Here,a styrene-based polymer monolithic column poly(VBS-co-TAT-co-AHM)with reversed-phase/hydrophilic interaction liquid chromatography(RPLC/HILIC)bifunctional separation mode was success-fully prepared for capillary ...Here,a styrene-based polymer monolithic column poly(VBS-co-TAT-co-AHM)with reversed-phase/hydrophilic interaction liquid chromatography(RPLC/HILIC)bifunctional separation mode was success-fully prepared for capillary electrochromatography by the in situ polymerization of sodium p-styrene sulfonate(VBS)with cross-linkers 3-(acryloyloxy)-2-hydroxypropyl methacrylate(AHM)and 1,3,5-triacryloylhexahydro-1,3,5-triazine(TAT).The preparation conditions of the monolith were optimized.The morphology and formation of the poly(VBS-co-TAT-co-AHM)monolith were confirmed by scanning electron microscopy(SEM)and Fourier transform infrared spectroscopy(FT-IR).The separation perfor-mances of the monolith were evaluated systematically.It should be noted that the incorporation of VBS functional monomer can provideπ-πinteractions,hydrophilic interactions,and ion-exchange in-teractions.Hence,the prepared poly(VBS-co-TAT-co-AHM)monolith can achieve efficient separation of thiourea compounds,benzene series,phenol compounds,aniline compounds and sulfonamides in RPLC or HILIC separation mode.The largest theoretical plate number for N,N0-dimethylthiourea reached 1.7×10^(5)plates/m.In addition,the poly(VBS-co-TAT-co-AHM)monolithic column showed excellent reproducibility and stability.This novel monolithic column has great application value and potential in capillary electrochromatography(CEC).展开更多
Capillary electrochromatography(CEC)plays a significant role in chiral separation via the double separation principle,partition coefficient difference between the two phases,and electroosmotic flow-driven separation.G...Capillary electrochromatography(CEC)plays a significant role in chiral separation via the double separation principle,partition coefficient difference between the two phases,and electroosmotic flow-driven separation.Given the distinct properties of the inner wall stationary phase(SP),the separation ability of each SP differs from one another.Particularly,it provides large room for promising applications of open tubular capillary electrochromatography(OT-CEC).We divided the OT-CEC SPs developed over the past four years into six types:ionic liquids,nanoparticle materials,microporous materials,biomaterials,non-nanopolymers,and others,to mainly introduce their characteristics in chiral drug separation.There also added a few classic SPs that occurred within ten years as supplements to enrich the features of each SP.Additionally,we discuss their applications in metabolomics,food,cosmetics,environment,and biology as analytes in addition to chiral drugs.OT-CEC plays an increasingly significant role in chiral separation and may promote the development of capillary electrophoresis(CE)combined with other instruments in recent years,such as CE with mass spectrometry(CE/MS)and CE with ultraviolet light detector(CE/UV).展开更多
A novel gradient pressurized capillary electrochromatography (pCEC) instrument was developed to separate peptides. Two gradient elution modes, hydrophobic and hydrophilic interaction mode in pCEC, were performed on t...A novel gradient pressurized capillary electrochromatography (pCEC) instrument was developed to separate peptides. Two gradient elution modes, hydrophobic and hydrophilic interaction mode in pCEC, were performed on this instrument. Baseline separation of six peptides was obtained on two gradient modes with C18 column and strong cationic exchange column respectively. The effects of mixer volume and total flow rate of pumps on resolution were also discussed.展开更多
Homochiral metal-organic frameworks(MOFs)have attracted considerable attention in many fields of research,such as chiral catalysis and chiral chromatography.However,only few homochiral MOFs can be effectively used in ...Homochiral metal-organic frameworks(MOFs)have attracted considerable attention in many fields of research,such as chiral catalysis and chiral chromatography.However,only few homochiral MOFs can be effectively used in capillary electrochromatography(CEC)and their performances are far from adequate.In this study,we successfully synthesized achiral nanocrystalline MIL-53.A facile post-synthetic modification strategy was then implemented to functionalize the product,yielding a homochiral MOF:L-His-NH-MIL-53.This MOF was then employed as a chiral coating in open-tubular CEC mode(OT-CEC),and,as such,it exhibited high enantioselectivities for several racemic drugs.The homochiral MOF and the fabricated capillary coating were systematically characterized using transmission electron microscopy,scanning electron microscopy(with energy-dispersive X-ray spectrometry),Fourier-transform infrared spectroscopy,X-ray diffractometry,thermogravimetric analysis,circular dichroism spectroscopy,Brunauer-Emmett-Teller surface area measurements,and X-ray photoelectron spectroscopy.This study is expected to provide a new strategy for the design and establishment of MOF-based chiral OT-CEC systems.展开更多
