This study provides new insights into the comparison of cable-stayed and extradosed bridges based on the safety assessment of their stay cables.These bridges are often regarded as identical structures owing to the use...This study provides new insights into the comparison of cable-stayed and extradosed bridges based on the safety assessment of their stay cables.These bridges are often regarded as identical structures owing to the use of inclined cables;however,the international standards for bridge design stipulate different safety factors for stay cables of both types of bridges.To address this misconception,a comparative study was carried out on the safety factors of stay cables under fatigue and ultimate limit states by considering the effects of various untoward and damaging factors,such as overloading,cable loss,and corrosion.The primary goal of this study is to describe the structural disparities between both types of bridges and evaluate their structural redundancies by employing deterministic and nondeterministic methods.To achieve this goal,three-dimensional finite-element models of both bridges were developed based on the current design guidelines for stay cables in Japan.After the balanced states of the bridge models were achieved,static analyses were performed for different safety factors of stay cables in a parametric manner.Finally,the first-order reliability method and Monte Carlo method were applied to determine the reliability index of stay cables.The analysis results show that cable-stayed and extradosed bridges exhibit different structural redundancies for different safety factors under the same loading conditions.Moreover,a significant increase in structural redundancy occurs with an incremental increase in the safety factors of stay cables.展开更多
Optimum design of cable stayed bridges depends on number of parameters. Design of Cable stayed bridge satisfying all practical constraints is challenging to the designers. Considering the huge number of design variabl...Optimum design of cable stayed bridges depends on number of parameters. Design of Cable stayed bridge satisfying all practical constraints is challenging to the designers. Considering the huge number of design variables and practical constraints, Genetic Algorithms (GA) is most suitable for optimizing the cable stayed bridge. In the present work the optimum design is carried out by taking total material cost of bridge as objective function. During problem formulation most of the practical design variables and constraints are considered. Using genetic algorithms some parametric studies such as effect of geometric nonlinearity, effect of grouping of cables, effect of practical site constraints on tower height and side span, effect of bridge material, effect of cable layout, effect of extra-dosed bridges on optimum relative cost have been presented. Data base is prepared for new designers to estimate the relative cost of bridge.展开更多
Recently, research strives to apply Ultra High Performance Concrete (UHPC) to large-sized structures owing to its remarkable mechanical performance and durability compared to normal concrete. The Korea Institute of Co...Recently, research strives to apply Ultra High Performance Concrete (UHPC) to large-sized structures owing to its remarkable mechanical performance and durability compared to normal concrete. The Korea Institute of Construction Technology proposed SuperBridge800, an edge girder type UHPC cable stayed bridge with central span of 800 m, through its detailed design. The bridge is designed to be erected through the connection of precast UHPC segments. The precast UHPC segment is monolithically composed of one ribbed deck slab and edge girders at each side. The connection between the precast segments is achieved by steel bars at the edge girders and by UHPC cast-in-place wet joint at the slab. Despite of the outstanding mechanical performance of UHPC, the fabrication of large-sized members is a difficult task since UHPC hardens faster than normal concrete and requires a special curing process. Therefore, the constructability of large-sized UHPC segment should be secured to achieve SuperBridge800. Besides, the performance of the connection between segments should also be guaranteed, especially in terms of the fatigue performance of the UHPC cast-in-place joint, which constitutes a weak point. To that goal, two half-scaled UHPC segments are manufactured and the constructability is examined by fabricating a large-sized UHPC member connected with respect to the design conditions. This study conducts rolling fatigue test on the so-fabricated large-sized UHPC member. Rolling fatigue test is carried out up to 2 million cycles considering actual vehicle load at each center and quarter points of the member. The test results confirm that the service limit state is satisfied.展开更多
