The brushless doubly-fed wind power system based on conventional power control strategies lacks ‘inertia’ and the ability to support grid,which leads to the decline of grid stability.Therefore,a control strategy of ...The brushless doubly-fed wind power system based on conventional power control strategies lacks ‘inertia’ and the ability to support grid,which leads to the decline of grid stability.Therefore,a control strategy of brushless doubly-fed reluctance generator(BDFRG) based on virtual synchronous generator(VSG) control is proposed to solve the problem in this paper.The output characteristics of BDFRG based on VSG are similar to a synchronous generator(SG),which can support the grid frequency and increase the system ‘inertia’.According to the mathematical model of BDFRG,the inner loop voltage source control of BDFRG is derived.In addition,the specific structure and parameter selection principle of outer loop VSG control are expounded.The voltage source control inner loop of BDFRG is combined with the VSG control outer loop to establish the overall architecture of BDFRG-VSG control strategy.Finally,the effectiveness and feasibility of the proposed strategy are verified in the simulation.展开更多
The aim of this paper is to investigate an adaptive sensorless direct voltage control(DVC)strategy for the stand-alone ship shaft brushless doubly-fed induction generators(BDFIGs).The proposed new rotor position obser...The aim of this paper is to investigate an adaptive sensorless direct voltage control(DVC)strategy for the stand-alone ship shaft brushless doubly-fed induction generators(BDFIGs).The proposed new rotor position observer using the space vector flux relations of BDFIG may achieve the desired voltage control of the power winding(PW)in terms of magnitude and frequency,without any speed/position sensors.The proposed algorithm does not require any additional observers for obtaining the generator speed.The proposed technique can directly achieve the desired DVC based on the estimated rotor position,which may reduce the overall system cost.The stability analysis of the proposed observer is investigated and confirmed with the concept of quadratic Lyapunov function and using the multi-model representation.In addition,the sensitivity analysis of the presented method is confirmed under different issues of parameter uncertainties.Comprehensive results from both simulation and experiments are realized with a prototype wound-rotor BDFIG,which demonstrate the capability and efficacy of the proposed sensorless DVC strategy with good transient behavior under different operating conditions.Furthermore,the analysis confirms the robustness of the proposed observer via the machine parameter changes.展开更多
VFT (variable frequency transformer) has been recently used as art alternative to HVDC (high voltage direct current) to control power flow between asynchronous networks. VFT consumes less reactive power than a bac...VFT (variable frequency transformer) has been recently used as art alternative to HVDC (high voltage direct current) to control power flow between asynchronous networks. VFT consumes less reactive power than a back-to-back HVDC system, provides faster initial transient recovery, and has better natural damping capability. VFT is simply a DFIM (doubly-fed induction machine) where the machine torque controls the power flow from stator to rotor and vice versa. The main disadvantage of this VFT is the slip rings and brushes required for the rotor circuit, especially in bulk power transmission. The BDFM (brushless doubly-fed machine) with nested cage rotor machine is proved to be a comparable alternative to conventional DFIM in many applications with the advantage that all windings being in the stator frame with fixed output terminals. In this paper, the BDFM is used as a BVFT (brushless variable frequency transformer). A prototype machine is designed and simulated to verify the system validity.展开更多
Brushless Doubly-Fed Machine has attracted considerable attention in recent years due to its advantages. It has the robustness of the squirrel cage induction machine, and the speed and power factor controllability of ...Brushless Doubly-Fed Machine has attracted considerable attention in recent years due to its advantages. It has the robustness of the squirrel cage induction machine, and the speed and power factor controllability of the synchronous machine as well as the absence of brushes and slip rings, and using a fractionally rated frequency converter. Hence, there are considerable benefits over the conventional machines, when the machine is applied to applications such as a wind turbine generator or high power adjustable speed drive. However, these benefits are obtained in slightly more complex structure, higher cost and larger dimensions in comparison to the conventional induction machine. This paper presents fundamental aspects of the three modes of operation of brushless doubly fed machine, i.e. simple induction mode, cascade induction mode, and synchronous mode. The investigation is performed by analyzing the spatial harmonic contents of the rotor magnetic flux density. The direct cross couplings between stator and rotor fields as well as, indirect cross coupling between stator fields by the special rotor of this machine is described. Furthermore, loss analysis of the machine in various modes is presented and the torque-speed curves for asynchronous modes are obtained. A 2-D magnetodynamic finite element model based on the D-180 4/8 pole prototype machine is extracted and simulated to verify the results.展开更多
