A modular system of cascaded converters based on model predictive control(MPC)is proposed to meet the application requirements ofmultiple voltage levels and electrical isolation in renewable energy generation systems....A modular system of cascaded converters based on model predictive control(MPC)is proposed to meet the application requirements ofmultiple voltage levels and electrical isolation in renewable energy generation systems.The system consists of a Buck/Boost+CLLLC cascaded converter as a submodule,which is combined in series and parallel on the input and output sides to achieve direct-current(DC)voltage transformation,bidirectional energy flow,and electrical isolation.The CLLLC converter operates in DC transformer mode in the submodule,while the Buck/Boost converter participates in voltage regulation.This article establishes a suitable mathematical model for the proposed system topology,and uses MPC to control the system based on this mathematical model.Module parameters are designed and calculated,and simulation is built in MATLAB/Simulink to complete the simulation comparison experiment between MPC and traditional proportional integral(PI)control.Finally,a physical experimental platform is built to complete the physical comparison experiment.The simulation and physical experimental results prove that the control accuracy and response speed ofMPC are better than traditional PI control strategy.展开更多
Cascaded multilevel converters built with integrated modules have many advantages such as increased power density,flexible distributed control,multi-functionality,increased reliability and short design cycles.However,...Cascaded multilevel converters built with integrated modules have many advantages such as increased power density,flexible distributed control,multi-functionality,increased reliability and short design cycles.However,the system performance will be affected due to the synchronization errors among each integrated modules.This paper analyzes the impact of the three kinds of synchronization errors on the whole system performance,as well as detailed synchronization implementation.Some valuable conclusions are derived from the theoretical analysis,simulations and experimental results.展开更多
With the high penetration of renewable energy,new challenges,such as power fluctuation suppression and inertial support capability,have arisen in the power sector.Battery energy storage systems play an essential role ...With the high penetration of renewable energy,new challenges,such as power fluctuation suppression and inertial support capability,have arisen in the power sector.Battery energy storage systems play an essential role in renewable energy integration.In this paper,a distributed virtual synchronous generator(VSG)control method for a battery energy storage system(BESS)with a cascaded H-bridge converter in a grid-connected mode is proposed.The VSG is developed without communication dependence,and state-of-charge(SOC)balancing control is achieved using the distributed average algorithm.Owing to the low varying speed of SOC,the bandwidth of the distributed communication networks is extremely slow,which decreases the cost.Therefore,the proposed method can simultaneously provide inertial support and accurate SOC balancing.The stability is also proved using root locus analysis.Finally,simulations under different conditions are carried out to verify the effectiveness of the proposed method.展开更多
Forhigh power applications,multilevel converters have many advantages in comparison with other circuit topologies with output transformers. Cascaded inverters are one type of multilevel converters,they are easy to imp...Forhigh power applications,multilevel converters have many advantages in comparison with other circuit topologies with output transformers. Cascaded inverters are one type of multilevel converters,they are easy to implement,very suitable for modularized layout and packaging.Their manufacturing cost is low.A multilevel PWM technique,called as General Technique of Selected Harmonics Elimination (GTSHE) ,is proposed in the paper. A general harmonic elimination equation for N cells,M pulses per half cycle,nth harmonic is derived,and verified by simulation results.展开更多
The interaction between the source and load converters in cascaded DC-DC converters may cause instability.Thus,improving the stability of cascaded DC-DC converters is important.To solve the above-mentioned problem,a f...The interaction between the source and load converters in cascaded DC-DC converters may cause instability.Thus,improving the stability of cascaded DC-DC converters is important.To solve the above-mentioned problem,a flowchart to improve the control method is established by calculating the eigenvalue sensitivity of a time-domain model of cascaded DC-DC converters.Further,an additional voltage-error mutual feedback control method is firstly proposed based on the flowchart provided in this study to improve the stability of cascaded DC-DC converters.Subsequently,the influence of the proposed mutual feedback control on the stability of cascaded DC-DC converters is analyzed.Finally,the effectiveness of the proposed control method is verified by simulation and experiment.展开更多
A Cascade H Bridge (CHB) is evaluated for both electric vehicle motor traction control and off-vehicle charging against the Power ElectronicsUK Automotive Challenge for cost and mass for the year 2035. By combining th...A Cascade H Bridge (CHB) is evaluated for both electric vehicle motor traction control and off-vehicle charging against the Power ElectronicsUK Automotive Challenge for cost and mass for the year 2035. By combining the power electronics with batteries using low-voltage MOSFET transistors in a series cascade arrangement the cost and mass targets could be met 12 years earlier (in 2023 and 20 times lighter if an application specific integrated circuit (ASIC) is used. A 200 kW peak reference car was used to evaluate cost and mass benefits using four different topologies of power electronics. Vehicle installation is shown to be simplified as only passive cooling is required removing the need for liquid cooling systems and the arrangement is inherently safe;no high voltages are present when the vehicle is stationary. The inherently higher efficiency of CHB increases vehicle range. The converter with integrated batteries can also behave as an integrated on-board battery charger delivering additional off-vehicle benefits by removing the need for costly external chargers.展开更多