A full scale model test is done and a FEM model is established to investigate the fatigue behavior of the Nancha cable stayed bridge of the Nanjing Second Yangtz River Bridge, a long span steel bridge with a main sp...A full scale model test is done and a FEM model is established to investigate the fatigue behavior of the Nancha cable stayed bridge of the Nanjing Second Yangtz River Bridge, a long span steel bridge with a main span of 628 m. The results of test and FEM are analyzed and compared. It is shown that they are in good agreement. It is verified that the fatigue characteristic of the anchorage structure of cable and girder of the bridge satisfies the requirements specified by Chinese, British and American codes.展开更多
KICT (Korea Institute of Construction Technology) is conducting a project called “SUPER BRIDGE 200—Development of Low Cost and Long Life Hybrid Cable Stayed Bridge”. This project aims to reduce the construction and...KICT (Korea Institute of Construction Technology) is conducting a project called “SUPER BRIDGE 200—Development of Low Cost and Long Life Hybrid Cable Stayed Bridge”. This project aims to reduce the construction and main- tenance costs of long-span bridges by 20% and double their lifetime through the exploitation of ultra-high performance concrete (UHPC). This paper presents the design and construction of the first pedestrian cable stayed bridge using UHPC developed by KICT. UHPC, compared to conventional concrete, has not only high compressive and tensile strengths but also high ductility. The UHPC developed at KICT is a steel fiber-reinforced cement compound presenting design compressive strength larger than 180 MPa and design tensile strength exceeding 10 MPa with water-to-binder ratio below 0.24 and admixing of 2 volume percentage of steel fiber. To show the applicability of UHPC to structures, a pedestrian cable stayed bridge (Super Bridge I) exploiting the characteristics of the developed UHPC has been planned, designed and erected at KICT. The dimension of UHPC deck is 2.7 m × 7 m as a precast segment with a typical thickness of deck of only 7 cm. However, harmful crack was observed in the deck at the time of the fabrication of the deck segments. Accordingly, new fabrication method was conceived and applied to prevent cracking of the UHPC slender deck. Four UHPC deck segments were fabricated successfully without any crack. After construction, the dynamic characteristics (natural frequencies and mode shapes) were evaluated through vibration tests since several users felt excess vibration. A vertical tuned mass damper (TMD) was proposed and installed on the parapet of the bridge. The TMD reduces the acceleration by about 30% from 0.0316 g to 0.0244 g when two pedestrians are crossing the bridge.展开更多
A simplified fragility analysis of fan type cable stayed bridges usingProbabilistic Risk Analysis (PRA) procedure is presented for determining their failure probabilityunder random ground motion. Seismic input to the ...A simplified fragility analysis of fan type cable stayed bridges usingProbabilistic Risk Analysis (PRA) procedure is presented for determining their failure probabilityunder random ground motion. Seismic input to the bridge support is considered to be a riskconsistent response spectrum which is obtained from a separate analysis. For the response analysis,the bridge deck is modeled as a beam supported on springs at different points. The stiffnesses ofthe springs are determined by a separate 2D static analysis of cable-tower-deck system. The analysisprovides a coupled stiffness matrix for the spring system. A continuum method of analysis usingdynamic stiffness is Used to determine the dynamic properties of the bridges .The response of thebridge deck is obtained by the response spectrum method of analysis as applied to multi-degree offreedom system which duly takes into account the quasi - static component of bridge deck vibration.The fragility analysis includes uncertainties arising due to the variation in ground motion,material property, modeling, method of analysis, ductility factor and damage concentration effect.Probability of failure of the bridge deck is determined by the First Order Second Moment (FOSM)method of reliability. A three span double plane symmetrical fan type cable stayed bridge of totalspan 689 m, is used as an illustrative example. The fragility curves for the bridge deck failure areobtained under a number of parametric variations. Some of the important conclusions of the studyindicate that (ⅰ) not only vertical component but also the horizontal component of ground motionhas considerable effect on the probability of failure; (ⅱ) ground motion with no time lag betweensupport excitations provides a smaller probability of failure as compared to ground motion with verylarge time lag between support excitation; and (ⅲ) probability of failure may considerablyincrease for soft soil condition.展开更多
