Can pH Monitoring Predict Gastric Emptying Measured by <sup>13</sup>C-Acetate Breath Test in Gastroesophageal Reflux with Neurological Impairment?
1
作者 Tadao Okada Shohei Honda +2 位作者 Hisayuki Miyagi Masashi Minato Akinobu Taketomi 《Surgical Science》 2014年第1期20-24,共5页
Introduction: Delayed gastric emptying (DGE) often occurs in patients with gastroesophageal reflux (GER) due to neurological impairment (NI). 13C has been used as an alternative tool for measuring the gastric emptying... Introduction: Delayed gastric emptying (DGE) often occurs in patients with gastroesophageal reflux (GER) due to neurological impairment (NI). 13C has been used as an alternative tool for measuring the gastric emptying rates. The aim of this study was to predict gastric emptying in children with GER using 13C-acetate breath test (ABT) by 24-hour pH monitoring. Methods: Nineteen patients were divided into 2 groups: a DGE group with NI (14 patients), and normal-emptying group without NI (5 patients). The liquid test meal consisted of RacolTM (5 ml/kg) mixed with 13C-acetate (50 mg for infants, 100 mg for children, and 150 mg for adolescents). 13CO2 was measured using a gas chromatograph-isotope ratio mass spectrometer. The results are expressed as the % of 13C expired per hour and cumulative 13C excretion over a 3-hour periods including the parameters of half excretion and lag time. Results: The mean half excretion time was 1.762 hour in the DGE group and 1.095 hour in the normal-emptying group (P = 0.0196). The mean lag time was 0.971 hour in the DGE group and 0.666 hour in the normal-emptying group (P = 0.0196). Therefore, DGE was significantly more prevalent in the DGE compared to the normal-emptying group. The percentage of the time when the pH was less than 4 on 24-hour esophageal pH monitoring was 21.6% ± 9.2% in the DGE group and 28.5% ± 11.6% in the normal-emptying group (P = 0.4634). Conclusion: The percentage of time when the pH is less than 4 on 24-hour pH monitoring cannot predict DGE measured by the 13C-ABT in GER. 展开更多
