期刊文献+
共找到907篇文章
< 1 2 46 >
每页显示 20 50 100
Effectivity and safety of trifocal intraocular lenses and capsular tension rings implantation for cataract patients with axial high myopia
1
作者 Shan Hua Qiu-Xia Xie +1 位作者 Hu Wang Jing-Xiang Zhong 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第3期499-508,共10页
●AIM:To assess effectivity and safety of trifocal intraocular lenses(IOLs)and capsular tension rings in treating cataract patients with axial high myopia.●METHODS:A prospective nonrandomized controlled clinical tria... ●AIM:To assess effectivity and safety of trifocal intraocular lenses(IOLs)and capsular tension rings in treating cataract patients with axial high myopia.●METHODS:A prospective nonrandomized controlled clinical trial was conducted.Totally 98 eyes(74 patients)who underwent femtosecond laser-assisted cataract surgery(FLACS)with trifocal IOLs were enrolled in the study and followed up for 2y after surgery:46 eyes(33 patients)with capsular tension ring implantation in the long axial lengths(AL)group(26<AL<29 mm)and 52 eyes(41 patients)in the normal AL group(22<AL<24.5 mm).Postoperative outcomes about effectivity and safety,including the subjective and objective visual quality,and postoperative complications were assessed.●RESULTS:Uncorrected distance visual acuity at 5 m and uncorrected intermediate visual acuity at 60 and 80 cm in the long AL group were significantly worse than those in the normal AL group at 3mo postoperatively(P<0.05).The differences in reading speed,spectacle independence and potential visual complaints between the two groups were not statistically significant(P>0.05).The dysfunctional lens index and total modulation transfer function(MTF)average height were similar between the two groups.The postoperative internal coma aberrations in the axial high myopia eyes were significantly higher than that in the normal AL group(P<0.05).The total satisfaction score in the long AL group(91.32±2.76)was slightly higher than that in the normal AL group(90.36±3.47),but there was no difference(P=0.136).A statistically negative correlation was found between corrected distance visual acuity(CDVA)and dysfunctional lens index(r=-0.382,P=0.009),and between CDVA and the total MTF average height(r=-0.374,P=0.01).But there was no significant correlation between CDVA and total satisfaction score(r=0.059,P=0.696).Postoperative complications mainly presented as posterior capsular opacity(PCO),retinal detachment and cystoid macular edema.There was no difference in the incidence of fundus disease(6.5%vs 3.8%,P=0.663)or PCO(17.4%vs 7.7%,P=0.217)between the two groups at two years.●CONCLUSION:The utilization of trifocal IOL and capsular tension ring implantation is beneficial for cataract patients with axial high myopia undergoing FLACS.This approach not only ensures excellent subjective feelings and objective visual quality,but also does not increase the incidence of postoperative complications. 展开更多
关键词 trifocal intraocular lenses capsular tension ring axial high myopia cataract visual quality
下载PDF
Considerations in the management of single-piece intraocular lenses outside the capsular bag
2
作者 Anna K Junk 《World Journal of Ophthalmology》 2014年第3期87-91,共5页
AIM: To investigate the outcomes of off label singlepiece acrylic intraocular lenses(SPA-IOL) ciliary sulcus placement compared to three-piece IOL(3P-IOL). METHODS: The charts of eight consecutive eyes of patients who... AIM: To investigate the outcomes of off label singlepiece acrylic intraocular lenses(SPA-IOL) ciliary sulcus placement compared to three-piece IOL(3P-IOL). METHODS: The charts of eight consecutive eyes of patients who received sulcus-placed SPA-IOLs between 2006 and 2009 were reviewed. None of the patients underwent IOL exchange. Charts of six age-matched patients who received sulcus placed 3P-IOLs were reviewed as a control group. RESULTS: Mean follow up was 16 mo for SPA-IOL and 23 mo for 3P-IOL. Five of 8 patients in the SPA-IOL group required chronic use of IOP lowering medications at final follow up. Of these, one patient needed glaucoma implant surgery for uncontrolled IOP. One patient in the 3P-IOL group used chronic aqueous suppression pre- and postoperatively. Four of eight eyes with SPAIOL were treated with chronic topical steroids and or non-steroidal anti-inflammatory drugs for cystoid macu-la edema, chronic uveitis, pigment dispersion syndrome or a combination of the above, compared to none in the control group. Mean best-corrected visual acuity was 20/35 in the SPA-IOL group and 20/47 in the 3PIOL group.CONCLUSION: Sulcus placed SPA-IOLs are associated with increased ocular morbidity. In select cases good visual acuity may be achieved. Due to postoperative rotation of sulcus placed toric SPA-IOLs stable astigmatism correction cannot be achieved. Alternative intraocular lenses should be considered when in-the-bag placement of SPA-IOL is not possible. 展开更多
