A new strategy using an arnperometric biosensor with Escherichia coli (E. coli) that provides a rapid toxicity determination of chemical compounds is described. The CellSense biosensor system comprises a biological ...A new strategy using an arnperometric biosensor with Escherichia coli (E. coli) that provides a rapid toxicity determination of chemical compounds is described. The CellSense biosensor system comprises a biological component immobilized in intimate contact with a transducer which converts the biochemical signal into a quantifiable electrical signal. Toxicity assessment of heavy metals using E.coli biosensors could be finished within 30 min and the 50% effective concentrations (ECso) values of four heavy metals were determined. The results shows that inhibitory effects of four heavy metals to E.coli can be ranked in a decreasing order of Hg^2+ 〉 Cu^2+ 〉 Zn^2+ 〉 Ni^2+, which accords to the results of conventional bacterial counting method. The toxicity test of organic compounds by using CellSense biosensor was also demonstrated. The CellSense biosensor with E. coli shows a good, reproducible behavior and can be used for reproducible measurements.展开更多
The prediction and assessment of environmental pollution by arsenic are important preconditions of advocating environmental protection and human health risk assessment. A yellow fluorescent protein-based whole-cell bi...The prediction and assessment of environmental pollution by arsenic are important preconditions of advocating environmental protection and human health risk assessment. A yellow fluorescent protein-based whole-cell biosensor for the detection of arsenite and arsenate was constructed and tested. An arsenic-resistant promoter and the regulatory gene arsR were obtained by PCR from the genome ofEscherichia coli DH5ct, andphiYFP was introduced into E. coli DH5ct as a reporter gene to construct an arsenic-resistant whole-cell biosensor (WCB-11) in which phiYFP was expressed well for the first time. Experimental results demonstrated that the biosensor has a good response to arsenic and the expression ofphiYFP. When strain WCB-11 was exposed to As^3+ and As^5+, the expression of yellow fluorescence was time-dependent and dose-dependent. This engineered construct is expected to become established as an inexpensive and convenient method for the detection of arsenic in the field.展开更多
Detection of N-acyl homoserine lactones (AHLs) is useful for understanding quorum sensing (QS) behaviors, including biofilm formation, virulence and metabolism. For detecting AHLs and indicating the host cells in ...Detection of N-acyl homoserine lactones (AHLs) is useful for understanding quorum sensing (QS) behaviors, including biofilm formation, virulence and metabolism. For detecting AHLs and indicating the host cells in situ, we constructed the plasmid pUCGMA2T1-4 to make a dual fluorescent whole- cell biosensor based on the AhlI/R AHL system of Pseudomonas syringae pv. syringae B728a. The plasmid contains three components: constitutively expressed enptll::gfP for indicating host cells, Pahll::mcherry that produces red fluorescence in response to AHL, and the ahIR gene that encodes an AHL regulatory protein. Meanwhile, two copies of T1-4 (four tandem copies of a transcriptional terminator) were added into the plasmid to reduce background. The results showed that when the plasmid was placed into Escherichia coli, the dual fluorescence whole-cell biosensor was able to respond with red fluorescence within 6 hr to 5 × 10^-8-1 × 10^-5 mol/L of 3OC6-HSL. Bright green fluorescence indicated the host cells. Furthermore, when the plasmid was transferred to wild- type Pseudomonas PhTA125 (an AHL-producing bacterium), it also showed both green and red fluorescence. This result demonstrates that this plasmid can be used to construct whole-cell indicators that can indicate the AHL response and spatial behaviors of microbes in a mi tal niche展开更多
The light-addressable potentiometric sensor (LAPS) is a semiconductor-based cellular biosensor with an electrolyte-insulator-semiconductor (EIS) structure.By depositing biocompatible layers on the sensing surface fo...The light-addressable potentiometric sensor (LAPS) is a semiconductor-based cellular biosensor with an electrolyte-insulator-semiconductor (EIS) structure.By depositing biocompatible layers on the sensing surface for cell culture, it can be used to detect bioelectrical parameters of cells.The characteristic curve for photocurrent versus applied bias voltage to the system shows a current-voltage curve (Ⅰ-Ⅴcurve).This technique can be used to detect the action potential changes towards different drugs based on the bias voltage dependence of an optical current,and provides a dynamic system by scanning light beam at the very cell on the sensor device.The LAPS overcomes the limitation of recording sites,but high spatial resolution and sensitivity are also paramount.This paper discussed a novel structure of LAPS array for extracellular monitoring to decrease potential noise level.Both characteristics of active recording array areas and cell culture conditions are measured.展开更多
