According to computer numerical simulation for measuring atmosphere carbon potential by electric resistance method (hot-wire method) and the experimental data, the paper point out that the measuring result dose not d...According to computer numerical simulation for measuring atmosphere carbon potential by electric resistance method (hot-wire method) and the experimental data, the paper point out that the measuring result dose not directly reflect the atmosphere carbon potential (Cg) but the average carbon content, and as a result, the change of electric resistance obviously lag to that of the atmosphere carbon potential. In order to correctly control the carbon potential by electric resistance method, the authors bring forward a function which is a better expression for the relationship between the average carbon content of the wire and the atmosphere carbon potential and ensures good carbon potential control.展开更多
文摘According to computer numerical simulation for measuring atmosphere carbon potential by electric resistance method (hot-wire method) and the experimental data, the paper point out that the measuring result dose not directly reflect the atmosphere carbon potential (Cg) but the average carbon content, and as a result, the change of electric resistance obviously lag to that of the atmosphere carbon potential. In order to correctly control the carbon potential by electric resistance method, the authors bring forward a function which is a better expression for the relationship between the average carbon content of the wire and the atmosphere carbon potential and ensures good carbon potential control.