Changqing Yellow River Super-long Bridge of Zhengzhou-Ji'nan HSR is a partial cable-stayed bridge with concrete main girder and a unit length of 1,080 m.Studies are carried out on the key technologies of bridge de...Changqing Yellow River Super-long Bridge of Zhengzhou-Ji'nan HSR is a partial cable-stayed bridge with concrete main girder and a unit length of 1,080 m.Studies are carried out on the key technologies of bridge design,and the main conclusions are as follows:The whole unit adopts the supporting system of tower pier consolidation and tower-beam separation,and each pier is provided with seismic mitigation and isolation bearing;shaped-steel reinforced concrete bridge tower is adopted to bring into full play the tensile performance of steel and the compressive performance of concrete,and avoid the construction challenges of setting up multi-layer and multi-stirrup reinforcement while improving the bearing capacity of section;a new type of double-side and bi-directional anti-skid anchorage device is adopted for the cable saddle of wire divider pipe in order to withstand the unbalanced cable force,and verify the reliability of the anti-skid anchorage device by solid model test;and large-segment cantilever pouring design is adopted for the main girder with a maximum segment length of 8 m to effectively shorten the construction period of the bridge.展开更多
Numerical analyses of the coupled vibrations of vehicle-bridge system and the effects of different types of cable stayed bridges on the coupled vibration responses have been presented in this paper using ANSYS. The br...Numerical analyses of the coupled vibrations of vehicle-bridge system and the effects of different types of cable stayed bridges on the coupled vibration responses have been presented in this paper using ANSYS. The bridge model and vehicle model were independently built which have no internal relationship in the ANSYS. The vehicle-bridge coupled vibration relationship was obtained by using the APDL program which subsequently imposed on the vehicle and bridge models during the numerical analysis. The proposed model was validated through a field measurements and literature data. The judging method, possibility, and criterion of the vehicle-bridge resonance (coupled vibrations) of cable stayed bridges (both the floating system and half floating system) under traffic flows were presented. The results indicated that the interval time between vehicles is the main influence factor on the resonance excitation frequency under the condition of equally spaced traffic flows. Compared to other types of cable stayed bridges, the floating bridge system has relatively high possibility to cause vehicle-bridge resonance.展开更多
A stochastic optimal control strategy for a slightly sagged cable using support motion in the cable axial direction is proposed. The nonlinear equation of cable motion in plane is derived and reduced to the equations ...A stochastic optimal control strategy for a slightly sagged cable using support motion in the cable axial direction is proposed. The nonlinear equation of cable motion in plane is derived and reduced to the equations for the first two modes of cable vibration by using the Galerkin method. The partially averaged Ito equation for controlled system energy is further derived by applying the stochastic averaging method for quasi-non-integrable Hamiltonian systems. The dynamical programming equation for the controlled system energy with a performance index is established by applying the stochastic dynamical programming principle and a stochastic optimal control law is obtained through solving the dynamical programming equation. A bilinear controller by using the direct method of Lyapunov is introduced. The comparison between the two controllers shows that the proposed stochastic optimal control strategy is superior to the bilinear control strategy in terms of higher control effectiveness and efficiency.展开更多
The major reason of the failure of jointed rock-mass is the formation of the plastic zone near the crack tip ofⅠ-Ⅱmixed crack which leads to the growth,propagation of the branched crack under load condition.In the p...The major reason of the failure of jointed rock-mass is the formation of the plastic zone near the crack tip ofⅠ-Ⅱmixed crack which leads to the growth,propagation of the branched crack under load condition.In the paper,the failure judgment of mini-plastic zone's displacement is derived by the Mises yielding rule.The anchor cable is simulated by the different link elements and inflicting pre-strains according to the difference of mechanism of the consolidated segment and free segment.The stress and strain fields near crack tip of twain collinear cracks of different angles and consolidated conditions are simulated by iso-parametric element with eight nodes.The iso-parametric element with eight nodes is degenerated to singular element at crick tip to simulate crack.It is shown that the mini plastic zone's displacement near the crack tip begins to increase,then decreases with the increase of the angle of the crack.The better consolidated condition is,the smaller the angle of crack tip is when the mini plastic zone's displacement near the crack tip arrives at the biggest value.The mini plastic zone's displacement near the crack Tip 2 is bigger than that near the crack Tip 3.The crack is easier to failure with the increase of load.展开更多