关键词 cataract surgery Sulcus intraocular lens implant Single piece intraocular lenses Three piece intraocular lenses Posterior capsule tear cataract surgery complication Pigment dispersion Cystoid macula edema Anterior vitrectomy
下载PDF
Rotational stability of plate haptic toric intraocular lenses after combined 25-gauge vitrectomy and cataract surgery 被引量:1
3
作者 Lara Buhl Julian Langer +3 位作者 Stefan Kassumeh Thomas C.Kreutzer Wolfgang J.Mayer Siegfried G.Priglinger 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第8期1231-1236,共6页
AIM:To evaluate the postoperative intraocular lens(IOL)rotational stability and residual refractive astigmatism following combined 25-gauge vitrectomy and cataract surgery with implantation of a plate haptic toric IOL... AIM:To evaluate the postoperative intraocular lens(IOL)rotational stability and residual refractive astigmatism following combined 25-gauge vitrectomy and cataract surgery with implantation of a plate haptic toric IOL.METHODS:In this retrospective case series,32 eyes of 32 patients underwent a combined 25-gauge vitrectomy and phacoemulsification for vitreoretinal diseases and cataract with regular corneal astigmatism of at least 1 diopter(D).A plate haptic toric IOL(AT Torbi 709M,Carl Zeiss Meditec AG)was implanted in all eyes.The outcome measures were rotational stability and refractive astigmatism up to 6mo postoperatively as well as the best corrected visual acuity(BCVA).RESULTS:Preoperative refractive astigmatism was 2.14±1.17 D,which was significantly reduced to 0.77±0.37 D six to eight weeks postoperatively and remained stable throughout the observation period(0.67±0.44 D at three months and 0.75±0.25 D at six months;for all groups:P<0.0001 compared to baseline).BCVA improved significantly from 0.36±0.33 logMAR preoperatively to 0.10±0.15 logMAR following surgery(P=0.02).Mean IOL axis deviation from the target axis was 3.4°±2.9°after six to eight weeks and significantly decreased over time(2.4°±2.6°six months after surgery;P=0.04).In one patient IOL,re-alignment was performed.CONCLUSION:Corneal astigmatism is significantly reduced following combined 25-gauge vitrectomy and cataract surgery.The plate haptic toric IOL position and axis remain stable during the observation period of six months. 展开更多
关键词 combined phaco-vitrectomy toric intraocular lens rotational stability corneal astigmatism cataract vitreoretinal disease
下载PDF
Multifocal and extended depth of focus intraocular lenses
4
作者 Georgios Kondylis Olga Klavdianou Sotiria Palioura 《Annals of Eye Science》 2019年第1期13-18,共6页
Advances in intraocular lens(IOL)design have rendered cataract surgery a refractive procedure.Newer IOL types include bifocal,trifocal and extended depth of focus(EDOF)IOLs.Their basic difference nestles in the number... Advances in intraocular lens(IOL)design have rendered cataract surgery a refractive procedure.Newer IOL types include bifocal,trifocal and extended depth of focus(EDOF)IOLs.Their basic difference nestles in the number of focal points that each lens provides,which in turn leads to different visual outcomes.Familiarity of surgeons with the various characteristics of each lens is of utmost importance for accurate IOL selection to match each patient’s needs.In this review,we aim to compare the clinical outcomes after implantation of multifocal and EDOF IOLs in terms of distance,intermediate and near vision,contrast sensitivity,and reading performance.Finally,we discuss the defocus curve and the optical and photic phenomena associated with each type of IOL. 展开更多
关键词 cataract surgery quality of vision intraocular lens implantation trifocal intraocular lens bifocal intraocular lens
下载PDF
Distance vision after bilateral implantation of AcrySof toric intraocular lenses:a randomized,controlled,prospective trial 被引量:4
5
作者 Jin-Song Zhang Jiang-Yue Zhao +1 位作者 Qi Sun and Li-Wei Ma 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2011年第2期175-178,共4页
·AIM:To evaluate the distance vision of Chinese patients with cataracts and corneal astigmatism after implantation of bilateral AcrySof toric intraocular lens (IOL) versus bilateral AcrySof spherical IOL.·ME... ·AIM:To evaluate the distance vision of Chinese patients with cataracts and corneal astigmatism after implantation of bilateral AcrySof toric intraocular lens (IOL) versus bilateral AcrySof spherical IOL.·METHODS:This study randomized 60 patients into equal groups to receive toric IOL or spherical IOL.IOL powers targeting emmetropia were selected for 93% of toric IOL patients and for 90% of spherical IOL patients.Assessments included monocular and binocular distance vision,with and without best correction.Patients also completed surveys about their distance vision.·RESULTS:Preoperatively,the two study groups were similar in age,in distance visual acuity,and in the magnitude of corneal astigmatism.At 6 months postoperative,binocular uncorrected distance vision was 0.06?à0.14 logMAR in the AcrySof toric IOL group,significantly better than the 0.14?à0.11 logMAR in the spherical IOL group (P<0.05).For eyes with emmetropia as a target,the equivalent of 20/20 uncorrected vision was more likely (P<0.001) in the toric IOL group (36% of eyes) than in the spherical IOL group (4% of eyes).No patients in the emmetropia/toric IOL group used distance glasses,as compared to 52% of patients in the emmetropia/spherical IOL group.All patients were satisfied or highly satisfied.Quality of distance vision was rated higher by toric IOL patients than by spherical IOL patients (P<0.05).·CONCLUSION:Bilateral AcrySof toric IOL is superior to bilateral spherical IOL in providing uncorrected distance vision to cataract patients with corneal astigmatism.· 展开更多
