Objective:To investigate the contribution of N-terminal pro B-type natriuretic peptide(NT-pro BNP)and troponin Ⅰ to mortality in children with dengue shock syndrome.Methods:A longitudinal study was conducted on child...Objective:To investigate the contribution of N-terminal pro B-type natriuretic peptide(NT-pro BNP)and troponin Ⅰ to mortality in children with dengue shock syndrome.Methods:A longitudinal study was conducted on children with dengue shock syndrome in a hospital in southern Vietnam.Detailed clinical histories,physical examinations,and laboratory parameters,including NT-pro BNP and troponin Ⅰ,were recorded.A comparison between survival and non-survival was carried out to identify factors influencing mortality.Results:A total of 107 patients with a median age of 9 years were included in the study.Among them,63.6%(68/107)presented with compensated shock,36.4%(39/107)had hypotensive shock,23.4%(25/107)required mechanical ventilation,and 12.1%(13/107)died.The NT-pro BNP levels were 3.9 pmol/L(IQR:1.9,10.3)and 15.2 pmol/L(5.8,46.3),while the median high sensitivity troponin Ⅰ levels were 20 pg/L(6,95)and 62 pg/L(12,325)at the first and second measurements,respectively.The mortality group exhibited higher rates of hypotensive shock,prolonged shock,lactate levels,liver damage,NT-pro BNP,and troponin Ⅰ levels.Hypotensive shock(OR 12.96,95%CI 2.70-62.30,P=0.004),prolonged shock(OR 39.40,95%CI 6.68-232.70,P<0.001),AST>1000 IU/L(OR 9.50,95%CI 2.63-34.34,P=0.041),and NT-pro BNP>7 pmol/L(OR 44.40,95%CI 5.44-362.20,P=0.001)were identified as predictive factors for mortality in dengue shock syndrome.Conclusions:The NT-pro BNP level could serve as a potential biomarker for predicting mortality in children with dengue shock syndrome.展开更多
Sensitive detection and precise quantitation of trace-level crucial biomarkers in a complex sample matrix has become an important area of research.For example,the detection of high-sensitivity cardiac troponin I (hs-c...Sensitive detection and precise quantitation of trace-level crucial biomarkers in a complex sample matrix has become an important area of research.For example,the detection of high-sensitivity cardiac troponin I (hs-cTnI) is strongly recommended in clinical guidelines for early diagnosis of acute myocardial infarction.Based on the use of an electrode modified by single-walled carbon nanotubes (SWCNTs) and a Ru(bpy)32+-doped silica nanoparticle (Ru@SiO2)/tripropylamine (TPA) system,a novel type of electrochemiluminescent (ECL) magnetoimmunosensor is developed for ultrasensitive detection of hs-cTnI.In this approach,a large amount of[Ru(bpy)3]2+is loaded in SiO2(silica nanoparticles) as luminophores with high luminescent efficiency and SWCNTs as electrode surface modification material with excellent electrooxidation ability for TPA.Subsequently,a hierarchical micropillar array of microstructures is fabricated with a magnet placed at each end to efficiently confine a single layer of immunomagnetic microbeads on the surface of the electrode and enable 7.5-fold signal enhancement In particular,the use of transparent SWCNTs to modify a transparent ITO electrode provides a two-order-of-magnitude ECL signal amplification.A good linear calibration curve is developed for hs-cTnI concentrations over a wide range from 10 fg/ml to 10 ng/ml,with the limit of detection calculated as 8.720 fg/ml (S/N=3).This ultrasensitive immunosensor exhibits superior detection performance with remarkable stability,reproducibility,and selectivity.Satisfactory recoveries are obtained in the detection of hs-cTnI in human serum,providing a potentia analysis protocol for clinical applications.展开更多
