A sensitive and simple micellar electrokinetic chromatography (MEKC) method was developed for the determination of antiepileptic drug, carbamazepine (CBZ), using sweeping on-line concentration method with photodio...A sensitive and simple micellar electrokinetic chromatography (MEKC) method was developed for the determination of antiepileptic drug, carbamazepine (CBZ), using sweeping on-line concentration method with photodiode array detection. Under the optimal conditions, the calibration curve was linear over a range of 0.5-40μg·mL^-1 for CBZ with a correlation coefficient of 0.998. The detection limit (S/N = 3:1) of CBZ was 0.10 μg·mL^-1. The sweeping-MEKC method has been successfully applied to the analysis of CBZ in human serum.展开更多
文摘A sensitive and simple micellar electrokinetic chromatography (MEKC) method was developed for the determination of antiepileptic drug, carbamazepine (CBZ), using sweeping on-line concentration method with photodiode array detection. Under the optimal conditions, the calibration curve was linear over a range of 0.5-40μg·mL^-1 for CBZ with a correlation coefficient of 0.998. The detection limit (S/N = 3:1) of CBZ was 0.10 μg·mL^-1. The sweeping-MEKC method has been successfully applied to the analysis of CBZ in human serum.