Covalent organic frameworks(COFs)are a novel type of crystalline porous organic polymer materials recently developed.It has several advantages in chromatographic separation field,such as high thermal stability,porosit...Covalent organic frameworks(COFs)are a novel type of crystalline porous organic polymer materials recently developed.It has several advantages in chromatographic separation field,such as high thermal stability,porosity,structural regularity,and large specific surface area.Here,a novel spherical COF 1,3,5-tris(4-aminophenyl)benzene(TAPB)and 2,5-bis(2-propyn-1-yloxy)-1,4-benzenedicarboxaldehyde(BPTA)was developed as an electrochromatographic stationary phase for capillary electrochromatography separation.The COF TAPB-BPTA modified capillary column was fabricated via a facile in situ growth method at room temperature.The characterization results of scanning electron microscopy(SEM),Fourier transform infrared(FT-IR)spectroscopy,and X-ray diffraction(XRD)confirmed that COF TAPB-BPTA were successfully modified onto the capillary inner surface.The electrochromatography separation performance of the COF TAPB-BPTA modified capillary was investigated.The prepared column demonstrated outstanding separation performance toward alkylbenzenes,phenols,and chlorobenzenes compounds.Furthermore,the baseline separations of non-steroidal anti-inflammatory drugs(NSAIDs)and parabens with good efficiency and high resolution were achieved.Also,the prepared column possessed satisfactory precision of the intra-day runs(n=5),inter-day runs(n=3),and parallel columns(n=3),and the relative standard deviations(RSDs)of the retention times of tested alkylbenzenes were all less than 2.58%.Thus,this new COF-based stationary phase shows tremendous application potential in chromatographic separation field.展开更多
Capillary electrochromatography (CEC) is a hybrid technique that couples the good selectivity of high-performance liquid chromatography (HPLC) and the high separation efficiency of capillary electrophoresis (CE)...Capillary electrochromatography (CEC) is a hybrid technique that couples the good selectivity of high-performance liquid chromatography (HPLC) and the high separation efficiency of capillary electrophoresis (CE). Both charged and uncharged compounds can be separated effectively using CEC. In some cases, however, the bubbles that generated in the capillary column in pure CEC performed on commercial CE instruments will cause unstable current and even disrupt the separation when the concentration of buffer is very high. By applying pressure on the electrochromatographic separation via a micro-HPLC pump, pressurized capillary electrochromatography ( pCEC ) combines two driving factors of the electroosmotic flow (EOF) and the pressure flow, thereby increasing the speed and the selectivity of separation and suppressing the bubble formation. Moreover,展开更多
The preparation of capillary electrochromatography column for chiral separation with β-cyclodextrin derivatized Pancreatin was imvestigated, which had three steps, synthesis of β-cyclodextrin derivated pancreatin, t...The preparation of capillary electrochromatography column for chiral separation with β-cyclodextrin derivatized Pancreatin was imvestigated, which had three steps, synthesis of β-cyclodextrin derivated pancreatin, the modification of the capillary internal surface and the covalent binding of β-cyclodextrin derivated pancreatin on the capillary internal wall. β-cyclodextrin derivated pancreatin was synthesized using β-cyclodextrin and protein in the presence of ethylene glycol diglycidyl ether (EGDE) in boric acid buffer at pH = 8.7. Amino group was coated on the internal surface of the silica capillary by sot-gel technology using triethoxylmethylsiloxane and ( 3-aminopropyl ) trimethoxysiloxane. Covalent binding of β-cyclodextrin derivated pancreatin was performed by glataraldehyde. Chlorpheniramine, phenylalanine and troopine were separated baseline by β-cyclodetrin derivated pancreatin in capillary electrochromatography.展开更多