关键词 Delayed Gastric EMPTYING GASTROESOPHAGEAL REFLUX NEUROLOGICAL Impairment 13C-Acetate breath Test 24-Hour pH monitoring
下载PDF
一种基于石英晶体微天平倍频相移信号的呼吸频率监测系统
2
作者 邓如悦 司士辉 +3 位作者 陈金华 王桢昌 贾胜彬 张汶铮 《传感技术学报》 CAS CSCD 北大核心 2024年第6期1078-1083,共6页
对人体呼吸频率实时连续的监测具有重要的医学诊断价值,本研究以基频10 MHz压电石英晶体为呼吸监测传感元件,采用直接数字频率合成器(DDS)合成频率源在5倍频下激励压电石英体,实时连续测定呼吸气流下的压电石英晶体相移变化信号。由于... 对人体呼吸频率实时连续的监测具有重要的医学诊断价值,本研究以基频10 MHz压电石英晶体为呼吸监测传感元件,采用直接数字频率合成器(DDS)合成频率源在5倍频下激励压电石英体,实时连续测定呼吸气流下的压电石英晶体相移变化信号。由于高倍频下压电石英体对表面水分子吸附聚集过程具有高灵敏的质量响应,因此石英体表面不需厚膜修饰,直接采用金属电极(银电极)的石英体,成功实现了对呼吸频率的连续监测。与传统的频移法相比,该方法信号采样速度快,可低至0.05 s/点,无论对慢呼吸还是急促呼吸都可以实现准确监测。石英晶体微天平相移呼吸检测系统不仅能够满足连续呼吸监测的要求,还可以为人体呼吸监测提供呼吸频率、呼吸强弱,呼吸紊乱度等呼吸特征信息。 展开更多
关键词 石英晶体微天平 传感器 呼吸监测 相位响应
下载PDF
基于TPU/CB/PA导电纱线的柔性传感器的制备与性能
3
作者 阳腾 胡文江 +3 位作者 丁伟乐 孙志慧 于晖 黄明华 《五邑大学学报(自然科学版)》 CAS 2024年第3期67-72,共6页
为提高镀银尼龙纱线制备的柔性传感器的环境稳定性,提升传感器集成于服装的效率,本文提出新的设计理念:基于同轴湿法纺丝技术制得以尼龙(PA)纱线为芯层、聚氨酯(TPU)和炭黑(CB)复合材料为皮层的芯鞘结构的TPU/CB/PA导电纱线,使用此导电... 为提高镀银尼龙纱线制备的柔性传感器的环境稳定性,提升传感器集成于服装的效率,本文提出新的设计理念:基于同轴湿法纺丝技术制得以尼龙(PA)纱线为芯层、聚氨酯(TPU)和炭黑(CB)复合材料为皮层的芯鞘结构的TPU/CB/PA导电纱线,使用此导电纱线在成品弹性带上缝制方波形、锯齿形两种重复图形,制备5种柔性应变传感器.文章探究了缝制图形的图案、数量、图形间距等参数对传感器性能的影响,结果表明:图案数量增加能提升传感器的稳定性和灵敏度;方波形传感器的稳定性优于锯齿形的;2#传感器样品在0%~10%应变内有良好的线性度和稳定性,具有呼吸监测的潜力. 展开更多
关键词 应变传感器 平缝 湿法纺丝 呼吸监测
下载PDF
肺气肿对阻塞性睡眠呼吸暂停综合征患者睡眠呼吸监测指标的影响
4
作者 廖秀枝 吴凯钦 陈清妹 《世界睡眠医学杂志》 2024年第5期1181-1183,共3页
目的:探讨合并肺气肿对阻塞性睡眠呼吸暂停综合征(OSAS)患者睡眠呼吸监测指标的影响。方法:选取2022年4月至2023年9月三明市第一医院收治的OSAS患者72例作为研究对象,按照是否合并肺气肿分为对照组和观察组,对照组为单纯OSAS患者不合并... 目的:探讨合并肺气肿对阻塞性睡眠呼吸暂停综合征(OSAS)患者睡眠呼吸监测指标的影响。方法:选取2022年4月至2023年9月三明市第一医院收治的OSAS患者72例作为研究对象,按照是否合并肺气肿分为对照组和观察组,对照组为单纯OSAS患者不合并肺气肿(n=41),观察组合并肺气肿(n=31),采用多导睡眠呼吸监测器监测2组患者的睡眠呼吸情况,并比较睡眠呼吸监测指标,比较2组患者的肺功能指标水平,比较2组患者睡眠状态下的血氧相关指标,比较2组患者睡眠质量。结果:观察组患者的睡眠监测指标均显著高于对照组,差异有统计学意义(P<0.05),观察组患者的FEV_(1)%、FEV_(1)/FVC以及TV均显著低于对照组,差异有统计学意义(P<0.05),观察组患者的血氧饱和度均显著高于对照组,差异有统计学意义(P<0.05),观察组最低80%以下氧饱和度次数和最低80%以下氧饱和度时间均显著低于对照组,差异有统计学意义(P<0.05),观察组患者的PSQI评分显著低于对照组,差异有统计学意义(P<0.05)。结论:合并肺气肿对OSAS患者的睡眠呼吸监测指标、肺功能指标以及血氧含量均会产生不良影响,临床上可针对合并疾病的患者及时作出治疗方案。 展开更多