Trypanosomosis is major drawback to profitable livestock production in sub-Sahara African, including Nigeria. Knowledge of the cytokines production in the phase of natural infection may help to better diagnose, treat ...Trypanosomosis is major drawback to profitable livestock production in sub-Sahara African, including Nigeria. Knowledge of the cytokines production in the phase of natural infection may help to better diagnose, treat and prevent bovine trypanosomosis. The purpose of the this study was to determine the levels of interferon-gamma (IFN-γ), interleukin-10 (IL-10) and cardiac troponin–I (cTnI) in the sera of cattle naturally infected with T. brucei, T. congolense and T. vivax and correlate these levels with parasitaemia and PCV of the infected animals. Five milliliter of blood samples were collected via the jugular vein from 411 randomly selected cattle into EDTA and non-citrated bottle. PCV was determined manually using HCT. Trypansomes were detected and characterized by microscopy and PCR, respectively. Serum levels of IFN-γ, IL-10 and cTnI were determined using commercial ELISA kit. Data were summarized using descriptive statistic and significance of differences determined by ANOVA. Of the 62 samples positive for trypanosomes by microscopy, 50 samples were confirmed to species level by PCR. The sera levels of IFN-γ, IL-10 and cTnI of infected cattle were higher than non-infected cattle. The differences were not significant (p γ, IL-10 and cTnI in cattle with natural trypanosomosis. Further investigation is required to understand the specific effect of trypanosomes on myocardiac integrity and interaction between the two cytokines in natural trypanosomosis in cattle.展开更多
High-sensitivity cardiac troponin(hs-cTn) assays are increasingly being used in many countries worldwide,however,a generally accepted definition of high-sen-sitivity is still pending.These assays enable cTn mea-sureme...High-sensitivity cardiac troponin(hs-cTn) assays are increasingly being used in many countries worldwide,however,a generally accepted definition of high-sen-sitivity is still pending.These assays enable cTn mea-surement with a high degree of analytical sensitivity with a low analytical imprecision at the low measuring range of cTn assays(coefficient of variation of < 10% at the 99th percentile upper reference limit).One of the most important advantages of these new assays is that they allow novel,more rapid approaches to rule in or rule out acute coronary syndromes(ACSs) than with previous cTn assay generations which are still more commonly used in practice worldwide.hs-cTn is also more sensitive for the detection of myocardial damage unrelated to acute myocardial ischemia.Therefore,the increase in early diagnostic sensitivity of hs-cTn assays for ACS comes at the cost of a reduced ACS specificity,because more patients with other causes of acute or chronic myocardial injury without overt myocardial isch-emia are detected than with previous cTn assays.As hs-cTn assays are increasingly being adopted in clinical practice and more hs-cTn assays are being developed,this review attempts to synthesize the available clinical data to make recommendations for their everyday clini-cal routine use.展开更多
BACKGROUND:Early reperfusion can effectively treat acute myocardial infarction(AMI) and reduce the mortality signif icantly. This study aimed to compare the role of plasma microRNA-1(miR-1) and cardiac troponin T(cTnT...BACKGROUND:Early reperfusion can effectively treat acute myocardial infarction(AMI) and reduce the mortality signif icantly. This study aimed to compare the role of plasma microRNA-1(miR-1) and cardiac troponin T(cTnT) in early diagnosis of AMI patients.METHODS:From May 2011 to May 2012,plasma samples were collected from 56 AMI patients and 28 non-AMI controls. The expression of plasma miR-1 was measured by quantitative reverse transcription-polymerase chain reaction(qRT-PCR),and the level of plasma cTnT was measured using electrochemiluminescence-based methods on an Elecsys 2010 Immunoassay Analyzer. SPSS 16.0 was used for the statistical analysis of the results. Data were expressed as mean±standard deviation unless otherwise described. The differences about clinical characteristics between the AMI patients and controls were tested using Student's t test or Fisher's exact test. The Mann-Whitney U test was conducted to compare