The Millau viaduct over the Tam River is an exceptional bridge considering the height under the deck and the 2.5 km total length. Each of the seven high piers is founded on a thick raft setting on four large piles of ...The Millau viaduct over the Tam River is an exceptional bridge considering the height under the deck and the 2.5 km total length. Each of the seven high piers is founded on a thick raft setting on four large piles of 5 m in diameter and 10-15 m deep. The ground schematically consists of limestone in the north and of marls in the south. As the bridge is very sensitive to foundation settlements, the concessionary company decided to use the observational method for controlling the displacements and if necessary stabilize the foundations. The measurements show that the movements have remained small and admissible, particularly in terms of the rotations. The settlements have not occurred continuously under the load, but by steps.展开更多
文摘This study provides new insights into the comparison of cable-stayed and extradosed bridges based on the safety assessment of their stay cables.These bridges are often regarded as identical structures owing to the use of inclined cables;however,the international standards for bridge design stipulate different safety factors for stay cables of both types of bridges.To address this misconception,a comparative study was carried out on the safety factors of stay cables under fatigue and ultimate limit states by considering the effects of various untoward and damaging factors,such as overloading,cable loss,and corrosion.The primary goal of this study is to describe the structural disparities between both types of bridges and evaluate their structural redundancies by employing deterministic and nondeterministic methods.To achieve this goal,three-dimensional finite-element models of both bridges were developed based on the current design guidelines for stay cables in Japan.After the balanced states of the bridge models were achieved,static analyses were performed for different safety factors of stay cables in a parametric manner.Finally,the first-order reliability method and Monte Carlo method were applied to determine the reliability index of stay cables.The analysis results show that cable-stayed and extradosed bridges exhibit different structural redundancies for different safety factors under the same loading conditions.Moreover,a significant increase in structural redundancy occurs with an incremental increase in the safety factors of stay cables.
文摘Optimum design of cable stayed bridges depends on number of parameters. Design of Cable stayed bridge satisfying all practical constraints is challenging to the designers. Considering the huge number of design variables and practical constraints, Genetic Algorithms (GA) is most suitable for optimizing the cable stayed bridge. In the present work the optimum design is carried out by taking total material cost of bridge as objective function. During problem formulation most of the practical design variables and constraints are considered. Using genetic algorithms some parametric studies such as effect of geometric nonlinearity, effect of grouping of cables, effect of practical site constraints on tower height and side span, effect of bridge material, effect of cable layout, effect of extra-dosed bridges on optimum relative cost have been presented. Data base is prepared for new designers to estimate the relative cost of bridge.
文摘Recently, research strives to apply Ultra High Performance Concrete (UHPC) to large-sized structures owing to its remarkable mechanical performance and durability compared to normal concrete. The Korea Institute of Construction Technology proposed SuperBridge800, an edge girder type UHPC cable stayed bridge with central span of 800 m, through its detailed design. The bridge is designed to be erected through the connection of precast UHPC segments. The precast UHPC segment is monolithically composed of one ribbed deck slab and edge girders at each side. The connection between the precast segments is achieved by steel bars at the edge girders and by UHPC cast-in-place wet joint at the slab. Despite of the outstanding mechanical performance of UHPC, the fabrication of large-sized members is a difficult task since UHPC hardens faster than normal concrete and requires a special curing process. Therefore, the constructability of large-sized UHPC segment should be secured to achieve SuperBridge800. Besides, the performance of the connection between segments should also be guaranteed, especially in terms of the fatigue performance of the UHPC cast-in-place joint, which constitutes a weak point. To that goal, two half-scaled UHPC segments are manufactured and the constructability is examined by fabricating a large-sized UHPC member connected with respect to the design conditions. This study conducts rolling fatigue test on the so-fabricated large-sized UHPC member. Rolling fatigue test is carried out up to 2 million cycles considering actual vehicle load at each center and quarter points of the member. The test results confirm that the service limit state is satisfied.