The brushless doubly-fed induction generator(BDFIG)presents significant potential for application in wind power systems,primarily due to the elimination of slip rings and brushes.The application of virtual synchronous...The brushless doubly-fed induction generator(BDFIG)presents significant potential for application in wind power systems,primarily due to the elimination of slip rings and brushes.The application of virtual synchronous control(VSynC)has been demonstrated to effectively augment the inertia of BDFIG systems.However,the dynamic characteristics and stability of BDFIG under weak grid conditions remain largely unexplored.The critical stabilizing factors for BDFIG-based wind turbines(WTs)are methodically investigated,and an enhanced VSynC method based on linear active disturbance rejection control(LADRC)is proposed.The stability analysis reveals that the proposed method can virtually enhance the stability of the grid-connected system under weak grid conditions.The accuracy of the theoretical analysis and the effectiveness of the proposed method are affirmed through extensive simulations and detailed experiments.展开更多
As the core component of energy conversion for large wind turbines,the output performance of doubly-fed induction generators (DFIGs) plays a decisive role in the power quality of wind turbines.To realize the fast and ...As the core component of energy conversion for large wind turbines,the output performance of doubly-fed induction generators (DFIGs) plays a decisive role in the power quality of wind turbines.To realize the fast and accurate design optimization of DFIGs,this paper proposes a novel hybriddriven surrogate-assisted optimization method.It firstly establishes an accurate subdomain model of DFIGs to analytically predict performance indexes.Furthermore,taking the inexpensive analytical dataset produced by the subdomain model as the source domain and the expensive finite element analysis dataset as the target domain,a high-precision surrogate model is trained in a transfer learning way and used for the subsequent multi-objective optimization process.Based on this model,taking the total harmonic distortion of electromotive force,cogging torque,and iron loss as objectives,and the slot and inner/outer diameters as parameters for optimizing the topology,achieve a rapid and accurate electromagnetic design for DFIGs.Finally,experiments are carried out on a 3MW DFIG to validate the effectiveness of the proposed method.展开更多
The brushless doubly-fed machine(BDFM)is a family of multiport electric machines with two ac electrical ports and a common mechanical port.Different from the conventional singly-fed machines whose synchronous speed is...The brushless doubly-fed machine(BDFM)is a family of multiport electric machines with two ac electrical ports and a common mechanical port.Different from the conventional singly-fed machines whose synchronous speed is solely determined by a single supply frequency and the actual pole pair number,the BDFM has two supply frequencies and two different pole pair numbers to control the rotor speed.By the two accessible electrical ports,all BDFMs are endowed with more degrees of freedom for speed and power control,inherent fault-tolerant capability and high reliability.The BDFM in its broad sense has been extensively investigated as a promising alternative to the conventional slip-ring doubly-fed induction machine(DFIM)during the past decades,for both limited and wide speed range applications.This paper presents a new theoretical framework of the BDFM within which all topological variants can be closely linked by the similarities in working principle.The individualities of each machine topology are presented first,followed by the commonalities such as the modeling techniques,modes of operation,design considerations and control strategies.The challenges are identified and highlighted based on recent developments and possible opportunities are predicted considering the unique nature of this special AC machine type.展开更多
In this paper,a new dual-stator brushless doubly-fed induction machine with a staggered dual cage rotor is proposed,with emphasis on the general interconnection rule of the conductor bars for the staggered dual cage r...In this paper,a new dual-stator brushless doubly-fed induction machine with a staggered dual cage rotor is proposed,with emphasis on the general interconnection rule of the conductor bars for the staggered dual cage rotor.Since the squirrel cage rotor offers the merits of robustness,reliable structure,high slot filling factor,and low rotor resistance comparing to the wound rotor,it is introduced to the dual-stator brushless doubly-fed induction machine to solve the problems of high copper loss and unreliable rotor structure for the dual-stator brushless doubly-fed induction machine with a wound rotor.The originality of this article is to investigate the interconnection rule of conductor bars between the inner and outer cages.The constraint condition that is supposed to be satisfied is deduced by using the rotating magneto-motive force theory,based on which diverse slot/pole combinations are investigated.The performance comparison between the existing and proposed machines is conducted.Finally,a prototype is designed and fabricated.The experimental results verify the effectiveness of the proposed topology.展开更多
The brushless doubly-fed machine(BDFM)has been widely used due to its advantages of robustness,reliable operation,ease of maintenance,adjustable power factor,small converter capacity and low cost.BDFM is attractive fo...The brushless doubly-fed machine(BDFM)has been widely used due to its advantages of robustness,reliable operation,ease of maintenance,adjustable power factor,small converter capacity and low cost.BDFM is attractive for use in many applications such as variable frequency speed regulation systems and variable speed constant frequency generation systems.Hence,there is a rapidly growing interest in design and control of BDFM.In this paper,the origin and development of BDFM are reviewed,the structural characteristics of BDFM are discussed at length,the principles of operation and design are analyzed,and the different control methods used for BDFM are overviewed and compared in detail.Finally,challenges and opportunities of BDFM are concluded.展开更多