关键词 肺气肿 阻塞性睡眠呼吸暂停综合征 睡眠呼吸监测 肺功能 血氧指标 睡眠呼吸暂停低通气指数 血氧饱和度 入睡潜伏期
下载PDF
基于LoRa的呼吸阀状态实时监测系统设计
5
作者 杨士达 李维军 《无线互联科技》 2024年第9期60-65,共6页
文章针对呼吸阀传统校验方式成本高昂和时效性不足的问题,设计了一种呼吸阀实时状态监测系统。通过监测呼吸阀超压泄放过程中腔内压力和阀盘位移的实时反映呼吸阀的工作状态,本系统实现呼吸阀的智能监测。系统以STM32F103VET6作为核心... 文章针对呼吸阀传统校验方式成本高昂和时效性不足的问题,设计了一种呼吸阀实时状态监测系统。通过监测呼吸阀超压泄放过程中腔内压力和阀盘位移的实时反映呼吸阀的工作状态,本系统实现呼吸阀的智能监测。系统以STM32F103VET6作为核心处理器并利用LoRa无线局域网实现状态数据的实时传输,同时通过4G网络方式实现呼吸阀与上位机之间的通信。实验结果显示,该系统可实现呼吸阀状态的主动监测,便于呼吸阀的运行管理与维护。 展开更多
关键词 LoRa模块 呼吸阀 STM32F103VET6 物联网 监控
下载PDF
老年人群24h动态血压监测中清晨高血压与脑血管储备功能相关性
6
作者 李蕴 宋云红 梁玉莲 《国际医药卫生导报》 2024年第10期1698-1702,共5页
目的研究老年人群24 h动态血压监测中清晨高血压与脑血管储备功能(CVR)的相关性。方法回顾性选取2021年1月至12月到济南市妇幼保健院行24 h动态血压监测的300例老年受试者,依据监测结果分为A组、B组和C组。A组158例为清晨血压升高的高... 目的研究老年人群24 h动态血压监测中清晨高血压与脑血管储备功能(CVR)的相关性。方法回顾性选取2021年1月至12月到济南市妇幼保健院行24 h动态血压监测的300例老年受试者,依据监测结果分为A组、B组和C组。A组158例为清晨血压升高的高血压患者,男88例,女70例,年龄(66.02±4.35)岁;B组74例为清晨血压正常的高血压患者,男41例,女33例,年龄(65.42±4.42)岁;C组68例为血压正常者,男37例,女31例,年龄(65.77±4.38)岁。以两侧大脑中动脉屏气指数均值<0.69%为CVR减低,屏气指数均值≥0.69%为CVR正常,将300例受试者分为CVR降低组(52例)和CVR正常组(248例)。比较A、B、C 3组患者的临床资料,CVR指标;比较CVR降低组、CVR正常组一般资料,行单因素分析、多因素分析和相关性分析。采用F检验、独立样本t检验、χ^(2)检验、logistic回归分析和Pearson相关性分析。结果300例24 h动态血压监测的老年受试者,清晨血压升高的高血压患者158例,占52.67%;清晨血压正常的高血压患者74例,占24.67%;血压正常者68例,占22.67%。3组收缩压(24 h均值、日间均值、夜间均值)、晨峰指数:A组>B组>C组(均P<0.05);舒张压(24 h均值、日间均值、夜间均值):A组>B组、C组(均P<0.05),B组、C组舒张压比较,差异均无统计学意义(均P>0.05)。CVR:A组[(21.37±7.89)%]<B组[(25.58±8.14)%]<C组[(28.56±8.10)%](均P<0.05);屏气指数:A组[(0.89±0.23)%]<B组[(1.13±0.21)%]、C组[(1.20±0.24)%](均P<0.05),B组、C组屏气指数比较,差异无统计学意义(P>0.05);脉动指数:A组[(1.49±0.36)]>B组[(1.15±0.31)]、C组[(1.06±0.29)](均P<0.05),B组、C组脉动指数比较,差异无统计学意义(P>0.05)。CVR降低组年龄[(73.14±3.21)岁]、清晨收缩压[(132.42±9.64)mmHg](1 mmHg=0.133 kPa)、清晨舒张压[(68.85±6.59)mmHg]均高于CVR正常组[(64.28±4.36)岁、(121.58±7.26)mmHg、(65.36±7.23)mmHg](均P<0.05)。logistic回归分析结果显示:年龄、清晨收缩压、清晨舒张压均为CVR降低的影响因素(均P<0.05)。清晨收缩压与屏气指数呈负相关(P<0.05),与脉动指数呈正相关(P<0.05);清晨舒张压与屏气指数呈负相关(P<0.05),与脉动指数呈正相关(P<0.05)。结论老年人群24 h动态血压监测中清晨高血压患者占比较大,清晨高血压患者CVR、屏气指数较低,脉动指数较高,清晨收缩压、清晨舒张压均与屏气指数呈负相关,与脉动指数呈正相关。 展开更多
