An experimental investigation into the thermal conductivity of CF-SiC two-phase composite asphalt concrete is presented.The main objective of this study was to verify the possibility of using SiC powder instead of min...An experimental investigation into the thermal conductivity of CF-SiC two-phase composite asphalt concrete is presented.The main objective of this study was to verify the possibility of using SiC powder instead of mineral powder as the thermal conductive filler to prepare a new type of asphalt concrete and improve the efficiency of electrothermal snow and ice melting systems accordingly.The thermal conductivity of asphalt concrete prepared with different thermally conductive fillers was tested by a transient plane source method,and the related performances were measured.Then the temperature rise rate and surface temperature were studied through field heating tests.Finally,the actual ice melting efficiency of the thermally conductive asphalt concrete was evaluated using an effective electrothermal system.As shown by the experimental results,the composite made of SiC powder and carbon fiber has a high thermal conductivity.When SiC replaces mineral powder,the thermal conductivity of the asphalt mixture increases first and then decreases with the increase of carbon fiber content.In the present study,in particular,the thermal conductivity attained a peak when the carbon fiber content was 0.2%of the aggregate mass.展开更多
Eight high strength concrete (HSC) prisms strengthened with continuous carbon fiber sheet(CFS)were tested.As a result of the confinement provided by CFS,the concrete would fail at a greater strain than the unconfined ...Eight high strength concrete (HSC) prisms strengthened with continuous carbon fiber sheet(CFS)were tested.As a result of the confinement provided by CFS,the concrete would fail at a greater strain than the unconfined and then a significant increase in ductility can be achieved.The lateral pressure exerted by CFS would increase the compressive strength of the concrete,resulting in higher load bearing capacity.This paper proposes the stress strain curve of this kind of hybrid specimen,which agrees well with the test results.Based on the stress strain relationship and the assumptions proposed in this paper,a computer program was developed to analyze HSC columns,confined by CFS,which were subjected to axial compression and biaxial bending.The results shown in this paper indicate that the ductility of HSC column is significantly improved and the strength is also increased by some degree.展开更多
The self-monitoring application of asphalt concrete containing graphite and carbon fibers using indirect tensile test and wheel rolling test were introduced. The experiment results indicate that this kind of pitch-bas...The self-monitoring application of asphalt concrete containing graphite and carbon fibers using indirect tensile test and wheel rolling test were introduced. The experiment results indicate that this kind of pitch-based composite is effective for strain/stress self-monitoring. In the indirect tensile test, for a completely conductive asphalt concrete specimen, the piezoresistivity was very weak and slightly positive, which meant the resistivity increase with the increment of tensile strain at all stress/strain amplitudes, with the gage factor as high as 6. The strain self-sensing ability was superior in the case of higher graphite content. However, when the conductive concrete was embedded into common asphalt concrete specimen as a partial structure function, the piezoresistivity was positive at all stress/strain amplitudes and with the gage factor of 13, which was much higher than that of completely conductive specimen. Thus, the strain self-sensing ability was superior when conductive asphalt concrete was taken in as a partial structure function. In the wheel-rolling test, the piezoresistivity was highly positive. At any stress amplitude, the piezoresistivity was strong, with the gage factor as high as 100, which was higher for a stress amplitude of 0.7 MPa than that of 0.5 MPa.展开更多
This paper discussed two methods to enhance the electrical conductivity of the carbon fiber(CF) electrically conductive concrete. The increase in the content of stone and the amount of water used to dissolve the met...This paper discussed two methods to enhance the electrical conductivity of the carbon fiber(CF) electrically conductive concrete. The increase in the content of stone and the amount of water used to dissolve the methylcellulose and marinate the carbon fibers can decrease the electrical resistivity of the electrically conductive concrete effectively. Based on these two methods, the minimum CF content of the CF electrically conductive concrete for deicing or snow-melting application and the optimal ratio of the amount of water to dissolve the methylcellulose and marinate the carbon fibers were obtained.展开更多
Carbon fiber reinforced concrete (CFRC) is a kind of good electrothermal material. When connected to an external power supply, stable and uniform heat suitable for deicing application is generated in the CFRC slab. El...Carbon fiber reinforced concrete (CFRC) is a kind of good electrothermal material. When connected to an external power supply, stable and uniform heat suitable for deicing application is generated in the CFRC slab. Electric heating and deicing experiments of carbon fiber reinforced concrete slab were carried out in laboratory, and the effect of the temperature and thickness of ice, the thermal conductivity of CFRC, and power output on deicing performance and energy consumption were investigated. The experimental results indicate that it is an effective method to utilize the thermal energy produced by CFRC slab to deice. The time to melt the ice completely decreases with increasing power output and ice temperature, and increases with increasing thickness of the ice. The energy consumption to melt 2 mm thickness of ice varies approximately linearly from 0.556 to 0.846 kW·h/m2 as the initial temperature ranges from -3℃ to - 18℃. CFRC with good thermal conduction can reduce temperature difference in CFRC slab effectively.展开更多