the expression of microRNAs between the AMI patients and controls. MicroRNAs expression between different intervals of the AMI patients was compared using Wilcoxon's signed-rank test. The receiver operating characteristic(ROC) curve was established to discriminate the AMI patients from the controls.RESULTS:In the present study,the expression of plasma miR-1 was signifi cantly increased in the AMI patients compared with the healthy controls(P<0.01). The plasma miR-1 in the AMI patients decreased to the normal level at 14 days(P>0.05). The expression of plasma miR-1 was not related to the clinical characteristics of the study population(P>0.05). ROC curve analyses demonstrated that miR-1 was specifi c and sensitive for the early diagnosis of AMI,but not superior to cTnT.CONCLUSION:Plasma miR-1 could be used in the early diagnosis of AMI,but it is similar to cTnT.展开更多
Convenient,rapid,and accurate detection of cardiac troponin I(cTnI)is crucial in early diagnosis of acute myocardial infarction(AMI).A paper-based electrochemical immunosensor is a promising choice in this field,becau...Convenient,rapid,and accurate detection of cardiac troponin I(cTnI)is crucial in early diagnosis of acute myocardial infarction(AMI).A paper-based electrochemical immunosensor is a promising choice in this field,because of the flexibility,porosity,and cost-efficacy of the paper.However,paper is poor in electronic conductivity and surface functionality.Herein,we report a paper-based electrochemical immunosensor for the label-free detection of cTnI with the working electrode modified by MXene(Ti_(3)C_(2))nanosheets.In order to immobilize the bio-receptor(anti-cTnI)on the MXene-modified working electrode,the MXene nanosheets were functionalized by aminosilane,and the functionalized MXene was immobilized onto the surface of the working electrode through Nafion.The large surface area of the MXene nanosheets facilitates the immobilization of antibodies,and the excellent conductivity facilitates the electron transfer between the electrochemical species and the underlying electrode surface.As a result,the paper-based immunosensor could detect cTnI within a wide range of 5-100 ng/mL with a detection limit of 0.58 ng/mL.The immunosensor also shows outstanding selectivity and good repeatability.Our MXene-modified paper-based electrochemical immunosensor enables fast and sensitive detection of cTnI,which may be used in real-time and cost-efficient monitoring of AMI diseases in clinics.展开更多
文摘Objective:To investigate the contribution of N-terminal pro B-type natriuretic peptide(NT-pro BNP)and troponin Ⅰ to mortality in children with dengue shock syndrome.Methods:A longitudinal study was conducted on children with dengue shock syndrome in a hospital in southern Vietnam.Detailed clinical histories,physical examinations,and laboratory parameters,including NT-pro BNP and troponin Ⅰ,were recorded.A comparison between survival and non-survival was carried out to identify factors influencing mortality.Results:A total of 107 patients with a median age of 9 years were included in the study.Among them,63.6%(68/107)presented with compensated shock,36.4%(39/107)had hypotensive shock,23.4%(25/107)required mechanical ventilation,and 12.1%(13/107)died.The NT-pro BNP levels were 3.9 pmol/L(IQR:1.9,10.3)and 15.2 pmol/L(5.8,46.3),while the median high sensitivity troponin Ⅰ levels were 20 pg/L(6,95)and 62 pg/L(12,325)at the first and second measurements,respectively.The mortality group exhibited higher rates of hypotensive shock,prolonged shock,lactate levels,liver damage,NT-pro BNP,and troponin Ⅰ levels.Hypotensive shock(OR 12.96,95%CI 2.70-62.30,P=0.004),prolonged shock(OR 39.40,95%CI 6.68-232.70,P<0.001),AST>1000 IU/L(OR 9.50,95%CI 2.63-34.34,P=0.041),and NT-pro BNP>7 pmol/L(OR 44.40,95%CI 5.44-362.20,P=0.001)were identified as predictive factors for mortality in dengue shock syndrome.Conclusions:The NT-pro BNP level could serve as a potential biomarker for predicting mortality in children with dengue shock syndrome.
