Correction to:Nuclear Science and Techniques(2024)35:145 https://doi.org/10.1007/s41365-024-01517-y In this article the author’s name Wan-Bing He was incorrectly written as Wan-Bin He.The original article has been co...Correction to:Nuclear Science and Techniques(2024)35:145 https://doi.org/10.1007/s41365-024-01517-y In this article the author’s name Wan-Bing He was incorrectly written as Wan-Bin He.The original article has been corrected.展开更多
The sensitivity of the dark photon search through invisible decay final states in low-background experiments relies sig-nificantly on the neutron and muon veto efficiencies,which depend on the amount of material used ...The sensitivity of the dark photon search through invisible decay final states in low-background experiments relies sig-nificantly on the neutron and muon veto efficiencies,which depend on the amount of material used and the design of the detector geometry.This paper presents the optimized design of the hadronic calorimeter(HCAL)used in the DarkSHINE experiment,which is studied using a GEANT4-based simulation framework.The geometry is optimized by comparing a traditional design with uniform absorbers to one that uses different thicknesses at different locations on the detector,which enhances the efficiency of vetoing low-energy neutrons at the sub-GeV level.The overall size and total amount of material used in the HCAL are optimized to be lower,owing to the load and budget requirements,whereas the overall performance is studied to satisfy the physical objectives.展开更多
The sPHENIX experiment is a new generation of large acceptance detectors at the relativistic heavy ion collider at Brookhaven National Laboratory,with scientific goals focusing on probing the strongly interacting Quar...The sPHENIX experiment is a new generation of large acceptance detectors at the relativistic heavy ion collider at Brookhaven National Laboratory,with scientific goals focusing on probing the strongly interacting Quark–Gluon plasma with hard probes of jets,open heavy flavor particles,andγproduction.The EMCal detector,which covers the pseudo-rapidity region of|η|≤1.1,is an essential subsystem of sPHENIX.In this study,we focused on producing and testing EMCal blocks covering a pseudo-rapidity of|η|∈[0.8,1.1].These,in conjunction with the central pseudo-rapidity EMCal blocks,significantly enhance the sPHENIX physics capability of the jet andγparticle measurements.In this paper,the detector module production and testing of sPHENIX W-powder/scintillating fiber(W/ScFi)electromagnetic calorimeter blocks are presented.The selection of the tungsten powder,mold fabrication,QA procedures,and cosmic ray test results are discussed.展开更多
The stability constants and thermodynamic functions for complexes of lanthanum with eight kind of amino acids according to 1∶1 and 1∶2 in proportion have been determined by titration calorimeter at 298.15 K. The ent...The stability constants and thermodynamic functions for complexes of lanthanum with eight kind of amino acids according to 1∶1 and 1∶2 in proportion have been determined by titration calorimeter at 298.15 K. The enthalpy change makes a predominant contribution to the stability of these complexes. The ring in amino acid associated with lanthanum ion helps to enhance the stability of complexes. Steric effects between rings in complexes leads to that the equilibrium constants of reaction of the complexes (1∶2) is much less than that of the complexes (1∶1).展开更多
This paper describes a method for energy calibration of laterally segmented electromagnetic calorimeters based on the detection of two-photon decays of π~0 mesons.The calibration procedure performs a X^2 function min...This paper describes a method for energy calibration of laterally segmented electromagnetic calorimeters based on the detection of two-photon decays of π~0 mesons.The calibration procedure performs a X^2 function minimization between the measured π~0 energy in the calorimeter and its expected energy deduced from the π~0 momentum direction. The performance of this technique is demonstrated with a Monte Carlo simulation of an experimental case where biased calibration coefficients are employed. The real calibration coefficients are restored with less than 1% relative accuracy when a sufficient number of π~0 is detected. This technique is applied to monitor daily the calibration coefficients of the calorimeter used in the Jefferson Lab Hall A DVCS experiments.展开更多