The relationship between the electrical resistivity of carbon fiber reinforced concrete(CFRC) containing different carbon fiber contents and temperature was studied.it is found that carbon fiber contents influence gre...The relationship between the electrical resistivity of carbon fiber reinforced concrete(CFRC) containing different carbon fiber contents and temperature was studied.it is found that carbon fiber contents influence greatly on the temperature sensibility of CFRC road material.Only with a certain amount of carbon fiber can CFRC show a sensitive and stable temperature sensibility.展开更多
The use of carbon-fiber heating cables(CFHC)to achieve effective melting of snow and ice deposited on roads is a method used worldwide.In this study,tensile and compressive tests have been conducted to analyze the mech...The use of carbon-fiber heating cables(CFHC)to achieve effective melting of snow and ice deposited on roads is a method used worldwide.In this study,tensile and compressive tests have been conducted to analyze the mechan-ical properties of the CFHC and assess whether the maximum tensile and compressive strengths can meet the pavement design specifications.In order to study the aging produced by multiple cycles of heating and cooling,in particular,the CFHC was repeatedly heated in a cold chamber with an ambient temperature ranging between-20℃ and+40℃.Moreover,to evaluate how the strength of the pavement is affected by its presence,the CFHC was embedded at different depths and concrete blocks with different curing ages were subjected to relevant com-pression and splitting tensile tests.Numerical simulations based on the ANSYS software have also been performed and compared with the outcomes of the static loading tests.The results show that the CFHC embedded in the concrete does not affect the compressive splitting tensile strengths of the pavement.Overall,the CFHC meets the conditions required for continued use in road ice melting applications.展开更多
Twenty-one square concrete columns were constructed and tested. The testing results indicate that bonded carbon fiber reinforced plastics(CFRP) sheets can be used to increase the strength and improve the serviceabilit...Twenty-one square concrete columns were constructed and tested. The testing results indicate that bonded carbon fiber reinforced plastics(CFRP) sheets can be used to increase the strength and improve the serviceability of damaged concrete columns at low temperatures. The failure of the specimens,in most cases,takes place within the middle half of the columns. And the failure of strengthened columns is sudden and explosive. The CFRP sheets increase both the axial load capacity and the ultimate concrete compressive strain of the columns. The ultimate loads of strengthened columns at-10,0 and 10 ℃ increase averagely by 9.09%,6.63% and 17.83%,respectively,as compared with those of the control specimens. The axial compressive strength of strengthened columns is related to the curing temperatures. The improvement of axial compressive strength decreases with reducing temperature,and when the temperature drops to a certain value,the improvement increases with falling temperature.展开更多
According to the phenomenon that the physical properties have,a great effect on the electric capability of carbon fiber reinforced concrete, the author researched the relationship between DC resistance of carbon fiber...According to the phenomenon that the physical properties have,a great effect on the electric capability of carbon fiber reinforced concrete, the author researched the relationship between DC resistance of carbon fiber reinforced concrete and curing age using the two-probe method. Then the effect of insulative area, location and quantity on DC resistance of carbon fiber reinforced concrete was investigated at different curing age with analysis of hydration. The results suggest that DC resistance increases greatly with its curing age, which illustrates the relationship like Gaussian curve. In every curing ages the electric capability of carbon fiber reinforced concrete weakenes with the increase of insulative area. In same curing ages, section and insulative area, the more the quantity of insulation, the stronger the conductibility. The insulative location in optimal position can only result in optimal conductibility.展开更多
Concrete containing short carbon-coated-nylon fibers (0.4-2.0 vol. pct) exhibited quasi-ductile response by developing a large damage zone prior to fracture localization. In the damage zone, the material was microcrac...Concrete containing short carbon-coated-nylon fibers (0.4-2.0 vol. pct) exhibited quasi-ductile response by developing a large damage zone prior to fracture localization. In the damage zone, the material was microcracked but continued to local strain-harden. The carbon-coated-nylon-fiber-reinforced concrete composites (NFRC) were found to be an intrinsically smart concrete that could sense elastic and inelastic deformation, as well as fracture. The fibers served to bridge the cracks and the carbon coating gave the conduction path. The signal provided came from the change in electrical resistance, which was reversible for elastic deformation and irreversible for inelastic deformation and fracture. The resistance decrease was due to the reduction of surface touch resistance between fiber and matrix and the crack closure. The resistance irreversible increase resulted from the crack opening and breakage of the carbon coating on nylon fiber.展开更多
