The orthogonal experiments, which involves three factors: aeration intensity, suction time and suction suspended time, were designed to research membrane fouling of jet loop membrane bioreactor (JLMBR). Experimenta...The orthogonal experiments, which involves three factors: aeration intensity, suction time and suction suspended time, were designed to research membrane fouling of jet loop membrane bioreactor (JLMBR). Experimental results indicate that increasing aeration intensity, reducing suction time and increasing suction suspended time all could mitigate membrane fouling effectively. However excessive aeration intensity, too short suction time and excessive suction suspended time were bad for bioreactor running. The optimal aeration intensity, suction time and suction suspended time were 0.75 1.00 m3/(m2.h), 8 -10 min and 4 -5 min, respectively. The three factors all had effect on membrane pollution rate, while the suction time was the most important one and followed by aeration intensity and suction suspended time. It also indicates that, comparing with traditional submerged membrane bioreactors, JLMBR had lower membrane pollution rate.展开更多
In order to improve removal for nitrogen in a pilot-scale submerged membrane bioreactor(SMBR),intermittent aeration was conducted,and the effect on the treatment performance under four kinds of operation condition(...In order to improve removal for nitrogen in a pilot-scale submerged membrane bioreactor(SMBR),intermittent aeration was conducted,and the effect on the treatment performance under four kinds of operation condition(run 1,continuous aeration;run 2,60/60 min aeration on/off time;run 3,60/90 min aeration on/off time;run 4,60/75 min aeration on/off time) was evaluated.The results showed that depending on the specific on/off of the aeration time ratio,removal efficiency of nitrogen could be improved significantly,and the removal rates of total nitrogen(TN) under different operation conditions were 28.0%,59.5%,66.8% and 70.7%,respectively.There were no obvious differences for removal rates for CODCr and ammonia among different operation conditions.In general,intermittent aeration could be used as a feasible way to improve treatment performance for nitrogen in the SMBR.展开更多
The cross-flow shearing action produced from the inferior aeration in the Submerged Membrane Bio-reactor(SMBR) is an effective way to further improve anti-fouling effects of membrane modules.Based on the widely-applie...The cross-flow shearing action produced from the inferior aeration in the Submerged Membrane Bio-reactor(SMBR) is an effective way to further improve anti-fouling effects of membrane modules.Based on the widely-applied vertical structure of flat membrane modules,improvements are made that ladder-type flat membrane structure is designed with a certain inclined angle θ so that the cross-flow velocity of bubble near the membrane surface can be held,and the intensity and times of elastic colli-sion between bubbles and membrane surface can be increased.This can improve scouring action of membrane surface on aeration and reduce energy consumption of strong aeration in SMBR.By de-ducing and improving the mathematics model of collision between bubble and vertical flat put forward by Vries,the relatively suitable incline angle θ under certain aeration place and in certain size rang of bubble can be obtained with the computer iterative calculation technology.Finally,for many groups of ladder-type flat membrane in parallel placement in the practical application of SMBR,some sugges-tions are offered:the interval distance of membrane modules is 8―15 mm,and aeration should be op-erated at 5―7 mm among membrane modules,and the optimal design angle of trapeziform membrane is 1.7°―2.5°.展开更多
基金Project supported by the Cooperation Program of China and Singapore(Grant No.042307013)
文摘The orthogonal experiments, which involves three factors: aeration intensity, suction time and suction suspended time, were designed to research membrane fouling of jet loop membrane bioreactor (JLMBR). Experimental results indicate that increasing aeration intensity, reducing suction time and increasing suction suspended time all could mitigate membrane fouling effectively. However excessive aeration intensity, too short suction time and excessive suction suspended time were bad for bioreactor running. The optimal aeration intensity, suction time and suction suspended time were 0.75 1.00 m3/(m2.h), 8 -10 min and 4 -5 min, respectively. The three factors all had effect on membrane pollution rate, while the suction time was the most important one and followed by aeration intensity and suction suspended time. It also indicates that, comparing with traditional submerged membrane bioreactors, JLMBR had lower membrane pollution rate.
基金Supported by the Key Science Research Project of the Eleventh Five-Year Plan (2008ZX07106-003, 2008ZX07316-004)Tianjin Binhai New Area’s Construction Science and Technology Action Planning Project of Chinese Academy of Scienses (TJZX2-YW-07)
文摘In order to improve removal for nitrogen in a pilot-scale submerged membrane bioreactor(SMBR),intermittent aeration was conducted,and the effect on the treatment performance under four kinds of operation condition(run 1,continuous aeration;run 2,60/60 min aeration on/off time;run 3,60/90 min aeration on/off time;run 4,60/75 min aeration on/off time) was evaluated.The results showed that depending on the specific on/off of the aeration time ratio,removal efficiency of nitrogen could be improved significantly,and the removal rates of total nitrogen(TN) under different operation conditions were 28.0%,59.5%,66.8% and 70.7%,respectively.There were no obvious differences for removal rates for CODCr and ammonia among different operation conditions.In general,intermittent aeration could be used as a feasible way to improve treatment performance for nitrogen in the SMBR.
文摘The cross-flow shearing action produced from the inferior aeration in the Submerged Membrane Bio-reactor(SMBR) is an effective way to further improve anti-fouling effects of membrane modules.Based on the widely-applied vertical structure of flat membrane modules,improvements are made that ladder-type flat membrane structure is designed with a certain inclined angle θ so that the cross-flow velocity of bubble near the membrane surface can be held,and the intensity and times of elastic colli-sion between bubbles and membrane surface can be increased.This can improve scouring action of membrane surface on aeration and reduce energy consumption of strong aeration in SMBR.By de-ducing and improving the mathematics model of collision between bubble and vertical flat put forward by Vries,the relatively suitable incline angle θ under certain aeration place and in certain size rang of bubble can be obtained with the computer iterative calculation technology.Finally,for many groups of ladder-type flat membrane in parallel placement in the practical application of SMBR,some sugges-tions are offered:the interval distance of membrane modules is 8―15 mm,and aeration should be op-erated at 5―7 mm among membrane modules,and the optimal design angle of trapeziform membrane is 1.7°―2.5°.