As an important component,the bond behavior of carbon fiber-reinforced polymer(CFRP)-concrete interface for a reinforced concrete(RC)beam is very significant.In this study,a theoretical model was established to analyz...As an important component,the bond behavior of carbon fiber-reinforced polymer(CFRP)-concrete interface for a reinforced concrete(RC)beam is very significant.In this study,a theoretical model was established to analyze the flexural behavior of CFRP-strengthened RC beams,and the CFRP-concrete interfacial bond-slip relationship under hygrothermal environment was unified into one model.Two failure criteria corresponding to two types of failure modes,i.e.,concrete crushing and intermediate crack(IC)-induced debonding,were developed.Through the theoretical model,the flexural behavior of deflection,interfacial shear stress distribution and ultimate load of a CFRP-strengthened RC beam under hygrothermal environment were obtained and predicted.Moreover,the theoretical model was verified by test results.The results showed that the hygrothermal environment had a significant impact on the CFRP-concrete interface behavior.Compared with the control beam without hygrothermal environment pretreatment,the deflection and ultimate load of the strengthened RC beam decreased by 51.9%and 20%,respectively.展开更多
A method for strengthening damaged tubular steel T-joints under axial compression by wrapping them with carbon fiber-reinforced polymer(CFRP)sheets was proposed and evaluated.The influence of the CFRP strengthening on...A method for strengthening damaged tubular steel T-joints under axial compression by wrapping them with carbon fiber-reinforced polymer(CFRP)sheets was proposed and evaluated.The influence of the CFRP strengthening on the failure mode and load capacity of T-joints with different degrees of damage was investigated using experiments and finite element analyses.Five T-joints were physically tested:one bare joint to obtain the peak load and corresponding displacement(D1m),two reinforced joints to provide a reference,and two pre-damaged then retrofitted joints to serve as the primary research objects.The ratio of the pre-loaded specimen chord displacement to the value of D1m was considered to be the degree of damage of the two retrofitted joints,and was set to 0.80 and 1.20.The results demonstrate that the maximum capacity of the retrofitted specimen was increased by 0.83%–15.06%over the corresponding unreinforced specimens.However,the capacity of the retrofitted specimen was 2.51%–22.77%lesser compared with that of the directly reinforced specimens.Next,111 numerical analysis models(0.63≤b≤0.76,9.70≤g≤16.92)were established to parametrically evaluate the effects of different geometric and strengthening parameters on the load capacity of strengthened tubular T-joints under different degrees of damage.The numerical analysis results revealed that the development of equivalent plastic strain at the selected measuring points was moderated by strengthening with CFRP wrapping,and indicated the optimal CFRP strengthening thickness and wrapping orientation according to tubular T-joint parameters.Finally,reasonable equations for calculating the load capacity of CFRP-strengthened joints were proposed and demonstrated to provide accurate results.The findings of this study can be used to inform improved CFRP strengthening of damaged tubular steel structures.展开更多
Experimental results of 29 axially loaded fiber-reinforced polymer sheet (FS) confined concrete columns and two reference plain concrete columns are introduced. Twenty four column specimens were confined with carbon f...Experimental results of 29 axially loaded fiber-reinforced polymer sheet (FS) confined concrete columns and two reference plain concrete columns are introduced. Twenty four column specimens were confined with carbon fiber sheet (CFS) and five column specimens were hybrid confined with both CFS and glass fiber sheet (GFS). The influence of aspect ratio, FS material, initial axial force ratio, and FS confine-ment degree on the strength and deformation of columns were studied. Based on the experimental results, the equations of complete stress-strain curve of CFS confined concrete are proposed. These equations are suitable for the nonlinear analysis of square and rectangular section columns. Suggestions of applying FS to confine concrete columns are presented.展开更多
基金The authors would like to acknowledge the financial support from the National Natural Science Foundation of China(Nos.11872185,11627802,51678249,11132004)the Natural Science Foundation of Guangdong Province(No.2019A1515012222).
文摘As an important component,the bond behavior of carbon fiber-reinforced polymer(CFRP)-concrete interface for a reinforced concrete(RC)beam is very significant.In this study,a theoretical model was established to analyze the flexural behavior of CFRP-strengthened RC beams,and the CFRP-concrete interfacial bond-slip relationship under hygrothermal environment was unified into one model.Two failure criteria corresponding to two types of failure modes,i.e.,concrete crushing and intermediate crack(IC)-induced debonding,were developed.Through the theoretical model,the flexural behavior of deflection,interfacial shear stress distribution and ultimate load of a CFRP-strengthened RC beam under hygrothermal environment were obtained and predicted.Moreover,the theoretical model was verified by test results.The results showed that the hygrothermal environment had a significant impact on the CFRP-concrete interface behavior.Compared with the control beam without hygrothermal environment pretreatment,the deflection and ultimate load of the strengthened RC beam decreased by 51.9%and 20%,respectively.
基金This research work was supported and funded by Shandong Provincial Science and Technology Plan Project(No.J13LG05).
文摘A method for strengthening damaged tubular steel T-joints under axial compression by wrapping them with carbon fiber-reinforced polymer(CFRP)sheets was proposed and evaluated.The influence of the CFRP strengthening on the failure mode and load capacity of T-joints with different degrees of damage was investigated using experiments and finite element analyses.Five T-joints were physically tested:one bare joint to obtain the peak load and corresponding displacement(D1m),two reinforced joints to provide a reference,and two pre-damaged then retrofitted joints to serve as the primary research objects.The ratio of the pre-loaded specimen chord displacement to the value of D1m was considered to be the degree of damage of the two retrofitted joints,and was set to 0.80 and 1.20.The results demonstrate that the maximum capacity of the retrofitted specimen was increased by 0.83%–15.06%over the corresponding unreinforced specimens.However,the capacity of the retrofitted specimen was 2.51%–22.77%lesser compared with that of the directly reinforced specimens.Next,111 numerical analysis models(0.63≤b≤0.76,9.70≤g≤16.92)were established to parametrically evaluate the effects of different geometric and strengthening parameters on the load capacity of strengthened tubular T-joints under different degrees of damage.The numerical analysis results revealed that the development of equivalent plastic strain at the selected measuring points was moderated by strengthening with CFRP wrapping,and indicated the optimal CFRP strengthening thickness and wrapping orientation according to tubular T-joint parameters.Finally,reasonable equations for calculating the load capacity of CFRP-strengthened joints were proposed and demonstrated to provide accurate results.The findings of this study can be used to inform improved CFRP strengthening of damaged tubular steel structures.
基金Supported by the National Natural Science Foundation of China (No. 50238030)
文摘Experimental results of 29 axially loaded fiber-reinforced polymer sheet (FS) confined concrete columns and two reference plain concrete columns are introduced. Twenty four column specimens were confined with carbon fiber sheet (CFS) and five column specimens were hybrid confined with both CFS and glass fiber sheet (GFS). The influence of aspect ratio, FS material, initial axial force ratio, and FS confine-ment degree on the strength and deformation of columns were studied. Based on the experimental results, the equations of complete stress-strain curve of CFS confined concrete are proposed. These equations are suitable for the nonlinear analysis of square and rectangular section columns. Suggestions of applying FS to confine concrete columns are presented.