Extensive research has shown that externally bonded carbon fiber reinforced polymer (CFRP) laminates are particularly suitable for improving the fatigue behavior of reinforced concrete (RC) beams. This paper prese...Extensive research has shown that externally bonded carbon fiber reinforced polymer (CFRP) laminates are particularly suitable for improving the fatigue behavior of reinforced concrete (RC) beams. This paper presents the research on flexural ngidity evolvement laws by testing 14 simple-supported RC beams strengthened with carbon fiber laminates (CFL) under cyclic load, and 2 under monotone load as a reference. The cyclic load tests revealed the peak load applied onto the surface of a supported RC beam strengthened with CFL is linear to the logarithm of its fatigue life, and the flexural rigidity evolvement undergoes three distinct phases: a rapid decrease from the start to about 5% of the fatigue life; an even development from .5% to about 99% of the fatigue life; and a succedent rapid decrease to failure. When the ratio of fatigue "cycles to the fatigue life is within 0.0.5 to 0.99, the flexural rigidity varies linearly with the ratio. The peak load does not affect the flexural rigidity evolvement if it is not high enough to make the main reinforcements yield. The dependences of the flexural rigidity of specimens formed in the same group upon their fatigue cycles normalized by fatigue life are almost coincident. This implies the flexural rigidity may be a material parameter independent of the stress level. These relationships of flexural rigidity to fatigue cycles, and fatigue life may be able to provide some hints for fatigue design and fatigue life evaluation of RC member strengthened with CFL; nevertheless the findings still need verifying by more experiments.展开更多
This paper presents the results of an experimental investigation on the response of pre-damaged reinforced concrete (RC) beam strengthened in shear using applied-epoxy unidirectional carbon fiber reinforced polymer ...This paper presents the results of an experimental investigation on the response of pre-damaged reinforced concrete (RC) beam strengthened in shear using applied-epoxy unidirectional carbon fiber reinforced polymer (CFRP) sheet. The reasearch included four test rectangular simply supported RC beams in shear capacity. One is the control beam, two RC beams are damaged to a predetermined degree from ultimate shear capacity of the control beam, and the last beam is left without pre-damaged and then strengthened with using externally bonded carbon fiber reinforced polymer to upgrade their shear capacity. We focused on the damage degree to beams during strengthening, therefore, only the beams with sidebonded CFRPs strips and horizontal anchored strips were used. The results show the feasibility of using CFRPs to restore or increase the load-carrying capacity in the shear of damaged RC beams. The failure mode of all the CFRP-strengthened beams is debonding of CFRP vertical strips. Two prediction available models in AC1-440 and fib European code were compared with the experimental results.展开更多
According to the principle of electrical resistance tomography ( ERT), the resistivity distribution of the carbon fiber reinforced concrete (CFRC) in the sensing field can be measured by injecting exciting current...According to the principle of electrical resistance tomography ( ERT), the resistivity distribution of the carbon fiber reinforced concrete (CFRC) in the sensing field can be measured by injecting exciting current and measuring the voltage on the sensor electrode arrays installed on the surface of the object. Therefore, measurement of the resistivity distribution of CFRC is divided into first measuring the boundary conditions and then inversely computing the resistivity distribution. To reach this goal, an ERT system was constructed, which is composed of a sensor array unit, a data acquisition unit and an image reconstruction unit. Simulations of static ERT was performed on set-ups with many objects spread in a homogeneous background, and a simulation of dynamic ERT was also done on a rectangular board, the resistivity of which was changed within a small domain of it. Then, the resistivity distribution of a CFRC sample with a circlar hole as the target was detected by the ERT system. Simulation and experimental results show that the reconstructed ERT image reflects the resistivity distribution or the resistivity change of CFRC structure well. Especially, a small change in resistivity can be identified from the reconstructed images in the simulation of dynamic ERT images.展开更多
In this paper,the influence of some important parameters affecting the flexural behavior of reinforced concrete beams strengthened with one layer of carbon fiber reinforced polymer(CFRP)laminate has been studied.For t...In this paper,the influence of some important parameters affecting the flexural behavior of reinforced concrete beams strengthened with one layer of carbon fiber reinforced polymer(CFRP)laminate has been studied.For this purpose,six reinforced concrete beams were cast and tested in the laboratory.Based on the obtained data,when CFRP laminate is applied to the tension face,too close to the steel rebar,the flexural strength of the strengthened beam is reduced.In general,the performance of the beam strengthened with one wide CFRP strip is better than that strengthened with two equivalent narrow strips.Ultimate load capacity of each strengthened beam was calculated based on the method given by the ACI 440.2R and compared with the test one.It is concluded that,to avoid the steel rebar-CFRP laminate interaction effect,the CFRP laminate depth-to-the effective depth ratio(df/d)should not be smaller than about 1.17.展开更多