Synthesis and properties of β-cyclodextrin derivatized ovalbumin used as chiral selector were investigated, β-cyclodextrin derivatized ovalbumin was synthesized using β-cyclodextrin and ovalbumin in the presence of...Synthesis and properties of β-cyclodextrin derivatized ovalbumin used as chiral selector were investigated, β-cyclodextrin derivatized ovalbumin was synthesized using β-cyclodextrin and ovalbumin in the presence of ethylene glycol diglycidyl ether in boric acid buffer at pH value 8.7 at 37℃. Amino group was coated on the internal surface of the silica capillary by sol-gel technology with triethoxylmethylsiloxane and (3-aminopropyl)trimethoxysiloxane. Covalent binding of g-cyclodextrin derivatized ovalbumin was performed by glutaraldehyde. Enantiomers of chlorpheniramine, phenylalanine and atropine were separated by pressure capillary electrochromatography column coated with β-cyclodextrin derivatized ovalbumin.展开更多
Molecular imprinting of theophylline in poly (methacrylic acid- ethylene dimethacrylate) as CEC stationary phases was synthesized by an in situ photo-initiated polymerization reaction. The effect of electrolyte pH on ...Molecular imprinting of theophylline in poly (methacrylic acid- ethylene dimethacrylate) as CEC stationary phases was synthesized by an in situ photo-initiated polymerization reaction. The effect of electrolyte pH on xanthine derivatives and the stability of MIP column performance were investigated. the relative standard deviation (D RS) of migration time of five consecutive runs on MIP column was in the range of 2.2%–3.1%. The reproducibility of migration time column to column of M(A) was in the range of 3.8%–4.9%. The highest column efficiency was more than 140 000 plates per meter. The MIP capillaries had showed better selective for theophylline, which comparing with the reference column. The urine sample was separated by spiked 5×10?4 mol·L?1 theophylline. Key words capillary electrochromatography - molecular imprinting polymers - theophylline CLC number O 657.8 Foundation item: Supported by the National Nature Science Foundation of China (20375028) and the Research Fund for the National High Technology Development “863” of China (2002AA2Z2004)Biography: Cai Ling-shuang (1968-), female, Associate professor, Ph. D, research direction: separation science.展开更多
A novel pressurized capillary electrochromatography (PCEC) was developed to separate basic drugs on strong cation exchange (SCX) column. The separation result by using PCEC was better than that by using micro-HPLC. Th...A novel pressurized capillary electrochromatography (PCEC) was developed to separate basic drugs on strong cation exchange (SCX) column. The separation result by using PCEC was better than that by using micro-HPLC. The effects of electrical field and pressure on plate height and resolution were investigated. Influences of organic modifier, ionic strength and pH value of buffer on retention behavior were evaluated, and the separation mechanism was also discussed.展开更多
A vanillin imprinted capillary monolithic column was synthesized by in situ polymerization reaction using ethylene-glycol dimethacrylate as cross-linking monomer and methacrylic acid as functional monomer. Under the o...A vanillin imprinted capillary monolithic column was synthesized by in situ polymerization reaction using ethylene-glycol dimethacrylate as cross-linking monomer and methacrylic acid as functional monomer. Under the optimum conditions of capillary electrochromatography, this molecularly imprinted polymer (MIP)-based column showed high selectivity and could recognize not only template molecule vanillin but also positional isomer o-vanillin from their structural analogues.展开更多
Chiral metal-organic frameworks(CMOFs)with enantiomeric subunits have been employed in chiral chemistry.In this study,a CMOF formed from 6-methoxyl-(8S,9R)-cinchonan-9-ol-3-carboxylic acid(HQA)and ZnCl_(2),{(HQA)(ZnCl...Chiral metal-organic frameworks(CMOFs)with enantiomeric subunits have been employed in chiral chemistry.In this study,a CMOF formed from 6-methoxyl-(8S,9R)-cinchonan-9-ol-3-carboxylic acid(HQA)and ZnCl_(2),{(HQA)(ZnCl_(2))(2.5H_(2)O)}n,was constructed as a chiral stationary phase(CSP)via an in situ fabrication approach and used for chiral amino acid and drug analyses for the first time.The{(HQA)(ZnCl_(2))(2.5H_(2)O)}n nanocrystal and the corresponding chiral stationary phase were systematically characterised using a series of analytical techniques including scanning electron microscopy,X-ray diffraction,Fourier transform infrared spectroscopy,circular dichroism,X-ray