In order to design the relief system size of di-tert-butyl peroxide(DTBP) storage tanks,the runaway re-action of DTBP was simulated by accelerating rate calorimeter(ARC).The results indicated that under adiabatic cond...In order to design the relief system size of di-tert-butyl peroxide(DTBP) storage tanks,the runaway re-action of DTBP was simulated by accelerating rate calorimeter(ARC).The results indicated that under adiabatic conditions the initial exothermic temperature was 102.6 ℃,the maximum self-heating rate was 3.095×107 ℃·min-1,the maximum self-heating temperature was 375.9 ℃,and the pressure produced by unit mass was 4.512 MPa·g-1.Judged by ARC test,the emergency relief system for DTBP was a hybrid system.Based on Design Institute for Emergency Relief System(DIERS) method,the releasing mass flow rate W was determined by Leung methods,and the mass velocity G was calculated by two modified Omega methods.The two relief sizes calculated by monograph Omega method and arithmetic Omega method are close,with only 0.63% relative error.The monograph Omega method is more convenient to apply.展开更多
In the future, the Very Large Area gamma-ray Space Telescope is expected to observe high-energy electrons and gamma rays in the MeV to TeV range with unprecedented acceptance. As part of the detector suite, a high-ene...In the future, the Very Large Area gamma-ray Space Telescope is expected to observe high-energy electrons and gamma rays in the MeV to TeV range with unprecedented acceptance. As part of the detector suite, a high-energy imaging calorimeter(HEIC) is currently being developed as a homogeneous calorimeter that utilizes long bismuth germanate(BGO) scintillation crystals as both absorbers and detectors. To accurately measure the energy deposition in the BGO bar of HEIC, a highdynamic-range readout method using a silicon photomultiplier(SiPM) and multiphotodiode(PD) with different active areas has been proposed. A prototype readout system that adopts multichannel charge measurement ASICs was also developed to read out the combined system of SiPMs and PDs. Preliminary tests confirmed the feasibility of the readout scheme, which is expected to have a dynamic range close to 10~6.展开更多
The accelerating rate calorimeter was applied to study the thermal hazard of two kinds of organic peroxides, i.e. methyl ethyl ketone peroxide (MEKPO) and benzoyl peroxide (BPO). And their thermal decomposition charac...The accelerating rate calorimeter was applied to study the thermal hazard of two kinds of organic peroxides, i.e. methyl ethyl ketone peroxide (MEKPO) and benzoyl peroxide (BPO). And their thermal decomposition characteristics were discussed. Meanwhile, thermal decomposition characteristics of MEKPO and BPO vvere compared. The result indicated that MEKPO is more sensitive to thermal effect than BPO. While once the thermal decomposition takes place. BPO will be more hazardous than MEKPO due to its serious pressure effect. Thermal kinetic analysis of these two kinds of organic peroxides was also taken, and the kinetic parameters for them were calculated. The study of thermal decomposition of MEKPO solution with different initial concentrations indicated that, the lower concentration MEKPO solution is, the higher onset temperature will be. And with the addition of organic solvent, it becomes more difficult for MEKPO to reach a thermal decomposition. Therefore, its thermal hazard is reduced.展开更多
The DArk Matter Particle Explorer(DAMPE)is a satellite-borne detector for high-energy cosmic rays and y-rays.To fully understand the detector performance and obtain reliable physical results,extensive simulations of t...The DArk Matter Particle Explorer(DAMPE)is a satellite-borne detector for high-energy cosmic rays and y-rays.To fully understand the detector performance and obtain reliable physical results,extensive simulations of the detector are necessary.The simulations are particularly important for the data analysis of cosmic ray nuclei,which relies closely on the hadronic and nuclear interactions of particles in the detector material.Widely adopted simulation softwares include the GEANT4 and FLUKA,both of which have been implemented for the DAMPE simulation tool.Here we describe the simulation tool of DAMPE and compare the results of proton shower properties in the calorimeter from the two simulation softwares.Such a comparison gives an estimate of the most significant uncertainties of our proton spectral analysis.展开更多
The Cooling Storage Ring external-target experiment(CEE)spectrometer is used to study the nuclear matter created in heavy-ion collisions at√sNN=2.1-2.4 GeV with the aim to reveal the quantum chromodynamics phase stru...The Cooling Storage Ring external-target experiment(CEE)spectrometer is used to study the nuclear matter created in heavy-ion collisions at√sNN=2.1-2.4 GeV with the aim to reveal the quantum chromodynamics phase structure in the high-baryon-density region.Collective flow is considered an effective probe for evaluating the properties of media during high-energy nuclear collisions.One of the main functions of the zero-degree calorimeter(ZDC),a subdetector system in the CEE,is to determine the reaction plane in heavy-ion collisions.This step is crucial for measuring the collective flow and other reaction-plane-related analyses.In this paper,we illustrate the procedures for event plane determination using the ZDC.Finally,isospin-dependent quantum molecular dynamics model-based predictions of the rapidity dependence of the directed and elliptical flows for p,d,t,3He,and 4He,produced in 2.1 GeV U+U collisions,are presented.展开更多
