期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Research on Consistency Judgement of Indication Error for Calibration Result of Humidity Sensor in Meteorology
1
作者 Mingming Wei Fen Li Jie Miao 《Atmospheric and Climate Sciences》 2022年第1期43-53,共11页
In order to solve the lack of relevant evaluation research on the accuracy of HMP155A humidity sensor calibration results in the past, this paper designs the corresponding experimental scheme, and obtains the correspo... In order to solve the lack of relevant evaluation research on the accuracy of HMP155A humidity sensor calibration results in the past, this paper designs the corresponding experimental scheme, and obtains the corresponding calibration results according to the experimental scheme;Then the measurement uncertainty of the indication error in the calibration results is evaluated by GUM, and the corresponding extended uncertainty </span><i><span style="font-family:Verdana;">U</span></i><sub><span style="font-family:Verdana;">95</span></sub><span style="font-family:Verdana;"> is obtained. Finally, according to the requirements of JJF1094-2016 characteristic evaluation of measuring instruments, combined with the calibration results and the actual situation of </span><i><span style="font-family:Verdana;">U</span></i><sub><span style="font-family:Verdana;">95</span></sub><span style="font-family:Verdana;">, the conformity of the indication error of calibration is determined. The result is that each calibration point of the sensor meets the requirements of conformity determination and is within the qualified range. This research effectively makes up for the blank of the previous research on the conformity determination of the indication error of the calibration results and has strong theoretical and practical significance. 展开更多
关键词 Humidity Sensor calibration results Indication Error Measurement Uncertainty
下载PDF
Colorimetric enantiodiscrimination of mandelic acid by indicator displacement assay 被引量:1
2
作者 Xue-Xian Chen Li-Ming Yuan 《Chinese Chemical Letters》 SCIE CAS CSCD 2015年第8期1019-1021,共3页
The colorimetric enantiodiscrimination between mandelic acid and L-proline-Cu(II) is exploited to develop enantioselective indicator displacement assays. The sensitivity of the assay could be tuned by using a colori... The colorimetric enantiodiscrimination between mandelic acid and L-proline-Cu(II) is exploited to develop enantioselective indicator displacement assays. The sensitivity of the assay could be tuned by using a colorimetric indicator. The chromophoric ligand, pyrocatechol violet, effectively competes with the mandelic acid guest for open coordination sites on L-proline-Cu(II). The △A could be increased to 0.12 by changing the ratio of(+)- and(-)-mandelic acid concentrations that were found to be optimal from the displacement experiments. The resultant enantiomer excess versus △A relationship is linear. From the calibration curves, the absorbance values of the unknowns may be calculated for the enantiomeric excess value and the colorimetric enantiodiscrimination of mandelic acid can thus be obtained. 展开更多
关键词 proline indicator reserved resultant calibration excess violet guest isotherm tuned
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部