In this paper, based on the analysis of the mathematical model in a common synchronous reference frame of the brushless doubly-fed generator (BDFG), the grid connection strategy and maximum energy extraction control...In this paper, based on the analysis of the mathematical model in a common synchronous reference frame of the brushless doubly-fed generator (BDFG), the grid connection strategy and maximum energy extraction control were both analyzed. Besides, the transient simula- tion of no-load model and generation model of the BDFG have been developed on the MATLAB/Simulink platform. The test results during cutting-in grid confirmed the good dynamic performance of grid synchronization and effective power control approach for the BDFG-based variable speed wind turbines.展开更多
Owing to their stability,doubly-fed induction generator(DFIG)integrated systems have gained considerable interest and are the most widely implemented type of wind turbines and due to the increasing escalation of the w...Owing to their stability,doubly-fed induction generator(DFIG)integrated systems have gained considerable interest and are the most widely implemented type of wind turbines and due to the increasing escalation of the wind generation penetration rate in power systems.In this study,we investigate a DFIG integrated system comprising four modules:(1)a wind turbine that considers the maximum power point tracking and pitch-angle control,(2)induction generator,(3)rotor/grid-side converter with the corresponding control strategy,and(4)AC power grid.The detailed small-signal modeling of the entire system is performed by linearizing the dynamic characteristic equation at the steady-state value.Furthermore,a dichotomy method is proposed based on the maximum eigenvalue real part function to obtain the critical value of the parameters.Root-locus analysis is employed to analyze the impact of changes in the phase-locked loop,short-circuit ratio,and blade inertia on the system stability.Lastly,the accuracy of the small-signal model and the real and imaginary parts of the calculated dominant poles in the theoretical analysis are verified using PSCAD/EMTDC.展开更多
In order to solve the problems of rotor overvoltage,overcurrent and DC side voltage rise caused by grid voltage drops,a coordinated control strategy based on symmetrical and asymmetrical low voltage ride through of ro...In order to solve the problems of rotor overvoltage,overcurrent and DC side voltage rise caused by grid voltage drops,a coordinated control strategy based on symmetrical and asymmetrical low voltage ride through of rotor side converter of the doubly-fed generator is proposed.When the power grid voltage drops symmetrically,the generator approximate equation under steady-state conditions is no longer applicable.Considering the dynamic process of stator current excitation,according to the change of stator flux and the depth of voltage drop,the system can dynamically provide reactive power support for parallel nodes and suppress the rise of DC side voltage and rotor over-current.When the grid voltage drops asymmetrically,the positive and negative sequence components are separated in the rotating coordinate system.The doubly fed generator model is established to suppress the rotor positive sequence current and negative sequence current respectively.At the same time,the output voltage limit of the converter is discussed,and the reference value is adjusted within the allowable output voltage range.In order to adapt to the occurrence of different types of power grid faults and complex operating conditions,a fast switching module of fault type detection and rotor control mode is designed to detect the type of power grid faults and voltage drop depth in real time and switch the rotor side control mode dynamically.Finally,the simulation model of the doubly fed wind turbine is constructed in Matlab/Simulink.The simulation results verify that the proposed control strategy can improve the low-voltage ride through performance of the system when dealing with the symmetrical and asymmetric voltage drop of the power grid and identify the power grid fault type and provide the correct control strategy.展开更多
This article proposes a dual-negative-objective coordinated control strategy for brushless doubly fed induction generator(BDFIG)based wind power generation system under unbalanced grid voltage.To alleviate the mechani...This article proposes a dual-negative-objective coordinated control strategy for brushless doubly fed induction generator(BDFIG)based wind power generation system under unbalanced grid voltage.To alleviate the mechanical stress and impaction on rotating shaft,the negative control objective(NCO)of machine side converter(MSC)is set to suppress the ripple of electromagnetic torque.While the NCO of grid side converter(GSC)is selected to suppress the oscillation of total output active power or the unbalanced degree of total output current for BDFIG generation system.In comparison with traditional single converter control scheme of the MSC or GSC,dual NCOs can be satisfied at the same time due to the enlarged freedom degree in the proposed improved coordinated control system for back-toback converters.The effectiveness of proposed control strategy is validated by simulation and experimental results on a dual-cagerotor BDFIG(DCR-BDFIG)prototype.展开更多
A unified spiral vector model is presented that can be used to assist the finite element method-based performance analysis of brushless doubly-fed induction machines with various short-circuited rotor windings.Specifi...A unified spiral vector model is presented that can be used to assist the finite element method-based performance analysis of brushless doubly-fed induction machines with various short-circuited rotor windings.Specifically,magnet-free brushless doubly-fed induction machines working in doubly-fed or singly-fed synchronous mode are investigated.A dynamic model in spiral vector notation is developed,based on which the torque-angle and power-angle characteristics are derived.It is shown that the investigated brushless machines are equivalent to a traditional non-salient-pole synchronous machine with brushes.By introducing a conversion factor,they can also be analyzed with methods similar to the conventional phasor theory.A comparison is made between the brushless doubly-fed induction machine and non-salient-pole wound-field synchronous machine with brushes,revealing that the performance of the brushless machine degrades faster when the laminated core is saturated.A scaled-down prototype is tested to validate the effectiveness of the theoretical analysis.展开更多