基金The authors acknowledge financial support from the National Natural Science Foundation of China(Grant Nos.62001460,31971368,12202461,and 22104148)the Guangdong Regional Joint Funds for Young Scientists(Grant Nos.2020A1515110201 and 2020A1515110368)+2 种基金Guangdong Provincial General Funding(Grant No.2021A1515220156)Guangdong Basic and Applied Basic Research Funding-Regional Joint Fund(Grant No.2020B1515120040)Shenzhen Science and Technology Research Funding(Grant Nos.JSGG20201103153801005,JSGG20191115141601721,ZDSYS20220527171406014,JCYJ20220818101412027,JCYJ20200109115635440,and JCYJ 20200109115408041).
文摘Sensitive detection and precise quantitation of trace-level crucial biomarkers in a complex sample matrix has become an important area of research.For example,the detection of high-sensitivity cardiac troponin I (hs-cTnI) is strongly recommended in clinical guidelines for early diagnosis of acute myocardial infarction.Based on the use of an electrode modified by single-walled carbon nanotubes (SWCNTs) and a Ru(bpy)32+-doped silica nanoparticle (Ru@SiO2)/tripropylamine (TPA) system,a novel type of electrochemiluminescent (ECL) magnetoimmunosensor is developed for ultrasensitive detection of hs-cTnI.In this approach,a large amount of[Ru(bpy)3]2+is loaded in SiO2(silica nanoparticles) as luminophores with high luminescent efficiency and SWCNTs as electrode surface modification material with excellent electrooxidation ability for TPA.Subsequently,a hierarchical micropillar array of microstructures is fabricated with a magnet placed at each end to efficiently confine a single layer of immunomagnetic microbeads on the surface of the electrode and enable 7.5-fold signal enhancement In particular,the use of transparent SWCNTs to modify a transparent ITO electrode provides a two-order-of-magnitude ECL signal amplification.A good linear calibration curve is developed for hs-cTnI concentrations over a wide range from 10 fg/ml to 10 ng/ml,with the limit of detection calculated as 8.720 fg/ml (S/N=3).This ultrasensitive immunosensor exhibits superior detection performance with remarkable stability,reproducibility,and selectivity.Satisfactory recoveries are obtained in the detection of hs-cTnI in human serum,providing a potentia analysis protocol for clinical applications.
文摘Trypanosomosis is major drawback to profitable livestock production in sub-Sahara African, including Nigeria. Knowledge of the cytokines production in the phase of natural infection may help to better diagnose, treat and prevent bovine trypanosomosis. The purpose of the this study was to determine the levels of interferon-gamma (IFN-γ), interleukin-10 (IL-10) and cardiac troponin–I (cTnI) in the sera of cattle naturally infected with T. brucei, T. congolense and T. vivax and correlate these levels with parasitaemia and PCV of the infected animals. Five milliliter of blood samples were collected via the jugular vein from 411 randomly selected cattle into EDTA and non-citrated bottle. PCV was determined manually using HCT. Trypansomes were detected and characterized by microscopy and PCR, respectively. Serum levels of IFN-γ, IL-10 and cTnI were determined using commercial ELISA kit. Data were summarized using descriptive statistic and significance of differences determined by ANOVA. Of the 62 samples positive for trypanosomes by microscopy, 50 samples were confirmed to species level by PCR. The sera levels of IFN-γ, IL-10 and cTnI of infected cattle were higher than non-infected cattle. The differences were not significant (p γ, IL-10 and cTnI in cattle with natural trypanosomosis. Further investigation is required to understand the specific effect of trypanosomes on myocardiac integrity and interaction between the two cytokines in natural trypanosomosis in cattle.