This paper presents a novel inter-cluster direct current(DC)capacitor voltage balancing control scheme for the single-star configured modular multilevel cascaded converter(MMCC)-based static synchronous compensator(ST...This paper presents a novel inter-cluster direct current(DC)capacitor voltage balancing control scheme for the single-star configured modular multilevel cascaded converter(MMCC)-based static synchronous compensator(STATCOM)under unbalanced grid voltage.The negative-sequence component of grid voltage at the point of common connection(PCC)causes unbalanced active power flow in the phase limbs of converter.This leads to the imbalance of DC voltages of the sub-module capacitors across the MMCC phases,and consequently,the malfunction of converter.The proposed solution is to inject both negative-sequence current(NSC)and zero-sequence voltage(ZSV)into the phase limbs of MMCC.A quantification factor Qf is used to achieve the sharing of inter-cluster active pow-er between the NSC and ZSV injection methods.Accurate determination of the quantification factor has been presented.In addition to maintaining the DC voltages of sub-module capacitor across the MMCC phases balanced,it also prevents the overcurrent and overvoltage of converter by injecting NSC and ZSV with the right proportion.The control scheme is validated on a 3.54 kV 1.2 MVA power system using MMCC-based STATCOM with 3-level bridge cells as sub-modules.The results show that the proposed scheme provides superior effectiveness in eliminating the voltage imbalance of DC capacitor in the phase limb while maintaining low voltage and current ratings.展开更多
Multi-level converters have been used extensively in modern industry which calls for energy conversion with high-power and high-or medium-voltage.Because of its modularity and scalability,the multi-level converter wit...Multi-level converters have been used extensively in modern industry which calls for energy conversion with high-power and high-or medium-voltage.Because of its modularity and scalability,the multi-level converter with modular structure can be extended to different voltage levels and has a variety of forms in practical applications.It has attracted much attention from academia in the past decade,however,as a result of the numerous vulnerable power electronics sub-modules,significant challenges remain with regards to reliability.After summarizing the current research status of modular multilevel cascade converters,the main issues of reliability are reviewed in the paper.Firstly,the failure cases are thoroughly surveyed and classified,and the main failure causes are analyzed.Secondly,the reliability evaluation methods are reviewed and applied to the modular multilevel cascade converters.Thirdly,some promising measures to improve the reliability are presented and discussed,including parameter selection,redundancy design,fault-tolerant control and so on.Then,a complete reliability-oriented design procedure for the modular multilevel cascade converters is proposed.Finally,the challenges and opportunities to improve the reliability are concluded.展开更多
基金supported by the National Key Research and Development Plan,Grant/Award Number:2018YFB1503005.
文摘A modular system of cascaded converters based on model predictive control(MPC)is proposed to meet the application requirements ofmultiple voltage levels and electrical isolation in renewable energy generation systems.The system consists of a Buck/Boost+CLLLC cascaded converter as a submodule,which is combined in series and parallel on the input and output sides to achieve direct-current(DC)voltage transformation,bidirectional energy flow,and electrical isolation.The CLLLC converter operates in DC transformer mode in the submodule,while the Buck/Boost converter participates in voltage regulation.This article establishes a suitable mathematical model for the proposed system topology,and uses MPC to control the system based on this mathematical model.Module parameters are designed and calculated,and simulation is built in MATLAB/Simulink to complete the simulation comparison experiment between MPC and traditional proportional integral(PI)control.Finally,a physical experimental platform is built to complete the physical comparison experiment.The simulation and physical experimental results prove that the control accuracy and response speed ofMPC are better than traditional PI control strategy.
基金Project supported by the National Natural Science Foundation of China (No. 50277035)the Natural Science Foundation of Zheji-ang Province (No. Z104441),China
文摘Cascaded multilevel converters built with integrated modules have many advantages such as increased power density,flexible distributed control,multi-functionality,increased reliability and short design cycles.However,the system performance will be affected due to the synchronization errors among each integrated modules.This paper analyzes the impact of the three kinds of synchronization errors on the whole system performance,as well as detailed synchronization implementation.Some valuable conclusions are derived from the theoretical analysis,simulations and experimental results.
基金This work was supported by National Natural Science Foundation of China under Grant U1909201,Distributed active learning theory and method for operational situation awareness of active distribution network.