关键词 ASTIGMATISM cataract extraction lenses intraocular PSEUDOPHAKIA
下载PDF
Higher order aberration comparison between two aspherical intraocular lenses: MC6125AS and Akreos advanced optics 被引量:5
6
作者 Mohammad Taher Rajabi Sara Korouji +4 位作者 Mahgol Farjadnia Mohammad Naderan Mohammad Bagher Rajabi Bahram Khosravi Seyed Mehdi Tabatabaie 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2015年第3期565-568,共4页
AIM: To compare higher order aberrations in two aspherical intraocular lenses(IOLs): Akreos advanced optics(AO) and Dr. Schmidt Microcrystalline 6125 aspheric anterior surface(MC6125AS) with each other. METHODS: Forty... AIM: To compare higher order aberrations in two aspherical intraocular lenses(IOLs): Akreos advanced optics(AO) and Dr. Schmidt Microcrystalline 6125 aspheric anterior surface(MC6125AS) with each other. METHODS: Forty eyes of 39 patients underwent phacoemulsification and Akreos AO and MC6125 AS were implanted in their eyes in a random manner. Three months post-operatively, higher order aberrations including spherical aberration, coma aberration, and total aberrations were measured and compared.RESULTS: The total aberration was 0.24±0.17 in eyes with Dr. Schmidt and 0.20 ±0.01 in eyes with Akreos AO(P =0.361). The mean of coma aberration was 0.17 ±0.21 and 0.09 ±0.86 in Dr. Schmidt and Akreos lenses,respectively(P =0.825). Total spherical aberration was almost the same in both groups(mean: 0.05, P =0.933).Best corrected visual acuity in Akreos AO(0.10±0.68) and Dr. Schmidt(0.09±0.67) did not differ significantly(P =0.700). CONCLUSION: There is no statistically significant difference in the higher order aberrations between these two aspherical lenses. 展开更多
关键词 aspherical lenses higher order aberrations cataract intraocular lens
下载PDF
New two-point scleral-fixation technique for foldable intraocular lenses with four hollow haptics 被引量:3
7
作者 He-Ting Liu Zheng-Xuan Jiang Li-Ming Tao 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2016年第3期469-471,共3页
The study was to report a new two-point scleralfixation technique for foldable intraocular lenses with four haptics.Lenses were slid into the anterior chamber from a 2.8 mm corneal incision and fixed under two sclera ... The study was to report a new two-point scleralfixation technique for foldable intraocular lenses with four haptics.Lenses were slid into the anterior chamber from a 2.8 mm corneal incision and fixed under two sclera flaps at two opposite points.The postoperative best-corrected visual acuities(BCVAs) of all patients were significantly better than their preoperative BCVA.The results demonstrate that two-point,scleral fixations of foldable,intraocular lenses might be practicable and effective. 展开更多
关键词 cataract intraocular lens APHAKIA scleral fixation
下载PDF
Analysis of glistenings in hydrophobic acrylic intraocular lenses on visual performance 被引量:2
8
作者 Lei Xi Yi Liu +2 位作者 Feng Zhao Chuan Chen Bing Cheng 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2014年第3期446-451,共6页
AIM:To assess patients’ visual performance with glistenings in one piece soft hydrophobic acrylic intraocular lenses(IOLs)(Alcon)2y postoperatively.METHODS:This cross section trial included 120 eyes with one piece IO... AIM:To assess patients’ visual performance with glistenings in one piece soft hydrophobic acrylic intraocular lenses(IOLs)(Alcon)2y postoperatively.METHODS:This cross section trial included 120 eyes with one piece IOL at 2y postoperatively.Glistening was classified in 4 groups,ranging from 0(none)to 3(most evident)according to their severity in IOLs optics observed under a slit lamp.All eyes underwent a uncorrected and best-corrected visual acuity evaluation(UCVA and BCVA,LogMAR scale),a complete clinical examination,a contrast sensitivity(CS)evaluation by F.A.C.T chart,and a visual field test by Humphrey Field AnalyzerⅡ(HFA).One-way ANOVA was used for quantitative data,while Pearsonχ2test was used for qualitative data to analyze the visual function of 4glistening groups.RESULTS:Totally 120 eyes were enrolled with 30 eyes in each glistening group.There was no statistical correlation between glistening grades and patients’age,IOLs power,postoperative UCVA and BCVA(P】0.05).Quantificationally,CS values among each group were not statistically different.However,qualitative analysis showed there were more eyes in grade 3 group than in grade 0 group having abnormally declined CS at high spatial frequency(10%vs 36.7%at 18 cpd,P=0.029;6.7%vs 26.7%at 12 cpd,P=0.013).Mean deviation(MD)of the visual field test was-2.14±2.31,-1.97±2.23,-3.02±3.17,-4.12±3.38 in group 0 to 3 respectively.There was a significant decrease in the most serious glistenings group(P=0.018).CONCLUSION:Glistenings may potentially have an impact on contrast sensitivity at high spatial frequency and MD in visual field test. 展开更多