This paper reviews a novel cell-based biosensor and Bio-MEMS which incorporate living cells as sensing elements that convert a change in immediate environment to signals conducive for processing.It is characterized wi...This paper reviews a novel cell-based biosensor and Bio-MEMS which incorporate living cells as sensing elements that convert a change in immediate environment to signals conducive for processing.It is characterized with high sensitivity,excellent selectivity and fast response and have been implemented for a number of applications ranging from pharmaceutical screening to environmental pollutant detection.This paper also introduces our recent work about Light-Addressable Potentiometric Sensors (LAPS),Field Effect Transistor (FET),Micro-Electrode Array Sensors (MEAS) and Bio-MEMS for detecting the changes of concentration of extracellular ions and the action potential of living cell under effect of drugs and environmental parameters.Finely, the paper gives some prospects of cell-based biosensors in the future.展开更多
In this study, an enzymatic electrode for glucose biosensing and bioanode of glucose/air biofuel cell has been fabricated by immobilizing poly (methylene green) (polyMG) for electrocatalytic NADH oxidation and NAD+-de...In this study, an enzymatic electrode for glucose biosensing and bioanode of glucose/air biofuel cell has been fabricated by immobilizing poly (methylene green) (polyMG) for electrocatalytic NADH oxidation and NAD+-dependent glucose dehydrogenase (GDH) for oxidizing glucose on carbon nanodots (CNDs). The polyMG-CNDscomposites obtained by electro-polymerization of dye MG molecules adsorbed on CNDs display excellent electrocatalytic activity toward NADH electro-oxidation at a low overpotential of ca. -0.10 V (vs. Ag/AgCl) and the integrated enzymatic electrode shows fast response to glucose electrooxidation. Using the fabricated GDH-based enzymatic electrode, a glucose biosensor was constructed and exhibits a wide linear dynamic range from 0 to 8 mM, a low detection limit of 0.02 μM (S/N = 3), and fast response time (ca. 4 s) under the optimized conditions. The developed glucose biosensor was used to detect glucose content in human blood with satisfactory results. The fabricated GDH-based enzymatic electrode was also employed as bioanode to assembly a glucose/air biofuel cell with the laccase-CNDs/GC as the biocathode. The maximum power density delivered by the assembled glucose/air biofuel cell reaches 3.1 μW·cm-2 at a cell voltage of 0.22 V in real sample fruit juice. The present study demonstrates that potential applications of GDH-based CNDs electrode in analytical and biomedical measurements.展开更多
基金supported by the National Natural Science Foundation of China(No.20707014)the Program for Young Excellent Talents of Tongji University.
文摘A new strategy using an arnperometric biosensor with Escherichia coli (E. coli) that provides a rapid toxicity determination of chemical compounds is described. The CellSense biosensor system comprises a biological component immobilized in intimate contact with a transducer which converts the biochemical signal into a quantifiable electrical signal. Toxicity assessment of heavy metals using E.coli biosensors could be finished within 30 min and the 50% effective concentrations (ECso) values of four heavy metals were determined. The results shows that inhibitory effects of four heavy metals to E.coli can be ranked in a decreasing order of Hg^2+ 〉 Cu^2+ 〉 Zn^2+ 〉 Ni^2+, which accords to the results of conventional bacterial counting method. The toxicity test of organic compounds by using CellSense biosensor was also demonstrated. The CellSense biosensor with E. coli shows a good, reproducible behavior and can be used for reproducible measurements.
基金supported by the National Natural Science Foundation of China (No. 20707035,20777089)the National High Technology Research and Development Program (863) of China (No. 2007AA06A407)
文摘The prediction and assessment of environmental pollution by arsenic are important preconditions of advocating environmental protection and human health risk assessment. A yellow fluorescent protein-based whole-cell biosensor for the detection of arsenite and arsenate was constructed and tested. An arsenic-resistant promoter and the regulatory gene arsR were obtained by PCR from the genome ofEscherichia coli DH5ct, andphiYFP was introduced into E. coli DH5ct as a reporter gene to construct an arsenic-resistant whole-cell biosensor (WCB-11) in which phiYFP was expressed well for the first time. Experimental results demonstrated that the biosensor has a good response to arsenic and the expression ofphiYFP. When strain WCB-11 was exposed to As^3+ and As^5+, the expression of yellow fluorescence was time-dependent and dose-dependent. This engineered construct is expected to become established as an inexpensive and convenient method for the detection of arsenic in the field.
