Clay brick masonry unit(CBMU) walls are widely used in building structures,and its damage and protection under explosion loads have been a matter of concern in the field of engineering protection.In this paper,a serie...Clay brick masonry unit(CBMU) walls are widely used in building structures,and its damage and protection under explosion loads have been a matter of concern in the field of engineering protection.In this paper,a series of full-scale experiments of the response characteristics of 24 cm CMBU walls unreinforced and reinforced with polyurea elastomer subjected to blast loading were carried out.Through setting 5.0 kg TNT charges at different stand-off distances,the damage characteristics of masonry walls at different scaled distances were obtained.The reinforcement effect of different polyurea coating thicknesses and methods on the blast resistance performance of masonry walls under single and repeated loads were also explored.Five failure grades were summarized according to the dynamic response features of masonry walls.Based on the stress wave propagation pattern in multi-media composite structures,the internal stress distribution of masonry walls were analyzed,and the division basis of the masonry walls’ failure grades was then quantified.Combined with Scanning Electron Microscope(SEM)images,the deformation characteristics of soft and hard segments of polyurea and effects of detonation products on microstructures were revealed respectively,which provides an important reference for the design and application of polyurea in the blast resistance of clay brick masonry walls.展开更多
This paper presents an experimental investigation on the flexural behavior of cross-connected brick masonry infill wall panels supported on reinforced concrete beam grids above and below the walls.The experimental pro...This paper presents an experimental investigation on the flexural behavior of cross-connected brick masonry infill wall panels supported on reinforced concrete beam grids above and below the walls.The experimental program was comprised of six wall systems.The effect of change in lower beam stiffness relative to the wall and the geometry of the main walls were investigated.From the results of the experimental tests,the increase in the depth of the lower beam grid reduces the deflection,resulting in an increase in the load carrying capacity of the wall.Further,the stiffness of the main walls affects the deflection and the failure load of the cross walls.展开更多
基金supported by the National Natural Science Foundation of China nos.51978660。
文摘Clay brick masonry unit(CBMU) walls are widely used in building structures,and its damage and protection under explosion loads have been a matter of concern in the field of engineering protection.In this paper,a series of full-scale experiments of the response characteristics of 24 cm CMBU walls unreinforced and reinforced with polyurea elastomer subjected to blast loading were carried out.Through setting 5.0 kg TNT charges at different stand-off distances,the damage characteristics of masonry walls at different scaled distances were obtained.The reinforcement effect of different polyurea coating thicknesses and methods on the blast resistance performance of masonry walls under single and repeated loads were also explored.Five failure grades were summarized according to the dynamic response features of masonry walls.Based on the stress wave propagation pattern in multi-media composite structures,the internal stress distribution of masonry walls were analyzed,and the division basis of the masonry walls’ failure grades was then quantified.Combined with Scanning Electron Microscope(SEM)images,the deformation characteristics of soft and hard segments of polyurea and effects of detonation products on microstructures were revealed respectively,which provides an important reference for the design and application of polyurea in the blast resistance of clay brick masonry walls.
文摘This paper presents an experimental investigation on the flexural behavior of cross-connected brick masonry infill wall panels supported on reinforced concrete beam grids above and below the walls.The experimental program was comprised of six wall systems.The effect of change in lower beam stiffness relative to the wall and the geometry of the main walls were investigated.From the results of the experimental tests,the increase in the depth of the lower beam grid reduces the deflection,resulting in an increase in the load carrying capacity of the wall.Further,the stiffness of the main walls affects the deflection and the failure load of the cross walls.