This article presents a distributed periodic eventtriggered(PET)optimal control scheme to achieve generation cost minimization and average bus voltage regulation in DC microgrids.In order to accommodate the generation...This article presents a distributed periodic eventtriggered(PET)optimal control scheme to achieve generation cost minimization and average bus voltage regulation in DC microgrids.In order to accommodate the generation constraints of the distributed generators(DGs),a virtual incremental cost is firstly designed,based on which an optimality condition is derived to facilitate the control design.To meet the discrete-time(DT)nature of modern control systems,the optimal controller is directly developed in the DT domain.Afterward,to reduce the communication requirement among the controllers,a distributed event-triggered mechanism is introduced for the DT optimal controller.The event-triggered condition is detected periodically and therefore naturally avoids the Zeno phenomenon.The closed-loop system stability is proved by the Lyapunov synthesis for switched systems.The generation cost minimization and average bus voltage regulation are obtained at the equilibrium point.Finally,switch-level microgrid simulations validate the performance of the proposed optimal controller.展开更多
According to the requirements of the bus terminal regulator,a linear regulator with 3-A source-sink current ability is presented.The use of the NMOS pass transistor and load current feedback technique enhances the sys...According to the requirements of the bus terminal regulator,a linear regulator with 3-A source-sink current ability is presented.The use of the NMOS pass transistor and load current feedback technique enhances the system current ability and response speed.The method of adaptive zero compensation realizes loop stability over the whole load range for either source or sink loop.Furthermore,the transconductance matching technique reduces the shoot-through current through the output stage to less than 3μA.The regulator has been fabricated with a 0.6-μm 30 V BCD process successfully,and the area size is about 1 mm;.With a 20μF output capacitor, the maximum transient output-voltage variation is within 3.5%of the output voltage with load step changes of±2 A/lμs.At the load range of±3 A,the variation of output voltage is less than±15 mV.展开更多
基金supported by the U.S.Office of Naval Research(N00014-21-1-2175)。
文摘This article presents a distributed periodic eventtriggered(PET)optimal control scheme to achieve generation cost minimization and average bus voltage regulation in DC microgrids.In order to accommodate the generation constraints of the distributed generators(DGs),a virtual incremental cost is firstly designed,based on which an optimality condition is derived to facilitate the control design.To meet the discrete-time(DT)nature of modern control systems,the optimal controller is directly developed in the DT domain.Afterward,to reduce the communication requirement among the controllers,a distributed event-triggered mechanism is introduced for the DT optimal controller.The event-triggered condition is detected periodically and therefore naturally avoids the Zeno phenomenon.The closed-loop system stability is proved by the Lyapunov synthesis for switched systems.The generation cost minimization and average bus voltage regulation are obtained at the equilibrium point.Finally,switch-level microgrid simulations validate the performance of the proposed optimal controller.
基金supported by the National Natural Science Foundation of China(Nos.60806043,60806009)the Special Fund for Basic Scientific Research of Central Colleges Chang'an University,China(No.CHD2010JC077)the Key Laboratory Foundation of Shaanxi Engineering and Technique Research Center for Road and Traffic Detection,China
文摘According to the requirements of the bus terminal regulator,a linear regulator with 3-A source-sink current ability is presented.The use of the NMOS pass transistor and load current feedback technique enhances the system current ability and response speed.The method of adaptive zero compensation realizes loop stability over the whole load range for either source or sink loop.Furthermore,the transconductance matching technique reduces the shoot-through current through the output stage to less than 3μA.The regulator has been fabricated with a 0.6-μm 30 V BCD process successfully,and the area size is about 1 mm;.With a 20μF output capacitor, the maximum transient output-voltage variation is within 3.5%of the output voltage with load step changes of±2 A/lμs.At the load range of±3 A,the variation of output voltage is less than±15 mV.