文摘A full scale model test is done and a FEM model is established to investigate the fatigue behavior of the Nancha cable stayed bridge of the Nanjing Second Yangtz River Bridge, a long span steel bridge with a main span of 628 m. The results of test and FEM are analyzed and compared. It is shown that they are in good agreement. It is verified that the fatigue characteristic of the anchorage structure of cable and girder of the bridge satisfies the requirements specified by Chinese, British and American codes.
文摘KICT (Korea Institute of Construction Technology) is conducting a project called “SUPER BRIDGE 200—Development of Low Cost and Long Life Hybrid Cable Stayed Bridge”. This project aims to reduce the construction and main- tenance costs of long-span bridges by 20% and double their lifetime through the exploitation of ultra-high performance concrete (UHPC). This paper presents the design and construction of the first pedestrian cable stayed bridge using UHPC developed by KICT. UHPC, compared to conventional concrete, has not only high compressive and tensile strengths but also high ductility. The UHPC developed at KICT is a steel fiber-reinforced cement compound presenting design compressive strength larger than 180 MPa and design tensile strength exceeding 10 MPa with water-to-binder ratio below 0.24 and admixing of 2 volume percentage of steel fiber. To show the applicability of UHPC to structures, a pedestrian cable stayed bridge (Super Bridge I) exploiting the characteristics of the developed UHPC has been planned, designed and erected at KICT. The dimension of UHPC deck is 2.7 m × 7 m as a precast segment with a typical thickness of deck of only 7 cm. However, harmful crack was observed in the deck at the time of the fabrication of the deck segments. Accordingly, new fabrication method was conceived and applied to prevent cracking of the UHPC slender deck. Four UHPC deck segments were fabricated successfully without any crack. After construction, the dynamic characteristics (natural frequencies and mode shapes) were evaluated through vibration tests since several users felt excess vibration. A vertical tuned mass damper (TMD) was proposed and installed on the parapet of the bridge. The TMD reduces the acceleration by about 30% from 0.0316 g to 0.0244 g when two pedestrians are crossing the bridge.
文摘A simplified fragility analysis of fan type cable stayed bridges usingProbabilistic Risk Analysis (PRA) procedure is presented for determining their failure probabilityunder random ground motion. Seismic input to the bridge support is considered to be a riskconsistent response spectrum which is obtained from a separate analysis. For the response analysis,the bridge deck is modeled as a beam supported on springs at different points. The stiffnesses ofthe springs are determined by a separate 2D static analysis of cable-tower-deck system. The analysisprovides a coupled stiffness matrix for the spring system. A continuum method of analysis usingdynamic stiffness is Used to determine the dynamic properties of the bridges .The response of thebridge deck is obtained by the response spectrum method of analysis as applied to multi-degree offreedom system which duly takes into account the quasi - static component of bridge deck vibration.The fragility analysis includes uncertainties arising due to the variation in ground motion,material property, modeling, method of analysis, ductility factor and damage concentration effect.Probability of failure of the bridge deck is determined by the First Order Second Moment (FOSM)method of reliability. A three span double plane symmetrical fan type cable stayed bridge of totalspan 689 m, is used as an illustrative example. The fragility curves for the bridge deck failure areobtained under a number of parametric variations. Some of the important conclusions of the studyindicate that (ⅰ) not only vertical component but also the horizontal component of ground motionhas considerable effect on the probability of failure; (ⅱ) ground motion with no time lag betweensupport excitations provides a smaller probability of failure as compared to ground motion with verylarge time lag between support excitation; and (ⅲ) probability of failure may considerablyincrease for soft soil condition.