To lower the difficulty of fault protection,a doubly-fed induction machine based shipboard propulsion system(DFIM-SPS)that is partially power decoupled is presented.In such an intrinsically safe SPS architecture,a syn...To lower the difficulty of fault protection,a doubly-fed induction machine based shipboard propulsion system(DFIM-SPS)that is partially power decoupled is presented.In such an intrinsically safe SPS architecture,a synchronous generator(SG)is employed for power generation,and the accuracy of the parameters of power generation unit(PGU)plays an important role in SPS stable operation.In this paper,the PGU parameter deviations are studied to evaluate the effects on system performance.The models of salient-pole SG,type DC1A excitation system(EXS)and DFIM are illustrated first.Besides,the corresponding control scheme is explained.For the 16 important parameters of PGU,up to 40%of parameter deviations are applied to implement parameter sensitivity analysis.Then,simulation studies are carried out to evaluate the parameter deviation effects on system performance in detail.By defining three parameter deviation effect indicators(PDEIs),the effects on the PGU output variables,which are the terminal voltage and output active power,are studied.Moreover,the increasing rates of PDEIs with different degrees of parameter deviations for the key parameters are analyzed.Furthermore,the overall system performance is investigated for the two most influential PGU parameters.This paper provides some vital clues on SG and EXS parameter identification for DFIM-SPS.展开更多
A novel transient rotor current control scheme is proposed in this paper for a doubly-fed induction generator(DFIG)equipped with a superconducting magnetic energy storage(SMES) device to enhance its transient volt...A novel transient rotor current control scheme is proposed in this paper for a doubly-fed induction generator(DFIG)equipped with a superconducting magnetic energy storage(SMES) device to enhance its transient voltage and frequency support capacity during grid faults. The SMES connected to the DC-link capacitor of the DFIG is controlled to regulate the transient dc-link voltage so that the whole capacity of the grid side converter(GSC) is dedicated to injecting reactive power to the grid for the transient voltage support. However, the rotor-side converter(RSC) has different control tasks for different periods of the grid fault. Firstly, for Period I, the RSC injects the demagnetizing current to ensure the controllability of the rotor voltage. Then, since the dc stator flux degenerates rapidly in Period II, the required demagnetizing current is low in Period II and the RSC uses the spare capacity to additionally generate the reactive(priority) and active current so that the transient voltage capability is corroborated and the DFIG also positively responds to the system frequency dynamic at the earliest time. Finally, a small amount of demagnetizing current is provided after the fault clearance. Most of the RSC capacity is used to inject the active current to further support the frequency recovery of the system. Simulations are carried out on a simple power system with a wind farm. Comparisons with other commonly used control methods are performed to validate the proposed control method.展开更多
Because the mover and stator of a doubly-fed linear motor are both equipped with three-phase windings, the motor enables contactless energy to be transferred from the stator to the mover. Thus, when a doubly-fed linea...Because the mover and stator of a doubly-fed linear motor are both equipped with three-phase windings, the motor enables contactless energy to be transferred from the stator to the mover. Thus, when a doubly-fed linear motor is used in the linear driving system of trains, neither an overhead line nor a third rail is needed. However, the doubly- fed motor will lead to more severe thrust fluctuation than the unilateral motors. In order to overcome this shortcoming, the thrust fluctuation of the doubly-fed motor should be analyzed. In this paper, an expression for motor thrust is derived. It points out that the slot effect caused by the slotted structure is the main reason for the increase of thrust fluctuation. The method of adopting unequal pole pitch and unequal slot numbers per pole per phase of stator and mover, is proposed to weaken the slot effect when designing the motor slot parameters. Three different motor models are simulated by ANSOFT. The proposed method results in a motor thrust fluctuation coefficient of 8.4%, compared to 49.4% for the conventional method. Therefore, the motor's thrust fluctuation is effectively suppressed by the proposed method.展开更多
Nested-loop secondary linear doubly-fed machine(NLS-LDFM) is a novel linear machine evolved from rotary brushless doubly-fed induction machine, which has a good application prospect in linear metro. In order to analyz...Nested-loop secondary linear doubly-fed machine(NLS-LDFM) is a novel linear machine evolved from rotary brushless doubly-fed induction machine, which has a good application prospect in linear metro. In order to analyze the performance of NLS-LDFM, the mechanism and action rules of end effects are investigated in this paper. Firstly, the mechanism of static and dynamic end effects is analyzed in aspect of direct coupling, winding asymmetry and transient secondary current. Furthermore, based on the winding theory for short primary linear machines, the machine parameters are established qualitatively considering pulsating magnetic field of NLS-LDFM. Finally, the NLS-LDFM performance analysis is supplemented by the finite element algorithm(FEA) simulation and experiments under different operating conditions.展开更多