The stress-resistance relationship of carbon fiber cement was studied.Attention has been paid to explore the improvement of the stress-resistance sensitivity under cycled stress restriction.The prismy carbon fiber cem...The stress-resistance relationship of carbon fiber cement was studied.Attention has been paid to explore the improvement of the stress-resistance sensitivity under cycled stress restriction.The prismy carbon fiber cement sensors were pre-fabricated.The factors such as contents of carbon fibers.silica fume,dispersant and the w/c were taken into account.The electrical resistance variations with the dynamic and static loads were simulated using a strain-controlled test machine.The test results show that there is an optimal fiber content,with which the compression-sensitivity achieves a high level.The addition of silica fume can improve the sensitivity.Under the optimal test conditions,the measured resistances can greatly correspond with the changes of the load.展开更多
By heating up the embedded carbon fiber reinforced cement based material (CFRC), the carrying capacity and deformation of concrete member could be adjusted. The relationship between temperature difference and expans...By heating up the embedded carbon fiber reinforced cement based material (CFRC), the carrying capacity and deformation of concrete member could be adjusted. The relationship between temperature difference and expansion strain of CFRC was demonstrated, and the temperature-deformation-load effect of concrete embedded with CFRC was studied. Heating the CFRC up to different temperatures resulted in different degree of inner pre-stress in concrete. Thus, the load capacity of concrete could be regulated owing to counteracting the pre-stress.展开更多
The seepage theory was used to explain the variation between the specific resistance of the carbon fiber reinforced cement concrete and the carbon fiber volume ratio. The electro-dynamic seepage was observed in the ce...The seepage theory was used to explain the variation between the specific resistance of the carbon fiber reinforced cement concrete and the carbon fiber volume ratio. The electro-dynamic seepage was observed in the cement. The longer the carbon fiber is, the smaller the critical volume to produce the electro-dynamic seepage phenomenon will be. However, the forming and stirring process is harder. In general, the average length of carbon fiber is 5 mm. Under the condition of three-point bending load, the specific resistance changes with the loading process, and a good correlation could be obtained according to the load-deflection relationship. The experimental results reveal that the carbon fiber reinforced cement based composites can be used as sensors to self-diagnoses of the damage.展开更多
Due to the inherent property of concrete being very weak in tension, efforts have been made to overcome this deficiency by adding various type of fibers like carbon fiber reinforced polymer (CFRP), glass fiber reinfor...Due to the inherent property of concrete being very weak in tension, efforts have been made to overcome this deficiency by adding various type of fibers like carbon fiber reinforced polymer (CFRP), glass fiber reinforced polymer (GFRP), polypropylene fiber (PPF) and stainlesssteel fiber (SSF) smeared into the concrete mix. The present study involves experimental investigation on the use of GFRP, CFRP and SSF fibers alone or as combination to improve the mechanical properties of concrete. Furthermore, concrete cylinders were cast and tested for compression and tension using 10% fly ash as cement replacement in all specimens. Besides fiber material types, fiber reinforcement ratios of 1% and 1.5% were tested to investigate the mechanical properties of concrete. In all concrete cylinder tests, the fiber reinforcement ratio of 1% had a significant contribution in increasing the tensile strength as oppose to compressive strength. As a result, the tensile and compressive strengths were increased by 26% and 11%, respectively as compared to the control specimen. Increasing the fiber reinforcement ratio from 1% to 1.5%, resulted in diminishing the mechanical properties of concrete. However, reduction in concrete compressive strength was more prominent than the tensile strength. Furthermore, it was observed that, the crack propagation was decreased with the increase of fiber content when compared to the control specimen.展开更多
Concrete, as an essential construction material in the construction industry, is the main component of solid waste. To improve the strength and durability of concrete, some additives can be added into concrete to repl...Concrete, as an essential construction material in the construction industry, is the main component of solid waste. To improve the strength and durability of concrete, some additives can be added into concrete to replace parts of cement. Carbon fiber and silica powder are the most common additives. Under a series of experiments, the effects of temperature, carbon fiber and silica powder on the mechanical properties of concrete were studied under normal circumstances. In this paper, a conclusion on the effects was drawn up mainly through some experimental analyses, so as to discuss the effect laws and provide a reference to manufacture the concrete of high strength and properties.展开更多
基金the support of the Joint Funds of the Natural Science Foundation of Hubei Province(2022CFD130)the Technology Innovation Project of Hubei Province(Key Program,No.2023BEB010)+1 种基金the Key Research and Development Program of Hubei Province(No.2021BGD015)the Knowledge Innovation Project of Wuhan(No.2022010801010259).