基金supported by the National Natural Science Foundation of China (No. 2117145)
文摘Detection of N-acyl homoserine lactones (AHLs) is useful for understanding quorum sensing (QS) behaviors, including biofilm formation, virulence and metabolism. For detecting AHLs and indicating the host cells in situ, we constructed the plasmid pUCGMA2T1-4 to make a dual fluorescent whole- cell biosensor based on the AhlI/R AHL system of Pseudomonas syringae pv. syringae B728a. The plasmid contains three components: constitutively expressed enptll::gfP for indicating host cells, Pahll::mcherry that produces red fluorescence in response to AHL, and the ahIR gene that encodes an AHL regulatory protein. Meanwhile, two copies of T1-4 (four tandem copies of a transcriptional terminator) were added into the plasmid to reduce background. The results showed that when the plasmid was placed into Escherichia coli, the dual fluorescence whole-cell biosensor was able to respond with red fluorescence within 6 hr to 5 × 10^-8-1 × 10^-5 mol/L of 3OC6-HSL. Bright green fluorescence indicated the host cells. Furthermore, when the plasmid was transferred to wild- type Pseudomonas PhTA125 (an AHL-producing bacterium), it also showed both green and red fluorescence. This result demonstrates that this plasmid can be used to construct whole-cell indicators that can indicate the AHL response and spatial behaviors of microbes in a mi tal niche
基金This work was supported by the National Natural Science Foundation of China (Grant Nos. 30270387, No. 30570492);the Project of State Key Laboratory of Transducer Technology of China (Grant No. SKT0403);the Foundation for the Bureau of Zhejiang Province of China (Grant No. 20040197).
文摘The light-addressable potentiometric sensor (LAPS) is a semiconductor-based cellular biosensor with an electrolyte-insulator-semiconductor (EIS) structure.By depositing biocompatible layers on the sensing surface for cell culture, it can be used to detect bioelectrical parameters of cells.The characteristic curve for photocurrent versus applied bias voltage to the system shows a current-voltage curve (Ⅰ-Ⅴcurve).This technique can be used to detect the action potential changes towards different drugs based on the bias voltage dependence of an optical current,and provides a dynamic system by scanning light beam at the very cell on the sensor device.The LAPS overcomes the limitation of recording sites,but high spatial resolution and sensitivity are also paramount.This paper discussed a novel structure of LAPS array for extracellular monitoring to decrease potential noise level.Both characteristics of active recording array areas and cell culture conditions are measured.
基金Acknowledgement: This work was supported by the National Natural Science Foundation of China (Grant Nos. 30270387, No. 30570492);the Project of State Key Laboratory of Transducer Technology of China (Grant No. SKT0403);the Foundation for the Bureau of Zhejiang Province of China (Grant No. 20040197).
文摘This paper reviews a novel cell-based biosensor and Bio-MEMS which incorporate living cells as sensing elements that convert a change in immediate environment to signals conducive for processing.It is characterized with high sensitivity,excellent selectivity and fast response and have been implemented for a number of applications ranging from pharmaceutical screening to environmental pollutant detection.This paper also introduces our recent work about Light-Addressable Potentiometric Sensors (LAPS),Field Effect Transistor (FET),Micro-Electrode Array Sensors (MEAS) and Bio-MEMS for detecting the changes of concentration of extracellular ions and the action potential of living cell under effect of drugs and environmental parameters.Finely, the paper gives some prospects of cell-based biosensors in the future.
文摘In this study, an enzymatic electrode for glucose biosensing and bioanode of glucose/air biofuel cell has been fabricated by immobilizing poly (methylene green) (polyMG) for electrocatalytic NADH oxidation and NAD+-dependent glucose dehydrogenase (GDH) for oxidizing glucose on carbon nanodots (CNDs). The polyMG-CNDscomposites obtained by electro-polymerization of dye MG molecules adsorbed on CNDs display excellent electrocatalytic activity toward NADH electro-oxidation at a low overpotential of ca. -0.10 V (vs. Ag/AgCl) and the integrated enzymatic electrode shows fast response to glucose electrooxidation. Using the fabricated GDH-based enzymatic electrode, a glucose biosensor was constructed and exhibits a wide linear dynamic range from 0 to 8 mM, a low detection limit of 0.02 μM (S/N = 3), and fast response time (ca. 4 s) under the optimized conditions. The developed glucose biosensor was used to detect glucose content in human blood with satisfactory results. The fabricated GDH-based enzymatic electrode was also employed as bioanode to assembly a glucose/air biofuel cell with the laccase-CNDs/GC as the biocathode. The maximum power density delivered by the assembled glucose/air biofuel cell reaches 3.1 μW·cm-2 at a cell voltage of 0.22 V in real sample fruit juice. The present study demonstrates that potential applications of GDH-based CNDs electrode in analytical and biomedical measurements.