Application of a DFIG (doubly-fed induction generator), which is one of adjustable speed generators, to a gas engine cogeneration system has been investigated. To operate during a blackout as an emergency power supp...Application of a DFIG (doubly-fed induction generator), which is one of adjustable speed generators, to a gas engine cogeneration system has been investigated. To operate during a blackout as an emergency power supply is one of important roles for the gas engine eogeneration system. In the case of conventional constant speed of synchronous generator, the amount of the allowed step load is limited to around 30% of the rated power. On the other hand, DFIG is expected to increase the amount of step load during the stand-alone operation. In this paper, it has been demonstrated that an increase in the gas engine speed resulted in an increase in the maximum amount of step load using experimental equipment with a real gas engine. It has been concluded that the proposed system can improve the performance of an emergency power supply at step-loading.展开更多
基金supported in part by the National Natural Science Foundation of China under Grant 51537007。
文摘The brushless doubly-fed wind power system based on conventional power control strategies lacks ‘inertia’ and the ability to support grid,which leads to the decline of grid stability.Therefore,a control strategy of brushless doubly-fed reluctance generator(BDFRG) based on virtual synchronous generator(VSG) control is proposed to solve the problem in this paper.The output characteristics of BDFRG based on VSG are similar to a synchronous generator(SG),which can support the grid frequency and increase the system ‘inertia’.According to the mathematical model of BDFRG,the inner loop voltage source control of BDFRG is derived.In addition,the specific structure and parameter selection principle of outer loop VSG control are expounded.The voltage source control inner loop of BDFRG is combined with the VSG control outer loop to establish the overall architecture of BDFRG-VSG control strategy.Finally,the effectiveness and feasibility of the proposed strategy are verified in the simulation.
基金This work was supported in part by the National Natural Science Foundation of China(NSFC)under Grants 51707079 and 51877093in part by the National Key Research and Development Program of China(Project ID:YS2018YFGH000200)in part by the Fundamental Research Funds for the Central Universities(Project ID:2019kfyXMBZ031).
文摘The aim of this paper is to investigate an adaptive sensorless direct voltage control(DVC)strategy for the stand-alone ship shaft brushless doubly-fed induction generators(BDFIGs).The proposed new rotor position observer using the space vector flux relations of BDFIG may achieve the desired voltage control of the power winding(PW)in terms of magnitude and frequency,without any speed/position sensors.The proposed algorithm does not require any additional observers for obtaining the generator speed.The proposed technique can directly achieve the desired DVC based on the estimated rotor position,which may reduce the overall system cost.The stability analysis of the proposed observer is investigated and confirmed with the concept of quadratic Lyapunov function and using the multi-model representation.In addition,the sensitivity analysis of the presented method is confirmed under different issues of parameter uncertainties.Comprehensive results from both simulation and experiments are realized with a prototype wound-rotor BDFIG,which demonstrate the capability and efficacy of the proposed sensorless DVC strategy with good transient behavior under different operating conditions.Furthermore,the analysis confirms the robustness of the proposed observer via the machine parameter changes.
文摘VFT (variable frequency transformer) has been recently used as art alternative to HVDC (high voltage direct current) to control power flow between asynchronous networks. VFT consumes less reactive power than a back-to-back HVDC system, provides faster initial transient recovery, and has better natural damping capability. VFT is simply a DFIM (doubly-fed induction machine) where the machine torque controls the power flow from stator to rotor and vice versa. The main disadvantage of this VFT is the slip rings and brushes required for the rotor circuit, especially in bulk power transmission. The BDFM (brushless doubly-fed machine) with nested cage rotor machine is proved to be a comparable alternative to conventional DFIM in many applications with the advantage that all windings being in the stator frame with fixed output terminals. In this paper, the BDFM is used as a BVFT (brushless variable frequency transformer). A prototype machine is designed and simulated to verify the system validity.
文摘Brushless Doubly-Fed Machine has attracted considerable attention in recent years due to its advantages. It has the robustness of the squirrel cage induction machine, and the speed and power factor controllability of the synchronous machine as well as the absence of brushes and slip rings, and using a fractionally rated frequency converter. Hence, there are considerable benefits over the conventional machines, when the machine is applied to applications such as a wind turbine generator or high power adjustable speed drive. However, these benefits are obtained in slightly more complex structure, higher cost and larger dimensions in comparison to the conventional induction machine. This paper presents fundamental aspects of the three modes of operation of brushless doubly fed machine, i.e. simple induction mode, cascade induction mode, and synchronous mode. The investigation is performed by analyzing the spatial harmonic contents of the rotor magnetic flux density. The direct cross couplings between stator and rotor fields as well as, indirect cross coupling between stator fields by the special rotor of this machine is described. Furthermore, loss analysis of the machine in various modes is presented and the torque-speed curves for asynchronous modes are obtained. A 2-D magnetodynamic finite element model based on the D-180 4/8 pole prototype machine is extracted and simulated to verify the results.