photoelectron spectroscopy,thermogravimetric analysis,and Brunauer-Emmett-Teller surface area measurements.In opentubular capillary electrochromatography(CEC),the novel chiral column exhibited strong and broad enantioselectivity toward a variety of chiral analytes,including 19 racemic dansyl amino acids and several model chiral drugs(both acidic and basic).The chiral CEC conditions were optimised,and the enantioseparation mechanisms are discussed.This study not only introduces a new high-efficiency member of the MOF-type CSP family but also demonstrates the potential of improving the enantioselectivities of traditional chiral recognition reagents by fully using the inherent characteristics of porous organic frameworks.展开更多
A new method to separate diazepam, nitrazepam, estazolam, alprazolam was established on both C18 and C8 CEC columns. The influence of separation voltage, Tris concentration, column temperature and the percentage of ac...A new method to separate diazepam, nitrazepam, estazolam, alprazolam was established on both C18 and C8 CEC columns. The influence of separation voltage, Tris concentration, column temperature and the percentage of acetonitrile on the resolution and retention behavior of four benzodiazepines was investigated. The results showed that the percentage of acetonitrile had the largest effect on the resolution and retention behavior of the four benzodiazepines. Other separation conditions had also effects on the resolution and retention behavior, but smaller than the concentration of acetonitrile. Optimum separation conditions were obtained to separate four benzodiazepines on C18 and C8 CEC columns.展开更多
Covalent organic frameworks(COFs)have been increasingly used in capillary electrochromatography due to their excellent characteristics.In this work,hydrazine-linked TFPB-DHzDS(TFPB:1,3,5-tris(4-formylphenyl)benzene;DH...Covalent organic frameworks(COFs)have been increasingly used in capillary electrochromatography due to their excellent characteristics.In this work,hydrazine-linked TFPB-DHzDS(TFPB:1,3,5-tris(4-formylphenyl)benzene;DHzDS:2,5-bis(3-(ethylthio)propoxy)terephthalohydrazide)was first synthesized by a simpler and easier method at room temperature and introduced into capillary electrochromatography as coating material.The TFPB-DHzDS coated capillaries were prepared by an in-situ growth process at room temperature.After optimizing the coating concentration and experimental conditions of capillary electrochromatography,baseline separation of two groups of polycyclic aromatic hydrocarbons was achieved based on the TFPB-DHzDS coated capillary.And the established method was used successfully to determine PAHs in natural water and soil samples.The spiked recoveries of polycyclic aromatic hydrocarbons in these samples ranged from 90.01%to 111.0%,indicating that the method is reliable and could detect polycyclic aromatic hydrocarbons in natural samples.Finally,molecular simulation was applied to study and visualize the interaction between the analytes and coating COF materials to investigate the molecular level separation mechanism further.展开更多
基金the National Natural Science Foundation of China(Grant Nos.:82273885,82073808 and 81872828).
文摘Here,a styrene-based polymer monolithic column poly(VBS-co-TAT-co-AHM)with reversed-phase/hydrophilic interaction liquid chromatography(RPLC/HILIC)bifunctional separation mode was success-fully prepared for capillary electrochromatography by the in situ polymerization of sodium p-styrene sulfonate(VBS)with cross-linkers 3-(acryloyloxy)-2-hydroxypropyl methacrylate(AHM)and 1,3,5-triacryloylhexahydro-1,3,5-triazine(TAT).The preparation conditions of the monolith were optimized.The morphology and formation of the poly(VBS-co-TAT-co-AHM)monolith were confirmed by scanning electron microscopy(SEM)and Fourier transform infrared spectroscopy(FT-IR).The separation perfor-mances of the monolith were evaluated systematically.It should be noted that the incorporation of VBS functional monomer can provideπ-πinteractions,hydrophilic interactions,and ion-exchange in-teractions.Hence,the prepared poly(VBS-co-TAT-co-AHM)monolith can achieve efficient separation of thiourea compounds,benzene series,phenol compounds,aniline compounds and sulfonamides in RPLC or HILIC separation mode.The largest theoretical plate number for N,N0-dimethylthiourea reached 1.7×10^(5)plates/m.In addition,the poly(VBS-co-TAT-co-AHM)monolithic column showed excellent reproducibility and stability.This novel monolithic column has great application value and potential in capillary electrochromatography(CEC).
