A heat center (HC) of the western Pacific warm pool (WPWP) is defined, its variability is examined, and a possible mechanism is discussed. Analysis and calculation of a temperature dataset from 1945-2006 show that... A heat center (HC) of the western Pacific warm pool (WPWP) is defined, its variability is examined, and a possible mechanism is discussed. Analysis and calculation of a temperature dataset from 1945-2006 show that the mean position of the HC during this period was near 0.4°S/169.0°E, at 38.0 m depth. From a time series of the HC, remarkable seasonal variability was found, mainly in the meridional and vertical directions. Interannual variabilities were dominant in the zonal and vertical directions. In addition, semiannual variation in the HC depth was discovered. The longitude of the HC varies with ENSO events, and its latitude is weakly related to ENSO on time scales shorter than a decade. The variation of the HC longitude leads the Nifio-3 index by about 3-4 months, and its depth lags the index for approximately 3 months. It is concluded that the HC depth results from a combination of its longitudinal and latitudinal variations. Low-pass-filtered time series reveal that the HC has moved eastward since the mid 1980s. 展开更多
关键词 western Pacific warm pool heat center VARIABILITY
下载PDF
Experimental Study on Rack Cooling System based on a Pulsating Heat Pipe 被引量:3
2
作者 LU Qianyi JIA Li 《Journal of Thermal Science》 SCIE EI CAS CSCD 2016年第1期60-67,共8页
A rack cooling system based on a large scale flat plate pulsating heat pipe is proposed. The heat generated from IT equipment in a closed rack is transferred by the rear door pulsating heat pipe to the chilled air pas... A rack cooling system based on a large scale flat plate pulsating heat pipe is proposed. The heat generated from IT equipment in a closed rack is transferred by the rear door pulsating heat pipe to the chilled air passage and is avoided to release into the room. The influence of the start-up performance of the heat pipe, the load of the rack and the load dissipation to the temperature and the velocity distribution in the rack are discussed. It is found that the temperature would be lower and the temperature distribution would be more uniform in the rack when the pulsating heat pipe is in operation. Also, the effect of rack electricity load on temperature distribution is analyzed. It is indicated that higher velocity of chilled air will improve heat transfer of the rack. 展开更多
关键词 cooling rack data center pulsating heat pipe
原文传递