关键词 cataract intraocular lens hydrophobic acrylic contrast sensitivity mean deviation
下载PDF
The Relation of the Location of Haptics of Posterior Chamber Intraocular Lenses and Peripheral Anterior Synechia 被引量:1
9
作者 RuiduanLiao ShaozhenLi 《眼科学报》 1995年第1期37-40,共4页
Purpose:To investigate the occurrence,outcome and influencial factors of the pe-ripheral anterior synechia(PAS)following implantation of posterior chamber in-traocular lenses for finding a way to reduce thePAS.Subject... Purpose:To investigate the occurrence,outcome and influencial factors of the pe-ripheral anterior synechia(PAS)following implantation of posterior chamber in-traocular lenses for finding a way to reduce thePAS.Subjects;40 eyes of 38senile cataract patients with normal chamber angle and in-traocular pressue(IOP)preoperatively were examined.Methods:Extracapsular cataract extraction was performed under microscope with insertion of a posterior chamber lens implant vaulted anteriorly by 10°.Go-nioscopy and slit-lamp examination and photography of the operated eyes were performed 3to 6months postoperatively.Results:PAS were found in 20(50%)of the 40eyes.Among the 20eyes with PAS the locations of 23haptics in17eyes corresponded with those of the PAS.PAS were seen more frequently with vertically sulcus-fixated haptics than with the horizontally capsular-fixated haptics.showing a significant difference(P<0.05).88%of the eyes withPAS had pupillary edformation,but their visual acuities and IOP were not affected.Conclusions:PAS is more likely to occur with vertically sulcus-fixated IOL.Rotat-ing the capsular-fixated haptics to the horizontal position may reduce the inci-dence of PAS.Gonioscopy should be a routine follow-up examination. 展开更多
关键词 白内障摘除术 后囊晶体 前房虹膜 粘连 并发症 临床研究
下载PDF
A Clinical Analysis of 120 Cases with Traumatic Cataract Treated by Extracapsular Cataract Extraction and Posterior Chamber Intraocular Lens Implantation
10
作者 汤崇凯 马赛芬 《The Journal of Biomedical Research》 CAS 1998年第1期44-46,共3页
Extracapsular cataract extraction was performed combined with posterior chamber intraocular lens implantation on 120 inpatients (122 eyes) with traumatic cataract from 1992 to 1997. The results revealed that this comb... Extracapsular cataract extraction was performed combined with posterior chamber intraocular lens implantation on 120 inpatients (122 eyes) with traumatic cataract from 1992 to 1997. The results revealed that this combined operation can make most of them get useful visual acuity, although they were often accompanied with several comlicated eye injuries. We think the most important thing is to choose suitable opertion time, the reasonable operation method and take close followup after operation. 展开更多
关键词 traumatic cataract extracapsular cataract extraction (ECCE) posterior chamber intraocular lens(PCIOL) implantation combined operation
下载PDF
Trifocal toric intraocular lenses in eyes with low amount of corneal astigmatism
11
作者 Paz Orts-Vila Salvador Aguilar-Corcoles +3 位作者 Cristina Tello-Elordi María Ramos-Alzamora Robert Montés-Mico Pedro Taná-Rivero 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2020年第10期1567-1573,共7页
AIM:To evaluate the refractive and visual outcomes following cataract surgery and implantation of a trifocal toric intraocular lens(IOL)in eyes with low degrees of corneal astigmatism.METHODS:Twenty-six eyes of 22 pat... AIM:To evaluate the refractive and visual outcomes following cataract surgery and implantation of a trifocal toric intraocular lens(IOL)in eyes with low degrees of corneal astigmatism.METHODS:Twenty-six eyes of 22 patients who underwent implantation a trifocal toric IOL(FineVision PODFT,PhysIOL s.a.,Liege,Belgium)were enrolled.Phacoemulsification with femtosecond laser,capsular tension ring insertion and intraoperative aberrometry were performed in all cases.All IOLs used showed a cylinder power of 1.00 D.Main outcome measures were refractive error and corrected-distance visual acuity(CDVA)and uncorrected-distance visual acuity(UDVA)values.Eyes were evaluated at 4 mo post-surgery.RESULTS:Totally 50%of eyes showed a spherical equivalent(SE)within±0.13 D and all of them within±0.50 D.The mean SE and refractive cylinder were-0.02±0.23 and-0.16±0.22 D,respectively.Vector analysis revealed that 100%of eyes were within±0.50 D for the SE and cylindrical components(J0 and J45).Refractive changes were not correlated with keratometric changes(P>0.05)showing that the reduction in astigmatism comes from the trifocal toric IOL.Of 81%and 96%of eyes showed UDVA and CDVA of 20/20,respectively.The postoperative mean values of monocular distance Snellen decimal UDVA and CDVA were 0.97±0.05 and 0.99±0.02(about 20/20),respectively.CONCLUSION:Our study suggests that the use of this trifocal toric IOL in patients with low amount of astigmatism provides accurate refractive outcomes and enables them to achieve excellent visual acuity. 展开更多
