期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
A method for designing a variable-channel high-power cavity combiner
1
作者 刘勇涛 黄贵荣 +2 位作者 尚雷 林宏翔 杜百廷 《Chinese Physics C》 SCIE CAS CSCD 2016年第8期148-153,共6页
Cavity combiners have been put forward for high power combining due to their advantages of larger combining ability, variable input channels and less power loss. For a high power cavity combiner, it is better to keep ... Cavity combiners have been put forward for high power combining due to their advantages of larger combining ability, variable input channels and less power loss. For a high power cavity combiner, it is better to keep the power loss ratio in a reasonable range, because large power loss would lead to strict requirements on the cooling system. A combiner with variable input channels is convenient for outputting different power levels according to practical demands. In this paper, a method for designing a variable-channel high-power cavity combiner is proposed, based on the relation between input and output coupling coefficients obtained by analyzing the equivalent circuit of the cavity combiner. This method can put the designed cavity combiner in a matching state and keep its power loss rate in a reasonable range as the number of input channels changes. As an example, a cavity combiner with 500 MHz and variable input channels from 16 to 64 is designed, and the simulation results show that our proposed method is feasible. 展开更多
关键词 cavity combiner variable channels equivalent circuit coupling coefficient
原文传递
Optimization of Cavity Combination for 20 MA LTD-Based Accelerators 被引量:1
2
作者 呼义翔 邱爱慈 +7 位作者 曾正中 黄涛 孙凤举 王亮平 丛培天 曾江涛 张信军 雷天时 《Plasma Science and Technology》 SCIE EI CAS CSCD 2012年第10期927-931,共5页
Based on a transmission line code, a circuit model is proposed that could serve as the basic method for the analysis of linear transformer driver (LTD)-based accelerators. By using 1 MA, 100 kV LTD cavities, the pea... Based on a transmission line code, a circuit model is proposed that could serve as the basic method for the analysis of linear transformer driver (LTD)-based accelerators. By using 1 MA, 100 kV LTD cavities, the peak load current is optimized for a total of N cavities between 500 and 1200. The simulation results suggest that, with the same number of cavities, the peak current changes obviously with the types of combinations, and the maximum change can be as large as 1.2 MA. The results also show that, for the cases considered, the optimized peak current as a function of the total number of cavities agrees with the exponential associate, and the peak current for one level LTD cannot be enhanced infinitely. Furthermore, it is found that, to obtain a 20 MA peak load current, at least 1029 LTD cavities (49 in series and 21 in parallel connection) are needed. Finally, the typical parameters of the optimized design are compared to those of the existing Z accelerator. 展开更多
关键词 linear transformer driver (LTD) impedance transformer cavities combination dynamic inductance
下载PDF
Pressure distribution of combining center cavity slipper for axial piston pump
3
作者 王亚军 苑士华 《Journal of Beijing Institute of Technology》 EI CAS 2014年第4期452-456,共5页
In order to improve lubricating characteristics of slippers in an axial piston pump, the combining center cavity slipper approach was proposed based on slipper shape and moving characteristic. The cylindrical coordina... In order to improve lubricating characteristics of slippers in an axial piston pump, the combining center cavity slipper approach was proposed based on slipper shape and moving characteristic. The cylindrical coordinate was used in the lubricant area and mesh was made. The blockweight approach was implemented to deal with non-coincidence of mesh and shallow recess border in numerical method. The finite control volume method was applied in calculating pressure distribution. The flow conservation equation and film thickness model were resolved through Gauss-Siedel relaxation iteration. The calculation and analysis results indicate that compared to the slipper (1) slip- per pressure distribution is improved; (2) hydrodynamic pressure of the combining slipper is greatly increased; (3) inclining degree is greatly reduced; (4) negative pressure in lubricant film disappear. So the combining center cavity slipper is lubricated better. 展开更多
关键词 axial piston pump combining center cavity slipper finite control volume method pressure distribution
下载PDF
Diode-pumped tunable laser with dual Cr:LiSAF rods
4
作者 谢国强 王韬 +1 位作者 朱鹤元 钱列加 《Chinese Physics B》 SCIE EI CAS CSCD 2006年第3期547-551,共5页
We propose and demonstrate a simple approach to lower the thermal quenching effect and improve the output power of Cr:LiSAF lasers, which is accomplished by employing two laser rods. The resonator contains two laser ... We propose and demonstrate a simple approach to lower the thermal quenching effect and improve the output power of Cr:LiSAF lasers, which is accomplished by employing two laser rods. The resonator contains two laser rods and is designed by using two "X" folding cavities in cascade. A tunable laser output of ~ 180 mW has been achieved with the pump of single-striped laser diodes. Compared with lasers using single gain rod, the laser with dual rods shows less severe thermal effect and increases the output by more than two times. 展开更多
关键词 dual laser rods combined cavity tunable laser
下载PDF
Broad-area laser diodes with on-chip combined angled cavity 被引量:2
5
作者 卢泽丰 汪丽杰 +6 位作者 赵智德 舒世立 侯冠宇 陆寰宇 田思聪 佟存柱 王立军 《Chinese Optics Letters》 SCIE EI CAS CSCD 2017年第8期71-75,共5页
Semiconductor diode lasers are widely used in a variety of applications, such as pumping, telecommunication, laser display, industrial manufacturing, and medical treatments because of their high wall-plug efficiency,
关键词 LENGTH Broad-area laser diodes with on-chip combined angled cavity high BPP mode area
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部