期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Accurate determination of calibration factor for tidal gravity observation of a GWR-superconducting gravimeter 被引量:1
1
作者 孙和平 陈晓东 +1 位作者 许厚泽 王勇 《Acta Seismologica Sinica(English Edition)》 EI CSCD 2001年第6期692-700,共9页
It is recognized widely nowadays that the superconducting gravimeter (SG) is a kind of best relative gravimeter with high observing precision, good continuity and stability. However, it is necessary to calibrate the d... It is recognized widely nowadays that the superconducting gravimeter (SG) is a kind of best relative gravimeter with high observing precision, good continuity and stability. However, it is necessary to calibrate the direct output (change in voltage) by using scale value (calibration factor) before getting the change of the real gravity field. Studies show that the accuracy of the scale value will influence the late analysis and explanation of the observations. By using absolute gravity measurements of a FG5 absolute gravimeter (AG) at Wuhan international tidal gravity fundamental station (two campaigns each for 3 days) and by using known tidal parameters at the same station, the calibration factors of the SG and their precision are studied in detail in this paper. 展开更多
关键词 superconducting gravimeter absolute gravimeter tidal observation calibration factor preci-sion analysis
下载PDF
Functional Confirmation Using a Medical X-Ray System of a Semiconductor Survey Meter
2
作者 Katsunao Suzuki Toru Negishi +2 位作者 Yoh Kato Yasuhisa Kono Michiharu Sekimoto 《Open Journal of Radiology》 2024年第1期1-13,共13页
In recent years, semiconductor survey meters have been developed and are in increasing demand worldwide. This study determined if it is possible to use the X-ray system installed in each medical facility to calculate ... In recent years, semiconductor survey meters have been developed and are in increasing demand worldwide. This study determined if it is possible to use the X-ray system installed in each medical facility to calculate the time constant of a semiconductor survey meter and confirm the meter’s function. An additional filter was attached to the medical X-ray system to satisfy the standards of N-60 to N-120, more copper plates were added as needed, and the first and second half-value layers were calculated to enable comparisons of the facility’s X-ray system quality with the N-60 to N-120 quality values. Next, we used a medical X-ray system to measure the leakage dose and calculate the time constant of the survey meter. The functionality of the meter was then checked and compared with the energy characteristics of the meter. The experimental results showed that it was possible to use a medical X-ray system to reproduce the N-60 to N-120 radiation quality values and to calculate the time constant from the measured results, assuming actual leakage dosimetry for that radiation quality. We also found that the calibration factor was equivalent to that of the energy characteristics of the survey meter. 展开更多
关键词 Semiconductor Survey Meter Functional Confirmation Medical X-Ray System calibration factor Time Constant
下载PDF
Calibration of a neutron dose rate meter in various neutron standard fields 被引量:1
3
作者 Tuan Khai Nguyen Hoai-Nam Tran +4 位作者 Quynh Ngoc Nguyen Thi My Linh Dang Van Loat Bui Thiansin Liamsuwan Ngoc-Thiem Le 《Nuclear Science and Techniques》 SCIE CAS CSCD 2020年第6期75-82,共8页
This paper presents the calibration of a neutron dose rate meter and the evaluation of its calibration factors(CFs)in several neutron standard fields(i.e.,two standard fields with bare sources of252Cf and241Am-Be,and ... This paper presents the calibration of a neutron dose rate meter and the evaluation of its calibration factors(CFs)in several neutron standard fields(i.e.,two standard fields with bare sources of252Cf and241Am-Be,and five simulated workplace fields with241Am-Be moderated sources).The calibration in standard fields with bare sources was conducted by following the recommendations of the ISO 8529 standard.The measured total neutron ambient dose equivalent rates,denoted as H*(10)tot,were analyzed to obtain direct components,denoted as H*(10)dir,using a reduced fitting method.The CF was then calculated as the ratio between the conventional true value of the neutron ambient dose equivalent rate in a free field,denoted as H*(10)FF,and the value of H*(10)dir.In contrast,in the simulated workplace neutron fields,the calibration of the neutron dose rate meter was conducted by following the ISO 12789 standard.The CF was calculated as the ratio between the values of H*(10)totmeasured by a standard instrument(i.e.,Bonner sphere spectrometer)and the neutron dose rate meter.The CF values were obtained in the range of 0.88–1.0.The standard uncertainties(k=1)of the CFs were determined to be in the range of approximately 6.6–13.1%. 展开更多
关键词 Neutron standard fields Neutron dose rate meter calibration factor 252Cf source 241AmBe source
下载PDF
Comparative Alpha Tracks Counting Using an Optical Microscope and a Spark Counter
4
作者 Dabo S. I. Agba Ponaho Kezo Issa Konaté 《Detection》 2023年第2期7-18,共12页
In the metrology of radon, an environmental lung carcinogen, the integrated measurements necessary for epidemiological studies are made very often using the tracks detector LR 115 type 2. For dosimetric analysis, the ... In the metrology of radon, an environmental lung carcinogen, the integrated measurements necessary for epidemiological studies are made very often using the tracks detector LR 115 type 2. For dosimetric analysis, the etched tracks from radon alpha particles on this detector are usually counted by means of an optical microscope or a spark counter. An optimal reading of the track densities which must be converted into radon concentrations, can’t be done without a good mastery of the mode of operation and use of these devices. Furthermore, investigations to know as to whether or not each of those can be used to determine radon concentration are necessary. These are the objectives of the present work in which LR 115 samples exposed to radon for at least 3 months, were chemically developed under standard conditions and read. The track densities obtained with the microscope are very much higher than those of the counter for each sample. These results are consistent with those published by other authors. However, each of these devices can be used interchangeably for alpha tracks counting, as both provide radon concentrations with a very good linear correlation coefficient of 0.95 taking into account their respective calibration factors for the reading of this detector. In addition, the saturation phenomenon for the spark counter reading of LR 115 detector occurs beyond 11,000 tr/cm<sup>2</sup>, a density never reached during our environmental radon measurements. 展开更多
关键词 LR 115 Detector Optical Microscope Spark Counter Alpha Track Density calibration factor Radon Concentration
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部