A readout system for ground-based tests of the bismuth germanium oxide(BGO) calorimeter of the Dark Matter Particle Explorer satellite is described in this paper.The system mainly consists of a data acquisition board ...A readout system for ground-based tests of the bismuth germanium oxide(BGO) calorimeter of the Dark Matter Particle Explorer satellite is described in this paper.The system mainly consists of a data acquisition board with a field-programmable gate array to implement the control logic, and a graphical user interface software based on LabWindows/CVI. The system has been successfully applied in a series of ground-based environmental experiments and almost all the performance tests throughout the entire manufacturing processes. These contribute significantly to the development of the BGO calorimeter before being submitted for satellite-level integration.展开更多
The zero degree calorimeter(ZDC) at RHICSTAR was installed in the year 2000.After running for more than 10 years,the performance of the STAR-ZDC cannot maintain a proper status because of the radiation damage.The ZDC ...The zero degree calorimeter(ZDC) at RHICSTAR was installed in the year 2000.After running for more than 10 years,the performance of the STAR-ZDC cannot maintain a proper status because of the radiation damage.The ZDC on RHIC-BRAHMS had been moved to STAR in 2011 after some tests.We present here the result of the tests as well as the physical performance of those ZDC modules between the 2011 and 2015 RHIC runs.The excellent energy resolution of the ZDC in heavy ion collision provides a good candidate for future detector development,such as the CSR experiment at CAS-Lanzhou facility.展开更多
eCall是欧盟计划在2015年完成部署的一套车载自动紧急呼叫系统,在发生严重交通事故后,即使司机和乘客失去知觉不能拨打电话,这一系统也能够自动拨叫欧洲统一的紧急救援电话112,并报告事故车辆所处的位置。罗德与施瓦茨公司的R&S?CMW...eCall是欧盟计划在2015年完成部署的一套车载自动紧急呼叫系统,在发生严重交通事故后,即使司机和乘客失去知觉不能拨打电话,这一系统也能够自动拨叫欧洲统一的紧急救援电话112,并报告事故车辆所处的位置。罗德与施瓦茨公司的R&S?CMW500和R&S?SMBV100A仪表,配合R&S?CMWKA094 e Call应用软件,为客户提供了一套理想的e Call车载系统可靠性测试方案。展开更多
文摘Correction to:Nuclear Science and Techniques(2024)35:145 https://doi.org/10.1007/s41365-024-01517-y In this article the author’s name Wan-Bing He was incorrectly written as Wan-Bin He.The original article has been corrected.
基金supported by National Key R&D Program of China(Nos.2023YFA1606904 and 2023YFA1606900)National Natural Science Foundation of China(No.12150006)Shanghai Pilot Program for Basic Research-Shanghai Jiao Tong University(No.21TQ1400209).
文摘The sensitivity of the dark photon search through invisible decay final states in low-background experiments relies sig-nificantly on the neutron and muon veto efficiencies,which depend on the amount of material used and the design of the detector geometry.This paper presents the optimized design of the hadronic calorimeter(HCAL)used in the DarkSHINE experiment,which is studied using a GEANT4-based simulation framework.The geometry is optimized by comparing a traditional design with uniform absorbers to one that uses different thicknesses at different locations on the detector,which enhances the efficiency of vetoing low-energy neutrons at the sub-GeV level.The overall size and total amount of material used in the HCAL are optimized to be lower,owing to the load and budget requirements,whereas the overall performance is studied to satisfy the physical objectives.
基金supported by the National Key R&D Program from the Ministry of Science and Technology of China(Nos.2019YFE0114300 and 2022YFA1604900)the National Natural Science Foundation of China(No.11905036)+1 种基金the STCSM(No.23590780100)the Strategic Priority Research Program of Chinese Academy of Sciences(No.XDB34030200)。
文摘The sPHENIX experiment is a new generation of large acceptance detectors at the relativistic heavy ion collider at Brookhaven National Laboratory,with scientific goals focusing on probing the strongly interacting Quark–Gluon plasma with hard probes of jets,open heavy flavor particles,andγproduction.The EMCal detector,which covers the pseudo-rapidity region of|η|≤1.1,is an essential subsystem of sPHENIX.In this study,we focused on producing and testing EMCal blocks covering a pseudo-rapidity of|η|∈[0.8,1.1].These,in conjunction with the central pseudo-rapidity EMCal blocks,significantly enhance the sPHENIX physics capability of the jet andγparticle measurements.In this paper,the detector module production and testing of sPHENIX W-powder/scintillating fiber(W/ScFi)electromagnetic calorimeter blocks are presented.The selection of the tungsten powder,mold fabrication,QA procedures,and cosmic ray test results are discussed.
