行分析,同时提出相关优化建议。结果共发放问卷190份,回收有效问卷174份。“双带头人”一肩挑的占比为86.96%;年龄主要集中在36~55岁;43.10%为高级职称;研究生学历占比为53.44%。28.99%的被调查者对“双带头人”机制了解较少;7.25%的人认为党建工作占用工作时间或可有可无;20.29%的被调查者对党建工作能力感到恐慌;50.72%的被调查者认为“双带头人”的身份与职务晋升、职称评聘、评优评先等联系不紧密。党支部工作开展中存在的主要问题是:工作难以创新突破、党建经费使用限制过多和业务工作压力大。结论北京市属公立医院党支部“双带头人”队伍是一支年轻化的、学历和职称层次较高的队伍。在推进过程中尚存在思想意识水平不足、履职能力有待进一步提升和考核机制不完善等问题。需要进一步加强和理顺。 展开更多
关键词 北京市属公立医院 党支部 党建 双带头人 现状 策略
下载PDF
基于改进定阶法的海底电缆绝缘状态诊断研究
16
作者 于是乎 林思衍 +5 位作者 吴吉 陈祎林 余欣 周凯 陈宇慧 李银格 《广东电力》 2023年第11期130-137,共8页
为了解决极化-去极化电流法在目前海底电缆绝缘诊断中支路辨识易受噪声干扰的问题,基于信息熵理论提出一种改进的支路辨识定阶方法。首先分析导致传统支路辨识方法在噪声环境下定阶不够准确的理论原因,之后利用信息熵理论对奇异值所带... 为了解决极化-去极化电流法在目前海底电缆绝缘诊断中支路辨识易受噪声干扰的问题,基于信息熵理论提出一种改进的支路辨识定阶方法。首先分析导致传统支路辨识方法在噪声环境下定阶不够准确的理论原因,之后利用信息熵理论对奇异值所带信息进行阶数确定,最后分别对实验室新电缆以及水树老化电缆运用该方法进行绝缘支路辨识。结果表明:水树老化缺陷的存在导致电荷在电缆的去极化过程中的弛豫时间与其他极化形式不同,最终使得支路数增加。改进定阶法在对水树老化电缆进行支路辨识时,能够更为准确地辨识出水树老化对应的极化支路,验证了所提方法的有效性,并为海底电缆绝缘状态诊断提供参考。 展开更多
关键词 海底电缆 绝缘诊断 极化-去极化电流法 支路辨识 信息熵
下载PDF
基于断路器支路故障电流的短路电流评估方法 被引量:1
17
作者 董炜 华文 +3 位作者 申屠磊璇 周靖皓 王龙飞 王博文 《浙江电力》 2023年第2期26-34,共9页
随着负荷快速增长,电网密度不断提升,短路电流超标问题日益严重,精确评估系统短路电流水平对保障电网的安全稳定运行至关重要。对此,提出一种基于断路器支路故障电流的短路电流评估方法。针对220 kV及以下电压等级双母双分段接线变电站... 随着负荷快速增长,电网密度不断提升,短路电流超标问题日益严重,精确评估系统短路电流水平对保障电网的安全稳定运行至关重要。对此,提出一种基于断路器支路故障电流的短路电流评估方法。针对220 kV及以下电压等级双母双分段接线变电站和500 kV 3/2接线变电站,分析不同故障位置、断路器拉停等情况下流过断路器的短路电流,并提出线路出口单相故障单跳单重阶段断路器所需遮断短路电流的计算方法,明确了变电站内断路器所需遮断最大短路电流,将短路电流校核标准精准化到故障后流过各断路器的最大短路电流不超过其遮断能力。最后通过算例分析验证了所提评估方法的有效性。 展开更多
关键词 短路电流 断路器支路 双母双分段接线 3/2接线 单相重合闸
下载PDF
幅值步进的电流波形对3D-AAO结构的影响
18
作者 张晶 徐芹 +2 位作者 肖永娜 殷晓广 段苏田 《有色金属工程》 CAS 北大核心 2023年第8期16-22,共7页