文摘An experimental investigation into the thermal conductivity of CF-SiC two-phase composite asphalt concrete is presented.The main objective of this study was to verify the possibility of using SiC powder instead of mineral powder as the thermal conductive filler to prepare a new type of asphalt concrete and improve the efficiency of electrothermal snow and ice melting systems accordingly.The thermal conductivity of asphalt concrete prepared with different thermally conductive fillers was tested by a transient plane source method,and the related performances were measured.Then the temperature rise rate and surface temperature were studied through field heating tests.Finally,the actual ice melting efficiency of the thermally conductive asphalt concrete was evaluated using an effective electrothermal system.As shown by the experimental results,the composite made of SiC powder and carbon fiber has a high thermal conductivity.When SiC replaces mineral powder,the thermal conductivity of the asphalt mixture increases first and then decreases with the increase of carbon fiber content.In the present study,in particular,the thermal conductivity attained a peak when the carbon fiber content was 0.2%of the aggregate mass.
文摘Eight high strength concrete (HSC) prisms strengthened with continuous carbon fiber sheet(CFS)were tested.As a result of the confinement provided by CFS,the concrete would fail at a greater strain than the unconfined and then a significant increase in ductility can be achieved.The lateral pressure exerted by CFS would increase the compressive strength of the concrete,resulting in higher load bearing capacity.This paper proposes the stress strain curve of this kind of hybrid specimen,which agrees well with the test results.Based on the stress strain relationship and the assumptions proposed in this paper,a computer program was developed to analyze HSC columns,confined by CFS,which were subjected to axial compression and biaxial bending.The results shown in this paper indicate that the ductility of HSC column is significantly improved and the strength is also increased by some degree.
基金the Outstanding Youth Foundation of Hubei Province(No.2004ABB019)Program for New Century Excellent Talents in University,China(No.NCET-05-0665)
文摘The self-monitoring application of asphalt concrete containing graphite and carbon fibers using indirect tensile test and wheel rolling test were introduced. The experiment results indicate that this kind of pitch-based composite is effective for strain/stress self-monitoring. In the indirect tensile test, for a completely conductive asphalt concrete specimen, the piezoresistivity was very weak and slightly positive, which meant the resistivity increase with the increment of tensile strain at all stress/strain amplitudes, with the gage factor as high as 6. The strain self-sensing ability was superior in the case of higher graphite content. However, when the conductive concrete was embedded into common asphalt concrete specimen as a partial structure function, the piezoresistivity was positive at all stress/strain amplitudes and with the gage factor of 13, which was much higher than that of completely conductive specimen. Thus, the strain self-sensing ability was superior when conductive asphalt concrete was taken in as a partial structure function. In the wheel-rolling test, the piezoresistivity was highly positive. At any stress amplitude, the piezoresistivity was strong, with the gage factor as high as 100, which was higher for a stress amplitude of 0.7 MPa than that of 0.5 MPa.