基金Supported by the National Nature Science Foundation of China(29873036)
文摘The stability constants and thermodynamic functions for complexes of lanthanum with eight kind of amino acids according to 1∶1 and 1∶2 in proportion have been determined by titration calorimeter at 298.15 K. The enthalpy change makes a predominant contribution to the stability of these complexes. The ring in amino acid associated with lanthanum ion helps to enhance the stability of complexes. Steric effects between rings in complexes leads to that the equilibrium constants of reaction of the complexes (1∶2) is much less than that of the complexes (1∶1).
文摘This paper describes a method for energy calibration of laterally segmented electromagnetic calorimeters based on the detection of two-photon decays of π~0 mesons.The calibration procedure performs a X^2 function minimization between the measured π~0 energy in the calorimeter and its expected energy deduced from the π~0 momentum direction. The performance of this technique is demonstrated with a Monte Carlo simulation of an experimental case where biased calibration coefficients are employed. The real calibration coefficients are restored with less than 1% relative accuracy when a sufficient number of π~0 is detected. This technique is applied to monitor daily the calibration coefficients of the calorimeter used in the Jefferson Lab Hall A DVCS experiments.
文摘In order to design the relief system size of di-tert-butyl peroxide(DTBP) storage tanks,the runaway re-action of DTBP was simulated by accelerating rate calorimeter(ARC).The results indicated that under adiabatic conditions the initial exothermic temperature was 102.6 ℃,the maximum self-heating rate was 3.095×107 ℃·min-1,the maximum self-heating temperature was 375.9 ℃,and the pressure produced by unit mass was 4.512 MPa·g-1.Judged by ARC test,the emergency relief system for DTBP was a hybrid system.Based on Design Institute for Emergency Relief System(DIERS) method,the releasing mass flow rate W was determined by Leung methods,and the mass velocity G was calculated by two modified Omega methods.The two relief sizes calculated by monograph Omega method and arithmetic Omega method are close,with only 0.63% relative error.The monograph Omega method is more convenient to apply.
基金Foundation of China (Nos. 12227805, U1831206, 12103095, 12235012, 12273120, and 11973097)the Scientific Instrument Developing Project of the Chinese Academy of Sciences (No. GJJSTD20210009)。
文摘In the future, the Very Large Area gamma-ray Space Telescope is expected to observe high-energy electrons and gamma rays in the MeV to TeV range with unprecedented acceptance. As part of the detector suite, a high-energy imaging calorimeter(HEIC) is currently being developed as a homogeneous calorimeter that utilizes long bismuth germanate(BGO) scintillation crystals as both absorbers and detectors. To accurately measure the energy deposition in the BGO bar of HEIC, a highdynamic-range readout method using a silicon photomultiplier(SiPM) and multiphotodiode(PD) with different active areas has been proposed. A prototype readout system that adopts multichannel charge measurement ASICs was also developed to read out the combined system of SiPMs and PDs. Preliminary tests confirmed the feasibility of the readout scheme, which is expected to have a dynamic range close to 10~6.
文摘The accelerating rate calorimeter was applied to study the thermal hazard of two kinds of organic peroxides, i.e. methyl ethyl ketone peroxide (MEKPO) and benzoyl peroxide (BPO). And their thermal decomposition characteristics were discussed. Meanwhile, thermal decomposition characteristics of MEKPO and BPO vvere compared. The result indicated that MEKPO is more sensitive to thermal effect than BPO. While once the thermal decomposition takes place. BPO will be more hazardous than MEKPO due to its serious pressure effect. Thermal kinetic analysis of these two kinds of organic peroxides was also taken, and the kinetic parameters for them were calculated. The study of thermal decomposition of MEKPO solution with different initial concentrations indicated that, the lower concentration MEKPO solution is, the higher onset temperature will be. And with the addition of organic solvent, it becomes more difficult for MEKPO to reach a thermal decomposition. Therefore, its thermal hazard is reduced.