关键词 TORIC trifocal intraocular lens PHACOEMULSIFICATION cataract ASTIGMATISM
下载PDF
Modeling monocular form deprivation in rabbits using a simulated-cataract intraocular lens
12
作者 Si-Yi Gu Li-Ming Xu +9 位作者 Wei-Jie Sun Li-Li Liang Lei Lin Han Zou Jing-Yuan Xu Yu Zheng Yuan-Yuan Li Yin-Ying Zhao Ping-Jun Chang Yun-E Zhao 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第12期2177-2184,共8页
AIM:To establish an animal model of form deprivation amblyopia based on a simulated cataract intraocular lens(IOLs).METHODS:Poly(dimethyl siloxane)-SiO_(2) thin films(PSF)with different degrees of opacity as IOL mater... AIM:To establish an animal model of form deprivation amblyopia based on a simulated cataract intraocular lens(IOLs).METHODS:Poly(dimethyl siloxane)-SiO_(2) thin films(PSF)with different degrees of opacity as IOL materials were prepared.The light transmission of the PSF-IOL was measured,and its in vitro biosafety was determined by cell counting kit(CCK)-8 assay using the HLEC-B3 cell line and ARPE-19 cell line.Subsequently,the in vivo safety was determined by implanting the PSF-IOL with 10%wt SiO_(2) into the right eyes of New Zealand white rabbits(PSF-IOL group),and compared with two control groups:contralateral comparison group and normal control(NC)group(Contralateral comparison group:the fellow eye;NC group:a group of binocular normal rabbits without intervention).The flash visual-evoked potentials(F-VEPs)were measured to verify amblyopia.RESULTS:PSFs containing 0,2%,and 10%wt SiO_(2) were successfully constructed.The 0 SiO_(2) PSF was transparent,while the 10%wt SiO_(2) PSF was completely opaque.It was found that PSF did not induce unwanted cytotoxicity in HLECs and ARPE19 cells in vitro.In vitro,PSF-IOL with 10%wt SiO_(2) was also non-toxic,and no significant inflammation or structural changes occurred after four weeks of PSF-IOL implantation.Finally,our IOL-simulated congenital cataract rabbit detected by F-VEPs suggested tentative amblyopia.CONCLUSION:A PSF-IOL that mimics cataracts is created.A novel form deprivation model is created by the IOL-simulated congenital cataract rabbit.It can be developed fast and stable and holds great potential for future study. 展开更多
关键词 monocular deprivation form deprivation intraocular lens congenital cataract AMBLYOPIA
下载PDF
Comparison of trifocal toric and bifocal toric intraocular lens implantation in patients with cataract and high corneal astigmatism 被引量:2
13
作者 Merve Bozkurt Gencer Hikmet Basmak +1 位作者 Erdogan Yasar Ozkan Onal 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2021年第12期1876-1881,共6页
AIM:To investigate and compare the quality of life,satisfaction,contrast sensitivity,glare,depth perception,and intraocular lens(IOL)rotation in patients who underwent trifocal toric and bifocal toric IOLs.METHODS:A t... AIM:To investigate and compare the quality of life,satisfaction,contrast sensitivity,glare,depth perception,and intraocular lens(IOL)rotation in patients who underwent trifocal toric and bifocal toric IOLs.METHODS:A total of 80 eyes of 40 patients were included in this prospective study.Twenty patients in each group were implanted with trifocal toric and bifocal toric IOL,respectively.Preoperative and postoperative 6-month measurements were recorded for both patient groups.Comprehensive anterior and posterior segment examinations,distance-intermediate-near visual acuity values and the visual function scale questionnaire results were evaluated at these examinations.Patient satisfaction,contrast sensitivity,glare,intermediate-near and distance stereopsis and IOL rotation were also evaluated.RESULTS:No significant difference was found between the groups in terms of distance and near visual acuities(P=0.269,P=0.451).Intermediate visual acuity was significantly increased in the trifocal toric group(P<0.001).The visual function scale results were increased after surgery in both groups(P=0.001 and P<0.001),with no difference determined between them(P=0.158 and P=0.691).The number of patients wearing glasses was low in both groups and there was no significant difference between the groups(P>0.05).The overall satisfaction in the trifocal toric group was significantly higher than in the bifocal toric group(P=0.03).The highest sensitivity was observed at 6 cpd spatial frequency in all patients under photopic conditions(1.80±0.24 logU,1.74±0.20 logU).Distance-intermediate-near binocular depth perception results in both groups were higher in the trifocal toric group(P=0.02,0.048,0.003,respectively).Although there was no significant difference for 3 meters stereopsis,the trifocal toric group had higher depth perception(P=0.577).Mean rotation was 5.76°±3.93°in the trifocal toric group and 12°±7.1°in the bifocal toric group.CONCLUSION:Better results in the middle distance are obtained in the trifocal toric group and less IOL rotation due to digital system-coordinated surgery.Moreover,the overall satisfaction in the trifocal toric group is significantly higher than in the bifocal toric group. 展开更多