文摘High-sensitivity cardiac troponin(hs-cTn) assays are increasingly being used in many countries worldwide,however,a generally accepted definition of high-sen-sitivity is still pending.These assays enable cTn mea-surement with a high degree of analytical sensitivity with a low analytical imprecision at the low measuring range of cTn assays(coefficient of variation of < 10% at the 99th percentile upper reference limit).One of the most important advantages of these new assays is that they allow novel,more rapid approaches to rule in or rule out acute coronary syndromes(ACSs) than with previous cTn assay generations which are still more commonly used in practice worldwide.hs-cTn is also more sensitive for the detection of myocardial damage unrelated to acute myocardial ischemia.Therefore,the increase in early diagnostic sensitivity of hs-cTn assays for ACS comes at the cost of a reduced ACS specificity,because more patients with other causes of acute or chronic myocardial injury without overt myocardial isch-emia are detected than with previous cTn assays.As hs-cTn assays are increasingly being adopted in clinical practice and more hs-cTn assays are being developed,this review attempts to synthesize the available clinical data to make recommendations for their everyday clini-cal routine use.
基金supported by grants from the National Natural Science Foundation of China(81071030)the Science and Technology Foundation of Guangdong Province(2011B080701006)
文摘BACKGROUND:Early reperfusion can effectively treat acute myocardial infarction(AMI) and reduce the mortality signif icantly. This study aimed to compare the role of plasma microRNA-1(miR-1) and cardiac troponin T(cTnT) in early diagnosis of AMI patients.METHODS:From May 2011 to May 2012,plasma samples were collected from 56 AMI patients and 28 non-AMI controls. The expression of plasma miR-1 was measured by quantitative reverse transcription-polymerase chain reaction(qRT-PCR),and the level of plasma cTnT was measured using electrochemiluminescence-based methods on an Elecsys 2010 Immunoassay Analyzer. SPSS 16.0 was used for the statistical analysis of the results. Data were expressed as mean±standard deviation unless otherwise described. The differences about clinical characteristics between the AMI patients and controls were tested using Student's t test or Fisher's exact test. The Mann-Whitney U test was conducted to compare the expression of microRNAs between the AMI patients and controls. MicroRNAs expression between different intervals of the AMI patients was compared using Wilcoxon's signed-rank test. The receiver operating characteristic(ROC) curve was established to discriminate the AMI patients from the controls.RESULTS:In the present study,the expression of plasma miR-1 was signifi cantly increased in the AMI patients compared with the healthy controls(P<0.01). The plasma miR-1 in the AMI patients decreased to the normal level at 14 days(P>0.05). The expression of plasma miR-1 was not related to the clinical characteristics of the study population(P>0.05). ROC curve analyses demonstrated that miR-1 was specifi c and sensitive for the early diagnosis of AMI,but not superior to cTnT.CONCLUSION:Plasma miR-1 could be used in the early diagnosis of AMI,but it is similar to cTnT.
基金financially supported by the National Key R&D Program of China(2017YFA0204700)the Joint Research Funds of Department of Science&Technology of Shaanxi Province and Northwestern Polytechnical University(2020GXLH-Z-021)+1 种基金the China-Sweden Joint Mobility Project(51811530018)the Fundamental Research Funds for the Central Universities.
文摘Convenient,rapid,and accurate detection of cardiac troponin I(cTnI)is crucial in early diagnosis of acute myocardial infarction(AMI).A paper-based electrochemical immunosensor is a promising choice in this field,because of the flexibility,porosity,and cost-efficacy of the paper.However,paper is poor in electronic conductivity and surface functionality.Herein,we report a paper-based electrochemical immunosensor for the label-free detection of cTnI with the working electrode modified by MXene(Ti_(3)C_(2))nanosheets.In order to immobilize the bio-receptor(anti-cTnI)on the MXene-modified working electrode,the MXene nanosheets were functionalized by aminosilane,and the functionalized MXene was immobilized onto the surface of the working electrode through Nafion.The large surface area of the MXene nanosheets facilitates the immobilization of antibodies,and the excellent conductivity facilitates the electron transfer between the electrochemical species and the underlying electrode surface.As a result,the paper-based immunosensor could detect cTnI within a wide range of 5-100 ng/mL with a detection limit of 0.58 ng/mL.The immunosensor also shows outstanding selectivity and good repeatability.Our MXene-modified paper-based electrochemical immunosensor enables fast and sensitive detection of cTnI,which may be used in real-time and cost-efficient monitoring of AMI diseases in clinics.