基金the National Natural Science Foundation of China (No.50238040)Postdoctor Foundation(No.2005037668)
文摘This paper discussed two methods to enhance the electrical conductivity of the carbon fiber(CF) electrically conductive concrete. The increase in the content of stone and the amount of water used to dissolve the methylcellulose and marinate the carbon fibers can decrease the electrical resistivity of the electrically conductive concrete effectively. Based on these two methods, the minimum CF content of the CF electrically conductive concrete for deicing or snow-melting application and the optimal ratio of the amount of water to dissolve the methylcellulose and marinate the carbon fibers were obtained.
基金This work was supported by the key project of National Natural Science Foundation of China under grant No.50238040.
文摘Carbon fiber reinforced concrete (CFRC) is a kind of good electrothermal material. When connected to an external power supply, stable and uniform heat suitable for deicing application is generated in the CFRC slab. Electric heating and deicing experiments of carbon fiber reinforced concrete slab were carried out in laboratory, and the effect of the temperature and thickness of ice, the thermal conductivity of CFRC, and power output on deicing performance and energy consumption were investigated. The experimental results indicate that it is an effective method to utilize the thermal energy produced by CFRC slab to deice. The time to melt the ice completely decreases with increasing power output and ice temperature, and increases with increasing thickness of the ice. The energy consumption to melt 2 mm thickness of ice varies approximately linearly from 0.556 to 0.846 kW·h/m2 as the initial temperature ranges from -3℃ to - 18℃. CFRC with good thermal conduction can reduce temperature difference in CFRC slab effectively.
文摘The relationship between the electrical resistivity of carbon fiber reinforced concrete(CFRC) containing different carbon fiber contents and temperature was studied.it is found that carbon fiber contents influence greatly on the temperature sensibility of CFRC road material.Only with a certain amount of carbon fiber can CFRC show a sensitive and stable temperature sensibility.
基金The authors have received financial support from the National Natural Science Foundation of China(No.52078194)the Key Research and Development Program of Hubei Province(No.2021BGD015)the Knowledge Innovation Project of Wuhan(No.2022010801010259).
文摘The use of carbon-fiber heating cables(CFHC)to achieve effective melting of snow and ice deposited on roads is a method used worldwide.In this study,tensile and compressive tests have been conducted to analyze the mechan-ical properties of the CFHC and assess whether the maximum tensile and compressive strengths can meet the pavement design specifications.In order to study the aging produced by multiple cycles of heating and cooling,in particular,the CFHC was repeatedly heated in a cold chamber with an ambient temperature ranging between-20℃ and+40℃.Moreover,to evaluate how the strength of the pavement is affected by its presence,the CFHC was embedded at different depths and concrete blocks with different curing ages were subjected to relevant com-pression and splitting tensile tests.Numerical simulations based on the ANSYS software have also been performed and compared with the outcomes of the static loading tests.The results show that the CFHC embedded in the concrete does not affect the compressive splitting tensile strengths of the pavement.Overall,the CFHC meets the conditions required for continued use in road ice melting applications.
基金Project(04043076) supported by the Outstanding Youth Foundation for Scientific and Technological Research of Anhui Province, ChinaProject(2007jq1035) supported by the Scientific Research Projects for Young College Teachers of Anhui Province, China
文摘Twenty-one square concrete columns were constructed and tested. The testing results indicate that bonded carbon fiber reinforced plastics(CFRP) sheets can be used to increase the strength and improve the serviceability of damaged concrete columns at low temperatures. The failure of the specimens,in most cases,takes place within the middle half of the columns. And the failure of strengthened columns is sudden and explosive. The CFRP sheets increase both the axial load capacity and the ultimate concrete compressive strain of the columns. The ultimate loads of strengthened columns at-10,0 and 10 ℃ increase averagely by 9.09%,6.63% and 17.83%,respectively,as compared with those of the control specimens. The axial compressive strength of strengthened columns is related to the curing temperatures. The improvement of axial compressive strength decreases with reducing temperature,and when the temperature drops to a certain value,the improvement increases with falling temperature.
基金the National Natural Science Foundation of China(No.50438010)
文摘According to the phenomenon that the physical properties have,a great effect on the electric capability of carbon fiber reinforced concrete, the author researched the relationship between DC resistance of carbon fiber reinforced concrete and curing age using the two-probe method. Then the effect of insulative area, location and quantity on DC resistance of carbon fiber reinforced concrete was investigated at different curing age with analysis of hydration. The results suggest that DC resistance increases greatly with its curing age, which illustrates the relationship like Gaussian curve. In every curing ages the electric capability of carbon fiber reinforced concrete weakenes with the increase of insulative area. In same curing ages, section and insulative area, the more the quantity of insulation, the stronger the conductibility. The insulative location in optimal position can only result in optimal conductibility.