关键词 24 h动态血压监测 清晨高血压 脑血管储备功能 屏气指数 脉动指数 清晨收缩压 清晨舒张压
下载PDF
不同补氮程度油品罐通过呼吸阀排放油气危险性研究
7
作者 张东许 李佳航 +1 位作者 多英全 吴宗之 《压力容器》 北大核心 2024年第4期43-52,共10页
在大型油品贮罐建设量增加的趋势下,针对内浮顶罐在不同补氮程度下形成的不同浓度的气相空间油气,通过呼吸阀排放时形成的爆炸性危险的研究尚显不足。采用Fluent模拟研究不同补氮程度下形成的气相空间油气,在不同风速下通过呼吸阀排放... 在大型油品贮罐建设量增加的趋势下,针对内浮顶罐在不同补氮程度下形成的不同浓度的气相空间油气,通过呼吸阀排放时形成的爆炸性危险的研究尚显不足。采用Fluent模拟研究不同补氮程度下形成的气相空间油气,在不同风速下通过呼吸阀排放时的爆炸危险性。结果表明,在罐底安装针对呼吸阀排放危险性的监测设备无法进行有效监测;外界风速在罐顶形成旋涡,在呼吸阀附近挤压作用明显,对呼吸阀排放出的油气起到加速扩散和稀释作用;在有无外界风干扰时,距离罐顶中心0.1 m处安装监测设备,均可以快速监测到气相空间内浓度为5%~100%的油气经过呼吸阀排放的爆炸危险性;罐内、外监测设备监测到危险性浓度后,应采取预防气相空间内形成危险性油气浓度、预防气相空间内形成可排放压力、防止危险性浓度的油气排放等措施,以进行综合治理。 展开更多
关键词 油品储罐 呼吸阀 补氮程度 气相空间 监测设备
下载PDF
呼吸训练器联合排痰仪对慢阻肺下呼吸道感染患者的影响
8
作者 梅娇娇 王克琴 徐娟 《现代科学仪器》 2024年第5期119-122,共4页
目的:呼吸训练器联合震荡排痰仪对慢阻肺伴急性下呼吸道感染患者的影响。方法:选取100例慢阻肺伴急性下呼吸道感染患者,按随机数字表法分为常规组50例(常规干预)与观察组50例(呼吸训练器联合震荡排痰仪),对比两组临床效果。结果:干预后... 目的:呼吸训练器联合震荡排痰仪对慢阻肺伴急性下呼吸道感染患者的影响。方法:选取100例慢阻肺伴急性下呼吸道感染患者,按随机数字表法分为常规组50例(常规干预)与观察组50例(呼吸训练器联合震荡排痰仪),对比两组临床效果。结果:干预后,观察组FVC、FEV1、PEF、PaO_(2)及生活质量等指标均高于常规组,PaCO_(2)、SAS、SDS等指标均低于常规组,差异有统计学意义(P<0.05)。结论:呼吸训练器联合震荡排痰仪可缓解慢阻肺伴急性下呼吸道感染患者的临床症状,改善血气分析指标和心理状态,促进肺功能康复。 展开更多
关键词 呼吸训练器 震荡排痰仪 慢性阻塞性肺病 急性下呼吸道感染 肺功能 心理状态
下载PDF
脑卒中后昼间嗜睡与患者睡眠呼吸障碍的相关性研究 被引量:3
9
作者 王文熠 陈光 《天津医药》 CAS 北大核心 2023年第12期1369-1373,共5页
目的探讨脑卒中后昼间嗜睡(EDS)与患者睡眠呼吸障碍的相关性。方法148例脑卒中患者依据Epworth嗜睡量表(ESS)分为EDS组(ESS>7分)69例和非EDS组(ESS≤7分)79例。比较2组患者的一般资料、血液生化及多导睡眠呼吸监测(PSG)相关指标,Spea... 目的探讨脑卒中后昼间嗜睡(EDS)与患者睡眠呼吸障碍的相关性。方法148例脑卒中患者依据Epworth嗜睡量表(ESS)分为EDS组(ESS>7分)69例和非EDS组(ESS≤7分)79例。比较2组患者的一般资料、血液生化及多导睡眠呼吸监测(PSG)相关指标,Spearman相关分析脑卒中后EDS与SDB发病率的相关性,二元多因素Logistic回归分析脑卒中后EDS的影响因素。结果EDS组男性比例、低通气指数(AHI)、氧减指数(ODI)、N1睡眠期比例、夜间平均舒张压高于非EDS组(P<0.05);卒中患者EDS和SDB的发病呈正相关性(rs=0.225,P<0.05);二元多因素Logistic回归分析结果显示,男性(OR=2.768,95%CI:1.133~6.765)、高AHI值(OR=1.048,95%CI:1.023~1.074)和夜间平均舒张压升高(OR=1.035,95%CI:1.001~1.071)是卒中后EDS的独立危险因素。结论男性、高AHI及夜间平均舒张压升高是脑卒中后EDS的独立危险因素。 展开更多