关键词 cataract trifocal toric intraocular lens bifocal toric intraocular lens STEREOPSIS SATISFACTION
下载PDF
Severe prelenticular membrane formation on the surface of a hydrophilic acrylic intraocular lens after cataract surgery in an eye with an Ahmed valve implant 被引量:1
14
作者 Yong-Sun Ahn Jin A Choi 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2015年第2期430-432,共3页
【正】Dear Sir,Iam Yong-Sun Ahn,from the Department of Ophthalmology of St.Vincent Hospital of Suwon,Kyungki-do,South Korea.Cataracts are a common problem in eyes with a glaucoma drainage device(GDD),because tube shun... 【正】Dear Sir,Iam Yong-Sun Ahn,from the Department of Ophthalmology of St.Vincent Hospital of Suwon,Kyungki-do,South Korea.Cataracts are a common problem in eyes with a glaucoma drainage device(GDD),because tube shunt surgery increases the incidence and progression of cataracts[1].An Ahmed valve,the most commonly inserted GDD,is composed of a silicone tube connected to a flat plate sewn to the sclera,and aqueous humor flows from the 展开更多
关键词 IOL Severe prelenticular membrane formation on the surface of a hydrophilic acrylic intraocular lens after cataract surgery in an eye with an Ahmed valve implant body Figure
下载PDF
Bimanual microincision cataract surgery with implantation of the new Incise~? MJ14 intraocular lens through a 1.4 mm incision 被引量:2
15
作者 Gian Maria Cavallini Tommaso Verdina +5 位作者 Michele De Maria Elisa Fornasari Giulio Torlai Veronica Volante Simone Donati Carlo Cagini 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第11期1710-1715,共6页
AIM:To analyze the visual outcomes and the posterior capsule opacification(PCO)with the new Incise?MJ14intraocular lens(IOL)implanted through a 1.4 mm clear corneal incision(CCI)in patients who underwent biman... AIM:To analyze the visual outcomes and the posterior capsule opacification(PCO)with the new Incise?MJ14intraocular lens(IOL)implanted through a 1.4 mm clear corneal incision(CCI)in patients who underwent bimanual microincision cataract surgery(B-MICS).METHODS:Eighty eyes which underwent cataract surgery using B-MICS technique performed by the same experienced surgeon were included in the study:40 eyes were implanted with an Incise?MJ14 IOL through a 1.4 mm CCI(group A)without enlargement of the main CCI,while 40 eyes were implanted with an Akreos?MI60 IOL with enlargement of the main CCI to 1.8 mm(group B).Best corrected visual acuity(BCVA),astigmatism and endothelial cell loss were evaluated before and after surgery at 7,30d and 6mo.Anterior segment-optical coherence tomography(AS-OCT)of CCI was performed at 1,3,7,30d,6 and 18mo.PCO incidence was evaluated at 18mo using EPCO 2000 Software.RESULTS:Mean BCVA improvement and endothelial cell loss were statistically significant at 18mo in both groups with no difference between the two groups;no statistically significant difference in surgically induced astigmatism(SIA)was noticed in the two groups.At AS-OCT the only significant alterations in the CCI were endothelial gaping and local detachment of Descemet’s membrane at 1 and 7d after surgery;no statistically significant alterations were found at 1,6 and 18mo.PCO score at 18mo was 0.03±0.07for group A and 0.08±0.18 for group B(P=0.11)with no sign of central optic plate invasion in both groups.CONCLUSION:The implant of the new Incise?MJ14 IOL through a 1.4 mm CCI and B-MICS technique appeared to be a safe and effective procedure with rapid visual recovery.PCO rate resulted very low and the CCI presented few morphological alterations which were only detectable in the first days postoperatively and achieved fast corneal healing during the long-term follow-up. 展开更多
关键词 CCI In De Bimanual microincision cataract surgery with implantation of the new Incise MJ14 intraocular lens through a 1.4 mm incision
下载PDF
Correction of extreme hyperopia: artisan iris-fixated intraocular lens implantation for pseudophakia after clear lens extraction
16
作者 Wen Xu Pan-Pan Ye +4 位作者 Ke Yao Zhao-Chun Li Feng-Ying He Jun-Ting Shi and Jun Liu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2011年第4期454-457,共4页
