A technique was developed to study mass trans fer process and inter facial reaction in two phases system. This constant inter facial cell with a laminar flow was made into a cubic structure. The two fluids were contin...A technique was developed to study mass trans fer process and inter facial reaction in two phases system. This constant inter facial cell with a laminar flow was made into a cubic structure. The two fluids were continuously recycled and mixed. The concentration of each liquid could be monitored by two different methods. This kind of structure made both flows near the inter face flow parallel to the inter face. The inter face was smooth and steady. The mass trans fer rate could be judged by the linear velocity of the flows. The technique can be used for the analyses of the control step in both phases near the inter face in a diffusion control process. A preliminary hydrodynamics and mass trans fer study on the cell was presented, which ensures the distinguishing between a diffusion and a chemical reaction control process. A simplified mass transfer equation,N =0.5303D 1 /2* (Ci- Cb)* (V / B) 1/2, was achieved.展开更多
A novel constant interfacial area cell(NCIAC),by spatially separating the agitation from liquid flow circulation of organic and aqueous two phases,was suggested to obtain detailed kinetic data for Er(Ⅲ) extraction fr...A novel constant interfacial area cell(NCIAC),by spatially separating the agitation from liquid flow circulation of organic and aqueous two phases,was suggested to obtain detailed kinetic data for Er(Ⅲ) extraction from chloride medium by 2-ethyl-hexyl-phosphonic acid mono-(2-ethylhexyl) ester(EHEHPA).Different from the traditional Lewis cell and the constant interfacial area cell with laminar flow,the concentrations of Er(Ⅲ) in organic and aqueous two phases were uniform,and the stability of the interfacial area between the two phases could be controlled effectively.Therefore,the special requirements for the design of agitators in the traditional Lewis cell and the constant interfacial area cell for minimizing the influence of diffusion resistance could be avoided.Experimental results indicated that the extraction kinetics was mainly affected by the aqueous flow rate,interfacial area between organic and aqueous two phases,and the aqueous p H values.An extraction kinetic equation was suggested based on the experimental data.展开更多
The extraction kinetics of La(III) from aqueous chloride solutions into n-heptane solutions of bifunctional ionic liquid extractant [A336][CA-12](tricaprylmethylammonium sec-octylphenoxy acetic acid) was investigated ...The extraction kinetics of La(III) from aqueous chloride solutions into n-heptane solutions of bifunctional ionic liquid extractant [A336][CA-12](tricaprylmethylammonium sec-octylphenoxy acetic acid) was investigated using a constant interfacial cell with laminar flow. The effects of stirring speed, temperature and specific interfacial area on the extraction rate were examined. The results indicate that mass transfer kinetics of La(III) is a mixed-controlled process influenced by interfacial reaction. On the basis of mass transfer kinetic results in the extraction of La(III) by [A336][CA-12], the extraction rate equation of La(III) is proposed in terms of pseudo-firstorder constants, which is supported by the measured thermodynamic equations. The mass-transfer kinetic model deduced from the rate controlling step is adequate to interpret the experimental data qualitatively.展开更多
Chemical bath deposition technique has been used to deposit Ni-doped Sb2S3 thin films onto glass substrate. Doping was carried out by adding 1, 3 and 5 wt% of Ni. Bath temperature was kept as 10℃ and films were annea...Chemical bath deposition technique has been used to deposit Ni-doped Sb2S3 thin films onto glass substrate. Doping was carried out by adding 1, 3 and 5 wt% of Ni. Bath temperature was kept as 10℃ and films were annealed at 250℃ under vacuum. Polycrystalline nature of films with an orthorhombic phase was analyzed by X-ray diffraction technique. Scanning electron microscopy was used for morphological study which shows that grains are spherical. Optical measurements using transmittance data indicated that films have a direct band gap of 1.00 - 2.60 eV with an absorption coefficient of ~104 cm<sup>-1</sup> in visible range. The average value of electrical conductivity was calculated as 1.66, 1.11 and 1.06 (Ω·cm)<sup>-1</sup> for as-deposited films and 1.90, 2.08 and 1.15 (Ω·cm)<sup>-1</sup> for annealed films while refractive indices were found as 2.18 - 3.38 and 1.91 - 3.74 respectively. The obtained films can be used for solar cell applications due to their good absorbing properties like higher absorption coefficient and refractive index values.展开更多