基金This work was supported by the National High Technology Research and Development Program of China under grant No.2002AA324060by the China Postdoctoral Science Foundation under grant 2003033139.
文摘Concrete containing short carbon-coated-nylon fibers (0.4-2.0 vol. pct) exhibited quasi-ductile response by developing a large damage zone prior to fracture localization. In the damage zone, the material was microcracked but continued to local strain-harden. The carbon-coated-nylon-fiber-reinforced concrete composites (NFRC) were found to be an intrinsically smart concrete that could sense elastic and inelastic deformation, as well as fracture. The fibers served to bridge the cracks and the carbon coating gave the conduction path. The signal provided came from the change in electrical resistance, which was reversible for elastic deformation and irreversible for inelastic deformation and fracture. The resistance decrease was due to the reduction of surface touch resistance between fiber and matrix and the crack closure. The resistance irreversible increase resulted from the crack opening and breakage of the carbon coating on nylon fiber.
基金National Natural Science Foundation of China (No.10272047)the Natural Science Foundation of Guangdong Province (No.020856)
文摘Extensive research has shown that externally bonded carbon fiber reinforced polymer (CFRP) laminates are particularly suitable for improving the fatigue behavior of reinforced concrete (RC) beams. This paper presents the research on flexural ngidity evolvement laws by testing 14 simple-supported RC beams strengthened with carbon fiber laminates (CFL) under cyclic load, and 2 under monotone load as a reference. The cyclic load tests revealed the peak load applied onto the surface of a supported RC beam strengthened with CFL is linear to the logarithm of its fatigue life, and the flexural rigidity evolvement undergoes three distinct phases: a rapid decrease from the start to about 5% of the fatigue life; an even development from .5% to about 99% of the fatigue life; and a succedent rapid decrease to failure. When the ratio of fatigue "cycles to the fatigue life is within 0.0.5 to 0.99, the flexural rigidity varies linearly with the ratio. The peak load does not affect the flexural rigidity evolvement if it is not high enough to make the main reinforcements yield. The dependences of the flexural rigidity of specimens formed in the same group upon their fatigue cycles normalized by fatigue life are almost coincident. This implies the flexural rigidity may be a material parameter independent of the stress level. These relationships of flexural rigidity to fatigue cycles, and fatigue life may be able to provide some hints for fatigue design and fatigue life evaluation of RC member strengthened with CFL; nevertheless the findings still need verifying by more experiments.
文摘This paper presents the results of an experimental investigation on the response of pre-damaged reinforced concrete (RC) beam strengthened in shear using applied-epoxy unidirectional carbon fiber reinforced polymer (CFRP) sheet. The reasearch included four test rectangular simply supported RC beams in shear capacity. One is the control beam, two RC beams are damaged to a predetermined degree from ultimate shear capacity of the control beam, and the last beam is left without pre-damaged and then strengthened with using externally bonded carbon fiber reinforced polymer to upgrade their shear capacity. We focused on the damage degree to beams during strengthening, therefore, only the beams with sidebonded CFRPs strips and horizontal anchored strips were used. The results show the feasibility of using CFRPs to restore or increase the load-carrying capacity in the shear of damaged RC beams. The failure mode of all the CFRP-strengthened beams is debonding of CFRP vertical strips. Two prediction available models in AC1-440 and fib European code were compared with the experimental results.
基金The National Natural Science Foundation of China (No.50238040)
文摘According to the principle of electrical resistance tomography ( ERT), the resistivity distribution of the carbon fiber reinforced concrete (CFRC) in the sensing field can be measured by injecting exciting current and measuring the voltage on the sensor electrode arrays installed on the surface of the object. Therefore, measurement of the resistivity distribution of CFRC is divided into first measuring the boundary conditions and then inversely computing the resistivity distribution. To reach this goal, an ERT system was constructed, which is composed of a sensor array unit, a data acquisition unit and an image reconstruction unit. Simulations of static ERT was performed on set-ups with many objects spread in a homogeneous background, and a simulation of dynamic ERT was also done on a rectangular board, the resistivity of which was changed within a small domain of it. Then, the resistivity distribution of a CFRC sample with a circlar hole as the target was detected by the ERT system. Simulation and experimental results show that the reconstructed ERT image reflects the resistivity distribution or the resistivity change of CFRC structure well. Especially, a small change in resistivity can be identified from the reconstructed images in the simulation of dynamic ERT images.
