期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
A Biomechanical Comparison of Conventional versus an Anatomic Plate and Compression Bolts for Fixation of Intra-articular Calcaneal Fractures 被引量:6
1
作者 王海立 杨朝旭 +5 位作者 吴战坡 陈伟 张奇 李明 李智勇 张英泽 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2012年第4期571-575,共5页
The purpose of this study was to compare the biomechanical stability obtained by using our technique featured an anatomical plate and compression bolts versus that of the conventional anatomic plate and cancellous scr... The purpose of this study was to compare the biomechanical stability obtained by using our technique featured an anatomical plate and compression bolts versus that of the conventional anatomic plate and cancellous screws in the fixation of intraarticular calcaneal fractures.Eighteen fresh frozen lower limbs of cadavers were used to create a reproductive Sanders type-Ⅲ calcaneal fracture model by using osteotomy.The calcaneus fractures were randomly selected to be fixed either using our anatomical plate and compression bolts or conventional anatomic plate and cancellous screws.Reduction of fracture was evaluated through X radiographs.Each calcaneus was successively loaded at a frequency of 1 Hz for 1000 cycles through the talus using an increasing axial force 20 N to 200 N and 20 N to 700 N,representing the partial weight bearing and full weight bearing,respectively,and then the specimens were loaded to failure.Data extracted from the mechanical testing machine were recorded and used to test for difference in the results with the Wilcoxon signed rank test.No significant difference was found between our fixation technique and conventional technique in displacement during 20-200 N cyclic loading(P=0.06),while the anatomical plate and compression bolts showed a great lower irreversible deformation during 20-700 N cyclic loading(P=0.008).The load achieved at loss of fixation of the constructs for the two groups had significant difference:anatomic plate and compression bolts at 3839.6±152.4 N and anatomic plate and cancellous screws at 3087.3±58.9 N(P=0.008).There was no significant difference between the ultimate displacements.Our technique featured anatomical plate and compression bolts for calcaneus fracture fixation was demonstrated to provide biomechanical stability as good as or better than the conventional anatomic plate and cancellous screws under the axial loading.The study supports the mechanical viability of using our plate and compression bolts for the fixation of calcaneal fracture. 展开更多
关键词 calcaneal fracture anatomic plate fixation compression bolts conventional screws biomechanical testing
下载PDF
Comparisons in finite element analysis of minimally invasive, locking,and non-locking plates systems used in treating calcaneal fractures of Sanders type Ⅱ and type Ⅲ 被引量:12
2
作者 He Kai Fu Su +2 位作者 Liu Song Wang Zhifa Jin Dan 《Chinese Medical Journal》 SCIE CAS CSCD 2014年第22期3894-3901,共8页
Background Calcaneal fractures are relatively common but complex,while the treatment of these fractures is still controversial.The objective of this study was to compare the biomechanical stability of minimally invasi... Background Calcaneal fractures are relatively common but complex,while the treatment of these fractures is still controversial.The objective of this study was to compare the biomechanical stability of minimally invasive,locking,and non-locking plating systems used for fixing Sanders type Ⅱ and type Ⅲ calcaneal fractures.Finite element analysis was used for comparing the three types of plating systems.This study helped in guiding the clinical management of calcaneal fractures.Methods The CT data acquired from a volunteer was used to construct a finite element model of calcaneus.The fracture lines were made according to Sanders type Ⅱ (A,B,C) and type Ⅲ (AB,AC,BC) and six calcaneal fractures models were constructed accordingly.Three fixation methods used in clinical treatment were simulated by design tools (minimally invasive plating with percutaneous screws,Y-size non-locking plating,and locking plating) and then fixed to these fracture models with the help of clinical principles.The single minimally invasive plating fixation was also tested to compare the function of percutaneous screws.Then,the neutral force was applied on established methods.The displacement and presses distribution condition in various plating models were analyzed and compared.Results The levels of displacement and compressive press on the bone around fixation or strains on plating were within the physiological limit,indicating that the three methods were suitable for application.Compared with the locked and unlocked plates,the minimally invasive plating caused a relatively lower displacement without the high stress in bone or fixation.The minimum stress in fixation was observed in locking plate as the distribution of stress was concentrated in the anterior part of locking plate.Conclusions The minimally invasive plating method could be a better alternative method in treating Sanders type Ⅱ and type Ⅲ calcaneal fractures.The observed stiffness of locking plate was not obviously stronger than unlocked plate. 展开更多
关键词 calcaneal fractures Sanders type finite element analysis fixation minimally invasive plate
原文传递
First Ever Documented Total Calcaneus Replacement with 3D Printed Metallic Implant for Chronic Osteomyelitis after a Calcaneal Fracture in a Young, Healthy Individual—A Literature Review and Preliminary Case Report
3
作者 Leslie H. Pyle Mica Murdoch +1 位作者 Ashley McClain Kyle Yi 《Open Journal of Orthopedics》 2023年第5期195-204,共10页