基金supported by the National Natural Science Foundation of China(No.52077222)the Shandong Provincial Natural Science Foundation(No.ZR2023QE156)。
文摘The brushless doubly-fed induction generator(BDFIG)presents significant potential for application in wind power systems,primarily due to the elimination of slip rings and brushes.The application of virtual synchronous control(VSynC)has been demonstrated to effectively augment the inertia of BDFIG systems.However,the dynamic characteristics and stability of BDFIG under weak grid conditions remain largely unexplored.The critical stabilizing factors for BDFIG-based wind turbines(WTs)are methodically investigated,and an enhanced VSynC method based on linear active disturbance rejection control(LADRC)is proposed.The stability analysis reveals that the proposed method can virtually enhance the stability of the grid-connected system under weak grid conditions.The accuracy of the theoretical analysis and the effectiveness of the proposed method are affirmed through extensive simulations and detailed experiments.
文摘As the core component of energy conversion for large wind turbines,the output performance of doubly-fed induction generators (DFIGs) plays a decisive role in the power quality of wind turbines.To realize the fast and accurate design optimization of DFIGs,this paper proposes a novel hybriddriven surrogate-assisted optimization method.It firstly establishes an accurate subdomain model of DFIGs to analytically predict performance indexes.Furthermore,taking the inexpensive analytical dataset produced by the subdomain model as the source domain and the expensive finite element analysis dataset as the target domain,a high-precision surrogate model is trained in a transfer learning way and used for the subsequent multi-objective optimization process.Based on this model,taking the total harmonic distortion of electromotive force,cogging torque,and iron loss as objectives,and the slot and inner/outer diameters as parameters for optimizing the topology,achieve a rapid and accurate electromagnetic design for DFIGs.Finally,experiments are carried out on a 3MW DFIG to validate the effectiveness of the proposed method.
文摘The brushless doubly-fed machine(BDFM)is a family of multiport electric machines with two ac electrical ports and a common mechanical port.Different from the conventional singly-fed machines whose synchronous speed is solely determined by a single supply frequency and the actual pole pair number,the BDFM has two supply frequencies and two different pole pair numbers to control the rotor speed.By the two accessible electrical ports,all BDFMs are endowed with more degrees of freedom for speed and power control,inherent fault-tolerant capability and high reliability.The BDFM in its broad sense has been extensively investigated as a promising alternative to the conventional slip-ring doubly-fed induction machine(DFIM)during the past decades,for both limited and wide speed range applications.This paper presents a new theoretical framework of the BDFM within which all topological variants can be closely linked by the similarities in working principle.The individualities of each machine topology are presented first,followed by the commonalities such as the modeling techniques,modes of operation,design considerations and control strategies.The challenges are identified and highlighted based on recent developments and possible opportunities are predicted considering the unique nature of this special AC machine type.
基金supported by the National Natural Science Foundation of China (Grant No.61973073)。
文摘In this paper,a new dual-stator brushless doubly-fed induction machine with a staggered dual cage rotor is proposed,with emphasis on the general interconnection rule of the conductor bars for the staggered dual cage rotor.Since the squirrel cage rotor offers the merits of robustness,reliable structure,high slot filling factor,and low rotor resistance comparing to the wound rotor,it is introduced to the dual-stator brushless doubly-fed induction machine to solve the problems of high copper loss and unreliable rotor structure for the dual-stator brushless doubly-fed induction machine with a wound rotor.The originality of this article is to investigate the interconnection rule of conductor bars between the inner and outer cages.The constraint condition that is supposed to be satisfied is deduced by using the rotating magneto-motive force theory,based on which diverse slot/pole combinations are investigated.The performance comparison between the existing and proposed machines is conducted.Finally,a prototype is designed and fabricated.The experimental results verify the effectiveness of the proposed topology.
基金National Natural Science Foundation of China(51537007)PhD Start-up Fund of Natural Science Foundation of Liaoning Province,China(20141072).
文摘The brushless doubly-fed machine(BDFM)has been widely used due to its advantages of robustness,reliable operation,ease of maintenance,adjustable power factor,small converter capacity and low cost.BDFM is attractive for use in many applications such as variable frequency speed regulation systems and variable speed constant frequency generation systems.Hence,there is a rapidly growing interest in design and control of BDFM.In this paper,the origin and development of BDFM are reviewed,the structural characteristics of BDFM are discussed at length,the principles of operation and design are analyzed,and the different control methods used for BDFM are overviewed and compared in detail.Finally,challenges and opportunities of BDFM are concluded.
文摘In this paper, based on the analysis of the mathematical model in a common synchronous reference frame of the brushless doubly-fed generator (BDFG), the grid connection strategy and maximum energy extraction control were both analyzed. Besides, the transient simula- tion of no-load model and generation model of the BDFG have been developed on the MATLAB/Simulink platform. The test results during cutting-in grid confirmed the good dynamic performance of grid synchronization and effective power control approach for the BDFG-based variable speed wind turbines.
