期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
DC boost converter with buck buffer
1
作者 REN Xiang WANG Yaoqi WANG Xiaopeng 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2021年第3期340-346,共7页
For a conventional high-power active power factor correction(APFC)boost converter,its output capacitor needs to be precharged,which means that two power switches of the main circuit and the control circuit are needed ... For a conventional high-power active power factor correction(APFC)boost converter,its output capacitor needs to be precharged,which means that two power switches of the main circuit and the control circuit are needed to be respectively turned on and turned off in a fixed order.After the main circuit switch is turned on,it is necessary to wait for precharging before turning on the control circuit power switch.Once an inadvertent operation is performed,an overcurrent phenomenon from the output capacitor will occur.In this study,the buck circuit is used as the pre-stage snubber circuit,which can directly supply power to the circuit without precharging the output capacitor.As a result,potential safety hazard caused by the overcurrent due to the capacitor and the charging maloperation during the start-up stage can be avoided.Theoretical analysis and simulation experiment show that the DC boost converter with buck buffer can maintain the peak value of the main circuit within the safe range when the device boot does not precharge the output capacitor,and thus the safety and stable operation of the DC boost converter are ensured. 展开更多
关键词 active power factor correction(APFC) boost converter precharging power switch OVERCURRENT buck buffer
下载PDF
上一页 1 下一页 到第