文摘With the high penetration of renewable energy,new challenges,such as power fluctuation suppression and inertial support capability,have arisen in the power sector.Battery energy storage systems play an essential role in renewable energy integration.In this paper,a distributed virtual synchronous generator(VSG)control method for a battery energy storage system(BESS)with a cascaded H-bridge converter in a grid-connected mode is proposed.The VSG is developed without communication dependence,and state-of-charge(SOC)balancing control is achieved using the distributed average algorithm.Owing to the low varying speed of SOC,the bandwidth of the distributed communication networks is extremely slow,which decreases the cost.Therefore,the proposed method can simultaneously provide inertial support and accurate SOC balancing.The stability is also proved using root locus analysis.Finally,simulations under different conditions are carried out to verify the effectiveness of the proposed method.
文摘Forhigh power applications,multilevel converters have many advantages in comparison with other circuit topologies with output transformers. Cascaded inverters are one type of multilevel converters,they are easy to implement,very suitable for modularized layout and packaging.Their manufacturing cost is low.A multilevel PWM technique,called as General Technique of Selected Harmonics Elimination (GTSHE) ,is proposed in the paper. A general harmonic elimination equation for N cells,M pulses per half cycle,nth harmonic is derived,and verified by simulation results.
基金Supported by National Natural Science Foundation of China(51577010,51777012).
文摘The interaction between the source and load converters in cascaded DC-DC converters may cause instability.Thus,improving the stability of cascaded DC-DC converters is important.To solve the above-mentioned problem,a flowchart to improve the control method is established by calculating the eigenvalue sensitivity of a time-domain model of cascaded DC-DC converters.Further,an additional voltage-error mutual feedback control method is firstly proposed based on the flowchart provided in this study to improve the stability of cascaded DC-DC converters.Subsequently,the influence of the proposed mutual feedback control on the stability of cascaded DC-DC converters is analyzed.Finally,the effectiveness of the proposed control method is verified by simulation and experiment.
文摘A Cascade H Bridge (CHB) is evaluated for both electric vehicle motor traction control and off-vehicle charging against the Power ElectronicsUK Automotive Challenge for cost and mass for the year 2035. By combining the power electronics with batteries using low-voltage MOSFET transistors in a series cascade arrangement the cost and mass targets could be met 12 years earlier (in 2023 and 20 times lighter if an application specific integrated circuit (ASIC) is used. A 200 kW peak reference car was used to evaluate cost and mass benefits using four different topologies of power electronics. Vehicle installation is shown to be simplified as only passive cooling is required removing the need for liquid cooling systems and the arrangement is inherently safe;no high voltages are present when the vehicle is stationary. The inherently higher efficiency of CHB increases vehicle range. The converter with integrated batteries can also behave as an integrated on-board battery charger delivering additional off-vehicle benefits by removing the need for costly external chargers.
文摘This paper presents a novel inter-cluster direct current(DC)capacitor voltage balancing control scheme for the single-star configured modular multilevel cascaded converter(MMCC)-based static synchronous compensator(STATCOM)under unbalanced grid voltage.The negative-sequence component of grid voltage at the point of common connection(PCC)causes unbalanced active power flow in the phase limbs of converter.This leads to the imbalance of DC voltages of the sub-module capacitors across the MMCC phases,and consequently,the malfunction of converter.The proposed solution is to inject both negative-sequence current(NSC)and zero-sequence voltage(ZSV)into the phase limbs of MMCC.A quantification factor Qf is used to achieve the sharing of inter-cluster active pow-er between the NSC and ZSV injection methods.Accurate determination of the quantification factor has been presented.In addition to maintaining the DC voltages of sub-module capacitor across the MMCC phases balanced,it also prevents the overcurrent and overvoltage of converter by injecting NSC and ZSV with the right proportion.The control scheme is validated on a 3.54 kV 1.2 MVA power system using MMCC-based STATCOM with 3-level bridge cells as sub-modules.The results show that the proposed scheme provides superior effectiveness in eliminating the voltage imbalance of DC capacitor in the phase limb while maintaining low voltage and current ratings.
基金Supported by the key program of National Natural Science Foundation of China under Grant 51490683.
文摘Multi-level converters have been used extensively in modern industry which calls for energy conversion with high-power and high-or medium-voltage.Because of its modularity and scalability,the multi-level converter with modular structure can be extended to different voltage levels and has a variety of forms in practical applications.It has attracted much attention from academia in the past decade,however,as a result of the numerous vulnerable power electronics sub-modules,significant challenges remain with regards to reliability.After summarizing the current research status of modular multilevel cascade converters,the main issues of reliability are reviewed in the paper.Firstly,the failure cases are thoroughly surveyed and classified,and the main failure causes are analyzed.Secondly,the reliability evaluation methods are reviewed and applied to the modular multilevel cascade converters.Thirdly,some promising measures to improve the reliability are presented and discussed,including parameter selection,redundancy design,fault-tolerant control and so on.Then,a complete reliability-oriented design procedure for the modular multilevel cascade converters is proposed.Finally,the challenges and opportunities to improve the reliability are concluded.