Osteomyelitis of the calcaneus can be a limb threatening diagnosis, which is typically treated with antibiotic therapy with or without partial resection of the bone. Extensive infection of the bone commonly results in... Osteomyelitis of the calcaneus can be a limb threatening diagnosis, which is typically treated with antibiotic therapy with or without partial resection of the bone. Extensive infection of the bone commonly results in limb amputation via transtibial or transfemoral amputation, which can increase morbidity and mortality. This case report involves a 29-year-old male who sustained bilateral calcaneal fracture after a fall, who developed osteomyelitis of the right calcaneus after being treated with internal/external fixation and antibiotic therapy. In order to preserve the limb total calcaneal replacement with 3D printed implant was done. 展开更多
关键词 OSTEOMYELITIS calcaneal Replacement 3D Implant calcaneal Fracture Below Knee Amputation
下载PDF
Fixation of Calcaneal Tuberosity Beavis II Fracture in Elderly Patients Using Locking Plate Combined with Tension Screw
4
作者 De-Jian Li Jia-Wen He +2 位作者 Jian-Hua Zhou Cheng-Qing Yi Qi-Kai Huang 《Biomedical Engineering Communications》 2023年第1期24-28,共5页
Background:Calcaneus is the largest bone of foot and the main load-bearing structure of heel.The incidence of simple calcaneal tubercle avulsion fracture is low,accounting for about 1%to 3%of all calcaneal fractures.B... Background:Calcaneus is the largest bone of foot and the main load-bearing structure of heel.The incidence of simple calcaneal tubercle avulsion fracture is low,accounting for about 1%to 3%of all calcaneal fractures.Beavis II fracture has large bone fracture,obvious displacement,obvious soft tissue irritation,and often leads to skin necrosis.It needs surgical treatment,reduction and fixation as soon as possible.Although open reduction and tension screw internal fixation is used for Beavis II calcaneal tubercle fracture,but the failure rate is more common.Methods:This study retrospectively analyzed the surgical treatment of calcaneal tubercle Beavis II fracture over 55 years old in our hospital from January 2013 to January 2019.The patients were treated with tension screw combined with locking plate,and followed up and analyzed.Results:12 patients in this group were followed up for 12 to 36 months(mean 20 months).After operation,the fracture healed smoothly in all patients,the healing time was 8 to 12 weeks(mean 10.7 weeks),and there were no complications such as poor incision healing,fracture displacement,internal fixation loosening,fracture and so on.When the patients were followed up 18 weeks after operation,the AOFAS score was 47 to 100,with an average of 91.1,of which 8 cases were excellent,3 good and 1 poor,with an excellent and good rate of 91.7%.Conclusion:Our hospital has been treated with tension screw combined with locking plate,fixed firmly,can early functional exercise,achieved good results. 展开更多
关键词 calcaneal tubercle Beavis II fracture locking plate tension screw elderly patients
下载PDF
Operative vs nonoperative treatment of displaced intraarticular calcaneal fracture: A meta-analysis of randomized controlled trials
5
作者 Nan Jiang Hui-Juan Song +4 位作者 Guo-Ping Xie Lei Wang Chang-Xiang Liang Cheng-He Qin Bin Yu 《World Journal of Meta-Analysis》 2015年第1期61-71,共11页
AIM: To investigate clinical efficacy of displaced intraarticular calcaneal fracture(DIACF) following operation and nonoperation. METHODS: Literature search was performed of Pub Med and Cochrane Library by two indepen... AIM: To investigate clinical efficacy of displaced intraarticular calcaneal fracture(DIACF) following operation and nonoperation. METHODS: Literature search was performed of Pub Med and Cochrane Library by two independent authors to identify randomized controlled trials(RCTs) comparing operative vs nonoperative treatment of DIACF from inception to December 31 st, 2013. RCT quality was evaluated by the modified Jadad scale. Dichotomous variables were pooled using risk ratios by review manager 5.3 software. Fixed-effects or randomeffects models were adopted with P > 0.05 or P ≤ 0.05 for heterogeneity tests, respectively.RESULTS: Eight RCTs comprising 767 cases met inclusion criteria. Results revealed that more surgically treated patients could resume pre-injury job(P = 0.006). No statistical differences were found between the two groups in residual pain(P = 0.33), shoe fitting problems(P = 0.07), limited walking distance(P = 0.56) or secondary late arthrodesis(P = 0.38). However, operative treatment was associated with a higher complication rate(P = 0.003). Subgroup analyses of specific complications revealed that except for a higher risk of superficial wound problems(P < 0.0001) in operative group, the two groups had similar complication rate in deep wound infection(P = 0.34),compartment syndrome(P = 0.46), thromboembolism(P = 0.32), reflex sympathetic dystrophy(P = 0.51) or traumatic arthritis secondary to DIACF(P = 0.43).CONCLUSION: Current evidence demonstrates that compared with operative treatment, conservative treatment of DIACF lead to similar clinical outcomes regarding residual pain, shoe fitting, walking distance and secondary subtalar arthrodesis but a significantly lower complication rate. 展开更多
关键词 Displaced intra-articular calcaneal fracture SURGERY Conservative treatment META-ANALYSIS
下载PDF
Ilizarov external fixators for maluninon of obsolete calcaneal fracture of Stephen Type Ⅲ
6
作者 谢鸣 《外科研究与新技术》 2011年第2期114-114,共1页
Objective To evaluate the clinical effects of Ilizarov external fixator for maluninon of obsolete calcaneal fracture of Stephen Type Ⅲ.Methods From July 2006 to February 2009,25 patients suffering from maluninon of o... Objective To evaluate the clinical effects of Ilizarov external fixator for maluninon of obsolete calcaneal fracture of Stephen Type Ⅲ.Methods From July 2006 to February 2009,25 patients suffering from maluninon of obsolete calcaneal 展开更多
关键词 Ilizarov external fixators for maluninon of obsolete calcaneal fracture of Stephen Type
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部