With the continuous development of urban distribution network, most of the distribution network has formed a dual power supply mode. The traditional way of distribution network load operating mainly adopts the power m...With the continuous development of urban distribution network, most of the distribution network has formed a dual power supply mode. The traditional way of distribution network load operating mainly adopts the power method, while satisfied the requirements of the safety of power grid, but will cause external short time power outages, poor user experience, realizing the distribution network outage rearrangement of load is a necessary means to improve power supply reliability. This paper presents mathematical model of load transfer in distribution network. The differences of voltage of amplitude and phase angle on both sides are calculated by the power flow. According to the differential pressure to determine whether the loop can be closed at the loop operation, thereby improving the success rate of operation.展开更多
双电源配电环网是实现配电网故障无缝自愈、有效解决短时停电问题的基础,但配电环网中潮流呈自然分布,且缺乏有效的调节手段,统一潮流控制器(unified power flowcontroller,UPFC)可对环网潮流进行控制,但需突破其经济性瓶颈。为此,在调...双电源配电环网是实现配电网故障无缝自愈、有效解决短时停电问题的基础,但配电环网中潮流呈自然分布,且缺乏有效的调节手段,统一潮流控制器(unified power flowcontroller,UPFC)可对环网潮流进行控制,但需突破其经济性瓶颈。为此,在调节功率一定时,以负荷节点电压与环网两端馈线出力极限为约束条件,分别以UPFC输出的有功功率和视在功率最小为目标,提出了潮流控制策略。仿真结果表明2种优化控制策略能够满足配电环网潮流调度要求,且兼顾了UPFC应用的经济性。展开更多
目前国内绝大部分220/110 k V电磁环网采取开环运行的方式。电磁环网闭环运行时涉及的各个电压等级的短路电流可能出现超标是导致220/110 k V电磁环网"一刀切"式的解环运行的重要因素。以湖南电网220/110 k V电磁环网为例,分...目前国内绝大部分220/110 k V电磁环网采取开环运行的方式。电磁环网闭环运行时涉及的各个电压等级的短路电流可能出现超标是导致220/110 k V电磁环网"一刀切"式的解环运行的重要因素。以湖南电网220/110 k V电磁环网为例,分析220/110 k V电磁环网开、闭环运行对短路电流的影响,并探讨极端状态下短路电流的变化情况。以此为基础,归纳出220/110 k V电磁环网闭环运行时短路电流变化的典型结论,该研究成果为合理确定220/110 k V电网电磁环网的闭环运行可行性提供重要依据。展开更多
为满足统一潮流控制器(UPFC)的控制保护系统的产品研发、策略验证及设备出厂试验等需求,需搭建一套能够真实模拟工程落点复杂电网、UPFC本体及相关联的关键设备、且能够同时接入多专业二次装置的闭环试验系统。文章以苏州南部500k V电网...为满足统一潮流控制器(UPFC)的控制保护系统的产品研发、策略验证及设备出厂试验等需求,需搭建一套能够真实模拟工程落点复杂电网、UPFC本体及相关联的关键设备、且能够同时接入多专业二次装置的闭环试验系统。文章以苏州南部500k V电网UPFC示范工程为背景,首先介绍了该工程的概况;其次详细介绍了RTDS(real time digital simulator)模型的搭建过程,包括复杂交流电网、MMC阀组、串/并联变压器、直流母线、避雷器等关键设备以及各类故障模拟等,给出了模型的处理器资源分配;然后介绍了仿真试验系统的连接;最后结合苏南UPFC示范工程的应用,给出了系统解锁和有功功率阶跃的实验结果。实验结果表明,仿真试验系统能够真实地模拟复杂交流电压、UPFC本体等特性,可为UPFC控制保护系统的产品研发、策略验证以及设备出厂试验提供一个良好的检验平台。展开更多
文摘With the continuous development of urban distribution network, most of the distribution network has formed a dual power supply mode. The traditional way of distribution network load operating mainly adopts the power method, while satisfied the requirements of the safety of power grid, but will cause external short time power outages, poor user experience, realizing the distribution network outage rearrangement of load is a necessary means to improve power supply reliability. This paper presents mathematical model of load transfer in distribution network. The differences of voltage of amplitude and phase angle on both sides are calculated by the power flow. According to the differential pressure to determine whether the loop can be closed at the loop operation, thereby improving the success rate of operation.
文摘双电源配电环网是实现配电网故障无缝自愈、有效解决短时停电问题的基础,但配电环网中潮流呈自然分布,且缺乏有效的调节手段,统一潮流控制器(unified power flowcontroller,UPFC)可对环网潮流进行控制,但需突破其经济性瓶颈。为此,在调节功率一定时,以负荷节点电压与环网两端馈线出力极限为约束条件,分别以UPFC输出的有功功率和视在功率最小为目标,提出了潮流控制策略。仿真结果表明2种优化控制策略能够满足配电环网潮流调度要求,且兼顾了UPFC应用的经济性。
文摘目前国内绝大部分220/110 k V电磁环网采取开环运行的方式。电磁环网闭环运行时涉及的各个电压等级的短路电流可能出现超标是导致220/110 k V电磁环网"一刀切"式的解环运行的重要因素。以湖南电网220/110 k V电磁环网为例,分析220/110 k V电磁环网开、闭环运行对短路电流的影响,并探讨极端状态下短路电流的变化情况。以此为基础,归纳出220/110 k V电磁环网闭环运行时短路电流变化的典型结论,该研究成果为合理确定220/110 k V电网电磁环网的闭环运行可行性提供重要依据。
文摘为满足统一潮流控制器(UPFC)的控制保护系统的产品研发、策略验证及设备出厂试验等需求,需搭建一套能够真实模拟工程落点复杂电网、UPFC本体及相关联的关键设备、且能够同时接入多专业二次装置的闭环试验系统。文章以苏州南部500k V电网UPFC示范工程为背景,首先介绍了该工程的概况;其次详细介绍了RTDS(real time digital simulator)模型的搭建过程,包括复杂交流电网、MMC阀组、串/并联变压器、直流母线、避雷器等关键设备以及各类故障模拟等,给出了模型的处理器资源分配;然后介绍了仿真试验系统的连接;最后结合苏南UPFC示范工程的应用,给出了系统解锁和有功功率阶跃的实验结果。实验结果表明,仿真试验系统能够真实地模拟复杂交流电压、UPFC本体等特性,可为UPFC控制保护系统的产品研发、策略验证以及设备出厂试验提供一个良好的检验平台。