关键词 脑卒中 睡眠呼吸暂停综合征 影响因素 昼间嗜睡 多导睡眠呼吸监测
下载PDF
Continuous respiratory monitoring for sleep apnea screening by ambulatory hemodynamic monitor
10
作者 Roger Dillier Markus Baumann +4 位作者 Mabelle Young Susanne Erne Bernhard Schwizer Michel Zuber Paul Erne 《World Journal of Cardiology》 CAS 2012年第4期121-127,共7页
AIM:To validate the sleep-disordered breathing components of a portable electrocardiography and hemodynamic monitor to be used for sleep apnea screening.METHODS:Sleep-disordered breathing(SDB) is associated with cardi... AIM:To validate the sleep-disordered breathing components of a portable electrocardiography and hemodynamic monitor to be used for sleep apnea screening.METHODS:Sleep-disordered breathing(SDB) is associated with cardiovascular disease.Patients with existing cardiovascular disease may have unrecognized SDB or may develop SDB while under the care of a cardiologist.A screening device for SDB,easy to use and appealing to cardiologists,would assist in referral of appropriate patients for full polysomnography(PSG).A cardiac and respiratory monitor(CPAM) was attached to patients undergoing PSG and an apnea/hypopnea index(AHI) generated.The CPAM device produced respiration rate,snoring rate,individual apnea/hypopnea events and an SDB severity score(SDBSS).In addition to AHI,an expert over-reader annotated individual breaths,snores and SDB breathing events to which the automated algorithms were compared.RESULTS:The test set consisted of data from 85 patients(age:50.5 ± 12.4 years).Of these,57 had a positive PSG defined as AHI ≥ 5.0(mean:30.0 ± 29.8,negative group mean:1.5 ± 1.2).The sensitivity and specificity of the SDBSS compared to AHI was 57.9% and 89.3%,respectively.The correlation of snoring rate by CPAM compared to the expert overreader was r = 0.58(mean error:1.52 snores/min),while the automated respiration rate had a correlation of r = 0.90(mean error:0.70 breaths/min).CONCLUSION:This performance assessment shows that CPAM can be a useful portable monitor for screening and follow-up of subjects for SDB. 展开更多