基金Supported by the National Key Research and Development Program of China(Grant No.2016YFA0400200)the National Natural Science Foundation of China(Grant Nos.11722328,11773085,U1738127,U1738138,U1738205,U1738207,and 11851305)+4 种基金the 100 Talents Program of Chinese Academy of Sciencesthe Youth Innovation Promotion Association CASthe Program for Innovative Talents and Entrepreneur in Jiangsusupported by the Swiss National Science Foundation(SNSF),Switzerlandthe National Institute for Nuclear Physics(INFN),Italy。
文摘The DArk Matter Particle Explorer(DAMPE)is a satellite-borne detector for high-energy cosmic rays and y-rays.To fully understand the detector performance and obtain reliable physical results,extensive simulations of the detector are necessary.The simulations are particularly important for the data analysis of cosmic ray nuclei,which relies closely on the hadronic and nuclear interactions of particles in the detector material.Widely adopted simulation softwares include the GEANT4 and FLUKA,both of which have been implemented for the DAMPE simulation tool.Here we describe the simulation tool of DAMPE and compare the results of proton shower properties in the calorimeter from the two simulation softwares.Such a comparison gives an estimate of the most significant uncertainties of our proton spectral analysis.
基金the National Key Research and Development Program of China(Nos.2022YFA1604900 and 2020YFE0202002)the National Natural Science Foundation of China(Nos.12175084,11890710,11890711,11927901)+1 种基金the Strategic Priority Research Program of the Chinese Academy of Sciences(No.XDB34030000)Fundamental Research Funds for Central Universities(No.CCNU220N003).
文摘The Cooling Storage Ring external-target experiment(CEE)spectrometer is used to study the nuclear matter created in heavy-ion collisions at√sNN=2.1-2.4 GeV with the aim to reveal the quantum chromodynamics phase structure in the high-baryon-density region.Collective flow is considered an effective probe for evaluating the properties of media during high-energy nuclear collisions.One of the main functions of the zero-degree calorimeter(ZDC),a subdetector system in the CEE,is to determine the reaction plane in heavy-ion collisions.This step is crucial for measuring the collective flow and other reaction-plane-related analyses.In this paper,we illustrate the procedures for event plane determination using the ZDC.Finally,isospin-dependent quantum molecular dynamics model-based predictions of the rapidity dependence of the directed and elliptical flows for p,d,t,3He,and 4He,produced in 2.1 GeV U+U collisions,are presented.
基金supported by the Strategic Priority Research Program on Space Science of Chinese Academy of Sciences(No.XDA04040202-4)the National Basic Research Program(973 Program)of China(No.2010CB833002)
文摘A readout system for ground-based tests of the bismuth germanium oxide(BGO) calorimeter of the Dark Matter Particle Explorer satellite is described in this paper.The system mainly consists of a data acquisition board with a field-programmable gate array to implement the control logic, and a graphical user interface software based on LabWindows/CVI. The system has been successfully applied in a series of ground-based environmental experiments and almost all the performance tests throughout the entire manufacturing processes. These contribute significantly to the development of the BGO calorimeter before being submitted for satellite-level integration.
基金supported by the Major State Basic Research Development Program in China(2014CB845400)the National Natural Science Foundation of China(Nos.11421505,11520101004,11322547,and 11275250)
文摘The zero degree calorimeter(ZDC) at RHICSTAR was installed in the year 2000.After running for more than 10 years,the performance of the STAR-ZDC cannot maintain a proper status because of the radiation damage.The ZDC on RHIC-BRAHMS had been moved to STAR in 2011 after some tests.We present here the result of the tests as well as the physical performance of those ZDC modules between the 2011 and 2015 RHIC runs.The excellent energy resolution of the ZDC in heavy ion collision provides a good candidate for future detector development,such as the CSR experiment at CAS-Lanzhou facility.
文摘eCall是欧盟计划在2015年完成部署的一套车载自动紧急呼叫系统,在发生严重交通事故后,即使司机和乘客失去知觉不能拨打电话,这一系统也能够自动拨叫欧洲统一的紧急救援电话112,并报告事故车辆所处的位置。罗德与施瓦茨公司的R&S?CMW500和R&S?SMBV100A仪表,配合R&S?CMWKA094 e Call应用软件,为客户提供了一套理想的e Call车载系统可靠性测试方案。