基金supported by the Key Laboratory of Modern Power System Simulation and Control&Renewable Energy Technology,Ministry of Education(Northeast Electric Power University),Jilin 132012,China(MPSS2023-06).
文摘Owing to their stability,doubly-fed induction generator(DFIG)integrated systems have gained considerable interest and are the most widely implemented type of wind turbines and due to the increasing escalation of the wind generation penetration rate in power systems.In this study,we investigate a DFIG integrated system comprising four modules:(1)a wind turbine that considers the maximum power point tracking and pitch-angle control,(2)induction generator,(3)rotor/grid-side converter with the corresponding control strategy,and(4)AC power grid.The detailed small-signal modeling of the entire system is performed by linearizing the dynamic characteristic equation at the steady-state value.Furthermore,a dichotomy method is proposed based on the maximum eigenvalue real part function to obtain the critical value of the parameters.Root-locus analysis is employed to analyze the impact of changes in the phase-locked loop,short-circuit ratio,and blade inertia on the system stability.Lastly,the accuracy of the small-signal model and the real and imaginary parts of the calculated dominant poles in the theoretical analysis are verified using PSCAD/EMTDC.
基金The authors highly acknowledge the technology financial assistance provided by Jiangsu Frontier Electric Technology Co.,Ltd.(KJ202003).
文摘In order to solve the problems of rotor overvoltage,overcurrent and DC side voltage rise caused by grid voltage drops,a coordinated control strategy based on symmetrical and asymmetrical low voltage ride through of rotor side converter of the doubly-fed generator is proposed.When the power grid voltage drops symmetrically,the generator approximate equation under steady-state conditions is no longer applicable.Considering the dynamic process of stator current excitation,according to the change of stator flux and the depth of voltage drop,the system can dynamically provide reactive power support for parallel nodes and suppress the rise of DC side voltage and rotor over-current.When the grid voltage drops asymmetrically,the positive and negative sequence components are separated in the rotating coordinate system.The doubly fed generator model is established to suppress the rotor positive sequence current and negative sequence current respectively.At the same time,the output voltage limit of the converter is discussed,and the reference value is adjusted within the allowable output voltage range.In order to adapt to the occurrence of different types of power grid faults and complex operating conditions,a fast switching module of fault type detection and rotor control mode is designed to detect the type of power grid faults and voltage drop depth in real time and switch the rotor side control mode dynamically.Finally,the simulation model of the doubly fed wind turbine is constructed in Matlab/Simulink.The simulation results verify that the proposed control strategy can improve the low-voltage ride through performance of the system when dealing with the symmetrical and asymmetric voltage drop of the power grid and identify the power grid fault type and provide the correct control strategy.
基金supported in part by National Natural Science Foundation of China under Grant 61973073supported by Jiangsu Province Higher Education Basic Science (Natural Science) Research Project under Grant 23KJB470022
文摘This article proposes a dual-negative-objective coordinated control strategy for brushless doubly fed induction generator(BDFIG)based wind power generation system under unbalanced grid voltage.To alleviate the mechanical stress and impaction on rotating shaft,the negative control objective(NCO)of machine side converter(MSC)is set to suppress the ripple of electromagnetic torque.While the NCO of grid side converter(GSC)is selected to suppress the oscillation of total output active power or the unbalanced degree of total output current for BDFIG generation system.In comparison with traditional single converter control scheme of the MSC or GSC,dual NCOs can be satisfied at the same time due to the enlarged freedom degree in the proposed improved coordinated control system for back-toback converters.The effectiveness of proposed control strategy is validated by simulation and experimental results on a dual-cagerotor BDFIG(DCR-BDFIG)prototype.
文摘A unified spiral vector model is presented that can be used to assist the finite element method-based performance analysis of brushless doubly-fed induction machines with various short-circuited rotor windings.Specifically,magnet-free brushless doubly-fed induction machines working in doubly-fed or singly-fed synchronous mode are investigated.A dynamic model in spiral vector notation is developed,based on which the torque-angle and power-angle characteristics are derived.It is shown that the investigated brushless machines are equivalent to a traditional non-salient-pole synchronous machine with brushes.By introducing a conversion factor,they can also be analyzed with methods similar to the conventional phasor theory.A comparison is made between the brushless doubly-fed induction machine and non-salient-pole wound-field synchronous machine with brushes,revealing that the performance of the brushless machine degrades faster when the laminated core is saturated.A scaled-down prototype is tested to validate the effectiveness of the theoretical analysis.