基金This study was funded by the Project of National Natural Science Foundation of China(Grant No.:82003705)the Shanghai Science and Technology Innovation Foundation(Grant Nos.:23010500200 and 23ZR1422700).
文摘Capillary electrochromatography(CEC)plays a significant role in chiral separation via the double separation principle,partition coefficient difference between the two phases,and electroosmotic flow-driven separation.Given the distinct properties of the inner wall stationary phase(SP),the separation ability of each SP differs from one another.Particularly,it provides large room for promising applications of open tubular capillary electrochromatography(OT-CEC).We divided the OT-CEC SPs developed over the past four years into six types:ionic liquids,nanoparticle materials,microporous materials,biomaterials,non-nanopolymers,and others,to mainly introduce their characteristics in chiral drug separation.There also added a few classic SPs that occurred within ten years as supplements to enrich the features of each SP.Additionally,we discuss their applications in metabolomics,food,cosmetics,environment,and biology as analytes in addition to chiral drugs.OT-CEC plays an increasingly significant role in chiral separation and may promote the development of capillary electrophoresis(CE)combined with other instruments in recent years,such as CE with mass spectrometry(CE/MS)and CE with ultraviolet light detector(CE/UV).
基金The study is supported by NNSFC,grant No.20175010.
文摘A novel gradient pressurized capillary electrochromatography (pCEC) instrument was developed to separate peptides. Two gradient elution modes, hydrophobic and hydrophilic interaction mode in pCEC, were performed on this instrument. Baseline separation of six peptides was obtained on two gradient modes with C18 column and strong cationic exchange column respectively. The effects of mixer volume and total flow rate of pumps on resolution were also discussed.
基金funded by the National Natural Science Foundation of China(Grant No.:82003705).
文摘Homochiral metal-organic frameworks(MOFs)have attracted considerable attention in many fields of research,such as chiral catalysis and chiral chromatography.However,only few homochiral MOFs can be effectively used in capillary electrochromatography(CEC)and their performances are far from adequate.In this study,we successfully synthesized achiral nanocrystalline MIL-53.A facile post-synthetic modification strategy was then implemented to functionalize the product,yielding a homochiral MOF:L-His-NH-MIL-53.This MOF was then employed as a chiral coating in open-tubular CEC mode(OT-CEC),and,as such,it exhibited high enantioselectivities for several racemic drugs.The homochiral MOF and the fabricated capillary coating were systematically characterized using transmission electron microscopy,scanning electron microscopy(with energy-dispersive X-ray spectrometry),Fourier-transform infrared spectroscopy,X-ray diffractometry,thermogravimetric analysis,circular dichroism spectroscopy,Brunauer-Emmett-Teller surface area measurements,and X-ray photoelectron spectroscopy.This study is expected to provide a new strategy for the design and establishment of MOF-based chiral OT-CEC systems.
基金supported by the National Natural Science Foundation of China(Grant Nos.:82073808,81872828,and 81573384).
文摘Covalent organic frameworks(COFs)are a novel type of crystalline porous organic polymer materials recently developed.It has several advantages in chromatographic separation field,such as high thermal stability,porosity,structural regularity,and large specific surface area.Here,a novel spherical COF 1,3,5-tris(4-aminophenyl)benzene(TAPB)and 2,5-bis(2-propyn-1-yloxy)-1,4-benzenedicarboxaldehyde(BPTA)was developed as an electrochromatographic stationary phase for capillary electrochromatography separation.The COF TAPB-BPTA modified capillary column was fabricated via a facile in situ growth method at room temperature.The characterization results of scanning electron microscopy(SEM),Fourier transform infrared(FT-IR)spectroscopy,and X-ray diffraction(XRD)confirmed that COF TAPB-BPTA were successfully modified onto the capillary inner surface.The electrochromatography separation performance of the COF TAPB-BPTA modified capillary was investigated.The prepared column demonstrated outstanding separation performance toward alkylbenzenes,phenols,and chlorobenzenes compounds.Furthermore,the baseline separations of non-steroidal anti-inflammatory drugs(NSAIDs)and parabens with good efficiency and high resolution were achieved.Also,the prepared column possessed satisfactory precision of the intra-day runs(n=5),inter-day runs(n=3),and parallel columns(n=3),and the relative standard deviations(RSDs)of the retention times of tested alkylbenzenes were all less than 2.58%.Thus,this new COF-based stationary phase shows tremendous application potential in chromatographic separation field.