This paper presents a Lagrangian cell-centered conservative gas dynamics scheme. The piecewise constant pressures of cells arising from the current time sub-cell densities and the current time isentropic speed of soun...This paper presents a Lagrangian cell-centered conservative gas dynamics scheme. The piecewise constant pressures of cells arising from the current time sub-cell densities and the current time isentropic speed of sound are introduced. Multipling the initial cell density by the initial sub-cell volumes obtains the sub-cell Lagrangian masses, and dividing the masses by the current time sub-cell volumes gets the current time sub- cell densities. By the current time piecewise constant pressures of cells, a scheme that conserves the momentum and total energy is constructed. The vertex velocities and the numerical fluxes through the cell interfaces are computed in a consistent manner due to an original solver located at the nodes. The numerical tests are presented, which are representative for compressible flows and demonstrate the robustness and accuracy of the Lagrangian cell-centered conservative scheme.展开更多
he cell averaging and the order statistics are two typical algorithms for constant false alarm rate detector in radar system. They have different advantages in stationary noise background and fluctuation clutter envir...he cell averaging and the order statistics are two typical algorithms for constant false alarm rate detector in radar system. They have different advantages in stationary noise background and fluctuation clutter environment respectively. This paper presents a doublethreshold constant false alarm rate detector constructed on the basis of synthesizing the advantages of the two algorithms above and avioding their disadvantages. The performance of the detector is analyzed, and the simulation result is given.展开更多
Objective: To evaluate the feasibility of dynamic contrast-enhanced magnetic resonance imaging(DCEMRI) for predicting tumor response to radiotherapy in patients with suspected primary central nervous system(CNS) ...Objective: To evaluate the feasibility of dynamic contrast-enhanced magnetic resonance imaging(DCEMRI) for predicting tumor response to radiotherapy in patients with suspected primary central nervous system(CNS) germ cell tumors(GCTs).Methods: DCE-MRI parameters of 35 patients with suspected primary CNS GCTs were obtained prior to diagnostic radiation, using the Tofts and Kermode model. Radiosensitivity was determined in tumors diagnosed 2 weeks after radiation by observing changes in tumor size and markers as a response to MRI. Taking radiosensitivity as the gold standard, the cut-off value of DCE-MRI parameters was measured by receiver operating characteristic(ROC) curve. Diagnostic accuracy of DCE-MRI parameters for predicting radiosensitivity was evaluated by ROC curve.Results: A significant elevation in transfer constant(K^trans) and extravascular extracellular space(Ve)(P=0.000), as well as a significant reduction in rate constant(Kep)(P=0.000) was observed in tumors. K^trans, relative K^trans, and relative Kep of the responsive group were significantly higher than non-responsive groups. No significant difference was found in Kep, Ve, and relative Ve between the two groups. Relative K^trans showed the best diagnostic value in predicting radiosensitivity with a sensitivity of 100%, specificity of 91.7%, positive predictive value(PPV) of 95.8%, and negative predictive value(NPV) of 100%.Conclusions: Relative K^trans appeared promising in predicting tumor response to radiation therapy(RT). It is implied that DCE-MRI pre-treatment is a requisite step in diagnostic procedures and a novel and reliable approach to guide clinical choice of RT.展开更多
文摘A technique was developed to study mass trans fer process and inter facial reaction in two phases system. This constant inter facial cell with a laminar flow was made into a cubic structure. The two fluids were continuously recycled and mixed. The concentration of each liquid could be monitored by two different methods. This kind of structure made both flows near the inter face flow parallel to the inter face. The inter face was smooth and steady. The mass trans fer rate could be judged by the linear velocity of the flows. The technique can be used for the analyses of the control step in both phases near the inter face in a diffusion control process. A preliminary hydrodynamics and mass trans fer study on the cell was presented, which ensures the distinguishing between a diffusion and a chemical reaction control process. A simplified mass transfer equation,N =0.5303D 1 /2* (Ci- Cb)* (V / B) 1/2, was achieved.
基金Supported by the National Natural Science Foundation of China(51574213,51074150)the Key Project of Chinese National Programs for Fundamental Research and Development(2012CBA01203,2013CB632602)
文摘A novel constant interfacial area cell(NCIAC),by spatially separating the agitation from liquid flow circulation of organic and aqueous two phases,was suggested to obtain detailed kinetic data for Er(Ⅲ) extraction from chloride medium by 2-ethyl-hexyl-phosphonic acid mono-(2-ethylhexyl) ester(EHEHPA).Different from the traditional Lewis cell and the constant interfacial area cell with laminar flow,the concentrations of Er(Ⅲ) in organic and aqueous two phases were uniform,and the stability of the interfacial area between the two phases could be controlled effectively.Therefore,the special requirements for the design of agitators in the traditional Lewis cell and the constant interfacial area cell for minimizing the influence of diffusion resistance could be avoided.Experimental results indicated that the extraction kinetics was mainly affected by the aqueous flow rate,interfacial area between organic and aqueous two phases,and the aqueous p H values.An extraction kinetic equation was suggested based on the experimental data.