A 22-year-old patient suffering from both-side extreme hyperopia with amblyopia was corrected with an Artisan iris-fixated intraocular lens (IOL) implantation followed to clear lens extraction (CLE) with posterior cha... A 22-year-old patient suffering from both-side extreme hyperopia with amblyopia was corrected with an Artisan iris-fixated intraocular lens (IOL) implantation followed to clear lens extraction (CLE) with posterior chamber (PC)-IOL implantation. The preoperative refraction values were +17.75DS -1.50DC × 168° for the right eye and +17.25DS -0.75DC × 8° for the left eye. The uncorrected visual acuity (UCVA) was 20/200 bilaterally and the spectacle-corrected visual acuity (BSCVA) was 20/50 bilaterally. One year after Artisan iris-fixated IOL implantation, bilateral BSCVA was 20/50 with a refraction of +1.25DS -0.75DC × 13° for the right eye and +1.50DS -1.00DC × 55° for the left eye. The outcomes of an Artisan iris-fixated IOL implantation followed to CLE with PC-IOL implantation were encouraging for the correction of extreme hyperopia. Long term follow-up examinations were necessary for further determination of the efficacy and safety of this combinational procedure. 展开更多
关键词 HYPEROPIA clear lens extraction iris-fixated intraocular lens
下载PDF
Case report:simultaneous femtosecond laser astigmatic keratotomy and toric intraocular lens implantation in femtosecond laser-assisted cataract surgery in a patient with surgically induced high corneal astigmatism
17
作者 Yan Guo Heather Edwards +2 位作者 Mark Woodward Tyrone Curtis Gresham Kayla Morgan 《Annals of Eye Science》 2022年第4期69-76,共8页
Background:Femtosecond laser astigmatic keratotomy(FSAK)and toric intraocular lens(IOL)implantation have been studied individually for comparison to treat astigmatism at cataract surgery.We report a case of surgically... Background:Femtosecond laser astigmatic keratotomy(FSAK)and toric intraocular lens(IOL)implantation have been studied individually for comparison to treat astigmatism at cataract surgery.We report a case of surgically induced high corneal astigmatism by laser thermal keratoplasty(LTK)in a patient with cataract who was successfully treated with simultaneous combination of FSAK and toric IOL implantation with femtosecond laser-assisted cataract surgery(FLACS).This is the first report of both procedures combined simultaneously,with or without history of LTK.Case Description:A 68-year-old male presented with a history of LTK with two enhancements each eye in 2004,with subsequent surgically induced high corneal astigmatism,and with age-related nuclear cataract of both eyes.IOL master demonstrated+7.71 diopters of astigmatism at 163 degree right eye and+3.29 diopters of astigmatism at 4 degree left eye.After extensive discussion of the risks and benefits,the patient agreed to undergo FLACS with FSAK with two 61 degrees of relaxation incisions(RIs)and toric IOL(Alcon SN6AT9)right eye;FLACS with toric IOL(Alcon SN6AT7)alone left eye.At 2-year follow-up,uncorrected visual acuity was 20/30 right eye,20/25 left eye.His best corrected visual acuity was 20/25(+0.25+1.00 axis 21)right eye and 20/20(plano+0.25 axis 90)left eye;his best corrected near visual acuity was J1+with add+2.50 diopters right eye and left eye.Conclusions:Patients with age-related cataract and LTK induced high corneal astigmatism can hardly be sufficiently treated with FSAK or toric IOL alone at the time of cataract surgery.An effective way is to combine large FSAK and toric IOL of the highest cylindrical power of T9,in our case,simultaneously,which can achieve an excellent long term visual outcome. 展开更多
关键词 High corneal astigmatism[induced by laser thermal keratoplasty(LTK)] femtosecond laser astigmatic keratotomy(FSAK) toric intraocular lens implantation(IOL implantation) femtosecond laser-assisted cataract surgery(FLACS) case report
下载PDF
High order aberration and straylight evaluation after cataract surgery with implantation of an aspheric,aberration correcting monofocal intraocular lens 被引量:14
18
作者 Florian T A Kretz Tamer Tandogan +1 位作者 Ramin Khoramnia Gerd U Auffarth 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2015年第4期736-741,共6页
·AIM: To evaluate the quality of vision in respect to high order aberrations and straylight perception after implantation of an aspheric, aberration correcting,monofocal intraocular lens(IOL).·METHODS: Twent... ·AIM: To evaluate the quality of vision in respect to high order aberrations and straylight perception after implantation of an aspheric, aberration correcting,monofocal intraocular lens(IOL).·METHODS: Twenty-one patients(34 eyes) aged 50 to83 y underwent cataract surgery with implantation of an aspheric, aberration correcting IOL(Tecnis ZCB00,Abbott Medical Optics). Three months after surgery they were examined for uncorrected(UDVA) and corrected distance visual acuity(CDVA), contrast sensitivity(CS)under photopic and mesopic conditions with and without glare source, ocular high order aberrations(HOA, Zywave II) and retinal straylight(C-Quant).· RESULTS: Postoperatively, patients achieved a postoperative CDVA of 0.0 log MAR or better in 97.1% of eyes. Mean values of high order abberations were +0.02±0.27(primary coma components) and-0.04 ±0.16(spherical aberration term). Straylight values of the C-Quant were 1.35±0.44 log which is within normal range of age matched phakic patients. The CS measurements under mesopic and photopic conditions in combination with and without glare did not show any statistical significance in the patient group observed(P ≥0.28).· CONCLUSION: The implantation of an aspherical aberration correcting monofocal IOL after cataractsurgery resulted in very low residual higher order aberration(HOA) and normal straylight. 展开更多