基金Supported by the National Natural Science Foundation of China(Nos 20305004 and 20575012), Program for NewCentury Ex-cellent Talents in University of China(No NCET-04-0612), Specialized Research Fund for the Doctoral Program of Higher Education(No 20050386008), and the Science Foundation of Fujian Province(Nos 2005Y015 and D0510006)
文摘Capillary electrochromatography (CEC) is a hybrid technique that couples the good selectivity of high-performance liquid chromatography (HPLC) and the high separation efficiency of capillary electrophoresis (CE). Both charged and uncharged compounds can be separated effectively using CEC. In some cases, however, the bubbles that generated in the capillary column in pure CEC performed on commercial CE instruments will cause unstable current and even disrupt the separation when the concentration of buffer is very high. By applying pressure on the electrochromatographic separation via a micro-HPLC pump, pressurized capillary electrochromatography ( pCEC ) combines two driving factors of the electroosmotic flow (EOF) and the pressure flow, thereby increasing the speed and the selectivity of separation and suppressing the bubble formation. Moreover,
文摘The preparation of capillary electrochromatography column for chiral separation with β-cyclodextrin derivatized Pancreatin was imvestigated, which had three steps, synthesis of β-cyclodextrin derivated pancreatin, the modification of the capillary internal surface and the covalent binding of β-cyclodextrin derivated pancreatin on the capillary internal wall. β-cyclodextrin derivated pancreatin was synthesized using β-cyclodextrin and protein in the presence of ethylene glycol diglycidyl ether (EGDE) in boric acid buffer at pH = 8.7. Amino group was coated on the internal surface of the silica capillary by sot-gel technology using triethoxylmethylsiloxane and ( 3-aminopropyl ) trimethoxysiloxane. Covalent binding of β-cyclodextrin derivated pancreatin was performed by glataraldehyde. Chlorpheniramine, phenylalanine and troopine were separated baseline by β-cyclodetrin derivated pancreatin in capillary electrochromatography.
基金the National Natural Science Foundation of China(20275004)
文摘Synthesis and properties of β-cyclodextrin derivatized ovalbumin used as chiral selector were investigated, β-cyclodextrin derivatized ovalbumin was synthesized using β-cyclodextrin and ovalbumin in the presence of ethylene glycol diglycidyl ether in boric acid buffer at pH value 8.7 at 37℃. Amino group was coated on the internal surface of the silica capillary by sol-gel technology with triethoxylmethylsiloxane and (3-aminopropyl)trimethoxysiloxane. Covalent binding of g-cyclodextrin derivatized ovalbumin was performed by glutaraldehyde. Enantiomers of chlorpheniramine, phenylalanine and atropine were separated by pressure capillary electrochromatography column coated with β-cyclodextrin derivatized ovalbumin.
文摘Molecular imprinting of theophylline in poly (methacrylic acid- ethylene dimethacrylate) as CEC stationary phases was synthesized by an in situ photo-initiated polymerization reaction. The effect of electrolyte pH on xanthine derivatives and the stability of MIP column performance were investigated. the relative standard deviation (D RS) of migration time of five consecutive runs on MIP column was in the range of 2.2%–3.1%. The reproducibility of migration time column to column of M(A) was in the range of 3.8%–4.9%. The highest column efficiency was more than 140 000 plates per meter. The MIP capillaries had showed better selective for theophylline, which comparing with the reference column. The urine sample was separated by spiked 5×10?4 mol·L?1 theophylline. Key words capillary electrochromatography - molecular imprinting polymers - theophylline CLC number O 657.8 Foundation item: Supported by the National Nature Science Foundation of China (20375028) and the Research Fund for the National High Technology Development “863” of China (2002AA2Z2004)Biography: Cai Ling-shuang (1968-), female, Associate professor, Ph. D, research direction: separation science.