基金the National Natural Science Foundation of China under Grant 52007071 and 51907073the China Postdoctoral Science Foundation under Grant 3004131154 and 2020M672355the Applied Basic Frontier Program of Wuhan under Grant 2020010601012207。
文摘To lower the difficulty of fault protection,a doubly-fed induction machine based shipboard propulsion system(DFIM-SPS)that is partially power decoupled is presented.In such an intrinsically safe SPS architecture,a synchronous generator(SG)is employed for power generation,and the accuracy of the parameters of power generation unit(PGU)plays an important role in SPS stable operation.In this paper,the PGU parameter deviations are studied to evaluate the effects on system performance.The models of salient-pole SG,type DC1A excitation system(EXS)and DFIM are illustrated first.Besides,the corresponding control scheme is explained.For the 16 important parameters of PGU,up to 40%of parameter deviations are applied to implement parameter sensitivity analysis.Then,simulation studies are carried out to evaluate the parameter deviation effects on system performance in detail.By defining three parameter deviation effect indicators(PDEIs),the effects on the PGU output variables,which are the terminal voltage and output active power,are studied.Moreover,the increasing rates of PDEIs with different degrees of parameter deviations for the key parameters are analyzed.Furthermore,the overall system performance is investigated for the two most influential PGU parameters.This paper provides some vital clues on SG and EXS parameter identification for DFIM-SPS.
基金supported by the National Natural Science Foundation of China(Grant No.51307124)the Major Program of the National Natural Science Foundation of China(Grant No.51190105)
文摘A novel transient rotor current control scheme is proposed in this paper for a doubly-fed induction generator(DFIG)equipped with a superconducting magnetic energy storage(SMES) device to enhance its transient voltage and frequency support capacity during grid faults. The SMES connected to the DC-link capacitor of the DFIG is controlled to regulate the transient dc-link voltage so that the whole capacity of the grid side converter(GSC) is dedicated to injecting reactive power to the grid for the transient voltage support. However, the rotor-side converter(RSC) has different control tasks for different periods of the grid fault. Firstly, for Period I, the RSC injects the demagnetizing current to ensure the controllability of the rotor voltage. Then, since the dc stator flux degenerates rapidly in Period II, the required demagnetizing current is low in Period II and the RSC uses the spare capacity to additionally generate the reactive(priority) and active current so that the transient voltage capability is corroborated and the DFIG also positively responds to the system frequency dynamic at the earliest time. Finally, a small amount of demagnetizing current is provided after the fault clearance. Most of the RSC capacity is used to inject the active current to further support the frequency recovery of the system. Simulations are carried out on a simple power system with a wind farm. Comparisons with other commonly used control methods are performed to validate the proposed control method.
文摘Because the mover and stator of a doubly-fed linear motor are both equipped with three-phase windings, the motor enables contactless energy to be transferred from the stator to the mover. Thus, when a doubly-fed linear motor is used in the linear driving system of trains, neither an overhead line nor a third rail is needed. However, the doubly- fed motor will lead to more severe thrust fluctuation than the unilateral motors. In order to overcome this shortcoming, the thrust fluctuation of the doubly-fed motor should be analyzed. In this paper, an expression for motor thrust is derived. It points out that the slot effect caused by the slotted structure is the main reason for the increase of thrust fluctuation. The method of adopting unequal pole pitch and unequal slot numbers per pole per phase of stator and mover, is proposed to weaken the slot effect when designing the motor slot parameters. Three different motor models are simulated by ANSOFT. The proposed method results in a motor thrust fluctuation coefficient of 8.4%, compared to 49.4% for the conventional method. Therefore, the motor's thrust fluctuation is effectively suppressed by the proposed method.
基金supported in part by the National Natural Science Foundations of China under Grants 52277050 and 51877093the fund from Science,Technology,Shenzhen International Collaboration under Grant GJHZ20210705142539007+1 种基金the Key Research and Development Program of Sichuan Province under Grant 2021YFG0081the fund from Science,Technology and Innovation Commission of Shenzhen Municipality under Grant JCYJ20190809101205546。
文摘Nested-loop secondary linear doubly-fed machine(NLS-LDFM) is a novel linear machine evolved from rotary brushless doubly-fed induction machine, which has a good application prospect in linear metro. In order to analyze the performance of NLS-LDFM, the mechanism and action rules of end effects are investigated in this paper. Firstly, the mechanism of static and dynamic end effects is analyzed in aspect of direct coupling, winding asymmetry and transient secondary current. Furthermore, based on the winding theory for short primary linear machines, the machine parameters are established qualitatively considering pulsating magnetic field of NLS-LDFM. Finally, the NLS-LDFM performance analysis is supplemented by the finite element algorithm(FEA) simulation and experiments under different operating conditions.
文摘Application of a DFIG (doubly-fed induction generator), which is one of adjustable speed generators, to a gas engine cogeneration system has been investigated. To operate during a blackout as an emergency power supply is one of important roles for the gas engine eogeneration system. In the case of conventional constant speed of synchronous generator, the amount of the allowed step load is limited to around 30% of the rated power. On the other hand, DFIG is expected to increase the amount of step load during the stand-alone operation. In this paper, it has been demonstrated that an increase in the gas engine speed resulted in an increase in the maximum amount of step load using experimental equipment with a real gas engine. It has been concluded that the proposed system can improve the performance of an emergency power supply at step-loading.