关键词 cataract ABERRATIONS intraocular lens
下载PDF
AN EXPERIMENTAL STUDY OF THE TUMOUR NECROSIS FACTOR LEVELSIN AQUEOUS HUMOR AFTER TRAUMATIC CATARACT AND INTRAOCULAR LENS IMPLANTATION 被引量:2
19
作者 周朝晖 何守志 《Chinese Medical Sciences Journal》 CAS CSCD 1999年第1期64-66,共3页
Purpose. This paper studies the tumour necrosis factor (TNF) levels in aqueous humor after traumatic cataract extraction and posterior chamber (PC) intraocular lens (IOL) implantation in rabb... Purpose. This paper studies the tumour necrosis factor (TNF) levels in aqueous humor after traumatic cataract extraction and posterior chamber (PC) intraocular lens (IOL) implantation in rabbits,and discusses the effect of TNF on postoperative anterior ocular inflammation. Methods. Twenty seven pigmented rabbits were divided into three groups: for the first group, the IOL were placed in the capsular bag after traumatic cataract extraction; for the second, the Extracapsular cataract extraction without IOL implantation; and for the third, the control group without surgical intervention. On the 1st, 3rd, 7th and 14th day postoperatively, aqueous humor samples were obtained. A modified double antibodies indirect sandwich ELISA was used to detected for the presence of TNF. The data were studied by means of analysis of variance in SAS software. Result. The TNF level was increased in aqueous humor and reached its maximum on the 1st postoperative days after traumatic cataract extraction and PC IOLs implantation, and the TNF levels are significantly higher (P<0 05) on the 1st, 3rd, 7th and 14th day postoperatively in traumatic cataract extraction and PC IOL implanted group than that in the non surgical intervention group and extracapsular cataract extraction group. Conclusions. The increase of TNF levels had a close relationship with presence of the IOL itself which induces the secretion of TNF. This suggested that TNF as the principal mediators of immunological and inflammatory responses, so that may play critical role in anterior ocular inflammative response after traumatic cataract extraction and IOL implantation. 展开更多
关键词 intraocular lens traumatic cataract extraction tumour necrosis factor (TNF)
下载PDF
Evaluating newer generation intraocular lens calculation formulas in manual versus femtosecond laser-assisted cataract surgery 被引量:2
20
作者 Harrish Nithianandan Soumya Sharma +3 位作者 Eric S.Tam Hannah Chiu Rajiv Maini Sohel Somani 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2021年第8期1174-1178,共5页
AIM:To determine the refractive accuracy of the Haigis,Barrett Universal II(Barrett),and Hill-radial basis function 2.0(Hill-RBF)intraocular lens(IOL)power calculations formulas in eyes undergoing manual cataract surg... AIM:To determine the refractive accuracy of the Haigis,Barrett Universal II(Barrett),and Hill-radial basis function 2.0(Hill-RBF)intraocular lens(IOL)power calculations formulas in eyes undergoing manual cataract surgery(MCS)and refractive femtosecond laser-assisted cataract surgery(Re LACS).METHODS:This was a REB-approved,retrospective interventional comparative case series of 158 eyes of 158 patients who had preoperative biometry completed using the IOL Master 700 and underwent implantation of a Tecnis IOL following uncomplicated cataract surgery using either MCS or ReLACS.Target spherical equivalence(SE)was predicted using the Haigis,Barrett,and Hill-RBF formulas.An older generation formula(Hoffer Q)was included in the analysis.Mean refractive error(ME)was calculated one month postoperatively.The lens factors of all formulas were retrospectively optimized to set the ME to 0 for each formula across all eyes.The median absolute errors(MedAE)and the proportion of eyes achieving an absolute error(AE)within 0.5 diopters(D)were compared between the two formulas among MCS and ReLACS eyes,respectively.RESULTS:Of the 158 eyes studied,64 eyes underwent MCS and 94 eyes underwent ReLACS.Among MCS eyes,the MedAE did not differ between the formulas(P=0.59),however among ReLACS eyes,Barrett and Hill-RBF were more accurate(P=0.001).Barrett and Hill-RBF were both more likely to yield AE<0.5 D among both groups(P<0.001).CONCLUSION:The Barrett and Hill-RBF formula lead to greater refractive accuracy and likelihood of refractive success when compare to Haigis in eyes undergoing Re LACS. 展开更多
关键词 PHACOEMULSIFICATION cataract femtosecond laser intraocular lens
下载PDF
上一页 1 2 46 下一页 到第
使用帮助 返回顶部