关键词 Portable monitor Sleep-disordered breathing POLYSOMNOGRAPHY Sleep APNEA HEMODYNAMIC monitor
下载PDF
基于光学表面监测系统的深吸气屏气技术的全流程管理及应用
11
作者 孙文正 《医疗装备》 2023年第9期11-14,18,共5页
为提高基于光学表面监测系统(OSMS)的深吸气屏气(DIBH)技术的成功率,改善患者的治疗体验,该研究回顾了浙江大学医学院附属第二医院利用该技术治疗6例乳腺癌患者的全流程,并总结了相关的管理和应用经验,以期为同行提供参考。
关键词 放射治疗 光学表面监测系统 深吸气屏气技术 全流程管理
下载PDF
基于差分吸收检测技术的非分散红外CO_(2)呼吸气体传感器 被引量:16
12
作者 袁博 袁宇鹏 +5 位作者 张祖伟 杨靖 黄诗田 柯淋 张开盛 罗文博 《重庆邮电大学学报(自然科学版)》 CSCD 北大核心 2021年第1期118-125,共8页
采用非分散红外(non-dispersive infrared,NDIR)气体传感器实时检测呼吸气体中的CO_(2)气体浓度,进而反映人体运动机能和代谢功能等身体状态,可以满足人类日益增强的对自身健康状况进行了解的需求。利用电调制微机电系统(micro-electro-... 采用非分散红外(non-dispersive infrared,NDIR)气体传感器实时检测呼吸气体中的CO_(2)气体浓度,进而反映人体运动机能和代谢功能等身体状态,可以满足人类日益增强的对自身健康状况进行了解的需求。利用电调制微机电系统(micro-electro-mechanical system,MEMS)光源和双通道热释电传感器分别作为红外光源和探测器,采用气室结构设计和压电微泵相结合的方法为传感器提供稳定的气体流速,设计出红外呼吸CO2气体传感器。通过测量不同CO_(2)标准气体浓度下热释电传感器参考通道和测量通道的电压比值进行传感器标定,获得了在室温下、检测量程0%~8%内,绝对误差小于0.5%,相对误差3%,系统响应时间小于1.5 s的传感器,提高了基于NDIR气体传感器检测呼吸气体的抗干扰能力,可望满足运动机能和代谢功能检测等应用对CO_(2)气体监测的需求。 展开更多
关键词 CO_(2) 气体传感器 压电微泵 呼吸检测 差分检测
下载PDF
阻塞性睡眠呼吸暂停低通气综合征相关性高血压研究进展 被引量:18
13
作者 孙东升 徐少坤 +1 位作者 张丽 周宁 《中国医药》 2020年第10期1642-1645,共4页
睡眠呼吸紊乱与高血压之间的关系自20世纪70年代开始受到关注。此后的一系列研究发现,睡眠呼吸暂停或低通气与心血管的其他危险因素也密切相关,有着特殊的临床意义。在睡眠呼吸暂停或低通气中,又以阻塞性睡眠呼吸暂停低通气综合征(OSAHS... 睡眠呼吸紊乱与高血压之间的关系自20世纪70年代开始受到关注。此后的一系列研究发现,睡眠呼吸暂停或低通气与心血管的其他危险因素也密切相关,有着特殊的临床意义。在睡眠呼吸暂停或低通气中,又以阻塞性睡眠呼吸暂停低通气综合征(OSAHS)最为常见,很多高血压患者合并存在OSAHS。特别是在难治性高血压患者中,多数合并中重度的OSAHS。睡眠实验室中进行的多导睡眠图监测虽然是诊断睡眠呼吸紊乱或OSAHS的金标准,但是目前并不普及,难以对众多的高血压人群进行筛查。近年来便携式睡眠呼吸监测仪逐渐普及,充分利用该设备,对特定的高血压人群进行OSAHS筛查或确诊,制定合理的治疗方案,将有利于高血压的控制,进一步减少心脑血管并发症。 展开更多
关键词 睡眠呼吸紊乱 阻塞性睡眠呼吸暂停低通气综合征 高血压 睡眠呼吸监测
下载PDF
犬恩氟烷吸入麻醉的模型建立及麻醉监测 被引量:4
14
作者 孙荣钊 刘焕奇 《中国兽医杂志》 CAS 北大核心 2012年第10期22-24,共3页