基金Supported by the National Natural Science Foundation of China(51174184)National Basic Research Program of China(2012CBA01202)+3 种基金the Key Research Programof the Chinese Academy of Sciences(KGZD-EW-201-1)the Science and Technology Planof Nantong City(BK2013030)the University Science Research Project of Jiangsu Province(14KJB150019)Open Subject of Changchun Institute of Applied Chemistry,Chinese Academy of Sciences(RERU2014016)
文摘The extraction kinetics of La(III) from aqueous chloride solutions into n-heptane solutions of bifunctional ionic liquid extractant [A336][CA-12](tricaprylmethylammonium sec-octylphenoxy acetic acid) was investigated using a constant interfacial cell with laminar flow. The effects of stirring speed, temperature and specific interfacial area on the extraction rate were examined. The results indicate that mass transfer kinetics of La(III) is a mixed-controlled process influenced by interfacial reaction. On the basis of mass transfer kinetic results in the extraction of La(III) by [A336][CA-12], the extraction rate equation of La(III) is proposed in terms of pseudo-firstorder constants, which is supported by the measured thermodynamic equations. The mass-transfer kinetic model deduced from the rate controlling step is adequate to interpret the experimental data qualitatively.
文摘Chemical bath deposition technique has been used to deposit Ni-doped Sb2S3 thin films onto glass substrate. Doping was carried out by adding 1, 3 and 5 wt% of Ni. Bath temperature was kept as 10℃ and films were annealed at 250℃ under vacuum. Polycrystalline nature of films with an orthorhombic phase was analyzed by X-ray diffraction technique. Scanning electron microscopy was used for morphological study which shows that grains are spherical. Optical measurements using transmittance data indicated that films have a direct band gap of 1.00 - 2.60 eV with an absorption coefficient of ~104 cm<sup>-1</sup> in visible range. The average value of electrical conductivity was calculated as 1.66, 1.11 and 1.06 (Ω·cm)<sup>-1</sup> for as-deposited films and 1.90, 2.08 and 1.15 (Ω·cm)<sup>-1</sup> for annealed films while refractive indices were found as 2.18 - 3.38 and 1.91 - 3.74 respectively. The obtained films can be used for solar cell applications due to their good absorbing properties like higher absorption coefficient and refractive index values.
基金supported by the National Natural Science Foundation of China (No. 11172050)
文摘This paper presents a Lagrangian cell-centered conservative gas dynamics scheme. The piecewise constant pressures of cells arising from the current time sub-cell densities and the current time isentropic speed of sound are introduced. Multipling the initial cell density by the initial sub-cell volumes obtains the sub-cell Lagrangian masses, and dividing the masses by the current time sub-cell volumes gets the current time sub- cell densities. By the current time piecewise constant pressures of cells, a scheme that conserves the momentum and total energy is constructed. The vertex velocities and the numerical fluxes through the cell interfaces are computed in a consistent manner due to an original solver located at the nodes. The numerical tests are presented, which are representative for compressible flows and demonstrate the robustness and accuracy of the Lagrangian cell-centered conservative scheme.
文摘he cell averaging and the order statistics are two typical algorithms for constant false alarm rate detector in radar system. They have different advantages in stationary noise background and fluctuation clutter environment respectively. This paper presents a doublethreshold constant false alarm rate detector constructed on the basis of synthesizing the advantages of the two algorithms above and avioding their disadvantages. The performance of the detector is analyzed, and the simulation result is given.
基金supported by Beijing Natural Science Foundation(No.7122029)
文摘Objective: To evaluate the feasibility of dynamic contrast-enhanced magnetic resonance imaging(DCEMRI) for predicting tumor response to radiotherapy in patients with suspected primary central nervous system(CNS) germ cell tumors(GCTs).Methods: DCE-MRI parameters of 35 patients with suspected primary CNS GCTs were obtained prior to diagnostic radiation, using the Tofts and Kermode model. Radiosensitivity was determined in tumors diagnosed 2 weeks after radiation by observing changes in tumor size and markers as a response to MRI. Taking radiosensitivity as the gold standard, the cut-off value of DCE-MRI parameters was measured by receiver operating characteristic(ROC) curve. Diagnostic accuracy of DCE-MRI parameters for predicting radiosensitivity was evaluated by ROC curve.Results: A significant elevation in transfer constant(K^trans) and extravascular extracellular space(Ve)(P=0.000), as well as a significant reduction in rate constant(Kep)(P=0.000) was observed in tumors. K^trans, relative K^trans, and relative Kep of the responsive group were significantly higher than non-responsive groups. No significant difference was found in Kep, Ve, and relative Ve between the two groups. Relative K^trans showed the best diagnostic value in predicting radiosensitivity with a sensitivity of 100%, specificity of 91.7%, positive predictive value(PPV) of 95.8%, and negative predictive value(NPV) of 100%.Conclusions: Relative K^trans appeared promising in predicting tumor response to radiation therapy(RT). It is implied that DCE-MRI pre-treatment is a requisite step in diagnostic procedures and a novel and reliable approach to guide clinical choice of RT.