基金theNationalNaturalScienceFoundationofChina (No .2 0 175 0 10 )the 14thNationalKeyLaboratoryOpeningFounda ionofChina (No .2 0 12 0 3 )
文摘A novel pressurized capillary electrochromatography (PCEC) was developed to separate basic drugs on strong cation exchange (SCX) column. The separation result by using PCEC was better than that by using micro-HPLC. The effects of electrical field and pressure on plate height and resolution were investigated. Influences of organic modifier, ionic strength and pH value of buffer on retention behavior were evaluated, and the separation mechanism was also discussed.
基金Project supported by the National Natural Science Foundation of China (No. 20175010).
文摘A vanillin imprinted capillary monolithic column was synthesized by in situ polymerization reaction using ethylene-glycol dimethacrylate as cross-linking monomer and methacrylic acid as functional monomer. Under the optimum conditions of capillary electrochromatography, this molecularly imprinted polymer (MIP)-based column showed high selectivity and could recognize not only template molecule vanillin but also positional isomer o-vanillin from their structural analogues.
基金This study was funded by the National Natural Science Foundation of China(Grant No.:82003705)the Shanghai Science and Technology Innovation Foundation(Grant Nos.:23010500200 and 23ZR1422700).
文摘Chiral metal-organic frameworks(CMOFs)with enantiomeric subunits have been employed in chiral chemistry.In this study,a CMOF formed from 6-methoxyl-(8S,9R)-cinchonan-9-ol-3-carboxylic acid(HQA)and ZnCl_(2),{(HQA)(ZnCl_(2))(2.5H_(2)O)}n,was constructed as a chiral stationary phase(CSP)via an in situ fabrication approach and used for chiral amino acid and drug analyses for the first time.The{(HQA)(ZnCl_(2))(2.5H_(2)O)}n nanocrystal and the corresponding chiral stationary phase were systematically characterised using a series of analytical techniques including scanning electron microscopy,X-ray diffraction,Fourier transform infrared spectroscopy,circular dichroism,X-ray photoelectron spectroscopy,thermogravimetric analysis,and Brunauer-Emmett-Teller surface area measurements.In opentubular capillary electrochromatography(CEC),the novel chiral column exhibited strong and broad enantioselectivity toward a variety of chiral analytes,including 19 racemic dansyl amino acids and several model chiral drugs(both acidic and basic).The chiral CEC conditions were optimised,and the enantioseparation mechanisms are discussed.This study not only introduces a new high-efficiency member of the MOF-type CSP family but also demonstrates the potential of improving the enantioselectivities of traditional chiral recognition reagents by fully using the inherent characteristics of porous organic frameworks.
文摘A new method to separate diazepam, nitrazepam, estazolam, alprazolam was established on both C18 and C8 CEC columns. The influence of separation voltage, Tris concentration, column temperature and the percentage of acetonitrile on the resolution and retention behavior of four benzodiazepines was investigated. The results showed that the percentage of acetonitrile had the largest effect on the resolution and retention behavior of the four benzodiazepines. Other separation conditions had also effects on the resolution and retention behavior, but smaller than the concentration of acetonitrile. Optimum separation conditions were obtained to separate four benzodiazepines on C18 and C8 CEC columns.
基金the National Natural Science Foundation of China(Grant Nos.21705064,21675068)for financial support.
文摘Covalent organic frameworks(COFs)have been increasingly used in capillary electrochromatography due to their excellent characteristics.In this work,hydrazine-linked TFPB-DHzDS(TFPB:1,3,5-tris(4-formylphenyl)benzene;DHzDS:2,5-bis(3-(ethylthio)propoxy)terephthalohydrazide)was first synthesized by a simpler and easier method at room temperature and introduced into capillary electrochromatography as coating material.The TFPB-DHzDS coated capillaries were prepared by an in-situ growth process at room temperature.After optimizing the coating concentration and experimental conditions of capillary electrochromatography,baseline separation of two groups of polycyclic aromatic hydrocarbons was achieved based on the TFPB-DHzDS coated capillary.And the established method was used successfully to determine PAHs in natural water and soil samples.The spiked recoveries of polycyclic aromatic hydrocarbons in these samples ranged from 90.01%to 111.0%,indicating that the method is reliable and could detect polycyclic aromatic hydrocarbons in natural samples.Finally,molecular simulation was applied to study and visualize the interaction between the analytes and coating COF materials to investigate the molecular level separation mechanism further.