应用吸入麻醉药恩氟烷对宠物犬进行麻醉试验,建立起宠物犬吸入麻醉的试验模型,同时对麻醉犬进行麻醉监测,探讨宠物犬恩氟烷理想的吸入麻醉方式。试验应用异丙酚2mg/kg体重肌肉注射实施诱导麻醉,以配合气管内插管。用1.6%浓度的恩氟烷维... 应用吸入麻醉药恩氟烷对宠物犬进行麻醉试验,建立起宠物犬吸入麻醉的试验模型,同时对麻醉犬进行麻醉监测,探讨宠物犬恩氟烷理想的吸入麻醉方式。试验应用异丙酚2mg/kg体重肌肉注射实施诱导麻醉,以配合气管内插管。用1.6%浓度的恩氟烷维持麻醉。麻醉期间应用监护仪进行呼吸、循环系统各项指标监测,同时对角膜、眼睑反射、瞳孔变化等进行实时监测。结果表明,恩氟烷对小型观赏犬进行麻醉,恩氟烷浓度为1.6%,即0.7MAC时,诱导迅速、苏醒快、效果好,易于维持和控制麻醉深度,安全范围大。 展开更多
关键词 恩氟烷 呼吸麻醉 循环 呼吸 监测
下载PDF
测定患者呼吸功对调整压力支持通气水平的意义 被引量:3
15
作者 邱海波 刘晓岩 +2 位作者 杜斌 刘大为 陈德昌 《中国危重病急救医学》 CAS CSCD 1997年第1期33-35,共3页
目的:评价患者呼吸功(WOBp)对调整压力支持通气(PSV)水平的意义。方法:观测不同水平PSV时,WOBp、呼吸机做功(WOBv)及呼吸频率(RR)、潮气量(VT)等指标的变化。结果:随PSV水平增高,WOBp逐渐... 目的:评价患者呼吸功(WOBp)对调整压力支持通气(PSV)水平的意义。方法:观测不同水平PSV时,WOBp、呼吸机做功(WOBv)及呼吸频率(RR)、潮气量(VT)等指标的变化。结果:随PSV水平增高,WOBp逐渐降低,WOBv逐渐增高;PSV0时,WOBp为1.22±0.47J/L,PSV在1.47kPa时,WOBp和WOBv分别为0.38±0.31J/L和1.29±0.14J/L;WOBp与PSV水平呈负相关(r=0.993;P<0.05),WOBv与PSV水平呈正相关(r=0.999,P<0.05);RR随PSV增高而仅从22.0次/分降至17.2次/分,VT仅从0.36L增至0.49L。结论:随PSV支持水平的提高,WOBp逐渐降低,以WOBp水平指导PSV水平的调整,比RR、VT等常规监测指标更有意义。 展开更多
关键词 机械通气 压力支持通气 呼吸监测 呼吸功
下载PDF
氧流量对可用于监测呼吸频率吸氧管监测效果的影响 被引量:3
16
作者 刘海健 徐志勇 翁浩 《上海医学》 CAS CSCD 北大核心 2016年第6期356-358,共3页
目的探讨吸入不同氧流量对可用于监测呼吸频率吸氧管监测效果的影响。方法选择在椎管内麻醉下行下肢手术的患者270例,年龄18~60岁,体重55~85kg,美国麻醉医师协会分级I或Ⅱ级。采用随机数字表法将患者分为对照组、研究1组、研究2组... 目的探讨吸入不同氧流量对可用于监测呼吸频率吸氧管监测效果的影响。方法选择在椎管内麻醉下行下肢手术的患者270例,年龄18~60岁,体重55~85kg,美国麻醉医师协会分级I或Ⅱ级。采用随机数字表法将患者分为对照组、研究1组、研究2组、研究3组、研究4组、研究5组共6组,每组45例。所有患者行椎管内麻醉后取平卧位,接鼻氧管吸氧,研究1组、研究2组、研究3组、研究4组和研究5组的氧气流量分别为1、2、3、4、5L/min,对照组只接鼻氧管不吸氧气。20min后,通过吸氧管的二氧化碳采集端连接麻醉监护仪,采集患者的呼吸频率和呼气末二氧化碳分压(petCO2),同时记录脉搏血氧饱和度(SpO2)。经桡动脉取动脉血进行血气分析检测动脉血氧分压(paCO2)和二氧化碳分压(paCO2),同时目测计数患者的呼吸频率。结果各研究组的SpO2和PaO2均显著高于对照组(P值均〈0.05),研究2组、研究3组、研究4组、研究5组的PetCO2均显著低于对照组(P值均〈0.05),研究3组、研究4组、研究5组监护仪测得的呼吸频率均显著低于对照组(P值均〈0.05)。研究3组、研究4组、研究5组的PetCO2显著低于同组paCO2(P值均〈0.05),研究4组、研究5组监护仪测得的呼吸频率显著低于同组目测计数的呼吸频率(P值均〈0.05)。结论应用可用于监测呼吸频率吸氧管吸氧时,给予3L/min氧气流量,麻醉监护仪可准确监测患者的呼吸频率。 展开更多
关键词 呼吸频率 监测 氧气流量 自主呼吸
下载PDF
基于PVDF的汽车驾驶员心电呼吸监测系统研究 被引量:2
17
作者 曹景胜 石晶 +2 位作者 李刚 郭银景 单鹏 《现代电子技术》 北大核心 2019年第10期79-82,87,共5页