文摘Changqing Yellow River Super-long Bridge of Zhengzhou-Ji'nan HSR is a partial cable-stayed bridge with concrete main girder and a unit length of 1,080 m.Studies are carried out on the key technologies of bridge design,and the main conclusions are as follows:The whole unit adopts the supporting system of tower pier consolidation and tower-beam separation,and each pier is provided with seismic mitigation and isolation bearing;shaped-steel reinforced concrete bridge tower is adopted to bring into full play the tensile performance of steel and the compressive performance of concrete,and avoid the construction challenges of setting up multi-layer and multi-stirrup reinforcement while improving the bearing capacity of section;a new type of double-side and bi-directional anti-skid anchorage device is adopted for the cable saddle of wire divider pipe in order to withstand the unbalanced cable force,and verify the reliability of the anti-skid anchorage device by solid model test;and large-segment cantilever pouring design is adopted for the main girder with a maximum segment length of 8 m to effectively shorten the construction period of the bridge.
文摘Numerical analyses of the coupled vibrations of vehicle-bridge system and the effects of different types of cable stayed bridges on the coupled vibration responses have been presented in this paper using ANSYS. The bridge model and vehicle model were independently built which have no internal relationship in the ANSYS. The vehicle-bridge coupled vibration relationship was obtained by using the APDL program which subsequently imposed on the vehicle and bridge models during the numerical analysis. The proposed model was validated through a field measurements and literature data. The judging method, possibility, and criterion of the vehicle-bridge resonance (coupled vibrations) of cable stayed bridges (both the floating system and half floating system) under traffic flows were presented. The results indicated that the interval time between vehicles is the main influence factor on the resonance excitation frequency under the condition of equally spaced traffic flows. Compared to other types of cable stayed bridges, the floating bridge system has relatively high possibility to cause vehicle-bridge resonance.
基金supported by the National Natural Science Foundation of China (11072212,10932009)the Zhejiang Natural Science Foundation of China (7080070)
文摘A stochastic optimal control strategy for a slightly sagged cable using support motion in the cable axial direction is proposed. The nonlinear equation of cable motion in plane is derived and reduced to the equations for the first two modes of cable vibration by using the Galerkin method. The partially averaged Ito equation for controlled system energy is further derived by applying the stochastic averaging method for quasi-non-integrable Hamiltonian systems. The dynamical programming equation for the controlled system energy with a performance index is established by applying the stochastic dynamical programming principle and a stochastic optimal control law is obtained through solving the dynamical programming equation. A bilinear controller by using the direct method of Lyapunov is introduced. The comparison between the two controllers shows that the proposed stochastic optimal control strategy is superior to the bilinear control strategy in terms of higher control effectiveness and efficiency.
基金the National Natural Science Foundation of China(Nos.51009015 and 51274051)
文摘The major reason of the failure of jointed rock-mass is the formation of the plastic zone near the crack tip ofⅠ-Ⅱmixed crack which leads to the growth,propagation of the branched crack under load condition.In the paper,the failure judgment of mini-plastic zone's displacement is derived by the Mises yielding rule.The anchor cable is simulated by the different link elements and inflicting pre-strains according to the difference of mechanism of the consolidated segment and free segment.The stress and strain fields near crack tip of twain collinear cracks of different angles and consolidated conditions are simulated by iso-parametric element with eight nodes.The iso-parametric element with eight nodes is degenerated to singular element at crick tip to simulate crack.It is shown that the mini plastic zone's displacement near the crack tip begins to increase,then decreases with the increase of the angle of the crack.The better consolidated condition is,the smaller the angle of crack tip is when the mini plastic zone's displacement near the crack tip arrives at the biggest value.The mini plastic zone's displacement near the crack Tip 2 is bigger than that near the crack Tip 3.The crack is easier to failure with the increase of load.
文摘The Millau viaduct over the Tam River is an exceptional bridge considering the height under the deck and the 2.5 km total length. Each of the seven high piers is founded on a thick raft setting on four large piles of 5 m in diameter and 10-15 m deep. The ground schematically consists of limestone in the north and of marls in the south. As the bridge is very sensitive to foundation settlements, the concessionary company decided to use the observational method for controlling the displacements and if necessary stabilize the foundations. The measurements show that the movements have remained small and admissible, particularly in terms of the rotations. The settlements have not occurred continuously under the load, but by steps.