文摘In this paper,the influence of some important parameters affecting the flexural behavior of reinforced concrete beams strengthened with one layer of carbon fiber reinforced polymer(CFRP)laminate has been studied.For this purpose,six reinforced concrete beams were cast and tested in the laboratory.Based on the obtained data,when CFRP laminate is applied to the tension face,too close to the steel rebar,the flexural strength of the strengthened beam is reduced.In general,the performance of the beam strengthened with one wide CFRP strip is better than that strengthened with two equivalent narrow strips.Ultimate load capacity of each strengthened beam was calculated based on the method given by the ACI 440.2R and compared with the test one.It is concluded that,to avoid the steel rebar-CFRP laminate interaction effect,the CFRP laminate depth-to-the effective depth ratio(df/d)should not be smaller than about 1.17.
文摘The stress-resistance relationship of carbon fiber cement was studied.Attention has been paid to explore the improvement of the stress-resistance sensitivity under cycled stress restriction.The prismy carbon fiber cement sensors were pre-fabricated.The factors such as contents of carbon fibers.silica fume,dispersant and the w/c were taken into account.The electrical resistance variations with the dynamic and static loads were simulated using a strain-controlled test machine.The test results show that there is an optimal fiber content,with which the compression-sensitivity achieves a high level.The addition of silica fume can improve the sensitivity.Under the optimal test conditions,the measured resistances can greatly correspond with the changes of the load.
基金the National Natural Science Foundation of China (No. 50238040).
文摘By heating up the embedded carbon fiber reinforced cement based material (CFRC), the carrying capacity and deformation of concrete member could be adjusted. The relationship between temperature difference and expansion strain of CFRC was demonstrated, and the temperature-deformation-load effect of concrete embedded with CFRC was studied. Heating the CFRC up to different temperatures resulted in different degree of inner pre-stress in concrete. Thus, the load capacity of concrete could be regulated owing to counteracting the pre-stress.
基金Funded by the Henan Province Science and Technology Research Fund Projects (0124150117)
文摘The seepage theory was used to explain the variation between the specific resistance of the carbon fiber reinforced cement concrete and the carbon fiber volume ratio. The electro-dynamic seepage was observed in the cement. The longer the carbon fiber is, the smaller the critical volume to produce the electro-dynamic seepage phenomenon will be. However, the forming and stirring process is harder. In general, the average length of carbon fiber is 5 mm. Under the condition of three-point bending load, the specific resistance changes with the loading process, and a good correlation could be obtained according to the load-deflection relationship. The experimental results reveal that the carbon fiber reinforced cement based composites can be used as sensors to self-diagnoses of the damage.
文摘Due to the inherent property of concrete being very weak in tension, efforts have been made to overcome this deficiency by adding various type of fibers like carbon fiber reinforced polymer (CFRP), glass fiber reinforced polymer (GFRP), polypropylene fiber (PPF) and stainlesssteel fiber (SSF) smeared into the concrete mix. The present study involves experimental investigation on the use of GFRP, CFRP and SSF fibers alone or as combination to improve the mechanical properties of concrete. Furthermore, concrete cylinders were cast and tested for compression and tension using 10% fly ash as cement replacement in all specimens. Besides fiber material types, fiber reinforcement ratios of 1% and 1.5% were tested to investigate the mechanical properties of concrete. In all concrete cylinder tests, the fiber reinforcement ratio of 1% had a significant contribution in increasing the tensile strength as oppose to compressive strength. As a result, the tensile and compressive strengths were increased by 26% and 11%, respectively as compared to the control specimen. Increasing the fiber reinforcement ratio from 1% to 1.5%, resulted in diminishing the mechanical properties of concrete. However, reduction in concrete compressive strength was more prominent than the tensile strength. Furthermore, it was observed that, the crack propagation was decreased with the increase of fiber content when compared to the control specimen.
文摘Concrete, as an essential construction material in the construction industry, is the main component of solid waste. To improve the strength and durability of concrete, some additives can be added into concrete to replace parts of cement. Carbon fiber and silica powder are the most common additives. Under a series of experiments, the effects of temperature, carbon fiber and silica powder on the mechanical properties of concrete were studied under normal circumstances. In this paper, a conclusion on the effects was drawn up mainly through some experimental analyses, so as to discuss the effect laws and provide a reference to manufacture the concrete of high strength and properties.