阳极氧化过程中使用不同的电流波形可以调制阳极氧化铝(AAO)多孔结构。使用电流幅值逐渐增加的改良间断锯齿状脉冲在磷酸电解液中对铝片进行脉冲阳极氧化,制备了孔径和周期长度都逐渐增加的3D-AAO纳米孔结构。通过改变幅值步进(ΔI)和... 阳极氧化过程中使用不同的电流波形可以调制阳极氧化铝(AAO)多孔结构。使用电流幅值逐渐增加的改良间断锯齿状脉冲在磷酸电解液中对铝片进行脉冲阳极氧化,制备了孔径和周期长度都逐渐增加的3D-AAO纳米孔结构。通过改变幅值步进(ΔI)和周期时间(T)可以精确控制3D-AAO纳米孔的几何结构。结果表明,随着ΔI的增加,得到了三种不同的纳米孔结构,且周期结构调制越来越明显。通过改变T,发现若T太小,则不足以形成与电流波形形状对应的微观结构。随着T的增大,会出现周期内分层的“Y”型分支纳米孔结构,且可能在一个周期内出现两个分支。分支长度随着电流幅值的增加而增加。通过分析阳极氧化电压-时间(U-T)图像发现,一个周期内氧化电压有两个极大值和极小值,极大值和极小值的比值决定了一个周期纳米孔的分支个数。这些新颖和定制的纳米结构可以广泛应用于光子晶体、药物传递,传感等领域。 展开更多
关键词 3D-AAO 改良间断锯齿状脉冲 电流幅值步进 周期时间 分支结构
下载PDF
中国特有植物青檀可培养内生真菌组成的季节性变化
19
作者 柴新义 赵鹏 +2 位作者 于士军 孙星 向玉勇 《西北林学院学报》 CSCD 北大核心 2023年第5期170-175,共6页
为了解不同季节青檀枝条中可培养内生真菌菌群的组成特征及其随季节更替的演变关系,采用组织分离与形态学鉴定的方法对采自不同季节的1年生青檀健康枝条进行内生真菌的分离和鉴定。从春、夏、秋、冬4个季节的1200个组织块中共分离内生真... 为了解不同季节青檀枝条中可培养内生真菌菌群的组成特征及其随季节更替的演变关系,采用组织分离与形态学鉴定的方法对采自不同季节的1年生青檀健康枝条进行内生真菌的分离和鉴定。从春、夏、秋、冬4个季节的1200个组织块中共分离内生真菌1120株,除未产孢类菌群占7.77%外,其余为子囊菌门和毛霉菌门种类,隶属2门8纲9目10科12属。结果表明,优势菌群会伴随着季节更替而发生演变。春季以毛霉菌纲、毛霉目、毛霉科、共头霉属为第一优势菌群(占35.31%);夏、秋2个季节以粪壳菌纲、肉座菌目、间座菌科、拟茎点霉属的菌群占比为最高(35.90%和29.78%);而冬季则以散囊菌纲、散囊菌目、发菌科、青霉属为最高(40.48%)。内生真菌的菌群组成随季节更替的演化关系既表现出季节延续性,又表现出季节特异性。在春、夏、秋、冬4个季节的植物样本中均出现的内生真菌菌群占33.33%,而丝孢纲、丛梗孢目、暗色孢科、枝孢属仅在春季出现;黑痣菌目、小丛壳科、刺盘孢属仅在秋季出现;曲霉属和孔球孢属则出现在春季和冬季。内生真菌菌群多样性伴随着季节的更替表现出先高(春)、后低(夏)、再高(秋)、再低(冬)的变化规律。 展开更多
关键词 青檀 当年生枝条 可培养内生真菌 菌群组成 季节性变化
下载PDF
铝电解槽带电焊接过程控制专家系统
20
作者 周小淞 黄若愚 颜非亚 《轻金属》 北大核心 2023年第6期59-62,共4页
通过电热信号监测系统,采集铝电解槽各短路母线和大电流多级变阻装置的电流数据,基于毕奥-萨法尔定律,可模拟并总结出单一状态下目标施焊区域的磁场矢量,以及随大电流多级变阻装置组的电流变化规律,从而得到此状态下施焊区域最优降磁效... 通过电热信号监测系统,采集铝电解槽各短路母线和大电流多级变阻装置的电流数据,基于毕奥-萨法尔定律,可模拟并总结出单一状态下目标施焊区域的磁场矢量,以及随大电流多级变阻装置组的电流变化规律,从而得到此状态下施焊区域最优降磁效果的控制电流组合,将所有状态关联并组合,最终形成带电焊接全过程控制专家系统。 展开更多
关键词 目标施焊区 分步降磁 大电流多级变阻 各通流支路控制电流组合
下载PDF
上一页 1 2 13 下一页 到第
使用帮助 返回顶部