汽车驾驶员疲劳驾驶是引发交通事故的重要原因之一,根据心电呼吸等生理参数评估驾驶员疲劳程度成为研究热点。基于PVDF压电薄膜的非接触特性和正压电效应,研究并实现了汽车驾驶员心电呼吸监测系统。硬件部分设计了稳定的信号调理和滤波... 汽车驾驶员疲劳驾驶是引发交通事故的重要原因之一,根据心电呼吸等生理参数评估驾驶员疲劳程度成为研究热点。基于PVDF压电薄膜的非接触特性和正压电效应,研究并实现了汽车驾驶员心电呼吸监测系统。硬件部分设计了稳定的信号调理和滤波去噪电路,软件部分构建了准确的心跳和呼吸信号分离算法。测试分析表明,系统能稳定可靠地监测心率和呼吸率,有效地预防疲劳驾驶带来的后果,提高汽车行驶安全性。 展开更多
关键词 汽车驾驶员 疲劳驾驶 PVDF 心电呼吸 正压电效应 监测系统
下载PDF
呼气中痕量挥发性有机物的质子转移反应质谱在线检测研究 被引量:15
18
作者 沈成银 李建权 +6 位作者 王宏志 志中华 王鸿梅 黄超群 刘升 江海河 储焰南 《分析化学》 SCIE CAS CSCD 北大核心 2012年第5期773-777,共5页
通过对自主研制的大气成分在线检测质子转移反应质谱的进样管路系统进行改造,建立了可在线检测呼气中痕量挥发性有机物的质子转移反应质谱装置。通过对呼气进样系统的旁路流量控制,实现对进样速度的调控,既可提高进样速度,以满足实时监... 通过对自主研制的大气成分在线检测质子转移反应质谱的进样管路系统进行改造,建立了可在线检测呼气中痕量挥发性有机物的质子转移反应质谱装置。通过对呼气进样系统的旁路流量控制,实现对进样速度的调控,既可提高进样速度,以满足实时监测呼气中指定成分浓度变化;也可适时关闭旁路,以降低进样速度,从而对呼气成分进行全谱分析,避免采样袋采样和浓缩的复杂程序和潜在干扰。以作者呼出气体作为研究对象,对装置性能进行测试,结果表明:装置最快响应时间可达1s,对呼气中丙酮的探测灵敏度高达每10-9(V/V)浓度的信号强度为14.6counts/s,多次呼气测量重复性好,有望广泛应用于呼气疾病诊断研究。 展开更多
关键词 呼气 挥发性有机物 实时监测 质子转移反应质谱 在线质谱
下载PDF
全程无缝隙护理模式对初产妇分娩结局的影响 被引量:38
19
作者 吕春香 闵悦 +2 位作者 李冬 魏敏 于伟 《长春中医药大学学报》 2019年第6期1171-1174,共4页
目的研究全程无缝隙护理模式对初产妇分娩结局的临床应用效果。方法随机选取我院2016年6月-2017年6月拟行自然分娩的初产妇260例,采用电脑随机选取的方式将其分为观察组和对照组,各130例。对照组采取产科常规分娩护理措施联合拉玛泽呼吸... 目的研究全程无缝隙护理模式对初产妇分娩结局的临床应用效果。方法随机选取我院2016年6月-2017年6月拟行自然分娩的初产妇260例,采用电脑随机选取的方式将其分为观察组和对照组,各130例。对照组采取产科常规分娩护理措施联合拉玛泽呼吸法,观察组在对照组基础上采取全程无缝隙护理模式,全面评价应用效果,对2组初产妇分娩方式、母乳喂养率、产后2 h出血量、新生儿1 min阿普加评分及自然分娩总产程进行对比分析。结果观察组初产妇的自然分娩率、新生儿1 min阿普加评分和母乳喂养率明显高于对照组(P<0.05);观察组初产妇自然分娩的总产程和产后2 h出血量明显低于对照组(P<0.05)。结论实施全程无缝隙护理模式对初产妇分娩质量的提高呈正相关,可显著缩短总产程耗时,自然分娩中的疼痛减轻,从而使自然分娩率明显提高,剖宫产率显著降低,产后出血量明显减少,提高新生儿阿普加评分,临床应用价值高。 展开更多
关键词 全程无缝隙护理模式 导乐分娩 孕期体重管理软件 分娩监护镇痛仪 拉玛泽呼吸法
下载PDF
高原地区心脏体外循环术后呼吸机治疗的监护
20
作者 张伟英 顾晖 +1 位作者 赵继军 马楚云 《护士进修杂志》 北大核心 2003年第1期40-41,共2页
通过对 2 8例在高原地区施行的心脏直视术后患者呼吸机治疗的监护 ,认为高原地区心脏手术后给予人工辅助呼吸比平原地区更为必要 ,可提供高氧环境 ,促进呼吸和心脏功能的恢复 ,减少术后并发症的发生 ,由此提高手术成功率。但术后早期呼... 通过对 2 8例在高原地区施行的心脏直视术后患者呼吸机治疗的监护 ,认为高原地区心脏手术后给予人工辅助呼吸比平原地区更为必要 ,可提供高氧环境 ,促进呼吸和心脏功能的恢复 ,减少术后并发症的发生 ,由此提高手术成功率。但术后早期呼吸机治疗必须在严密的监护下进行 ,要求护理人员 :(1)做好患者入ICU即刻呼吸机使用的准备 ;(2 )根据病情调节呼吸机各参数 ,合理使用PEEP ;(3)严密观察各临床指标 ;(4)对于肺动脉高压患者施行相应的呼吸机治疗处理 ;(5 ) 展开更多
关键词 高原地区 体外循环 心脏手术 呼吸机 监护
下载PDF
上一页 1 2 4 下一页 到第